Skip to main content

Showing 1–13 of 13 results for author: Turini, N

Searching in archive physics. Search in all archives.
.
  1. arXiv:1702.05180  [pdf, other

    physics.ins-det hep-ex

    Test of UFSD Silicon Detectors for the TOTEM Upgrade Project

    Authors: R. Arcidiacono, M. Berretti, E. Bossini, M. Bozzo, N. Cartiglia, M. Ferrero, V. Georgiev, T. Isidori, R. Linhart, N. Minafra, M. M. Obertino, V. Sola, N. Turini

    Abstract: This paper describes the performance of a prototype timing detector, based on 50 micrometer thick Ultra Fast Silicon Detector, as measured in a beam test using a 180 GeV/c momentum pion beam. The dependence of the time precision on the pixel capacitance and the bias voltage is investigated here. A timing precision from 30 ps to 100 ps, depending on the pixel capacitance, has been measured at a bia… ▽ More

    Submitted 16 February, 2017; originally announced February 2017.

  2. arXiv:1701.05227  [pdf, other

    physics.ins-det hep-ex

    Diamond Detectors for the TOTEM Timing Upgrade

    Authors: TOTEM Collaboration, G. Antchev, P. Aspell, I. Atanassov, V. Avati, J. Baechler, V. Berardi, M. Berretti, E. Bossini, U. Bottigli, M. Bozzo, P. Broulím, A. Buzzo, F. S. Cafagna, M. G. Catanesi, M. Csanád, T. Csörgő, M. Deile, F. De Leonardis, A. D'Orazio, M. Doubek, K. Eggert, V. Eremin, F. Ferro, A. Fiergolski , et al. (58 additional authors not shown)

    Abstract: This paper describes the design and the performance of the timing detector developed by the TOTEM Collaboration for the Roman Pots (RPs) to measure the Time-Of-Flight (TOF) of the protons produced in central diffractive interactions at the LHC. The measurement of the TOF of the protons allows the determination of the longitudinal position of the proton interaction vertex and its association with o… ▽ More

    Submitted 18 January, 2017; originally announced January 2017.

    Comments: 26 pages, 18 figures, 2 tables, submitted for publication to JINST

    Report number: CERN-PH-EP-2016-317

    Journal ref: JINST 12 (2017) no.03, P03007

  3. Timing Performance of a Double Layer Diamond Detector

    Authors: M. Berretti, E. Bossini, M. Bozzo, V. Georgiev, T. Isidori, R. Linhart, N. Turini

    Abstract: In order to improve the time precision of detectors based on diamonds sensors we have built a detector with two scCVD layers connected in parallel to the same amplifier. This note describes the design and the first measurements of such a prototype performed on a particle beam at CERN. With this different configuration we have obtained an improvement on the timing precision of a factor of 1.6-1.7 w… ▽ More

    Submitted 29 December, 2016; originally announced December 2016.

  4. arXiv:1412.0228  [pdf, other

    physics.ins-det

    Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System

    Authors: D. Abbaneo, M. Abbas, M. Abbrescia, A. A. Abdelalim, M. Abi Akl, W. Ahmed, W. Ahmed, P. Altieri, R. Aly, C. Asawatangtrakuldee, A. Ashfaq, P. Aspell, Y. Assran, I. Awan, S. Bally, Y. Ban, S. Banerjee, P. Barria, L. Benussi, V. Bhopatkar, S. Bianco, J. Bos, O. Bouhali, S. Braibant, S. Buontempo , et al. (113 additional authors not shown)

    Abstract: Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \midη\mid < 2.2$ region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips wi… ▽ More

    Submitted 8 December, 2014; v1 submitted 30 November, 2014; originally announced December 2014.

    Comments: 8 pages, 32 figures, submitted to Proc. 2014 IEEE Nucl. Sci. Symposium, Seattle, WA, reference added

  5. arXiv:1406.0546  [pdf, ps, other

    physics.acc-ph hep-ex

    LHC Optics Measurement with Proton Tracks Detected by the Roman Pots of the TOTEM Experiment

    Authors: The TOTEM Collaboration, G. Antchev, P. Aspell, I. Atanassov, V. Avati, J. Baechler, V. Berardi, M. Berretti, E. Bossini, U. Bottigli, M. Bozzo, E. Brücken, A. Buzzo, F. S. Cafagna, M. G. Catanesi, C. Covault, M. Csanád, T. Csörgő, M. Deile, M. Doubek, K. Eggert, V. Eremin, F. Ferro, A. Fiergolski, F. Garcia , et al. (54 additional authors not shown)

    Abstract: Precise knowledge of the beam optics at the LHC is crucial to fulfil the physics goals of the TOTEM experiment, where the kinematics of the scattered protons is reconstructed with the near-beam telescopes -- so-called Roman Pots (RP). Before being detected, the protons' trajectories are influenced by the magnetic fields of the accelerator lattice. Thus precise understanding of the proton transport… ▽ More

    Submitted 2 June, 2014; originally announced June 2014.

    Comments: 20 pages, 11 figures, 5 figures, to be submitted to New J. Phys

    Report number: CERN-PH-EP-2014-066

  6. arXiv:1310.2908  [pdf, ps, other

    physics.ins-det hep-ex

    Performance of the TOTEM Detectors at the LHC

    Authors: TOTEM Collaboration, G. Antchev, P. Aspell, I. Atanassov, V. Avati, J. Baechler, M. G. Bagliesi, V. Berardi, M. Berretti, E. Bossini, U. Bottigli, M. Bozzo, E. Brücken, A. Buzzo, F. S. Cafagna, M. G. Catanesi, R. Cecchi, C. Covault, M. Csanád, T. Csörgő, M. Deile, M. Doubek, K. Eggert, V. Eremin, F. Ferro , et al. (57 additional authors not shown)

    Abstract: The TOTEM Experiment is designed to measure the total proton-proton cross-section with the luminosity-independent method and to study elastic and diffractive pp scattering at the LHC. To achieve optimum forward coverage for charged particles emitted by the pp collisions in the interaction point IP5, two tracking telescopes, T1 and T2, are installed on each side of the IP in the pseudorapidity regi… ▽ More

    Submitted 10 October, 2013; originally announced October 2013.

    Comments: 40 pages, 31 figures, submitted to Int. J. Mod. Phys. A

    Report number: CERN-PH-EP-2013-173

    Journal ref: Int. J. Mod. Phys. A 28, 1330046 (2013)

  7. arXiv:1211.3939  [pdf, ps, other

    physics.ins-det

    Beam Test Results for New Full-scale GEM Prototypes for a Future Upgrade of the CMS High-eta Muon System

    Authors: D. Abbaneo, M. Abbrescia, C. Armagnaud, P. Aspell, Y. Assran, Y. Ban, S. Bally, L. Benussi, U. Berzano, S. Bianco, J. Bos, K. Bunkowski, J. Cai, J. P. Chatelain, J. Christiansen, S. Colafranceschi, A. Colaleo, A. Conde Garcia, E. David, G. de Robertis, R. De Oliveira, S. Duarte Pinto, S. Ferry, F. Formenti, L. Franconi , et al. (34 additional authors not shown)

    Abstract: The CMS GEM collaboration is considering Gas Electron Multipliers (GEMs) for upgrading the CMS forward muon system in the 1.5<|eta|<2.4 endcap region. GEM detectors can provide precision tracking and fast trigger information. They would improve the CMS muon trigger and muon momentum resolution and provide missing redundancy in the high-eta region. Employing a new faster construction and assembly t… ▽ More

    Submitted 16 November, 2012; originally announced November 2012.

    Comments: 5 pages, 9 figures, submitted to Proc. 2012 IEEE Nucl. Sci. Symposium, Anaheim, CA

  8. arXiv:1111.7249  [pdf, ps, other

    physics.ins-det hep-ex

    Construction and Performance of Large-Area Triple-GEM Prototypes for Future Upgrades of the CMS Forward Muon System

    Authors: M. Tytgat, A. Marinov, N. Zaganidis, Y. Ban, J. Cai, H. Teng, A. Mohapatra, T. Moulik, M. Abbrescia, A. Colaleo, G. de Robertis, F. Loddo, M. Maggi, S. Nuzzo, S. A. Tupputi, L. Benussi, S. Bianco, S. Colafranceschi, D. Piccolo, G. Raffone, G. Saviano, M. G. Bagliesi, R. Cecchi, G. Magazzu, E. Oliveri , et al. (34 additional authors not shown)

    Abstract: At present, part of the forward RPC muon system of the CMS detector at the CERN LHC remains uninstrumented in the high-ηregion. An international collaboration is investigating the possibility of covering the 1.6 < |η| < 2.4 region of the muon endcaps with large-area triple-GEM detectors. Given their good spatial resolution, high rate capability, and radiation hardness, these micro-pattern gas dete… ▽ More

    Submitted 30 November, 2011; originally announced November 2011.

    Comments: 7 pages, 25 figures, submitted for publication in conference record of the 2011 IEEE Nuclear Science Symposium, Valencia, Spain

    Report number: RD51-Note-2011-012

  9. arXiv:1111.4883  [pdf, ps, other

    physics.ins-det hep-ex

    Test beam results of the GE1/1 prototype for a future upgrade of the CMS high-$η$ muon system

    Authors: D. Abbaneo, M. Abbrescia, C. Armagnaud, P. Aspell, M. G. Bagliesi, Y. Ban, S. Bally, L. Benussi, U. Berzano, S. Bianco, J. Bos, K. Bunkowski, J. Cai, R. Cecchi, J. P. Chatelain, J. Christiansen, S. Colafranceschi, A. Colaleo, A. Conde Garcia, E. David, G. de Robertis, R. De Oliveira, S. Duarte Pinto, S. Ferry, F. Formenti , et al. (33 additional authors not shown)

    Abstract: Gas Electron Multipliers (GEM) are an interesting technology under consideration for the future upgrade of the forward region of the CMS muon system, specifically in the $1.6<| η|<2.4$ endcap region. With a sufficiently fine segmentation GEMs can provide precision tracking as well as fast trigger information. The main objective is to contribute to the improvement of the CMS muon trigger. The const… ▽ More

    Submitted 30 November, 2011; v1 submitted 21 November, 2011; originally announced November 2011.

  10. arXiv:1012.3675  [pdf, ps, other

    physics.ins-det hep-ex

    Characterization of GEM Detectors for Application in the CMS Muon Detection System

    Authors: D. Abbaneo, S. Bally, H. Postema, A. Conde Garcia, J. P. Chatelain, G. Faber, L. Ropelewski, E. David, S. Duarte Pinto, G. Croci, M. Alfonsi, M. van Stenis, A. Sharma, L. Benussi, S. Bianco, S. Colafranceschi, D. Piccolo, G. Saviano, N. Turini, E. Oliveri, G. Magazzu', A. Marinov, M. Tytgat, N. Zaganidis, M. Hohlmann , et al. (4 additional authors not shown)

    Abstract: The muon detection system of the Compact Muon Solenoid experiment at the CERN Large Hadron Collider is based on different technologies for muon tracking and triggering. In particular, the muon system in the endcap disks of the detector consists of Resistive Plate Chambers for triggering and Cathode Strip Chambers for tracking. At present, the endcap muon system is only partially instrumented with… ▽ More

    Submitted 16 December, 2010; originally announced December 2010.

    Comments: 7 pages, 19 figures, submitted for publication in conference record of the 2010 IEEE Nuclear Science Symposium, Knoxville, TN

    Report number: RD51-Note-2010-005

  11. arXiv:1012.1524  [pdf, ps, other

    physics.ins-det hep-ex

    Construction of the first full-size GEM-based prototype for the CMS high-$η$ muon system

    Authors: D. Abbaneo, S. Bally, H. Postema, A. Conde Garcia, J. P. Chatelain, G. Faber, L. Ropelewski, S. Duarte Pinto, G. Croci, M. Alfonsi, M. Van Stenis, A. Sharma, L. Benussi, S. Bianco, S. Colafranceschi, F. Fabbri, L. Passamonti, D. Piccolo, D. Pierluigi, G. Raffone, A. Russo, G. Saviano, A. Marinov, M. Tytgat, N. Zaganidis , et al. (10 additional authors not shown)

    Abstract: In view of a possible extension of the forward CMS muon detector system and future LHC luminosity upgrades, Micro-Pattern Gas Detectors (MPGDs) are an appealing technology. They can simultaneously provide precision tracking and fast trigger information, as well as sufficiently fine segmentation to cope with high particle rates in the high-eta region at LHC and its future upgrades. We report on the… ▽ More

    Submitted 9 December, 2010; v1 submitted 7 December, 2010; originally announced December 2010.

    Comments: 5 pages, 11 figures, presented by S.Colafranceschi at IEEE 2010 (Knoxville, USA)

    Report number: RD51-NOTE-2010-008, Frascati Preprint LNF - 10 / 24(P)

  12. A triple-GEM telescope for the TOTEM experiment

    Authors: S. Lami, G. Latino, E. Oliveri, L. Ropelewski, N. Turini

    Abstract: The TOTEM experiment at LHC has chosen the triple Gas Electron Multiplier (GEM) technology for its T2 telescope which will provide charged track reconstruction in the rapidity range 5.3<|eta|<6.5 and a fully inclusive trigger for diffractive events. GEMs are gas-filled detectors that have the advantageous decoupling of the charge amplification structure from the charge collection and readout str… ▽ More

    Submitted 18 November, 2006; originally announced November 2006.

    Comments: To appear in the proceedings of 10th Topical Seminar on Innovative Particle and Radiation Detectors (IPRD06), Siena, Italy, October 1-5 2006

    Journal ref: Nucl.Phys.Proc.Suppl.172:231-233,2007

  13. The CDF Calorimetry Upgrade for Run IIb

    Authors: S. Kuhlmann, H. Frisch, M. Cordelli, J. Huston, R. Miller, S. Lami, R. Paoletti, N. Turini, M. Iori, D. Toback, T. Ukegawa

    Abstract: The physics program at the Fermilab Tevatron Collider will continue to explore the high energy frontier of particle physics until the commissioning of the LHC at CERN. The luminosity increase provided by the Main Injector will require upgrades beyond those implemented for the first stage (Run IIa) of the Tevatron's Run II physics program. The upgrade of the CDF calorimetry includes: 1) the repla… ▽ More

    Submitted 30 October, 2003; originally announced October 2003.

    Comments: Presented at `Frontier Detectors for Frontier Physics; 9th Pisa Meeting on Advanced Detectors', Biodola, Italy, 25-31 May 2003. 2 pages

    Journal ref: Nucl.Instrum.Meth.A518:39-41,2004