Skip to main content

Showing 1–16 of 16 results for author: Torrioli, G

Searching in archive physics. Search in all archives.
.
  1. arXiv:2401.11846  [pdf

    astro-ph.IM physics.ins-det

    Thermalization of a SQUID chip at cryogenic temperature: Thermal conductance measurement for GE 7031 Varnish Glue, Apiezon N Grease and Rubber Cement between 20 and 200 mK

    Authors: M. D'Andrea, G. Torrioli, C. Macculi, M. Kiviranta

    Abstract: In the context of the ATHENA X-IFU Cryogenic AntiCoincidence Detector (CryoAC) development, we have studied the thermalization properties of a 2mm x 2mm SQUID chip. The chip is glued on a front-end PCB and operated on the cold stage of a dilution refrigerator (TBASE < 20 mK). We performed thermal conductance measurements by using different materials to glue the SQUID chip on the PCB. These have be… ▽ More

    Submitted 22 January, 2024; originally announced January 2024.

    Comments: Accepted for publication in the Journal of Low Temperature Physics for LTD-20 special issue

  2. arXiv:2401.10827  [pdf

    astro-ph.IM physics.ins-det

    The TES-based Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU: a large area silicon microcalorimeter for background particles detection

    Authors: M. D'Andrea, C. Macculi, S. Lotti, L. Piro, A. Argan, G. Minervini, G. Torrioli, F. Chiarello, L. Ferrari Barusso, E. Celasco, G. Gallucci, F. Gatti, D. Grosso, M. Rigano, D. Brienza, E. Cavazzuti, A. Volpe

    Abstract: We are develo** the Cryogenic AntiCoincidence detector (CryoAC) of the ATHENA X-IFU spectrometer. It is a TES-based particle detector aimed to reduce the background of the instrument. Here, we present the result obtained with the last CryoAC single-pixel prototype. It is based on a 1 cm2 silicon absorber sensed by a single 2mm x 1mm Ir/Au TES, featuring an on-chip heater for calibration and diag… ▽ More

    Submitted 19 January, 2024; originally announced January 2024.

    Comments: Accepted for publication in the Journal of Low Temperature Physics for LTD-20 special issue

  3. Frequency-modulated combs via on-chip field enhancement

    Authors: Urban Senica, Alexander Dikopoltsev, Andres Forrer, Sara Cibella, Guido Torrioli, Mattias Beck, Jérôme Faist, Giacomo Scalari

    Abstract: Frequency-modulated (FM) combs feature flat intensity spectra with a linear frequency chirp, useful for metrology and sensing applications. Generating FM combs in semiconductor lasers generally requires a fast saturable gain, usually limited by the intrinsic gain medium properties. Here, we show how a spatial modulation of the laser gain medium can enhance the gain saturation dynamics and nonlinea… ▽ More

    Submitted 17 June, 2023; v1 submitted 2 May, 2023; originally announced May 2023.

    Comments: 9 pages, 6 figures; corrected reference typos

    Journal ref: Laser Photonics Rev. 2023, 2300472

  4. arXiv:2302.07556  [pdf

    quant-ph physics.ins-det

    Step** closer to pulsed single microwave photon detectors for axions search

    Authors: A. D'Elia, A. Rettaroli, S. Tocci, D. Babusci, C. Barone, M. Beretta, B. Buonomo, F. Chiarello, N. Chikhi, D. Di Gioacchino, G. Felici, G. Filatrella, M. Fistul, L. G. Foggetta, C. Gatti, E. Il'ichev, C. Ligi, M. Lisitskiy, G. Maccarrone, F. Mattioli, G. Oelsner, S. Pagano, L. Piersanti, B. Ruggiero, G. Torrioli , et al. (1 additional authors not shown)

    Abstract: Axions detection requires the ultimate sensitivity down to the single photon limit. In the microwave region this corresponds to energies in the yJ range. This extreme sensitivity has to be combined with an extremely low dark count rate, since the probability of axions conversion into microwave photons is supposed to be very low. To face this complicated task, we followed two promising approaches t… ▽ More

    Submitted 15 February, 2023; originally announced February 2023.

  5. arXiv:2211.09422  [pdf

    physics.optics physics.ins-det

    THz optical beat-note detection with a fast Hot Electron Bolometer operating up to 31 GHz

    Authors: G. Torrioli, A. Forrer, M. Beck, P. Carelli, F. Chiarello, J. Faist, A. Gaggero, E. Giovine, F. Martini, U. Senica, R. Leoni, G. Scalari, S. Cibella

    Abstract: We study the performance of an hot-electron bolometer (HEB) operating at THz frequencies based on superconducting niobium nitride films. We report on the voltage response of the detector over a large optical bandwidth carried out with different THz sources. We show that the impulse response of the fully packaged HEB at 7.5 K has a 3 dB cut-off around 2 GHz. Remarkably, detection capability is stil… ▽ More

    Submitted 17 November, 2022; originally announced November 2022.

    Journal ref: Optics Express 31 (10), 15942-15952 (2023)

  6. arXiv:2211.07242  [pdf, other

    physics.optics

    THz optical solitons from dispersion-compensated antenna-coupled planarized ring quantum cascade lasers

    Authors: Paolo Micheletti, Urban Senica, Andres Forrer, Sara Cibella, Guido Torrioli, Martin Frankié, Jérôme Faist, Mattias Beck, Giacomo Scalari

    Abstract: Quantum Cascade Lasers (QCL) constitute an intriguing opportunity for the production of on-chip optical Dissipative Kerr Solitons (DKS): self-organized optical waves which can travel while preserving their shape thanks to the interplay between Kerr effect and dispersion. Originally demonstrated in passive microresonators, DKS were recently observed in mid-IR ring QCL paving the way for their achie… ▽ More

    Submitted 14 November, 2022; originally announced November 2022.

  7. arXiv:2207.06737  [pdf, ps, other

    physics.optics physics.app-ph

    Planarized THz quantum cascade lasers for broadband coherent photonics

    Authors: Urban Senica, Andres Forrer, Tudor Olariu, Paolo Micheletti, Sara Cibella, Guido Torrioli, Mattias Beck, Jérôme Faist, Giacomo Scalari

    Abstract: Recently, there has been a growing interest in integrated THz photonics for various applications in communications, spectroscopy and sensing. We present a new integrated photonic platform based on active and passive elements integrated in a double-metal, high confinement waveguide layout planarized with a low-loss polymer. An extended top metallization results in low waveguide losses and improved… ▽ More

    Submitted 14 July, 2022; originally announced July 2022.

    Comments: 27 pages, 5 figures

    Journal ref: Light Sci Appl 11, 347 (2022)

  8. arXiv:2206.15150  [pdf

    astro-ph.IM physics.ins-det

    ATHENA X-IFU Demonstration Model: First joint operation of the main TES Array and its Cryogenic AntiCoincidence Detector (CryoAC)

    Authors: M. D'Andrea, K. Ravensberg, A. Argan, D. Brienza, S. Lotti, C. Macculi, G. Minervini, L. Piro, G. Torrioli, F. Chiarello, L. Ferrari Barusso, M. Biasotti, G. Gallucci, F. Gatti, M. Rigano, H. Akamatsu, J. Dercksen, L. Gottardi, F. de Groote, R. den Hartog, J. -W. den Herder, R. Hoogeveen, B. Jackson, A. McCalden, S. Rosman , et al. (6 additional authors not shown)

    Abstract: The X-IFU is the cryogenic spectrometer onboard the future ATHENA X-ray observatory. It is based on a large array of TES microcalorimeters, which works in combination with a Cryogenic AntiCoincidence detector (CryoAC). This is necessary to reduce the particle background level thus enabling part of the mission science goals. Here we present the first joint test of X-IFU TES array and CryoAC Demonst… ▽ More

    Submitted 30 June, 2022; originally announced June 2022.

    Comments: Accepted for publication in the Journal of Low Temperature Physics for LTD-19 special issue

  9. Development of a Josephson junction based single photon microwave detector for axion detection experiments

    Authors: D Alesini, D Babusci, C Barone, B Buonomo, M M Beretta, L Bianchini, G Castellano, F Chiarello, D Di Gioacchino, P Falferi, G Felici, G Filatrella, L G Foggetta, A Gallo, C Gatti, F Giazotto, G Lamanna, F Ligabue, N Ligato, C Ligi, G Maccarrone, B Margesin, F Mattioli, E Monticone, L Oberto , et al. (8 additional authors not shown)

    Abstract: Josephson junctions, in appropriate configurations, can be excellent candidates for detection of single photons in the microwave frequency band. Such possibility has been recently addressed in the framework of galactic axion detection. Here are reported recent developments in the modelling and simulation of dynamic behaviour of a Josephson junction single microwave photon detector. For a Josephson… ▽ More

    Submitted 2 July, 2021; originally announced July 2021.

    Comments: 7 pages, 9 figures

    Journal ref: J. Phys.: Conf. Ser. 1559 012020 (2020)

  10. arXiv:2107.00558  [pdf

    physics.ins-det astro-ph.IM

    Status of the SIMP Project: Toward the Single Microwave Photon Detection

    Authors: David Alesini, Danilo Babusci, Carlo Barone, Bruno Buonomo, Matteo Mario Beretta, Lorenzo Bianchini, Gabriella Castellano, Fabio Chiarello, Daniele Di Gioacchino, Paolo Falferi, Giulietto Felici, Giovanni Filatrella, Luca Gennaro Foggetta, Alessandro Gallo, Claudio Gatti, Francesco Giazotto, Gianluca Lamanna, Franco Ligabue, Nadia Ligato, Carlo Ligi, Giovanni Maccarrone, Benno Margesin, Francesco Mattioli, Eugenio Monticone, Luca Oberto , et al. (8 additional authors not shown)

    Abstract: The Italian institute for nuclear physics (INFN) has financed the SIMP project (2019-2021) in order to strengthen its skills and technologies in the field of meV detectors with the ultimate aim of develo** a single microwave photon detector. This goal will be pursued by improving the sensitivity and the dark count rate of two types of photodetectors: current biased Josephson Junction (JJ) for th… ▽ More

    Submitted 1 July, 2021; originally announced July 2021.

    Comments: 7 pages, 4 figures

    Journal ref: Journal of Low Temperature Physics (2020) 199:348-354

  11. arXiv:1912.06390  [pdf

    astro-ph.IM physics.ins-det

    The Demonstration Model of the ATHENA X-IFU Cryogenic AntiCoincidence Detector

    Authors: Matteo D'Andrea, Claudio Macculi, Guido Torrioli, Andrea Argan, Daniele Brienza, Simone Lotti, Gabriele Minervini, Luigi Piro, Michele Biasotti, Lorenzo Ferrari Barusso, Flavio Gatti, Manuela Rigano, Angela Volpe, Elia Stefano Battistelli

    Abstract: The Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU is designed to reduce the particle background of the instrument and to enable the mission science goals. It is a 4 pixel silicon microcalorimeter sensed by an Ir/Au TES network. We have developed the CryoAC Demonstration Model, a prototype aimed to probe the critical technologies of the detector, i.e. the suspended absorber with an ac… ▽ More

    Submitted 13 December, 2019; originally announced December 2019.

    Comments: Accepted for publication in the Journal of Low Temperature Physics for LTD-18 special issue

  12. arXiv:1807.08565  [pdf, other

    astro-ph.IM physics.ins-det

    The Cryogenic AntiCoincidence detector for ATHENA X-IFU: improvement of the test setup towards the Demonstration Model

    Authors: Matteo D'Andrea, Claudio Macculi, Andrea Argan, Simone Lotti, Gabriele Minervini, Luigi Piro, Michele Biasotti, Dario Corsini, Flavio Gatti, Guido Torrioli, Angela Volpe

    Abstract: The ATHENA X-IFU development program foresees to build and characterize an instrument Demonstration Model (DM), in order to probe the system critical technologies before the mission adoption. In this respect, we are now develo** the DM of the X-IFU Cryogenic Anticoincidence Detector (CryoAC), which will be delivered to the Focal Plane Assembly (FPA) development team for the integration with the… ▽ More

    Submitted 23 July, 2018; originally announced July 2018.

    Comments: Accepted for publication in the Journal of Low Temperature Physics for LTD-17 special issue

  13. arXiv:1807.08561  [pdf, other

    astro-ph.IM physics.ins-det

    The Cryogenic AntiCoincidence detector for ATHENA X-IFU: assessing the role of the athermal phonons collectors in the AC-S8 prototype

    Authors: Matteo D'Andrea, Claudio Macculi, Andrea Argan, Simone Lotti, Gabriele Minervini, Luigi Piro, Michele Biasotti, Dario Corsini, Flavio Gatti, Guido Torrioli

    Abstract: The ATHENA X-ray Observatory is the second large-class mission in the ESA Cosmic Vision 2015-2025 science programme. One of the two on-board instruments is the X-IFU, an imaging spectrometer based on a large array of TES microcalorimeters. To reduce the particle-induced background, the spectrometer works in combination with a Cryogenic Anticoincidence detector (CryoAC), placed less than 1 mm below… ▽ More

    Submitted 23 July, 2018; originally announced July 2018.

    Comments: Accepted for publication in the Journal of Low Temperature Physics for LTD-17 special issue

  14. arXiv:1807.02344  [pdf

    astro-ph.IM physics.ins-det

    The Cryogenic Anticoincidence Detector for ATHENA X-IFU: Preliminary test of AC-S9 towards the Demonstration Model

    Authors: Matteo D'Andrea, Claudio Macculi, Andrea Argan, Simone Lotti, Gabriele Minervini, Luigi Piro, Michele Biasotti, Valentina Ceriale, Giovanni Gallucci, Flavio Gatti, Guido Torrioli, Angela Volpe

    Abstract: Our team is develo** the Cryogenic Anticoincidence Detector (CryoAC) of the ATHENA X-ray Integral Field Unit (X-IFU). It is a 4-pixels TES-based detector, which will be placed less than 1 mm below the main TES array detector. We are now producing the CryoAC Demonstration Model (DM): a single pixel prototype able to probe the detector critical technologies, i.e. the operation at 50 mK thermal bat… ▽ More

    Submitted 11 July, 2018; v1 submitted 6 July, 2018; originally announced July 2018.

    Comments: Proceeding of the SPIE Astronomical Telescopes + Instrumentation 2018

  15. THz Discrimination of materials: demonstration of a bioinspired apparatus based on metasurfaces selective filters

    Authors: P. Carelli, F. Chiarello, G. Torrioli, M. G. Castellano

    Abstract: We present an apparatus for terahertz fingerprint discrimination of materials designed to be fast, simple, compact and economical in order to be suitable for preliminary on-field analysis. The system working principles, bioinspired by the human vision of colors, are based on the use of microfabricated metamaterials selective filters and of a very compact optics based on metallic ellipsoidal mirror… ▽ More

    Submitted 15 July, 2016; originally announced July 2016.

    Comments: 11 pages, 8 figures, to be submitted to Infrared Milli Terahz Waves

  16. arXiv:astro-ph/0206431  [pdf, ps, other

    astro-ph gr-qc physics.data-an

    Search for correlation between GRB's detected by BeppoSAX and gravitational wave detectors EXPLORER and NAUTILUS

    Authors: P. Astone, M. Bassan, P. Bonifazi, P. Carelli, G. Castellano, E. Coccia, C. Cosmelli, G. D'Agostini, S. D'Antonio, V. Fafone, G. Federici, F. Frontera, C. Guidorzi, A. Marini, Y. Minenkov, I. Modena, G. Modestino, A. Moleti, E. Montanari, G. V. Pallottino, G. Pizzella, L. Quintieri, A. Rocchi, F. Ronga, A. Rocchi , et al. (3 additional authors not shown)

    Abstract: Data obtained during five months of 2001 with the gravitational wave (GW) detectors EXPLORER and NAUTILUS were studied in correlation with the gamma ray burst data (GRB) obtained with the BeppoSAX satellite. During this period BeppoSAX was the only GRB satellite in operation, while EXPLORER and NAUTILUS were the only GW detectors in operation. No correlation between the GW data and the GRB bur… ▽ More

    Submitted 12 July, 2002; v1 submitted 25 June, 2002; originally announced June 2002.

    Comments: 14 pages, 7 figures. Latex file, compiled with cernik.cls (provided in the package)

    Journal ref: Phys.Rev. D66 (2002) 102002