Double-hit separation and dE/dx resolution of a time projection chamber with GEM readout
Authors:
Yumi Aoki,
David Attié,
Ties Behnke,
Alain Bellerive,
Oleg Bezshyyko,
Deb Bhattacharya Sankar,
Purba Bhattacharya,
Sudeb Bhattacharya,
Yue Chang,
Paul Colas,
Gilles De Lentdecker,
Klaus Dehmelt,
Klaus Desch,
Ralf Diener,
Madhu Dixit,
Ulrich Einhaus,
Oleksiy Fedorchuk,
Ivor Fleck,
Keisuke Fujii,
Takahiro Fusayasu,
Serguei Ganjour,
Philippe Gros,
Peter Hayman,
Katsumasa Ikematsu,
Leif Jönsson
, et al. (46 additional authors not shown)
Abstract:
A time projection chamber (TPC) with micropattern gaseous detector (MPGD) readout is investigated as main tracking device of the International Large Detector (ILD) concept at the planned International Linear Collider (ILC). A prototype TPC equipped with a triple gas electron multiplier (GEM) readout has been built and operated in an electron test beam. The TPC was placed in a 1 T solenoidal field…
▽ More
A time projection chamber (TPC) with micropattern gaseous detector (MPGD) readout is investigated as main tracking device of the International Large Detector (ILD) concept at the planned International Linear Collider (ILC). A prototype TPC equipped with a triple gas electron multiplier (GEM) readout has been built and operated in an electron test beam. The TPC was placed in a 1 T solenoidal field at the DESY II Test Beam Facility, which provides an electron beam up to 6 GeV/c. The performance of the readout modules, in particular the spatial point resolution, is determined and compared to earlier tests. New studies are presented with first results on the separation of close-by tracks and the capability of the system to measure the specific energy loss dE/dx. This is complemented by a simulation study on the optimization of the readout granularity to improve particle identification by dE/dx.
△ Less
Submitted 25 November, 2022; v1 submitted 24 May, 2022;
originally announced May 2022.
-
The International Linear Collider: Report to Snowmass 2021
Authors:
Alexander Aryshev,
Ties Behnke,
Mikael Berggren,
James Brau,
Nathaniel Craig,
Ayres Freitas,
Frank Gaede,
Spencer Gessner,
Stefania Gori,
Christophe Grojean,
Sven Heinemeyer,
Daniel Jeans,
Katja Kruger,
Benno List,
Jenny List,
Zhen Liu,
Shinichiro Michizono,
David W. Miller,
Ian Moult,
Hitoshi Murayama,
Tatsuya Nakada,
Emilio Nanni,
Mihoko Nojiri,
Hasan Padamsee,
Maxim Perelstein
, et al. (487 additional authors not shown)
Abstract:
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This docu…
▽ More
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This document brings the story of the ILC up to date, emphasizing its strong physics motivation, its readiness for construction, and the opportunity it presents to the US and the global particle physics community.
△ Less
Submitted 16 January, 2023; v1 submitted 14 March, 2022;
originally announced March 2022.
-
MPGDs for TPCs at future lepton colliders
Authors:
Alain Bellerive,
Jochen Kaminski,
Peter M. Lewis,
Paul Colas,
Ralf Diener,
Peter Kluit,
Ronald Dean Settles,
Jan Timmermans,
Maxim Titov,
Andreas Loschcke Centeno,
Christian Wessel,
Oskar Hartbrich,
Sven Vahsen,
Carlos Marinas,
Huiron Qi,
Zhiyong Zhang
Abstract:
This submission will focus on advancements and advantages of Micro Pattern Gas Detector (MPGD) technologies and their applications to the construction of a dedicated Time Projection Chamber (TPC) that can serve as an excellent main tracker for any multipurpose detector that can be foreseen to operate at a future lepton collider. The first portion of the report will be the executive summary. It wil…
▽ More
This submission will focus on advancements and advantages of Micro Pattern Gas Detector (MPGD) technologies and their applications to the construction of a dedicated Time Projection Chamber (TPC) that can serve as an excellent main tracker for any multipurpose detector that can be foreseen to operate at a future lepton collider. The first portion of the report will be the executive summary. It will be followed by sections detailing the applications of MPGDs specifically to the construction of the LCTPC for the ILD at ILC, for a possible upgrade of the Belle II detector at SuperKEKB and for the design of a TPC for a detector at CEPC. MPGD technologies offer synergies with other detector R&D and several application domains; a few examples will be provided in the context of the ongoing Snowmass long range planning exercise in the USA. Links to industrial partnership and work with institutions in the USA will be highlighted when appropriate.
△ Less
Submitted 15 March, 2022; v1 submitted 11 March, 2022;
originally announced March 2022.
-
Performance of the GridPix detector quad
Authors:
Cornelis Ligtenberg,
Yevgen Bilevych,
Klaus Desch,
Harry van der Graaf,
Markus Gruber,
Fred Hartjes,
Kevin Heijhoff,
Jochen Kaminski,
Peter M. Kluit,
Naomi van der Kolk,
Gerhard Raven,
Tobias Schiffer,
Jan Timmermans
Abstract:
A gaseous pixel readout module with four GridPix chips, called the quad, has been developed as a building block for a large time projection chamber readout plane. The quad module has dimensions 39.6 mm $\times$ 28.38 mm and an active surface coverage of 68.9%. The GridPix chip consists of a Timepix3 chip with integrated amplification grid and have a high efficiency to detect single ionisation elec…
▽ More
A gaseous pixel readout module with four GridPix chips, called the quad, has been developed as a building block for a large time projection chamber readout plane. The quad module has dimensions 39.6 mm $\times$ 28.38 mm and an active surface coverage of 68.9%. The GridPix chip consists of a Timepix3 chip with integrated amplification grid and have a high efficiency to detect single ionisation electrons, which enable to make a precise track position measurement. A quad module was installed in a small time projection chamber and measurements of 2.5 GeV electrons were performed at the ELSA accelerator in Bonn, where a silicon telescope was used to provide a reference track. The error on the track position measurement, both in the pixel plane and drift direction, is dominated by diffusion. The quad was designed to have minimum electrical field inhomogeneities and distortions, achieving systematics of better than 13 $μ$m in the pixel plane. The resolution of the setup is 41 $μ$m, where the total systematic error of the quad detector is 24 $μ$m.
△ Less
Submitted 6 January, 2020;
originally announced January 2020.
-
Performance of a GridPix TPC readout based on the Timepix3 chip
Authors:
C. Ligtenberg,
K. Heijhoff,
Y. Bilevych,
K. Desch,
H. van der Graaf,
M. Gruber,
F. Hartjes,
J. Kaminski,
N. van der Kolk,
P. M. Kluit,
G. Raven,
L. Scharenberg,
T. Schiffer,
S. Schmidt,
J. Timmermans
Abstract:
With the ultimate goal of develo** a pixel-based readout for a TPC at the ILC, a GridPix readout system consisting of one Timepix3 chip with an integrated amplification grid was embedded in a prototype detector. The performance was studied in a testbeam with 2.5 GeV electrons at the ELSA accelerator in Bonn. The error on the track position measurement both in the drift direction and in the reado…
▽ More
With the ultimate goal of develo** a pixel-based readout for a TPC at the ILC, a GridPix readout system consisting of one Timepix3 chip with an integrated amplification grid was embedded in a prototype detector. The performance was studied in a testbeam with 2.5 GeV electrons at the ELSA accelerator in Bonn. The error on the track position measurement both in the drift direction and in the readout plane is dominated by diffusion. Systematic uncertainties are limited to below 10 $μ$m. The GridPix can detect single ionization electrons with high efficiency, which allows for energy loss measurements and particle identification. From a truncated sum, an energy loss (dE/dx) resolution of 4.1% is found for an effective track length of 1 m. Using the same type of chips, a Quad module was developed that can be tiled to cover a TPC readout plane at the ILC. Simulation studies show that a pixel readout can improve the momentum resolution of a TPC at the ILC by about 20%.
△ Less
Submitted 5 February, 2019;
originally announced February 2019.
-
Performance of a GridPix detector based on the Timepix3 chip
Authors:
C. Ligtenberg,
K. Heijhoff,
Y. Bilevych,
K. Desch,
H. van der Graaf,
F. Hartjes,
J. Kaminski,
P. M. Kluit,
G. Raven,
T. Schiffer,
J. Timmermans
Abstract:
A GridPix readout for a TPC based on the Timepix3 chip is developed for future applications at a linear collider. The GridPix detector consists of a gaseous drift volume read out by a single Timepix3 chip with an integrated amplification grid. Its performance is studied in a test beam with 2.5 GeV electrons. The GridPix detector detects single ionization electrons with high efficiency. The Timepix…
▽ More
A GridPix readout for a TPC based on the Timepix3 chip is developed for future applications at a linear collider. The GridPix detector consists of a gaseous drift volume read out by a single Timepix3 chip with an integrated amplification grid. Its performance is studied in a test beam with 2.5 GeV electrons. The GridPix detector detects single ionization electrons with high efficiency. The Timepix3 chip allowed for high sample rates and time walk corrections. Diffusion is found to be the dominating error on the track position measurement both in the pixel plane and in the drift direction, and systematic distortions in the pixel plane are below 10 $μ$m. Using a truncated sum, an energy loss (dE/dx) resolution of 4.1% is found for an effective track length of 1 m.
△ Less
Submitted 22 August, 2018; v1 submitted 14 August, 2018;
originally announced August 2018.
-
A Time Projection Chamber with GEM-Based Readout
Authors:
The LCTPC Collaboration,
David Attié,
Ties Behnke,
Alain Bellerive,
Oleg Bezshyyko,
Deb Sankar Bhattacharya,
Purba Bhattacharya,
Sudeb Bhattacharya,
Stefano Caiazza,
Paul Colas,
Gilles De Lentdecker,
Klaus Dehmelt,
Klaus Desch,
Ralf Diener,
Madhu Dixit,
Ivor Fleck,
Keisuke Fujii,
Takahiro Fusayasu,
Serguei Ganjour,
Yuanning Gao,
Philippe Gros,
Peter Hayman,
Vincent Hedberg,
Katsumasa Ikematsu,
Leif Jönsson
, et al. (45 additional authors not shown)
Abstract:
For the International Large Detector concept at the planned International Linear Collider, the use of time projection chambers (TPC) with micro-pattern gas detector readout as the main tracking detector is investigated. In this paper, results from a prototype TPC, placed in a 1 T solenoidal field and read out with three independent GEM-based readout modules, are reported. The TPC was exposed to a…
▽ More
For the International Large Detector concept at the planned International Linear Collider, the use of time projection chambers (TPC) with micro-pattern gas detector readout as the main tracking detector is investigated. In this paper, results from a prototype TPC, placed in a 1 T solenoidal field and read out with three independent GEM-based readout modules, are reported. The TPC was exposed to a 6 GeV electron beam at the DESY II synchrotron. The efficiency for reconstructing hits, the measurement of the drift velocity, the space point resolution and the control of field inhomogeneities are presented.
△ Less
Submitted 4 April, 2016;
originally announced April 2016.
-
Beam Test with a GridGEM TPC Prototype Module
Authors:
Ralf Diener,
Ties Behnke,
Stefano Caiazza,
Isa Heinze,
Volker Prahl,
Christoph Rosemann,
Oliver Schäfer,
Jan Timmermans,
Robert Volkenborn,
Klaus Zenker
Abstract:
The International Large Detector (ILD) --a detector concept for the International Linear Collider (ILC)-- foresees a Time Projection Chamber (TPC) as its main tracking detector. Currently, the R&D efforts for such a TPC focus on studies using a large prototype that can accommodate up to seven read-out modules which are comparable to the ones that would be used in the final ILD TPC. The DESY TPC gr…
▽ More
The International Large Detector (ILD) --a detector concept for the International Linear Collider (ILC)-- foresees a Time Projection Chamber (TPC) as its main tracking detector. Currently, the R&D efforts for such a TPC focus on studies using a large prototype that can accommodate up to seven read-out modules which are comparable to the ones that would be used in the final ILD TPC. The DESY TPC group has developed such a module using GEMs for the gas amplification, which are mounted on thin ceramic frames. The module design and first results of a test beam campaign are presented.
△ Less
Submitted 29 February, 2012;
originally announced February 2012.
-
Infrastructure for Detector Research and Development towards the International Linear Collider
Authors:
J. Aguilar,
P. Ambalathankandy,
T. Fiutowski,
M. Idzik,
Sz. Kulis,
D. Przyborowski,
K. Swientek,
A. Bamberger,
M. Köhli,
M. Lupberger,
U. Renz,
M. Schumacher,
Andreas Zwerger,
A. Calderone,
D. G. Cussans,
H. F. Heath,
S. Mandry,
R. F. Page,
J. J. Velthuis,
D. Attié,
D. Calvet,
P. Colas,
X. Coppolani,
Y. Degerli,
E. Delagnes
, et al. (252 additional authors not shown)
Abstract:
The EUDET-project was launched to create an infrastructure for develo** and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infras…
▽ More
The EUDET-project was launched to create an infrastructure for develo** and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infrastructures for tracking detectors as well as for calorimetry.
△ Less
Submitted 23 January, 2012;
originally announced January 2012.
-
A Layer Correlation technique for pion energy calibration at the 2004 ATLAS Combined Beam Test
Authors:
E. Abat,
J. M. Abdallah,
T. N. Addy,
P. Adragna,
M. Aharrouche,
A. Ahmad,
T. P. A. Akesson,
M. Aleksa,
C. Alexa,
K. Anderson,
A. Andreazza,
F. Anghinolfi,
A. Antonaki,
G. Arabidze,
E. Arik,
T. Atkinson,
J. Baines,
O. K. Baker,
D. Banfi,
S. Baron,
A. J. Barr,
R. Beccherle,
H. P. Beck,
B. Belhorma,
P. J. Bell
, et al. (460 additional authors not shown)
Abstract:
A new method for calibrating the hadron response of a segmented calorimeter is developed and successfully applied to beam test data. It is based on a principal component analysis of energy deposits in the calorimeter layers, exploiting longitudinal shower development information to improve the measured energy resolution. Corrections for invisible hadronic energy and energy lost in dead material in…
▽ More
A new method for calibrating the hadron response of a segmented calorimeter is developed and successfully applied to beam test data. It is based on a principal component analysis of energy deposits in the calorimeter layers, exploiting longitudinal shower development information to improve the measured energy resolution. Corrections for invisible hadronic energy and energy lost in dead material in front of and between the calorimeters of the ATLAS experiment were calculated with simulated Geant4 Monte Carlo events and used to reconstruct the energy of pions im**ing on the calorimeters during the 2004 Barrel Combined Beam Test at the CERN H8 area. For pion beams with energies between 20 GeV and 180 GeV, the particle energy is reconstructed within 3% and the energy resolution is improved by between 11% and 25% compared to the resolution at the electromagnetic scale.
△ Less
Submitted 12 May, 2011; v1 submitted 20 December, 2010;
originally announced December 2010.
-
An integrated Micromegas UV-photon detector
Authors:
Joost Melai,
Alexey Lyashenko,
Amos Breskin,
Harry van der Graaf,
Jan Timmermans,
Jan Visschers,
Cora Salm,
Jurriaan Schmitz
Abstract:
Preliminary results of a photon detector combining a Micromegas like multiplier coated with a UV-sensitive CsI photocathode are described. The multiplier is made in a CMOS compatible InGrid technology, which allows to post-process it directly on the surface of an imaging IC. This method is aimed at building light-sensitive imaging detectors where all elements are monolithically integrated. We show…
▽ More
Preliminary results of a photon detector combining a Micromegas like multiplier coated with a UV-sensitive CsI photocathode are described. The multiplier is made in a CMOS compatible InGrid technology, which allows to post-process it directly on the surface of an imaging IC. This method is aimed at building light-sensitive imaging detectors where all elements are monolithically integrated. We show that the CsI photocathode deposited in the InGrid mesh does not alter the device performance. Maximum gains of ~6000 were reached in a single-grid element operated in Ar/CH4, with a 2% Ion Back Flow fraction returning to the photocathode.
△ Less
Submitted 9 March, 2010;
originally announced March 2010.
-
Data Preservation at LEP
Authors:
André G. Holzner,
Ryszard Gokieli,
Peter Igo-Kemenes,
Marcello Maggi,
Luca Malgeri,
Salvatore Mele,
Luc Pape,
David Plane,
Matthias Schröder,
Ulrich Schwickerath,
Roberto Tenchini,
Jan Timmermans
Abstract:
The four LEP experiments ALEPH, DELPHI, L3 and OPAL successfully recorded e+e- collision data during the years 1989 to 2000. As part of the ordinary evolution in High Energy Physics, these experiments can not be repeated and their data is therefore unique. This article briefly reviews the data preservation efforts undertaken by the four experiments beyond the end of data taking. The current stat…
▽ More
The four LEP experiments ALEPH, DELPHI, L3 and OPAL successfully recorded e+e- collision data during the years 1989 to 2000. As part of the ordinary evolution in High Energy Physics, these experiments can not be repeated and their data is therefore unique. This article briefly reviews the data preservation efforts undertaken by the four experiments beyond the end of data taking. The current status of the preserved data and associated tools is summarised.
△ Less
Submitted 9 December, 2009;
originally announced December 2009.
-
Alignment of the Pixel and SCT Modules for the 2004 ATLAS Combined Test Beam
Authors:
A. Ahmad,
A. Andreazza,
T. Atkinson,
J. Baines,
A. J. Barr,
R. Beccherle,
P. J. Bell,
J. Bernabeu,
Z. Broklova,
P. A. Bruckman de Renstrom,
D. Cauz,
L. Chevalier,
S. Chouridou,
M. Citterio,
A. Clark,
M. Cobal,
T. Cornelissen,
S. Correard,
M. J. Costa,
D. Costanzo,
S. Cuneo,
M. Dameri,
G. Darbo,
J. B. de Vivie,
B. Di Girolamo
, et al. (104 additional authors not shown)
Abstract:
A small set of final prototypes of the ATLAS Inner Detector silicon tracker (Pixel and SCT) were used to take data during the 2004 Combined Test Beam. Data were collected from runs with beams of different flavour (electrons, pions, muons and photons) with a momentum range of 2 to 180 GeV/c. Four independent methods were used to align the silicon modules. The corrections obtained were validated u…
▽ More
A small set of final prototypes of the ATLAS Inner Detector silicon tracker (Pixel and SCT) were used to take data during the 2004 Combined Test Beam. Data were collected from runs with beams of different flavour (electrons, pions, muons and photons) with a momentum range of 2 to 180 GeV/c. Four independent methods were used to align the silicon modules. The corrections obtained were validated using the known momenta of the beam particles and were shown to yield consistent results among the different alignment approaches. From the residual distributions, it is concluded that the precision attained in the alignment of the silicon modules is of the order of 5 micrometers in their most precise coordinate.
△ Less
Submitted 26 May, 2008;
originally announced May 2008.
-
The detection of single electrons by means of a Micromegas-covered MediPix2 pixel CMOS readout circuit
Authors:
M. Campbell,
M. Chefdeville,
P. Colas,
A. P. Colijn,
A. Fornaini,
Y. Giomataris,
H. van der Graaf,
E. H. M Heijne,
P. Kluit,
X. Llopart,
J. Schmitz,
J. Timmermans,
J. L. Visschers
Abstract:
A small drift chamber was read out by means of a MediPix2 readout chip as direct anode. A Micromegas foil was placed 50 $μ$m above the chip, and electron multiplication occurred in the gap. With a He/Isobutane 80/20 mixture, gas multiplication factors up to tens of thousands were achieved, resulting in an efficiency for detecting single electrons of better than 90% . We recorded many frames cont…
▽ More
A small drift chamber was read out by means of a MediPix2 readout chip as direct anode. A Micromegas foil was placed 50 $μ$m above the chip, and electron multiplication occurred in the gap. With a He/Isobutane 80/20 mixture, gas multiplication factors up to tens of thousands were achieved, resulting in an efficiency for detecting single electrons of better than 90% . We recorded many frames containing 2D images with tracks from cosmic muons. Along these tracks, electron clusters were observed, as well as delta-rays.
△ Less
Submitted 9 September, 2004;
originally announced September 2004.