-
Test of UFSD Silicon Detectors for the TOTEM Upgrade Project
Authors:
R. Arcidiacono,
M. Berretti,
E. Bossini,
M. Bozzo,
N. Cartiglia,
M. Ferrero,
V. Georgiev,
T. Isidori,
R. Linhart,
N. Minafra,
M. M. Obertino,
V. Sola,
N. Turini
Abstract:
This paper describes the performance of a prototype timing detector, based on 50 micrometer thick Ultra Fast Silicon Detector, as measured in a beam test using a 180 GeV/c momentum pion beam. The dependence of the time precision on the pixel capacitance and the bias voltage is investigated here. A timing precision from 30 ps to 100 ps, depending on the pixel capacitance, has been measured at a bia…
▽ More
This paper describes the performance of a prototype timing detector, based on 50 micrometer thick Ultra Fast Silicon Detector, as measured in a beam test using a 180 GeV/c momentum pion beam. The dependence of the time precision on the pixel capacitance and the bias voltage is investigated here. A timing precision from 30 ps to 100 ps, depending on the pixel capacitance, has been measured at a bias voltage of 180 V. Timing precision has also been measured as a function of the bias voltage.
△ Less
Submitted 16 February, 2017;
originally announced February 2017.
-
Diamond Detectors for the TOTEM Timing Upgrade
Authors:
TOTEM Collaboration,
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
V. Berardi,
M. Berretti,
E. Bossini,
U. Bottigli,
M. Bozzo,
P. Broulím,
A. Buzzo,
F. S. Cafagna,
M. G. Catanesi,
M. Csanád,
T. Csörgő,
M. Deile,
F. De Leonardis,
A. D'Orazio,
M. Doubek,
K. Eggert,
V. Eremin,
F. Ferro,
A. Fiergolski
, et al. (58 additional authors not shown)
Abstract:
This paper describes the design and the performance of the timing detector developed by the TOTEM Collaboration for the Roman Pots (RPs) to measure the Time-Of-Flight (TOF) of the protons produced in central diffractive interactions at the LHC. The measurement of the TOF of the protons allows the determination of the longitudinal position of the proton interaction vertex and its association with o…
▽ More
This paper describes the design and the performance of the timing detector developed by the TOTEM Collaboration for the Roman Pots (RPs) to measure the Time-Of-Flight (TOF) of the protons produced in central diffractive interactions at the LHC. The measurement of the TOF of the protons allows the determination of the longitudinal position of the proton interaction vertex and its association with one of the vertices reconstructed by the CMS detectors. The TOF detector is based on single crystal Chemical Vapor Deposition (scCVD) diamond plates and is designed to measure the protons TOF with about 50 ps time precision. This upgrade to the TOTEM apparatus will be used in the LHC run 2 and will tag the central diffractive events up to an interaction pileup of about 1. A dedicated fast and low noise electronics for the signal amplification has been developed. The digitization of the diamond signal is performed by sampling the waveform. After introducing the physics studies that will most profit from the addition of these new detectors, we discuss in detail the optimization and the performance of the first TOF detector installed in the LHC in November 2015.
△ Less
Submitted 18 January, 2017;
originally announced January 2017.
-
Timing Performance of a Double Layer Diamond Detector
Authors:
M. Berretti,
E. Bossini,
M. Bozzo,
V. Georgiev,
T. Isidori,
R. Linhart,
N. Turini
Abstract:
In order to improve the time precision of detectors based on diamonds sensors we have built a detector with two scCVD layers connected in parallel to the same amplifier. This note describes the design and the first measurements of such a prototype performed on a particle beam at CERN. With this different configuration we have obtained an improvement on the timing precision of a factor of 1.6-1.7 w…
▽ More
In order to improve the time precision of detectors based on diamonds sensors we have built a detector with two scCVD layers connected in parallel to the same amplifier. This note describes the design and the first measurements of such a prototype performed on a particle beam at CERN. With this different configuration we have obtained an improvement on the timing precision of a factor of 1.6-1.7 with respect to a single layer scCVD diamond detector.
△ Less
Submitted 29 December, 2016;
originally announced December 2016.
-
Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System
Authors:
D. Abbaneo,
M. Abbas,
M. Abbrescia,
A. A. Abdelalim,
M. Abi Akl,
W. Ahmed,
W. Ahmed,
P. Altieri,
R. Aly,
C. Asawatangtrakuldee,
A. Ashfaq,
P. Aspell,
Y. Assran,
I. Awan,
S. Bally,
Y. Ban,
S. Banerjee,
P. Barria,
L. Benussi,
V. Bhopatkar,
S. Bianco,
J. Bos,
O. Bouhali,
S. Braibant,
S. Buontempo
, et al. (113 additional authors not shown)
Abstract:
Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \midη\mid < 2.2$ region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips wi…
▽ More
Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \midη\mid < 2.2$ region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips with 455 $μ$rad pitch arranged in eight $η$-sectors. We assembled a full-size GE1/1 prototype of 1m length at Florida Tech and tested it in 20-120 GeV hadron beams at Fermilab using Ar/CO$_{2}$ 70:30 and the RD51 scalable readout system. Four small GEM detectors with 2-D readout and an average measured azimuthal resolution of 36 $μ$rad provided precise reference tracks. Construction of this largest GEM detector built to-date is described. Strip cluster parameters, detection efficiency, and spatial resolution are studied with position and high voltage scans. The plateau detection efficiency is [97.1 $\pm$ 0.2 (stat)]\%. The azimuthal resolution is found to be [123.5 $\pm$ 1.6 (stat)] $μ$rad when operating in the center of the efficiency plateau and using full pulse height information. The resolution can be slightly improved by $\sim$ 10 $μ$rad when correcting for the bias due to discrete readout strips. The CMS upgrade design calls for readout electronics with binary hit output. When strip clusters are formed correspondingly without charge-weighting and with fixed hit thresholds, a position resolution of [136.8 $\pm$ 2.5 stat] $μ$rad is measured, consistent with the expected resolution of strip-pitch/$\sqrt{12}$ = 131.3 $μ$rad. Other $η$-sectors of the detector show similar response and performance.
△ Less
Submitted 8 December, 2014; v1 submitted 30 November, 2014;
originally announced December 2014.
-
LHC Optics Measurement with Proton Tracks Detected by the Roman Pots of the TOTEM Experiment
Authors:
The TOTEM Collaboration,
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
V. Berardi,
M. Berretti,
E. Bossini,
U. Bottigli,
M. Bozzo,
E. Brücken,
A. Buzzo,
F. S. Cafagna,
M. G. Catanesi,
C. Covault,
M. Csanád,
T. Csörgő,
M. Deile,
M. Doubek,
K. Eggert,
V. Eremin,
F. Ferro,
A. Fiergolski,
F. Garcia
, et al. (54 additional authors not shown)
Abstract:
Precise knowledge of the beam optics at the LHC is crucial to fulfil the physics goals of the TOTEM experiment, where the kinematics of the scattered protons is reconstructed with the near-beam telescopes -- so-called Roman Pots (RP). Before being detected, the protons' trajectories are influenced by the magnetic fields of the accelerator lattice. Thus precise understanding of the proton transport…
▽ More
Precise knowledge of the beam optics at the LHC is crucial to fulfil the physics goals of the TOTEM experiment, where the kinematics of the scattered protons is reconstructed with the near-beam telescopes -- so-called Roman Pots (RP). Before being detected, the protons' trajectories are influenced by the magnetic fields of the accelerator lattice. Thus precise understanding of the proton transport is of key importance for the experiment. A novel method of optics evaluation is proposed which exploits kinematical distributions of elastically scattered protons observed in the RPs. Theoretical predictions, as well as Monte Carlo studies, show that the residual uncertainty of this optics estimation method is smaller than 0.25 percent.
△ Less
Submitted 2 June, 2014;
originally announced June 2014.
-
Performance of the TOTEM Detectors at the LHC
Authors:
TOTEM Collaboration,
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
M. G. Bagliesi,
V. Berardi,
M. Berretti,
E. Bossini,
U. Bottigli,
M. Bozzo,
E. Brücken,
A. Buzzo,
F. S. Cafagna,
M. G. Catanesi,
R. Cecchi,
C. Covault,
M. Csanád,
T. Csörgő,
M. Deile,
M. Doubek,
K. Eggert,
V. Eremin,
F. Ferro
, et al. (57 additional authors not shown)
Abstract:
The TOTEM Experiment is designed to measure the total proton-proton cross-section with the luminosity-independent method and to study elastic and diffractive pp scattering at the LHC. To achieve optimum forward coverage for charged particles emitted by the pp collisions in the interaction point IP5, two tracking telescopes, T1 and T2, are installed on each side of the IP in the pseudorapidity regi…
▽ More
The TOTEM Experiment is designed to measure the total proton-proton cross-section with the luminosity-independent method and to study elastic and diffractive pp scattering at the LHC. To achieve optimum forward coverage for charged particles emitted by the pp collisions in the interaction point IP5, two tracking telescopes, T1 and T2, are installed on each side of the IP in the pseudorapidity region 3.1 < = |eta | < = 6.5, and special movable beam-pipe insertions - called Roman Pots (RP) - are placed at distances of +- 147 m and +- 220 m from IP5. This article describes in detail the working of the TOTEM detector to produce physics results in the first three years of operation and data taking at the LHC.
△ Less
Submitted 10 October, 2013;
originally announced October 2013.
-
Beam Test Results for New Full-scale GEM Prototypes for a Future Upgrade of the CMS High-eta Muon System
Authors:
D. Abbaneo,
M. Abbrescia,
C. Armagnaud,
P. Aspell,
Y. Assran,
Y. Ban,
S. Bally,
L. Benussi,
U. Berzano,
S. Bianco,
J. Bos,
K. Bunkowski,
J. Cai,
J. P. Chatelain,
J. Christiansen,
S. Colafranceschi,
A. Colaleo,
A. Conde Garcia,
E. David,
G. de Robertis,
R. De Oliveira,
S. Duarte Pinto,
S. Ferry,
F. Formenti,
L. Franconi
, et al. (34 additional authors not shown)
Abstract:
The CMS GEM collaboration is considering Gas Electron Multipliers (GEMs) for upgrading the CMS forward muon system in the 1.5<|eta|<2.4 endcap region. GEM detectors can provide precision tracking and fast trigger information. They would improve the CMS muon trigger and muon momentum resolution and provide missing redundancy in the high-eta region. Employing a new faster construction and assembly t…
▽ More
The CMS GEM collaboration is considering Gas Electron Multipliers (GEMs) for upgrading the CMS forward muon system in the 1.5<|eta|<2.4 endcap region. GEM detectors can provide precision tracking and fast trigger information. They would improve the CMS muon trigger and muon momentum resolution and provide missing redundancy in the high-eta region. Employing a new faster construction and assembly technique, we built four full-scale Triple-GEM muon detectors for the inner ring of the first muon endcap station. We plan to install these or further improved versions in CMS during the first long LHC shutdown in 2013/14 for continued testing. These detectors are designed for the stringent rate and resolution requirements in the increasingly hostile environments expected at CMS after the second long LHC shutdown in 2018/19. The new prototypes were studied in muon/pion beams at the CERN SPS. We discuss our experience with constructing the new full-scale production prototypes and present preliminary performance results from the beam test. We also tested smaller Triple-GEM prototypes with zigzag readout strips with 2 mm pitch in these beams and measured a spatial resolution of 73 microns. This readout offers a potential reduction of channel count and consequently electronics cost for this system while maintaining high spatial resolution.
△ Less
Submitted 16 November, 2012;
originally announced November 2012.
-
Construction and Performance of Large-Area Triple-GEM Prototypes for Future Upgrades of the CMS Forward Muon System
Authors:
M. Tytgat,
A. Marinov,
N. Zaganidis,
Y. Ban,
J. Cai,
H. Teng,
A. Mohapatra,
T. Moulik,
M. Abbrescia,
A. Colaleo,
G. de Robertis,
F. Loddo,
M. Maggi,
S. Nuzzo,
S. A. Tupputi,
L. Benussi,
S. Bianco,
S. Colafranceschi,
D. Piccolo,
G. Raffone,
G. Saviano,
M. G. Bagliesi,
R. Cecchi,
G. Magazzu,
E. Oliveri
, et al. (34 additional authors not shown)
Abstract:
At present, part of the forward RPC muon system of the CMS detector at the CERN LHC remains uninstrumented in the high-ηregion. An international collaboration is investigating the possibility of covering the 1.6 < |η| < 2.4 region of the muon endcaps with large-area triple-GEM detectors. Given their good spatial resolution, high rate capability, and radiation hardness, these micro-pattern gas dete…
▽ More
At present, part of the forward RPC muon system of the CMS detector at the CERN LHC remains uninstrumented in the high-ηregion. An international collaboration is investigating the possibility of covering the 1.6 < |η| < 2.4 region of the muon endcaps with large-area triple-GEM detectors. Given their good spatial resolution, high rate capability, and radiation hardness, these micro-pattern gas detectors are an appealing option for simultaneously enhancing muon tracking and triggering capabilities in a future upgrade of the CMS detector. A general overview of this feasibility study will be presented. The design and construction of small (10\times10 cm2) and full-size trapezoidal (1\times0.5 m2) triple-GEM prototypes will be described. During detector assembly, different techniques for stretching the GEM foils were tested. Results from measurements with x-rays and from test beam campaigns at the CERN SPS will be shown for the small and large prototypes. Preliminary simulation studies on the expected muon reconstruction and trigger performances of this proposed upgraded muon system will be reported.
△ Less
Submitted 30 November, 2011;
originally announced November 2011.
-
Test beam results of the GE1/1 prototype for a future upgrade of the CMS high-$η$ muon system
Authors:
D. Abbaneo,
M. Abbrescia,
C. Armagnaud,
P. Aspell,
M. G. Bagliesi,
Y. Ban,
S. Bally,
L. Benussi,
U. Berzano,
S. Bianco,
J. Bos,
K. Bunkowski,
J. Cai,
R. Cecchi,
J. P. Chatelain,
J. Christiansen,
S. Colafranceschi,
A. Colaleo,
A. Conde Garcia,
E. David,
G. de Robertis,
R. De Oliveira,
S. Duarte Pinto,
S. Ferry,
F. Formenti
, et al. (33 additional authors not shown)
Abstract:
Gas Electron Multipliers (GEM) are an interesting technology under consideration for the future upgrade of the forward region of the CMS muon system, specifically in the $1.6<| η|<2.4$ endcap region. With a sufficiently fine segmentation GEMs can provide precision tracking as well as fast trigger information. The main objective is to contribute to the improvement of the CMS muon trigger. The const…
▽ More
Gas Electron Multipliers (GEM) are an interesting technology under consideration for the future upgrade of the forward region of the CMS muon system, specifically in the $1.6<| η|<2.4$ endcap region. With a sufficiently fine segmentation GEMs can provide precision tracking as well as fast trigger information. The main objective is to contribute to the improvement of the CMS muon trigger. The construction of large-area GEM detectors is challenging both from the technological and production aspects. In view of the CMS upgrade we have designed and built the largest full-size Triple-GEM muon detector, which is able to meet the stringent requirements given the hostile environment at the high-luminosity LHC. Measurements were performed during several test beam campaigns at the CERN SPS in 2010 and 2011. The main issues under study are efficiency, spatial resolution and timing performance with different inter-electrode gap configurations and gas mixtures. In this paper results of the performance of the prototypes at the beam tests will be discussed.
△ Less
Submitted 30 November, 2011; v1 submitted 21 November, 2011;
originally announced November 2011.
-
Characterization of GEM Detectors for Application in the CMS Muon Detection System
Authors:
D. Abbaneo,
S. Bally,
H. Postema,
A. Conde Garcia,
J. P. Chatelain,
G. Faber,
L. Ropelewski,
E. David,
S. Duarte Pinto,
G. Croci,
M. Alfonsi,
M. van Stenis,
A. Sharma,
L. Benussi,
S. Bianco,
S. Colafranceschi,
D. Piccolo,
G. Saviano,
N. Turini,
E. Oliveri,
G. Magazzu',
A. Marinov,
M. Tytgat,
N. Zaganidis,
M. Hohlmann
, et al. (4 additional authors not shown)
Abstract:
The muon detection system of the Compact Muon Solenoid experiment at the CERN Large Hadron Collider is based on different technologies for muon tracking and triggering. In particular, the muon system in the endcap disks of the detector consists of Resistive Plate Chambers for triggering and Cathode Strip Chambers for tracking. At present, the endcap muon system is only partially instrumented with…
▽ More
The muon detection system of the Compact Muon Solenoid experiment at the CERN Large Hadron Collider is based on different technologies for muon tracking and triggering. In particular, the muon system in the endcap disks of the detector consists of Resistive Plate Chambers for triggering and Cathode Strip Chambers for tracking. At present, the endcap muon system is only partially instrumented with the very forward detector region remaining uncovered. In view of a possible future extension of the muon endcap system, we report on a feasibility study on the use of Micro-Pattern Gas Detectors, in particular Gas Electron Multipliers, for both muon triggering and tracking. Results on the construction and characterization of small tripleGas Electron Multiplier prototype detectors are presented.
△ Less
Submitted 16 December, 2010;
originally announced December 2010.
-
Construction of the first full-size GEM-based prototype for the CMS high-$η$ muon system
Authors:
D. Abbaneo,
S. Bally,
H. Postema,
A. Conde Garcia,
J. P. Chatelain,
G. Faber,
L. Ropelewski,
S. Duarte Pinto,
G. Croci,
M. Alfonsi,
M. Van Stenis,
A. Sharma,
L. Benussi,
S. Bianco,
S. Colafranceschi,
F. Fabbri,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
G. Raffone,
A. Russo,
G. Saviano,
A. Marinov,
M. Tytgat,
N. Zaganidis
, et al. (10 additional authors not shown)
Abstract:
In view of a possible extension of the forward CMS muon detector system and future LHC luminosity upgrades, Micro-Pattern Gas Detectors (MPGDs) are an appealing technology. They can simultaneously provide precision tracking and fast trigger information, as well as sufficiently fine segmentation to cope with high particle rates in the high-eta region at LHC and its future upgrades. We report on the…
▽ More
In view of a possible extension of the forward CMS muon detector system and future LHC luminosity upgrades, Micro-Pattern Gas Detectors (MPGDs) are an appealing technology. They can simultaneously provide precision tracking and fast trigger information, as well as sufficiently fine segmentation to cope with high particle rates in the high-eta region at LHC and its future upgrades. We report on the design and construction of a full-size prototype for the CMS endcap system, the largest Triple-GEM detector built to-date. We present details on the 3D modeling of the detector geometry, the implementation of the readout strips and electronics, and the detector assembly procedure.
△ Less
Submitted 9 December, 2010; v1 submitted 7 December, 2010;
originally announced December 2010.
-
A triple-GEM telescope for the TOTEM experiment
Authors:
S. Lami,
G. Latino,
E. Oliveri,
L. Ropelewski,
N. Turini
Abstract:
The TOTEM experiment at LHC has chosen the triple Gas Electron Multiplier (GEM) technology for its T2 telescope which will provide charged track reconstruction in the rapidity range 5.3<|eta|<6.5 and a fully inclusive trigger for diffractive events. GEMs are gas-filled detectors that have the advantageous decoupling of the charge amplification structure from the charge collection and readout str…
▽ More
The TOTEM experiment at LHC has chosen the triple Gas Electron Multiplier (GEM) technology for its T2 telescope which will provide charged track reconstruction in the rapidity range 5.3<|eta|<6.5 and a fully inclusive trigger for diffractive events. GEMs are gas-filled detectors that have the advantageous decoupling of the charge amplification structure from the charge collection and readout structure. Furthermore, they combine good spatial resolution with very high rate capability and a good resistance to radiation. Results from a detailed T2 GEM simulation and from laboratory tests on a final design detector performed at CERN are presented.
△ Less
Submitted 18 November, 2006;
originally announced November 2006.
-
The CDF Calorimetry Upgrade for Run IIb
Authors:
S. Kuhlmann,
H. Frisch,
M. Cordelli,
J. Huston,
R. Miller,
S. Lami,
R. Paoletti,
N. Turini,
M. Iori,
D. Toback,
T. Ukegawa
Abstract:
The physics program at the Fermilab Tevatron Collider will continue to explore the high energy frontier of particle physics until the commissioning of the LHC at CERN. The luminosity increase provided by the Main Injector will require upgrades beyond those implemented for the first stage (Run IIa) of the Tevatron's Run II physics program. The upgrade of the CDF calorimetry includes: 1) the repla…
▽ More
The physics program at the Fermilab Tevatron Collider will continue to explore the high energy frontier of particle physics until the commissioning of the LHC at CERN. The luminosity increase provided by the Main Injector will require upgrades beyond those implemented for the first stage (Run IIa) of the Tevatron's Run II physics program. The upgrade of the CDF calorimetry includes: 1) the replacement of the slow gas detectors on the front face of the Central Calorimeter with a faster scintillator version which has a better segmentation, and 2) the addition of timing information to both the Central and EndPlug Electromagnetic Calorimeters to filter out cosmic ray and beam related backgrounds.
△ Less
Submitted 30 October, 2003;
originally announced October 2003.