-
The LHCb upgrade I
Authors:
LHCb collaboration,
R. Aaij,
A. S. W. Abdelmotteleb,
C. Abellan Beteta,
F. Abudinén,
C. Achard,
T. Ackernley,
B. Adeva,
M. Adinolfi,
P. Adlarson,
H. Afsharnia,
C. Agapopoulou,
C. A. Aidala,
Z. Ajaltouni,
S. Akar,
K. Akiba,
P. Albicocco,
J. Albrecht,
F. Alessio,
M. Alexander,
A. Alfonso Albero,
Z. Aliouche,
P. Alvarez Cartelle,
R. Amalric,
S. Amato
, et al. (1298 additional authors not shown)
Abstract:
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their select…
▽ More
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software.
△ Less
Submitted 17 May, 2023;
originally announced May 2023.
-
Scintillating crystals for the Neutral Particle Spectrometer in Hall C at JLab
Authors:
T. Horn,
V. V. Berdnikov,
S. Ali,
A. Asaturyan,
M. Carmignotto,
J. Crafts,
A. Demarque,
R. Ent,
G. Hull,
H. -S. Ko,
M. Mostafavi,
C. Munoz-Camacho,
A. Mkrtchyan,
H. Mkrtchyan,
T. Nguyen Trung,
I. L. Pegg,
E. Rindel,
A. Somov,
V. Tadevosyan,
R. Trotta,
S. Zhamkochyan,
R. Wang,
S. A. Wood
Abstract:
This paper discusses the quality and performance of currently available PbWO$_4$ crystals of relevance to high-resolution electromagnetic calorimetry, e.g. detectors for the Neutral Particle Spectrometer at Jefferson Lab or those planned for the Electron-Ion Collider. Since the construction of the Compact Muon Solenoid (CMS) at the Large Hadron Collider (LHC) and early PANDA (The antiProton ANnihi…
▽ More
This paper discusses the quality and performance of currently available PbWO$_4$ crystals of relevance to high-resolution electromagnetic calorimetry, e.g. detectors for the Neutral Particle Spectrometer at Jefferson Lab or those planned for the Electron-Ion Collider. Since the construction of the Compact Muon Solenoid (CMS) at the Large Hadron Collider (LHC) and early PANDA (The antiProton ANnihilations at DArmstadt) electromagnetic calorimeter (ECAL) the worldwide availability of high quality PbWO$_4$ production has changed dramatically. We report on our studies of crystal samples from SICCAS/China and CRYTUR/Czech Republic that were produced between 2014 and 2019.
△ Less
Submitted 24 November, 2019;
originally announced November 2019.
-
Design and characterization of a single photoelectron calibration system for the NectarCAM camera of the medium-sized telescopes of the Cherenkov Telescope Array
Authors:
Barbara Biasuzzi,
Kevin Pressard,
Jonathan Biteau,
Brice Geoffroy,
Carlos Domingues Goncalves,
Giulia Hull,
Miktat Imre,
Michael Josselin,
Alain Maroni,
Bernard Mathon,
Lucien Seminor,
Tiina Suomijarvi,
Thi Nguyen Trung,
Laurent Vatrinet,
Patrick Brun,
Sami Caroff,
Stephen Fegan,
Oscar Ferreira,
Pierre Jean,
Sonia Karkar,
Jean-François Olive,
Stéphane Rivoire,
Patrick Sizun,
Floris Thiant,
Adellain Tsiahina
, et al. (2 additional authors not shown)
Abstract:
In this work, we describe the optical properties of the single photoelectron (SPE) calibration system designed for NectarCAM, a camera proposed for the Medium Sized Telescopes (MST) of the Cherenkov Telescope Array (CTA). One of the goals of the SPE system, as integral part of the NectarCAM camera, consists in measuring with high accuracy the gain of its photo-detection chain. The SPE system is ba…
▽ More
In this work, we describe the optical properties of the single photoelectron (SPE) calibration system designed for NectarCAM, a camera proposed for the Medium Sized Telescopes (MST) of the Cherenkov Telescope Array (CTA). One of the goals of the SPE system, as integral part of the NectarCAM camera, consists in measuring with high accuracy the gain of its photo-detection chain. The SPE system is based on a white painted screen where light pulses are injected through a fishtail light guide from a dedicated flasher. The screen - placed 15 mm away from the focal plane - is mounted on an XY motorization that allows movements over all the camera plane. This allows in-situ measurements of the SPE spectra via a complete scan of the 1855 photo-multiplier tubes (PMTs) of NectarCAM. This calibration process will enable the reduction of the systematic uncertainties on the energy reconstruction of $γ$-rays coming from distant astronomical sources and detected by CTA.
△ Less
Submitted 16 October, 2019;
originally announced October 2019.
-
PMm2: large photomultipliers and innovative electronics for the next-generation neutrino experiments
Authors:
B. Genolini,
P. Barrillon,
S. Blin,
J. -E. Campagne,
B. Combettes,
S. Conforti,
A. -G. De-haine,
D. Duchesneau,
F. Dulucq,
N. Dumont-Dayot,
J. Favier,
F. Fouché,
R. Hermel,
C. de La Taille,
G. Martin-Chassard,
T. Nguyen Trung,
C. Périnet,
J. Peyré,
J. Pouthas,
L. Raux,
E. Rindel,
P. Rosier,
J. Tassan-Viol,
W. Wei,
A. Zghiche
Abstract:
The next generation of proton decay and neutrino experiments, the post-SuperKamiokande detectors as those that will take place in megaton size water tanks, will require very large surfaces of photodetection and a large volume of data. Even with large hemispherical photomultiplier tubes, the expected number of channels should reach hundreds of thousands. A funded R&D program to implement a soluti…
▽ More
The next generation of proton decay and neutrino experiments, the post-SuperKamiokande detectors as those that will take place in megaton size water tanks, will require very large surfaces of photodetection and a large volume of data. Even with large hemispherical photomultiplier tubes, the expected number of channels should reach hundreds of thousands. A funded R&D program to implement a solution is presented here. The very large surface of photodetection is segmented in macro pixels made of 16 hemispherical (12 inches) photomultiplier tubes connected to an autonomous front-end which works on a triggerless data acquisition mode. The expected data transmission rate is 5 Mb/s per cable, which can be achieved with existing techniques. This architecture allows to reduce considerably the cost and facilitate the industrialization. This document presents the simulations and measurements which define the requirements for the photomultipliers and the electronics. A proto-type of front-end electronics was successfully tested with 16 photomultiplier tubes supplied by a single high voltage, validating the built-in gain adjustment and the calibration principle. The first tests and calculations on the photomultiplier glass led to the study of a new package optimized for a 10 bar pressure in order to sustain the high underwater pressure.
△ Less
Submitted 17 November, 2008;
originally announced November 2008.