-
Beneath the Surface: Revealing Deep-Tissue Blood Flow in Human Subjects with Massively Parallelized Diffuse Correlation Spectroscopy
Authors:
Lucas Kreiss,
Melissa Wu,
Michael Wayne,
Shiqi Xu,
Paul McKee,
Derrick Dwamena,
Kanghyun Kim,
Kyung Chul Lee,
Wenhui Liu,
Aarin Ulku,
Mark Harfouche,
Xi Yang,
Clare Cook,
Amey Chaware,
Seung Ah Lee,
Erin Buckley,
Claudio Bruschini,
Edoardo Charbon,
Scott Huettel,
Roarke Horstmeyer
Abstract:
Diffuse Correlation Spectroscopy (DCS) allows the label-free investigation of microvascular dynamics deep within living tissue. However, common implementations of DCS are currently limited to measurement depths of $\sim 1-1.5cm$, which can limit the accuracy of cerebral hemodynamics measurement. Here we present massively parallelized DCS (pDCS) using novel single photon avalanche detector (SPAD) a…
▽ More
Diffuse Correlation Spectroscopy (DCS) allows the label-free investigation of microvascular dynamics deep within living tissue. However, common implementations of DCS are currently limited to measurement depths of $\sim 1-1.5cm$, which can limit the accuracy of cerebral hemodynamics measurement. Here we present massively parallelized DCS (pDCS) using novel single photon avalanche detector (SPAD) arrays with up to 500x500 individual channels. The new SPAD array technology can boost the signal-to-noise ratio by a factor of up to 500 compared to single-pixel DCS, or by more than 15-fold compared to the most recent state-of-the-art pDCS demonstrations. Our results demonstrate the first in vivo use of this massively parallelized DCS system to measure cerebral blood flow changes at $\sim 2cm$ depth in human adults. We compared different modes of operation and applied a dual detection strategy, where a secondary SPAD array is used to simultaneously assess the superficial blood flow as a built-in reference measurement. While the blood flow in the superficial scalp tissue showed no significant change during cognitive activation, the deep pDCS measurement showed a statistically significant increase in the derived blood flow index of 8-12% when compared to the control rest state.
△ Less
Submitted 25 June, 2024; v1 submitted 6 March, 2024;
originally announced March 2024.
-
Time-resolved laser speckle contrast imaging (TR-LSCI) of cerebral blood flow
Authors:
Faraneh Fathi,
Siavash Mazdeyasna,
Dara Singh,
Chong Huang,
Mehrana Mohtasebi,
Xuhui Liu,
Samaneh Rabienia Haratbar,
Mingjun Zhao,
Li Chen,
Arin Can Ulku,
Paul Mos,
Claudio Bruschini,
Edoardo Charbon,
Lei Chen,
Guoqiang Yu
Abstract:
To address many of the deficiencies in optical neuroimaging technologies such as poor spatial resolution, time-consuming reconstruction, low penetration depth, and contact-based measurement, a novel, noncontact, time-resolved laser speckle contrast imaging (TR-LSCI) technique has been developed for continuous, fast, and high-resolution 2D map** of cerebral blood flow (CBF) at different depths of…
▽ More
To address many of the deficiencies in optical neuroimaging technologies such as poor spatial resolution, time-consuming reconstruction, low penetration depth, and contact-based measurement, a novel, noncontact, time-resolved laser speckle contrast imaging (TR-LSCI) technique has been developed for continuous, fast, and high-resolution 2D map** of cerebral blood flow (CBF) at different depths of the head. TR-LSCI illuminates the head with picosecond-pulsed, coherent, widefield near-infrared light and synchronizes a newly developed, high-resolution, gated single-photon avalanche diode camera (SwissSPAD2) to capture CBF maps at different depths. By selectively collecting diffuse photons with longer pathlengths through the head, TR-LSCI reduces partial volume artifacts from the overlying tissues, thus improving the accuracy of CBF measurement in the deep brain. CBF map reconstruction was dramatically expedited by incorporating highly parallelized computation. The performance of TR-LSCI was evaluated using head-simulating phantoms with known properties and in-vivo rodents with varied hemodynamic challenges to the brain. Results from these pilot studies demonstrated that TR-LSCI enabled map** CBF variations at different depths with a sampling rate of up to 1 Hz and spatial resolutions ranging from tens of micrometers on the head surface to 1-2 millimeters in the deep brain. With additional improvements and validation in larger populations against established methods, we anticipate offering a noncontact, fast, high-resolution, portable, and affordable brain imager for fundamental neuroscience research in animals and for translational studies in humans.
△ Less
Submitted 23 September, 2023;
originally announced September 2023.
-
Correlated-photon imaging at 10 volumetric images per second
Authors:
Gianlorenzo Massaro,
Paul Mos,
Sergii Vasiukov,
Francesco Di Lena,
Francesco Scattarella,
Francesco V. Pepe,
Arin Ulku,
Davide Giannella,
Edoardo Charbon,
Claudio Bruschini,
Milena D'Angelo
Abstract:
The correlation properties of light provide an outstanding tool to overcome the limitations of traditional imaging techniques. A relevant case is represented by correlation plenoptic imaging (CPI), a quantum-inspired volumetric imaging protocol employing spatio-temporally correlated photons from either entangled or chaotic sources to address the main limitations of conventional light-field imaging…
▽ More
The correlation properties of light provide an outstanding tool to overcome the limitations of traditional imaging techniques. A relevant case is represented by correlation plenoptic imaging (CPI), a quantum-inspired volumetric imaging protocol employing spatio-temporally correlated photons from either entangled or chaotic sources to address the main limitations of conventional light-field imaging, namely, the poor spatial resolution and the reduced change of perspective for 3D imaging. However, the application potential of high-resolution imaging modalities relying on photon correlations is limited, in practice, by the need to collect a large number of frames. This creates a gap, unacceptable for many relevant tasks, between the time performance of correlated-light imaging and that of traditional imaging methods. In this article, we address this issue by exploiting the photon number correlations intrinsic in chaotic light, combined with a cutting-edge ultrafast sensor made of a large array of single-photon avalanche diodes (SPADs). This combination of source and sensor is embedded within a novel single-lens CPI scheme enabling to acquire 10 volumetric images per second. Our results place correlated-photon imaging at a competitive edge and prove its potential in practical applications.
△ Less
Submitted 7 August, 2023; v1 submitted 5 December, 2022;
originally announced December 2022.
-
Resolving the controversy in biexciton binding energy of cesium lead halide perovskite nanocrystals through heralded single-particle spectroscopy
Authors:
Gur Lubin,
Gili Yaniv,
Miri Kazes,
Arin Can Ulku,
Ivan Michel Antolovic,
Samuel Burri,
Claudio Bruschini,
Edoardo Charbon,
Venkata Jayasurya Yallapragada,
Dan Oron
Abstract:
Understanding exciton-exciton interaction in multiply-excited nanocrystals is crucial to their utilization as functional materials. Yet, for lead halide perovskite nanocrystals, which are promising candidates for nanocrystal-based technologies, numerous contradicting values have been reported for the strength and sign of their exciton-exciton interaction. In this work we unambiguously determine th…
▽ More
Understanding exciton-exciton interaction in multiply-excited nanocrystals is crucial to their utilization as functional materials. Yet, for lead halide perovskite nanocrystals, which are promising candidates for nanocrystal-based technologies, numerous contradicting values have been reported for the strength and sign of their exciton-exciton interaction. In this work we unambiguously determine the biexciton binding energy in single cesium lead halide perovskite nanocrystals at room temperature. This is enabled by the recently introduced SPAD array spectrometer, capable of temporally isolating biexciton-exciton emission cascades while retaining spectral resolution. We demonstrate that CsPbBr$_3$ nanocrystals feature an attractive exciton-exciton interaction, with a mean biexciton binding energy of 10 meV. For CsPbI$_3$ nanocrystals we observe a mean biexciton binding energy that is close to zero, and individual nanocrystals show either weakly attractive or weakly repulsive exciton-exciton interaction. We further show that within ensembles of both materials, single-nanocrystal biexciton binding energies are correlated with the degree of charge-carrier confinement.
△ Less
Submitted 31 July, 2021;
originally announced August 2021.
-
Heralded spectroscopy reveals exciton-exciton correlations in single colloidal quantum dots
Authors:
Gur Lubin,
Ron Tenne,
Arin Can Ulku,
Ivan Michel Antolovic,
Samuel Burri,
Sean Karg,
Venkata Jayasurya Yallapragada,
Claudio Bruschini,
Edoardo Charbon,
Dan Oron
Abstract:
Multiply-excited states in semiconductor quantum dots feature intriguing physics and play a crucial role in nanocrystal-based technologies. While photoluminescence provides a natural probe to investigate these states, room temperature single-particle spectroscopy of their emission has so far proved elusive due to the temporal and spectral overlap with emission from the singly-excited and charged s…
▽ More
Multiply-excited states in semiconductor quantum dots feature intriguing physics and play a crucial role in nanocrystal-based technologies. While photoluminescence provides a natural probe to investigate these states, room temperature single-particle spectroscopy of their emission has so far proved elusive due to the temporal and spectral overlap with emission from the singly-excited and charged states. Here we introduce biexciton heralded spectroscopy, enabled by a single-photon avalanche diode array based spectrometer. This allows us to directly observe biexciton-exciton emission cascades and measure the biexciton binding energy of single quantum dots at room temperature, even though it is well below the scale of thermal broadening and spectral diffusion. Furthermore, we uncover correlations hitherto masked in ensembles, of the biexciton binding energy with both charge-carrier confinement and fluctuations of the local electrostatic potential. Heralded spectroscopy has the potential of greatly extending our understanding of charge-carrier dynamics in multielectron systems and of parallelization of quantum optics protocols.
△ Less
Submitted 31 July, 2021;
originally announced August 2021.
-
Towards quantum 3D imaging devices: the Qu3D project
Authors:
Cristoforo Abbattista,
Leonardo Amoruso,
Samuel Burri,
Edoardo Charbon,
Francesco Di Lena,
Augusto Garuccio,
Davide Giannella,
Zdenek Hradil,
Michele Iacobellis,
Gianlorenzo Massaro,
Paul Mos,
Libor Motka,
Martin Paur,
Francesco V. Pepe,
Michal Peterek,
Isabella Petrelli,
Jaroslav Rehacek,
Francesca Santoro,
Francesco Scattarella,
Arin Ulku,
Sergii Vasiukov,
Michael Wayne,
Milena D'Angelo,
Claudio Bruschini,
Maria Ieronymaki
, et al. (1 additional authors not shown)
Abstract:
We review the advancement of the research toward the design and implementation of quantum plenoptic cameras, radically novel 3D imaging devices that exploit both momentum-position entanglement and photon-number correlations to provide the typical refocusing and ultra-fast, scanning-free, 3D imaging capability of plenoptic devices, along with dramatically enhanced performances, unattainable in stan…
▽ More
We review the advancement of the research toward the design and implementation of quantum plenoptic cameras, radically novel 3D imaging devices that exploit both momentum-position entanglement and photon-number correlations to provide the typical refocusing and ultra-fast, scanning-free, 3D imaging capability of plenoptic devices, along with dramatically enhanced performances, unattainable in standard plenoptic cameras: diffraction-limited resolution, large depth of focus, and ultra-low noise. To further increase the volumetric resolution beyond the Rayleigh diffraction limit, and achieve the quantum limit, we are also develo** dedicated protocols based on quantum Fisher information. However, for the quantum advantages of the proposed devices to be effective and appealing to end-users, two main challenges need to be tackled. First, due to the large number of frames required for correlation measurements to provide an acceptable SNR, quantum plenoptic imaging would require, if implemented with commercially available high-resolution cameras, acquisition times ranging from tens of seconds to a few minutes. Second, the elaboration of this large amount of data, in order to retrieve 3D images or refocusing 2D images, requires high-performance and time-consuming computation. To address these challenges, we are develo** high-resolution SPAD arrays and high-performance low-level programming of ultra-fast electronics, combined with compressive sensing and quantum tomography algorithms, with the aim to reduce both the acquisition and the elaboration time by two orders of magnitude. Routes toward exploitation of the QPI devices will also be discussed.
△ Less
Submitted 14 June, 2021;
originally announced June 2021.
-
A megapixel time-gated SPAD image sensor for 2D and 3D imaging applications
Authors:
Kazuhiro Morimoto,
Andrei Ardelean,
Ming-Lo Wu,
Arin Can Ulku,
Ivan Michel Antolovic,
Claudio Bruschini,
Edoardo Charbon
Abstract:
We present the first 1Mpixel SPAD camera ever reported. The camera features 3.8ns time gating and 24kfps frame rate; it was fabricated in 180nm CIS technology. Two pixels have been designed with a pitch of 9.4$μ$m in 7T and 5.75T configurations, respectively, achieving a maximum fill factor of 13.4%. The maximum PDP is 27%, median DCR 2.0cps, variation in gating length 120ps, position skew 410ps,…
▽ More
We present the first 1Mpixel SPAD camera ever reported. The camera features 3.8ns time gating and 24kfps frame rate; it was fabricated in 180nm CIS technology. Two pixels have been designed with a pitch of 9.4$μ$m in 7T and 5.75T configurations, respectively, achieving a maximum fill factor of 13.4%. The maximum PDP is 27%, median DCR 2.0cps, variation in gating length 120ps, position skew 410ps, and rise/fall time <550ps, all FWHM at 3.3V of excess bias. The sensor was used to capture 2D/3D scenes over 2m with an LSB of 5.4mm and a precision better than 7.8mm. Extended dynamic range is demonstrated in dual exposure operation mode. Spatially overlapped multi-object detection is experimentally demonstrated in single-photon time-gated ToF for the first time.
△ Less
Submitted 30 December, 2019;
originally announced December 2019.