-
Long-distance chronometric leveling with a transportable optical clock
Authors:
J. Grotti,
I. Nosske,
S. B. Koller,
S. Herbers,
H. Denker,
L. Timmen,
G. Vishnyakova,
G. Grosche,
T. Waterholter,
A. Kuhl,
S. Koke,
E. Benkler,
M. Giunta,
L. Maisenbacher,
A. Matveev,
S. Dörscher,
R. Schwarz,
A. Al-Masoudi,
T. W. Hänsch,
T. H. Udem,
R. Holzwarth,
C. Lisdat
Abstract:
We have measured the geopotential difference between two locations separated by 457 km by comparison of two optical lattice clocks via an interferometric fiber link, utilizing the gravitational redshift of the clock transition frequency. The $^{87}$Sr clocks have been compared side-by-side before and after one of the clocks was moved to the remote location. The chronometrically measured geopotenti…
▽ More
We have measured the geopotential difference between two locations separated by 457 km by comparison of two optical lattice clocks via an interferometric fiber link, utilizing the gravitational redshift of the clock transition frequency. The $^{87}$Sr clocks have been compared side-by-side before and after one of the clocks was moved to the remote location. The chronometrically measured geopotential difference of $3918.1(2.4)\,\mathrm{m^2 \, s^{-2}}$ agrees with an independent geodetic determination of $3915.88(0.30)\,\mathrm{m^2 \, s^{-2}}$. The uncertainty of the chronometric geopotential difference is equivalent to an uncertainty of $24~\mathrm{cm}$ in height.
△ Less
Submitted 28 September, 2023; v1 submitted 26 September, 2023;
originally announced September 2023.
-
Calibration of a superconducting gravimeter with an absolute atom gravimeter
Authors:
S. Merlet,
P. Gillot,
B. Cheng,
R. Karcher,
A. Imanaliev,
L. Timmen,
F. Pereira Dos Santos
Abstract:
We present a 27-days long common view measurement of an absolute cold atom gravimeter (CAG) and a relative iGrav superconducting gravimeter, which we use to calibrate the iGrav scale factor. This allowed us to push the CAG long-term stability down to the level of 0.5~nm.s$^{-2}$. We investigate the impact of the duration of the measurement on the uncertainty in the determination of the correlation…
▽ More
We present a 27-days long common view measurement of an absolute cold atom gravimeter (CAG) and a relative iGrav superconducting gravimeter, which we use to calibrate the iGrav scale factor. This allowed us to push the CAG long-term stability down to the level of 0.5~nm.s$^{-2}$. We investigate the impact of the duration of the measurement on the uncertainty in the determination of the correlation factor and show that it is limited to about 3\textperthousand~by the coloured noise of our cold atom gravimeter. A 3-days long measurement session with an additional FG5X absolute gravimeter allows us to directly compare the calibration results obtained with two different absolute meters. Based on our analysis, we expect that with an improvement of its long term stability, the CAG will allow to calibrate the iGrav scale factor to better than the per mille level (1$σ$ level of confidence) after only one-day of concurrent measurements for maximum tidal amplitudes.
△ Less
Submitted 15 February, 2021; v1 submitted 20 July, 2020;
originally announced July 2020.
-
Gravity field modelling for the Hannover 10m atom interferometer
Authors:
Manuel Schilling,
Étienne Wodey,
Ludger Timmen,
Dorothee Tell,
Klaus H. Zipfel,
Dennis Schlippert,
Christian Schubert,
Ernst M. Rasel,
Jürgen Müller
Abstract:
Absolute gravimeters (AG) are used in geodesy, geophysics, and physics for a wide spectrum of applications. Stable gravimetric measurements over timescales from several days to decades are required to provide relevant insight into geophysical processes. Users of AGs participate in comparisons with a metrological reference in order to monitor the temporal stability of the instruments and determine…
▽ More
Absolute gravimeters (AG) are used in geodesy, geophysics, and physics for a wide spectrum of applications. Stable gravimetric measurements over timescales from several days to decades are required to provide relevant insight into geophysical processes. Users of AGs participate in comparisons with a metrological reference in order to monitor the temporal stability of the instruments and determine the bias to that reference. However, since no measurement standard of higher-order accuracy currently exists, users of AGs participate in key comparisons led by the CIPM. These comparisons provide the reference values of highest accuracy compared to the calibration against a single AG. The construction of stationary, large scale atom interferometers paves the way towards a new measurement standard in absolute gravimetry used as a reference with a potential stability up to 1 nm/s$^2$ at 1 s integration time. At the Leibniz University Hannover, we are currently building such a very long baseline atom interferometer with a 10 m long interaction zone. The knowledge of local gravity and its gradient along and around the baseline is required to establish the instrument's uncertainty budget and enable transfers of gravimetric measurements to nearby devices for comparison and calibration purposes. We therefore established a control network for relative gravimeters and repeatedly measured its connections during the construction of the atom interferometer. We additionally developed a 3D model of the host building to investigate the self-attraction effect and studied the impact of mass changes due to groundwater hydrology on the gravity field around the reference instrument. The gravitational effect from the building 3D model is in excellent agreement with the latest gravimetric measurement campaign which opens the possibility to transfer gravity values with an uncertainty below the 10 nm/s$^2$ level.
△ Less
Submitted 29 November, 2020; v1 submitted 10 March, 2020;
originally announced March 2020.
-
Direct comparisons of European primary and secondary frequency standards via satellite techniques
Authors:
F. Riedel,
A. Al-Masoudi,
E. Benkler,
S. Dörscher,
V. Gerginov,
C. Grebing,
S. Häfner,
N. Huntemann,
B. Lipphardt,
C. Lisdat,
E. Peik,
D. Piester,
C. Sanner,
C. Tamm,
S. Weyers,
H. Denker,
L. Timmen,
C. Voigt,
D. Calonico,
G. Cerretto,
G. A. Costanzo,
F. Levi,
I. Sesia,
J. Achkar,
J. Guèna
, et al. (24 additional authors not shown)
Abstract:
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taki…
▽ More
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taking into account correlations and gaps in the measurement data, combined overall uncertainties in the range of $1.8 \times 10^{-16}$ to $3.5 \times 10^{-16}$ for the optical clock comparisons were found. The comparison of the fountain clocks yields results with a maximum relative frequency difference of $6.9 \times 10^{-16}$, and combined overall uncertainties in the range of $4.8 \times 10^{-16}$ to $7.7 \times 10^{-16}$.
△ Less
Submitted 9 October, 2019;
originally announced October 2019.
-
Geodesy and metrology with a transportable optical clock
Authors:
Jacopo Grotti,
Silvio Koller,
Stefan Vogt,
Sebastian Häfner,
Uwe Sterr,
Christian Lisdat,
Heiner Denker,
Christian Voigt,
Ludger Timmen,
Antoine Rolland,
Fred N. Baynes,
Helen S. Margolis,
Michel Zampaolo,
Pierre Thoumany,
Marco Pizzocaro,
Benjamin Rauf,
Filippo Bregolin,
Anna Tampellini,
Piero Barbieri,
Massimo Zucco,
Giovanni A. Costanzo,
Cecilia Clivati,
Filippo Levi,
Davide Calonico
Abstract:
The advent of novel measurement instrumentation can lead to paradigm shifts in scientific research. Optical atomic clocks, due to their unprecedented stability and uncertainty, are already being used to test physical theories and herald a revision of the International System of units (SI). However, to unlock their potential for cross-disciplinary applications such as relativistic geodesy, a major…
▽ More
The advent of novel measurement instrumentation can lead to paradigm shifts in scientific research. Optical atomic clocks, due to their unprecedented stability and uncertainty, are already being used to test physical theories and herald a revision of the International System of units (SI). However, to unlock their potential for cross-disciplinary applications such as relativistic geodesy, a major challenge remains. This is their transformation from highly specialized instruments restricted to national metrology laboratories into flexible devices deployable in different locations. Here we report the first field measurement campaign performed with a ubiquitously applicable $^{87}$Sr optical lattice clock. We use it to determine the gravity potential difference between the middle of a mountain and a location 90 km apart, exploiting both local and remote clock comparisons to eliminate potential clock errors. A local comparison with a $^{171}$Yb lattice clock also serves as an important check on the international consistency of independently developed optical clocks. This campaign demonstrates the exciting prospects for transportable optical clocks.
△ Less
Submitted 11 May, 2017;
originally announced May 2017.
-
Comparison between two mobile absolute gravimeters: optical versus atomic interferometers
Authors:
S. Merlet,
Q. Bodart,
N. Malossi,
A. Landragin,
F. Pereira Dos Santos,
O. Gitlein,
L. Timmen
Abstract:
We report a comparison between two absolute gravimeters: the LNE-SYRTE cold atoms gravimeter and FG5#220 of Leibniz Universität of Hannover. They rely on different principles of operation: atomic and optical interferometry. Both are movable which enabled them to participated to the last International Comparison of Absolute Gravimeters (ICAG'09) at BIPM. Immediately after, their bilateral compariso…
▽ More
We report a comparison between two absolute gravimeters: the LNE-SYRTE cold atoms gravimeter and FG5#220 of Leibniz Universität of Hannover. They rely on different principles of operation: atomic and optical interferometry. Both are movable which enabled them to participated to the last International Comparison of Absolute Gravimeters (ICAG'09) at BIPM. Immediately after, their bilateral comparison took place in the LNE watt balance laboratory and showed an agreement of 4.3 +/- 6.4 μGal.
△ Less
Submitted 28 June, 2010; v1 submitted 3 May, 2010;
originally announced May 2010.