-
Identification of spatial dynamic patterns of behavior using weighted Voronoi diagrams
Authors:
Martha Lorena Avendaño-Garrido,
Carlos Alberto Hernández-Linares,
Brenda Zarahí Medina-Pérez,
Varsovia Hernández,
Porfirio Toledo,
Alejandro León
Abstract:
This study proposes an innovative approach to analyze spatial patterns of behavior by integrating information in weighted Voronoi diagrams. The objective of the research is to analyze the temporal distribution of an experimental subject in different regions of a given space, with the aim of identifying significant areas of interest. The methodology employed involves dividing the experimental space…
▽ More
This study proposes an innovative approach to analyze spatial patterns of behavior by integrating information in weighted Voronoi diagrams. The objective of the research is to analyze the temporal distribution of an experimental subject in different regions of a given space, with the aim of identifying significant areas of interest. The methodology employed involves dividing the experimental space, determining representative points, and assigning weights based on the cumulative time the subject spends in each region. This process results in a set of generator points along with their respective weights, thus defining the Voronoi diagram. The study also presents a detailed and advanced perspective for understanding spatial behavioral patterns in experimental contexts.
△ Less
Submitted 16 June, 2024; v1 submitted 30 January, 2024;
originally announced January 2024.
-
Laser Calibration System for Time of Flight Scintillator Arrays
Authors:
A. Denniston,
E. P. Segarra,
A. Schmidt,
A. Beck,
S. May-Tal Beck,
R. Cruz-Torres,
F. Hauenstein,
A. Hrnjic,
T. Kutz,
A. Nambrath,
J. R. Pybus,
P. Toledo,
L. B. Weinstein,
M. Olivenboim,
E. Piasetzky,
I. Korover,
O. Hen
Abstract:
A laser calibration system was developed for monitoring and calibrating time of flight (TOF) scintillating detector arrays. The system includes setups for both small- and large-scale scintillator arrays. Following test-bench characterization, the laser system was recently commissioned in experimental Hall B at the Thomas Jefferson National Accelerator Facility for use on the new Backward Angle Neu…
▽ More
A laser calibration system was developed for monitoring and calibrating time of flight (TOF) scintillating detector arrays. The system includes setups for both small- and large-scale scintillator arrays. Following test-bench characterization, the laser system was recently commissioned in experimental Hall B at the Thomas Jefferson National Accelerator Facility for use on the new Backward Angle Neutron Detector (BAND) scintillator array. The system successfully provided time walk corrections, absolute time calibration, and TOF drift correction for the scintillators in BAND. This showcases the general applicability of the system for use on high-precision TOF detectors.
△ Less
Submitted 21 May, 2020; v1 submitted 21 April, 2020;
originally announced April 2020.
-
Radiopurity assessment of the energy readout for the NEXT double beta decay experiment
Authors:
S. Cebrián,
J. Pérez,
I. Bandac,
L. Labarga,
V. Álvarez,
C. D. R. Azevedo,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
A. Botas,
S. Cárcel,
J. V. Carrión,
C. A. N. Conde,
J. Díaz,
M. Diesburg,
J. Escada,
R. Esteve,
R. Felkai,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
A. Goldschmidt,
J. J. Gómez-Cadenas,
D. González-Díaz,
R. M. Gutiérrez
, et al. (45 additional authors not shown)
Abstract:
The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT) experiment intends to investigate the neutrinoless double beta decay of 136Xe, and therefore requires a severe suppression of potential backgrounds. An extensive material screening and selection process was undertaken to quantify the radioactivity of the materials used in the experiment. Separate energy and tracking readout planes…
▽ More
The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT) experiment intends to investigate the neutrinoless double beta decay of 136Xe, and therefore requires a severe suppression of potential backgrounds. An extensive material screening and selection process was undertaken to quantify the radioactivity of the materials used in the experiment. Separate energy and tracking readout planes using different sensors allow us to combine the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. The design of radiopure readout planes, in direct contact with the gas detector medium, was especially challenging since the required components typically have activities too large for experiments demanding ultra-low background conditions. After studying the tracking plane, here the radiopurity control of the energy plane is presented, mainly based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterráneo de Canfranc (Spain). All the available units of the selected model of photomultiplier have been screened together with most of the components for the bases, enclosures and windows. According to these results for the activity of the relevant radioisotopes, the selected components of the energy plane would give a contribution to the overall background level in the region of interest of at most 2.4 x 10-4 counts keV-1 kg-1 y-1, satisfying the sensitivity requirements of the NEXT experiment.
△ Less
Submitted 21 August, 2017; v1 submitted 19 June, 2017;
originally announced June 2017.