-
A multiball read-out for the spherical proportional counter
Authors:
A. Giganon,
I. Giomataris,
M. Gros,
I. Katsioulas,
X. F. Navick,
G. Tsiledakis,
I. Savvidis,
A. Dastgheibi-Fard,
A. Brossard
Abstract:
We present a novel concept of proportional gas amplification for the read-out of the spherical proportional counter. The standard single-ball read-out presents limitations for large diameter spherical detectors and high pressure operations. We have developed a multi-ball read-out system which consists of several balls sitting at a fixed distance from the center of the spherical vessel. Such a modu…
▽ More
We present a novel concept of proportional gas amplification for the read-out of the spherical proportional counter. The standard single-ball read-out presents limitations for large diameter spherical detectors and high pressure operations. We have developed a multi-ball read-out system which consists of several balls sitting at a fixed distance from the center of the spherical vessel. Such a module can tune the volume electric field at the desired value and can also provide detector segmentation with individual ball read-out. In the latter case the large volume of the vessel becomes a spherical time projection chamber with 3D capabilities.
△ Less
Submitted 28 July, 2017;
originally announced July 2017.
-
Fast Timing for High-Rate Environments with Micromegas
Authors:
Thomas Papaevangelou,
Daniel Desforge,
Esther Ferrer-Ribas,
Ioannis Giomataris,
Cyprien Godinot,
Diego Gonzalez Diaz,
Thomas Gustavsson,
Mariam Kebbiri,
Eraldo Oliveri,
Filippo Resnati,
Leszek Ropelewski,
Georgios Tsiledakis,
Rob Veenhof,
Sebastian White
Abstract:
The current state of the art in fast timing resolution for existing experiments is of the order of 100 ps on the time of arrival of both charged particles and electromagnetic showers. Current R&D on charged particle timing is approaching the level of 10 ps but is not primarily directed at sustained performance at high rates and under high radiation (as would be needed for HL-LHC pileup mitigation)…
▽ More
The current state of the art in fast timing resolution for existing experiments is of the order of 100 ps on the time of arrival of both charged particles and electromagnetic showers. Current R&D on charged particle timing is approaching the level of 10 ps but is not primarily directed at sustained performance at high rates and under high radiation (as would be needed for HL-LHC pileup mitigation). We demonstrate a Micromegas based solution to reach this level of performance. The Micromegas acts as a photomultiplier coupled to a Cerenkov-radiator front window, which produces sufficient UV photons to convert the ~100 ps single-photoelectron jitter into a timing response of the order of 10-20 ps per incident charged particle. A prototype has been built in order to demonstrate this performance. The first laboratory tests with a pico-second laser have shown a time resolution of the order of 27 ps for ~50 primary photoelectrons, using a bulk Micromegas readout.
△ Less
Submitted 12 January, 2016; v1 submitted 1 January, 2016;
originally announced January 2016.
-
Neutron spectroscopy with the Spherical Proportional Counter
Authors:
E. Bougamont,
A. Dastgheibi,
J. Derre,
J. Galan,
G. Gerbier,
I. Giomataris,
M. Gros,
I. Katsioulas,
D. Jourde,
P. Magnier,
X. F. Navick,
T. Papaevangelou,
I. Savvidis,
G. Tsiledakis
Abstract:
A novel large volume spherical proportional counter, recently developed, is used for neutron measurements. Gas mixtures of $N_{2}$ with $C_{2}H_{6}$ and pure $N_{2}$ are studied for thermal and fast neutron detection, providing a new way for the neutron spectroscopy. The neutrons are detected via the ${}^{14}N(n, p)C^{14}$ and ${}^{14}N(n, α)B^{11}$ reactions. Here we provide studies of the optimu…
▽ More
A novel large volume spherical proportional counter, recently developed, is used for neutron measurements. Gas mixtures of $N_{2}$ with $C_{2}H_{6}$ and pure $N_{2}$ are studied for thermal and fast neutron detection, providing a new way for the neutron spectroscopy. The neutrons are detected via the ${}^{14}N(n, p)C^{14}$ and ${}^{14}N(n, α)B^{11}$ reactions. Here we provide studies of the optimum gas mixture, the gas pressure and the most appropriate high voltage supply on the sensor of the detector in order to achieve the maximum amplification and better resolution. The detector is tested for thermal and fast neutrons detection with a ${}^{252}Cf$ and a ${}^{241}Am-{}^{9}Be$ neutron source. The atmospheric neutrons are successfully measured from thermal up to several MeV, well separated from the cosmic ray background. A comparison of the spherical proportional counter with the current available neutron counters is also given.
△ Less
Submitted 19 September, 2017; v1 submitted 14 December, 2015;
originally announced December 2015.
-
Background optimization for a new spherical gas detector for very light WIMP detection
Authors:
Ali Dastgheibi-Fard,
I. Giomataris,
G. Gerbierb,
J. Derree,
M. Gros,
P. Magnier,
D. Jourde,
E . Bougamont,
X-F. Navick,
T. Papaevangelou,
J. Galan,
G. Tsiledakis,
F. Piquemal,
M. Zampaolo,
P. Loaiza,
I. Savvidis
Abstract:
The Spherical gaseous detector (or Spherical Proportional Counter, SPC) is a novel type of par- ticle detector, with a broad range of applications. Its main features include a very low energy threshold independent of the volume (due to its very low capacitance), a good energy resolution, robustness and a single detection readout channel, in its simplest version. Applications range from radon emana…
▽ More
The Spherical gaseous detector (or Spherical Proportional Counter, SPC) is a novel type of par- ticle detector, with a broad range of applications. Its main features include a very low energy threshold independent of the volume (due to its very low capacitance), a good energy resolution, robustness and a single detection readout channel, in its simplest version. Applications range from radon emanation gas monitoring, neutron flux and gamma counting and spectroscopy to dark matter searches, in particular low mass WIMPs and coherent neutrino scattering measure- ment. Laboratories interested in these various applications share expertise within the NEWS (New Experiments With Sphere) network. SEDINE, a low background prototype installed at underground site of Laboratoire Souterrain de Modane is currently being operated and aims at measuring events at very low energy threshold, around 100 eV. We will present the energy cali- bration with 37Ar, the surface background reduction, the measurement of detector background at sub-keV energies, and show anticipated sensitivities for light dark matter search.
△ Less
Submitted 29 November, 2014;
originally announced December 2014.
-
NEWS : a new spherical gas detector for very low mass WIMP detection
Authors:
G. Gerbier,
I. Giomataris,
P. Magnier,
A. Dastgheibi,
M. Gros,
D. Jourde,
E. Bougamont,
X. F. Navick,
T. Papaevangelou,
J. Galan,
J. Derre,
I. Savvidis,
G. Tsiledakis
Abstract:
The main characteristics of a new concept of spherical gaseous detectors, with some details on its operation are first given. The very low energy threshold of such detector has led to investigations of its potential performance for dark matter particle searches, in particular low mass WIMP's : original methods for energy and fiducial volume calibration and background rejection are described and pr…
▽ More
The main characteristics of a new concept of spherical gaseous detectors, with some details on its operation are first given. The very low energy threshold of such detector has led to investigations of its potential performance for dark matter particle searches, in particular low mass WIMP's : original methods for energy and fiducial volume calibration and background rejection are described and preliminary results obtained with a low radioactivity prototype operated in Laboratoire Souterrain de Modane ("Frejus" lab) are presented. Typical expected sensitivities in cross section for low mass WIMP's are also shown, and other applications briefly discussed.
△ Less
Submitted 30 January, 2014;
originally announced January 2014.
-
Ultra low energy results and their impact to dark matter and low energy neutrino physics
Authors:
E. Bougamont,
P. Colas,
J. Derre,
I. Giomataris,
G. Gerbier,
M. Gros,
P. Magnier,
X. F. Navick,
P. Salin,
I. Savvidis,
G. Tsiledakis,
J. D. Vergados
Abstract:
We present ultra low energy results taken with the novel Spherical Proportional Counter. The energy threshold has been pushed down to about 25 eV and single electrons are clearly collected and detected. To reach such performance low energy calibration systems have been successfully developed: - A pulsed UV lamp extracting photoelectrons from the inner surface of the detector - Various radioactiv…
▽ More
We present ultra low energy results taken with the novel Spherical Proportional Counter. The energy threshold has been pushed down to about 25 eV and single electrons are clearly collected and detected. To reach such performance low energy calibration systems have been successfully developed: - A pulsed UV lamp extracting photoelectrons from the inner surface of the detector - Various radioactive sources allowing low energy peaks through fluorescence processes. The bench mark result is the observation of a well resolved peak at 270 eV due to carbon fluorescence which is unique performance for such large-massive detector. It opens a new window in dark matter and low energy neutrino search and may allow detection of neutrinos from a nuclear reactor or from supernova via neutrino-nucleus elastic scattering
△ Less
Submitted 20 October, 2010;
originally announced October 2010.
-
Drift velocity and gain in argon- and xenon-based mixtures
Authors:
A. Andronic,
S. Biagi,
P. Braun-Munzinger,
C. Garabatos,
G. Tsiledakis
Abstract:
We present measurements of drift velocities and gains in gas mixtures based on Ar and Xe, with CO2, CH4, and N2 as quenchers, and compare them with calculations. In particular, we show the dependence of Ar- and Xe-CO2 drift velocities and gains on the amount of nitrogen contamination in the gas, which in real experiments may build up through leaks. A quantification of the Penning mechanism which…
▽ More
We present measurements of drift velocities and gains in gas mixtures based on Ar and Xe, with CO2, CH4, and N2 as quenchers, and compare them with calculations. In particular, we show the dependence of Ar- and Xe-CO2 drift velocities and gains on the amount of nitrogen contamination in the gas, which in real experiments may build up through leaks. A quantification of the Penning mechanism which contributes to the Townsend coefficients of a given gas mixture is proposed.
△ Less
Submitted 9 February, 2004;
originally announced February 2004.