-
Natural-linewidth measurements of the 3C and 3D soft-x-ray transitions in Ni XIX
Authors:
Chintan Shah,
Steffen Kühn,
Sonja Bernitt,
René Steinbrügge,
Moto Togawa,
Lukas Berger,
Jens Buck,
Moritz Hoesch,
Jörn Seltmann,
Mikhail G. Kozlov,
Sergey G. Porsev,
Ming Feng Gu,
F. Scott Porter,
Thomas Pfeifer,
Maurice A. Leutenegger,
Charles Cheung,
Marianna S. Safronova,
José R. Crespo López-Urrutia
Abstract:
We used the monochromatic soft-x-ray beamline P04 at the synchrotron-radiation facility PETRA III to resonantly excite the strongest $2p-3d$ transitions in neon-like Ni XIX ions, $[2p^6]_{J=0} \rightarrow [(2p^5)_{1/2}\,3d_{3/2}]_{J=1}$ and $[2p^6]_{J=0} \rightarrow [(2p^5)_{3/2}\,3d_{5/2}]_{J=1}$, respectively dubbed 3C and 3D, achieving a resolving power of 15\,000 and signal-to-background ratio…
▽ More
We used the monochromatic soft-x-ray beamline P04 at the synchrotron-radiation facility PETRA III to resonantly excite the strongest $2p-3d$ transitions in neon-like Ni XIX ions, $[2p^6]_{J=0} \rightarrow [(2p^5)_{1/2}\,3d_{3/2}]_{J=1}$ and $[2p^6]_{J=0} \rightarrow [(2p^5)_{3/2}\,3d_{5/2}]_{J=1}$, respectively dubbed 3C and 3D, achieving a resolving power of 15\,000 and signal-to-background ratio of 30. We obtain their natural linewidths, with an accuracy of better than 10\%, as well as the oscillator-strength ratio $f(3C)/f(3D)$ = 2.51(11) from analysis of the resonant fluorescence spectra. These results agree with those of previous experiments, earlier predictions, and our own advanced calculations.
△ Less
Submitted 17 June, 2024; v1 submitted 22 April, 2024;
originally announced April 2024.
-
Testbeam results of irradiated SiGe BiCMOS monolithic silicon pixel detector without internal gain layer
Authors:
T. Moretti,
M. Milanesio,
R. Cardella,
T. Kugathasan,
A. Picardi,
I. Semendyaev,
M. Elviretti,
H. Rücker,
K. Nakamura,
Y. Takubo,
M. Togawa,
F. Cadoux,
R. Cardarelli,
L. Cecconi,
S. Débieux,
Y. Favre,
C. A. Fenoglio,
D. Ferrere,
S. Gonzalez-Sevilla,
L. Iodice,
R. Kotitsa,
C. Magliocca,
M. Nessi,
A. Pizarro-Medina,
J. Sabater Iglesias
, et al. (5 additional authors not shown)
Abstract:
Samples of the monolithic silicon pixel ASIC prototype produced in 2022 within the framework of the Horizon 2020 MONOLITH ERC Advanced project were irradiated with 70 MeV protons up to a fluence of 1 x 1016 neq/cm2, and then tested using a beam of 120 GeV/c pions. The ASIC contains a matrix of 100 μm pitch hexagonal pixels, readout out by low noise and very fast frontend electronics produced in a…
▽ More
Samples of the monolithic silicon pixel ASIC prototype produced in 2022 within the framework of the Horizon 2020 MONOLITH ERC Advanced project were irradiated with 70 MeV protons up to a fluence of 1 x 1016 neq/cm2, and then tested using a beam of 120 GeV/c pions. The ASIC contains a matrix of 100 μm pitch hexagonal pixels, readout out by low noise and very fast frontend electronics produced in a 130 nm SiGe BiCMOS technology process. The dependence on the proton fluence of the efficiency and the time resolution of this prototype was measured with the frontend electronics operated at a power density between 0.13 and 0.9 W/cm2. The testbeam data show that the detection efficiency of 99.96% measured at sensor bias voltage of 200 V before irradiation becomes 96.2% after a fluence of 1 x 1016 neq/cm2. An increase of the sensor bias voltage to 300 V provides an efficiency to 99.7% at that proton fluence. The timing resolution of 20 ps measured before irradiation rises for a proton fluence of 1 x 1016 neq/cm2 to 53 and 45 ps at HV = 200 and 300 V, respectively.
△ Less
Submitted 21 June, 2024; v1 submitted 19 April, 2024;
originally announced April 2024.
-
High-Precision Transition Energy Measurements of Neonlike Fe XVII Ions
Authors:
Chintan Shah,
Moto Togawa,
Marc Botz,
Jonas Danisch,
Joschka J. Goes,
Sonja Bernitt,
Marleen Maxton,
Kai Köbnick,
Jen Buck,
Jörn Seltmann,
Moritz Hoesch,
Ming Feng Gu,
F. Scott Porter,
Thomas Pfeifer,
Maurice A. Leutenegger,
Charles Cheung,
Marianna S. Safronova,
José R. Crespo López-Urrutia
Abstract:
We improve by a factor of 4-20 the energy accuracy of the strongest soft X-ray transitions of Fe XVII ions by resonantly exciting them in an electron beam ion trap with a monochromatic beam at the P04 beamline of the PETRA III synchrotron facility. By simultaneously tracking instantaneous photon-energy fluctuations with a high-resolution photoelectron spectrometer, we minimize systematic uncertain…
▽ More
We improve by a factor of 4-20 the energy accuracy of the strongest soft X-ray transitions of Fe XVII ions by resonantly exciting them in an electron beam ion trap with a monochromatic beam at the P04 beamline of the PETRA III synchrotron facility. By simultaneously tracking instantaneous photon-energy fluctuations with a high-resolution photoelectron spectrometer, we minimize systematic uncertainties down to 10-15 meV, or velocity-equivalent +/- ~5 km/s in their rest energies, substantially improving our knowledge of this key astrophysical ion. Our large-scale configuration-interaction computations include more than four million relativistic configurations and agree with the experiment at a level without precedent for a ten-electron system. Thereby, theoretical uncertainties for interelectronic correlations become far smaller than those of quantum electrodynamics (QED) corrections. The present QED benchmark strengthens our trust in future calculations of many other complex atomic ions of interest to astrophysics, plasma physics, and for the development of optical clocks with highly charged ions.
△ Less
Submitted 2 April, 2024; v1 submitted 16 January, 2024;
originally announced January 2024.
-
Radiation Tolerance of SiGe BiCMOS Monolithic Silicon Pixel Detectors without Internal Gain Layer
Authors:
M. Milanesio,
L. Paolozzi,
T. Moretti,
R. Cardella,
T. Kugathasan,
F. Martinelli,
A. Picardi,
I. Semendyaev,
S. Zambito,
K. Nakamura,
Y. Tabuko,
M. Togawa,
M. Elviretti,
H. Rücker,
F. Cadoux,
R. Cardarelli,
S. Débieux,
Y. Favre,
C. A. Fenoglio,
D. Ferrere,
S. Gonzalez-Sevilla,
L. Iodice,
R. Kotitsa,
C. Magliocca,
M. Nessi
, et al. (5 additional authors not shown)
Abstract:
A monolithic silicon pixel prototype produced for the MONOLITH ERC Advanced project was irradiated with 70 MeV protons up to a fluence of 1 x 10^16 1 MeV n_eq/cm^2. The ASIC contains a matrix of hexagonal pixels with 100 μm pitch, readout by low-noise and very fast SiGe HBT frontend electronics. Wafers with 50 μm thick epilayer with a resistivity of 350 Ωcm were used to produce a fully depleted se…
▽ More
A monolithic silicon pixel prototype produced for the MONOLITH ERC Advanced project was irradiated with 70 MeV protons up to a fluence of 1 x 10^16 1 MeV n_eq/cm^2. The ASIC contains a matrix of hexagonal pixels with 100 μm pitch, readout by low-noise and very fast SiGe HBT frontend electronics. Wafers with 50 μm thick epilayer with a resistivity of 350 Ωcm were used to produce a fully depleted sensor. Laboratory tests conducted with a 90Sr source show that the detector works satisfactorily after irradiation. The signal-to-noise ratio is not seen to change up to fluence of 6 x 10^14 n_eq /cm^2 . The signal time jitter was estimated as the ratio between the voltage noise and the signal slope at threshold. At -35 {^\circ}C, sensor bias voltage of 200 V and frontend power consumption of 0.9 W/cm^2, the time jitter of the most-probable signal amplitude was estimated to be 21 ps for proton fluence up to 6 x 10 n_eq/cm^2 and 57 ps at 1 x 10^16 n_eq/cm^2 . Increasing the sensor bias to 250 V and the analog voltage of the preamplifier from 1.8 to 2.0 V provides a time jitter of 40 ps at 1 x 10^16 n_eq/cm^2.
△ Less
Submitted 30 October, 2023;
originally announced October 2023.
-
New Measurement Resolves Key Astrophysical Fe XVII Oscillator Strength Problem
Authors:
Steffen Kühn,
Charles Cheung,
Natalia S. Oreshkina,
René Steinbrügge,
Moto Togawa,
Sonja Bernitt,
Lukas Berger,
Jens Buck,
Moritz Hoesch,
Jörn Seltmann,
Florian Trinter,
Christoph H. Keitel,
Mikhail G. Kozlov,
Sergey G. Porsev,
Ming Feng Gu,
F. Scott Porter,
Thomas Pfeifer,
Maurice A. Leutenegger,
Zoltán Harman,
Marianna S. Safronova,
José R. Crespo López-Urrutia,
Chintan Shah
Abstract:
One of the most enduring and intensively studied problems of X-ray astronomy is the disagreement of state-of-the art theory and observations for the intensity ratio of two Fe XVII transitions of crucial value for plasma diagnostics, dubbed 3C and 3D. We unravel this conundrum at the PETRA III synchrotron facility by increasing the resolving power two and a half times and the signal-to-noise ratio…
▽ More
One of the most enduring and intensively studied problems of X-ray astronomy is the disagreement of state-of-the art theory and observations for the intensity ratio of two Fe XVII transitions of crucial value for plasma diagnostics, dubbed 3C and 3D. We unravel this conundrum at the PETRA III synchrotron facility by increasing the resolving power two and a half times and the signal-to-noise ratio thousand-fold compared to our previous work. The Lorentzian wings had hitherto been indistinguishable from the background and were thus not modeled, resulting in a biased line-strength estimation. The present experimental oscillator-strength ratio $R_\mathrm{exp}=f_{\mathrm{3C}}/f_{\mathrm{3D}}=3.51(2)_{\mathrm{stat}}(7)_{\mathrm{sys}}$ agrees with our state-of-the-art calculation of $R_\mathrm{th}=3.55(2)$, as well as with some previous theoretical predictions. To further rule out any uncertainties associated with the measured ratio, we also determined the individual natural linewidths and oscillator strengths of 3C and 3D transitions, which also agree well with the theory. This finally resolves the decades-old mystery of Fe XVII oscillator strengths.
△ Less
Submitted 6 December, 2022; v1 submitted 22 January, 2022;
originally announced January 2022.
-
Observation of strong two-electron--one-photon transitions in few-electron ion
Authors:
Moto Togawa,
Steffen Kühn,
Chintan Shah,
Pedro Amaro,
René Steinbrügge,
Jakob Stierhof,
Natalie Hell,
Michael Rosner,
Keisuke Fujii,
Matthias Bissinger,
Ralf Ballhausen,
Moritz Hoesch,
Jörn Seltmann,
SungNam Park,
Filipe Grilo,
F. Scott Porter,
José Paulo Santos,
Moses Chung,
Thomas Stöhlker,
Jörn Wilms,
Thomas Pfeifer,
Gregory V. Brown,
Maurice A. Leutenegger,
Sven Bernitt,
José R. Crespo López-Urrutia
Abstract:
We resonantly excite the $K$ series of O$^{5+}$ and O$^{6+}$ up to principal quantum number $n=11$ with monochromatic x rays, producing $K$-shell holes, and observe their relaxation by soft-x-ray emission. Some photoabsorption resonances of O$^{5+}$ reveal strong two-electron--one-photon (TEOP) transitions. We find that for the $[(1s\,2s)_1\,5p_{3/2}]_{3/2;1/2}$ states, TEOP relaxation is by far s…
▽ More
We resonantly excite the $K$ series of O$^{5+}$ and O$^{6+}$ up to principal quantum number $n=11$ with monochromatic x rays, producing $K$-shell holes, and observe their relaxation by soft-x-ray emission. Some photoabsorption resonances of O$^{5+}$ reveal strong two-electron--one-photon (TEOP) transitions. We find that for the $[(1s\,2s)_1\,5p_{3/2}]_{3/2;1/2}$ states, TEOP relaxation is by far stronger than the radiative decay and competes with the usually much faster Auger decay path. This enhanced TEOP decay arises from a strong correlation with the near-degenerate upper states $[(1s\,2p_{3/2})_1\,4s]_{3/2;1/2}$ of a Li-like satellite blend of the He-like $Kα$ transition. Even in three-electron systems, TEOP transitions can play a dominant role, and the present results should guide further research on the ubiquitous and abundant many-electron ions where electronic energy degeneracies are far more common and configuration mixing is stronger.
△ Less
Submitted 25 November, 2020; v1 submitted 12 March, 2020;
originally announced March 2020.
-
High Resolution Photoexcitation Measurements Exacerbate the Long-Standing Fe XVII Oscillator Strength Problem
Authors:
Steffen Kühn,
Chintan Shah,
José R. Crespo López-Urrutia,
Keisuke Fujii,
René Steinbrügge,
Jakob Stierhof,
Moto Togawa,
Zoltán Harman,
Natalia S. Oreshkina,
Charles Cheung,
Mikhail G. Kozlov,
Sergey G. Porsev,
Marianna S. Safronova,
Julian C. Berengut,
Michael Rosner,
Matthias Bissinger,
Ralf Ballhausen,
Natalie Hell,
SungNam Park,
Moses Chung,
Moritz Hoesch,
Jörn Seltmann,
Andrey S. Surzhykov,
Vladimir A. Yerokhin,
Jörn Wilms
, et al. (7 additional authors not shown)
Abstract:
For more than 40 years, most astrophysical observations and laboratory studies of two key soft x-ray diagnostic $2p-3d$ transitions, $3C$ and $3D$, in Fe XVII ions found oscillator strength ratios $f(3C)/f(3D)$ disagreeing with theory, but uncertainties had precluded definitive statements on this much studied conundrum. Here, we resonantly excite these lines using synchrotron radiation at PETRA II…
▽ More
For more than 40 years, most astrophysical observations and laboratory studies of two key soft x-ray diagnostic $2p-3d$ transitions, $3C$ and $3D$, in Fe XVII ions found oscillator strength ratios $f(3C)/f(3D)$ disagreeing with theory, but uncertainties had precluded definitive statements on this much studied conundrum. Here, we resonantly excite these lines using synchrotron radiation at PETRA III, and reach, at a millionfold lower photon intensities, a 10 times higher spectral resolution, and 3 times smaller uncertainty than earlier work. Our final result of $f(3C)/f(3D) = 3.09(8)(6)$ supports many of the earlier clean astrophysical and laboratory observations, while departing by five sigmas from our own newest large-scale ab initio calculations, and excluding all proposed explanations, including those invoking nonlinear effects and population transfers.
△ Less
Submitted 3 June, 2020; v1 submitted 21 November, 2019;
originally announced November 2019.
-
Long-lived neutral-kaon flux measurement for the KOTO experiment
Authors:
T. Masuda,
J. K. Ahn,
S. Banno,
M. Campbell,
J. Comfort,
Y. T. Duh,
T. Hineno,
Y. B. Hsiung,
T. Inagaki,
E. Iwai,
N. Kawasaki,
E. J. Kim,
Y. J. Kim,
J. W. Ko,
T. K. Komatsubara,
A. S. Kurilin,
G. H. Lee,
J. W. Lee,
S. K. Lee,
G. Y. Lim,
J. Ma,
D. MacFarland,
Y. Maeda,
T. Matsumura,
R. Murayama
, et al. (32 additional authors not shown)
Abstract:
The KOTO ($K^0$ at Tokai) experiment aims to observe the CP-violating rare decay $K_L \rightarrow π^0 ν\barν$ by using a long-lived neutral-kaon beam produced by the 30 GeV proton beam at the Japan Proton Accelerator Research Complex. The $K_L$ flux is an essential parameter for the measurement of the branching fraction. Three $K_L$ neutral decay modes, $K_L \rightarrow 3π^0$,…
▽ More
The KOTO ($K^0$ at Tokai) experiment aims to observe the CP-violating rare decay $K_L \rightarrow π^0 ν\barν$ by using a long-lived neutral-kaon beam produced by the 30 GeV proton beam at the Japan Proton Accelerator Research Complex. The $K_L$ flux is an essential parameter for the measurement of the branching fraction. Three $K_L$ neutral decay modes, $K_L \rightarrow 3π^0$, $K_L \rightarrow 2π^0$, and $K_L \rightarrow 2γ$ were used to measure the $K_L$ flux in the beam line in the 2013 KOTO engineering run. A Monte Carlo simulation was used to estimate the detector acceptance for these decays. Agreement was found between the simulation model and the experimental data, and the remaining systematic uncertainty was estimated at the 1.4\% level. The $K_L$ flux was measured as $(4.183 \pm 0.017_{\mathrm{stat.}} \pm 0.059_{\mathrm{sys.}}) \times 10^7$ $K_L$ per $2\times 10^{14}$ protons on a 66-mm-long Au target.
△ Less
Submitted 7 January, 2016; v1 submitted 11 September, 2015;
originally announced September 2015.
-
Photon-Veto Counters at the Outer Edge of the Endcap Calorimeter for the KOTO Experiment
Authors:
T. Matsumura,
T. Shinkawa,
H. Yokota,
E. Iwai,
T. K. Komatsubara,
J. W. Lee,
G. Y. Lim,
J. Ma,
T. Masuda,
H. Nanjo,
T. Nomura,
Y. Odani,
Y. D. Ri,
K. Shiomi,
Y. Sugiyama,
S. Suzuki,
M. Togawa,
Y. Wah,
H. Watanabe,
T. Yamanaka
Abstract:
The Outer-Edge Veto (OEV) counter subsystem for extra-photon detection from the backgrounds for the? $K^0_L\rightarrowπ^0ν\barν$ decay is located at the outer edge of the endcap CsI calorimeter of the KOTO experiment at J-PARC. The subsystem is composed of 44 counters with different cross-sectional shapes. All counters are made of lead and scintillator plates and read out through wavelength-shifti…
▽ More
The Outer-Edge Veto (OEV) counter subsystem for extra-photon detection from the backgrounds for the? $K^0_L\rightarrowπ^0ν\barν$ decay is located at the outer edge of the endcap CsI calorimeter of the KOTO experiment at J-PARC. The subsystem is composed of 44 counters with different cross-sectional shapes. All counters are made of lead and scintillator plates and read out through wavelength-shifting fibers. In this paper, we discuss the design and performances of the OEV counters under heavy load ($\sim8$ tons/m$^2$) in vacuum. For 1-MeV energy deposit, the average light yield and time resolution are 20.9 photo-electrons and 1.5 ns, respectively. Although no pronounced peak by minimum-ionizing particles is observed in the energy distributions, an energy calibration method with cosmic rays works well in monitoring the gain stability with an accuracy of a few percent.
△ Less
Submitted 18 May, 2015; v1 submitted 29 September, 2014;
originally announced September 2014.
-
The Data Acquisition System for the KOTO Experiment
Authors:
Yasuyuki Sugiyama,
Jia Xu,
Monica Tecchio,
Nikola Whallon,
Duncan McFarland,
Jiasen Ma,
Manabu Togawa,
Yasuhisa Tajima,
Mircea Bogdan,
Jon Ameel,
Myron Campbell,
Yau Wai Wah,
Joseph Comfort,
Taku Yamanaka
Abstract:
We developed and built a new system of readout and trigger electronics, based on the waveform digitization and pipeline readout, for the KOTO experiment at J-PARC, Japan. KOTO aims at observing the rare kaon decay $K_{L}\rightarrowπ^{0}ν\barν$. A total of 4000 readout channels from various detector subsystems are digitized by 14-bit 125-MHz ADC modules equipped with a 10-pole Bessel filter in orde…
▽ More
We developed and built a new system of readout and trigger electronics, based on the waveform digitization and pipeline readout, for the KOTO experiment at J-PARC, Japan. KOTO aims at observing the rare kaon decay $K_{L}\rightarrowπ^{0}ν\barν$. A total of 4000 readout channels from various detector subsystems are digitized by 14-bit 125-MHz ADC modules equipped with a 10-pole Bessel filter in order to reduce the pile-up effects. The trigger decision is made every 8-ns using the digitized waveform information. To avoid dead time, the ADC and trigger modules have pipelines in their FPGA chips to store data while waiting for the trigger decision. The KOTO experiment performed the first physics run in May 2013. The data acquisition system worked stably during the run.
△ Less
Submitted 16 June, 2014;
originally announced June 2014.