-
Active Healing of Microtubule-Motor Networks
Authors:
Fan Yang,
Shichen Liu,
Heun ** Lee,
Rob Phillips,
Matt Thomson
Abstract:
Cytoskeletal networks have a self-healing property where networks can repair defects to maintain structural integrity. However, both the mechanisms and dynamics of healing remain largely unknown. Here we report an unexplored healing mechanism in microtubule-motor networks by active crosslinking. We directly generate network cracks using a light-controlled microtubule-motor system, and observe that…
▽ More
Cytoskeletal networks have a self-healing property where networks can repair defects to maintain structural integrity. However, both the mechanisms and dynamics of healing remain largely unknown. Here we report an unexplored healing mechanism in microtubule-motor networks by active crosslinking. We directly generate network cracks using a light-controlled microtubule-motor system, and observe that the cracks can self-heal. Combining theory and experiment, we find that the networks must overcome internal elastic resistance in order to heal cracks, giving rise to a bifurcation of dynamics dependent on the initial opening angle of the crack: the crack heals below a critical angle and opens up at larger angles. Simulation of a continuum model reproduces the bifurcation dynamics, revealing the importance of a boundary layer where free motors and microtubules can actively crosslink and thereby heal the crack. We also formulate a simple elastic-rod model that can qualitatively predict the critical angle, which is found to be tunable by two dimensionless geometric parameters, the ratio of the boundary layer and network width, and the aspect ratio of the network. Our results provide a new framework for understanding healing in cytoskeletal networks and designing self-healable biomaterials.
△ Less
Submitted 30 June, 2024;
originally announced July 2024.
-
Theoretical Limits of Energy Extraction in Active Fluids
Authors:
Shahriar Shadkhoo,
Matt Thomson
Abstract:
Active materials form a class of far-from-equilibrium systems that are driven internally and exhibit self-organization which can be harnessed to perform mechanical work. Inspired by experiments on synthetic active networks we examine limits of work extraction from an active viscoelastic medium by analyzing the transport of a particle. The active viscoelastic material possesses an equilibrium densi…
▽ More
Active materials form a class of far-from-equilibrium systems that are driven internally and exhibit self-organization which can be harnessed to perform mechanical work. Inspired by experiments on synthetic active networks we examine limits of work extraction from an active viscoelastic medium by analyzing the transport of a particle. The active viscoelastic material possesses an equilibrium density where the active and passive forces are balanced out. In one dimension, a gliding activation front (AF) that converts a passive to an active medium, provides active energy at a constant rate, which is injected into the system at one end and propagates to the other. We demonstrate that there exists a maximum velocity of the AF, above which the activated region fails to deliver the transport power. We hypothesize, and intuitively argue based on the limit cases, that the feasibility and the velocity of transport can be interpreted in terms of the velocity of an equilibration Domain Wall of the field, which is set by two parameters: a measure of activity, and the viscoelastic timescale. The phase diagram comprises Transport and No-Transport sectors, namely for any pair of the two parameters, there exists a threshold velocity of the AF above which the particle transport becomes impossible. Constructing the phase diagram we find that there are regions of the phase diagram for which the threshold velocity of the AF diverges. Larger viscoelastic timescale makes the transport region more accessible, and increases the transport velocity therein. Also, we find that increasing the velocity of AF results in larger extracted power but smaller transport coefficient; the ratio of the transport velocity and that of the AF. Our model provides a framework for understanding the energetics of transport phenomena in biology, and designing efficient mechanisms of transport in synthetic active materials.
△ Less
Submitted 30 April, 2024; v1 submitted 2 July, 2023;
originally announced July 2023.
-
Strong coupling of plasmonic bright and dark modes with two eigenmodes of a photonic crystal cavity
Authors:
Fanqi Meng,
Lei Cao,
Aristeidis Karalis,
Hantian Gu,
Mark D. Thomson,
Hartmut G. Roskos
Abstract:
Dark modes represent a class of forbidden transitions or transitions with weak dipole moments between energy states. Due to their low transition probability, it is difficult to realize their interaction with light, let alone achieve the strong interaction of the modes with the photons in a cavity. However, by mutual coupling with a bright mode, the strong interaction of dark modes with photons is…
▽ More
Dark modes represent a class of forbidden transitions or transitions with weak dipole moments between energy states. Due to their low transition probability, it is difficult to realize their interaction with light, let alone achieve the strong interaction of the modes with the photons in a cavity. However, by mutual coupling with a bright mode, the strong interaction of dark modes with photons is possible. This type of mediated interaction is widely investigated in the metamaterials community and is known under the term electromagnetically induced transparency (EIT). Here, we report strong coupling between a plasmonic dark mode of an EIT-like metamaterial with the photons of a 1D photonic crystal cavity in the terahertz frequency range. The coupling between the dark mode and the cavity photons is mediated by a plasmonic bright mode, which is proven by the observation of a frequency splitting which depends on the strength of the inductive interaction between the plasmon bright and dark modes of the EIT-like metamaterial. In addition, since the plasmonic dark mode strongly couples with the cavity dark mode, we observes four polariton modes. The frequency splitting by interaction of the four modes (plasmonic bright and dark mode and the two eigenmodes of the photonic cavity) can be reproduced in the framework of a model of four coupled harmonic oscillators.
△ Less
Submitted 22 June, 2023;
originally announced June 2023.
-
600-GHz Fourier Imaging Based on Heterodyne Detection at the 2nd Sub-harmonic
Authors:
Hui Yuan,
Alvydas Lisauskas,
Mark D. Thomson,
Hartmut G. Roskos
Abstract:
Fourier imaging is an indirect imaging method which records the diffraction pattern of the object scene coherently in the focal plane of the imaging system and reconstructs the image using computational resources. The spatial resolution, which can be reached, depends on one hand on the wavelength of the radiation, but also on the capability to measure - in the focal plane - Fourier components with…
▽ More
Fourier imaging is an indirect imaging method which records the diffraction pattern of the object scene coherently in the focal plane of the imaging system and reconstructs the image using computational resources. The spatial resolution, which can be reached, depends on one hand on the wavelength of the radiation, but also on the capability to measure - in the focal plane - Fourier components with high spatial wave-vectors. This leads to a conflicting situation at THz frequencies, because choosing a shorter wavelength for better resolution usually comes at the cost of less radiation power, concomitant with a loss of dynamic range, which limits the detection of higher Fourier components. Here, aiming at maintaining a high dynamic range and limiting the system costs, we adopt heterodyne detection at the 2nd sub-harmonic, working with continuous-wave (CW) radiation for object illumination at 600 GHz and local-oscillator (LO) radiation at 300 GHz. The detector is a single-pixel broad-band Si CMOS TeraFET equipped with substrate lenses on both the front- and backside for separate in-coupling of the waves. The entire scene is illuminated by the object wave, and the Fourier spectrum is recorded by raster scanning of the single detector unit through the focal plane. With only 56 uW of power of the 600-GHz radiation, a dynamic range of 60 dB is reached, sufficient to detect the entire accessible Fourier space spectrum in the test measurements. A lateral spatial resolution of better than 0.5 mm, at the diffraction limit, is reached.
△ Less
Submitted 2 June, 2023;
originally announced June 2023.
-
Multiscale Monte Carlo simulations of gold nanoparticle dose-enhanced radiotherapy II. Cellular dose enhancement within macroscopic tumor models
Authors:
Martin P. Martinov,
Elizabeth M. Fletcher,
Rowan M. Thomson
Abstract:
Purpose: To develop and apply multiscale Monte Carlo (MC) simulations to assess variations in nucleus and cytoplasm dose enhancement factors (n,cDEFs) over tumor-scale volumes. Methods: The intrinsic variation of n,cDEFs (due to variations in local gold concentration and cell/nucleus size) are estimated via MC modeling of varied cellular GNP uptake and cell/nucleus sizes. Then, a Heterogeneous Mul…
▽ More
Purpose: To develop and apply multiscale Monte Carlo (MC) simulations to assess variations in nucleus and cytoplasm dose enhancement factors (n,cDEFs) over tumor-scale volumes. Methods: The intrinsic variation of n,cDEFs (due to variations in local gold concentration and cell/nucleus size) are estimated via MC modeling of varied cellular GNP uptake and cell/nucleus sizes. Then, a Heterogeneous MultiScale (HetMS) model is implemented by combining detailed models of populations of cells containing GNPs with simplified tissue models to evaluate n,cDEFs. Simulations of tumors with spatially-uniform and -varying gold concentrations are performed to determine n,cDEFs as a function of distance from the source. All simulations are performed for three different GNP configurations: GNPs distributed around the nucleus or packed into one or four endosome(s). Results: Intrinsic variations in n,cDEFs can be substantial with changes in GNP uptake and cell/nucleus radii. In HetMS models of tumors, sub-unity n,cDEFs (dose decreases) can occur for low energies and high gold concentrations due to attenuation of primary photons through the gold. In HetMS simulations of tumors with spatially-uniform gold concentrations, n,cDEFs decrease with depth into the tumor as photons are attenuated, with relative differences between GNP models remaining approximately constant with depth in the tumor. Similar initial n,cDEF decreases with radius are seen in tumors with spatially-varying gold concentrations, but n,cDEFs for all configurations converge to a single value for each energy as gold concentration reaches zero. Conclusions: These results demonstrate that cellular doses are highly sensitive to cell/nucleus size, GNP intracellular distribution, gold concentration, and cell position in the tumor. This work demonstrates the importance of proper choice of computational model when simulating GNPT scenarios.
△ Less
Submitted 2 May, 2023;
originally announced May 2023.
-
Multiscale Monte Carlo simulations of gold nanoparticle dose-enhanced radiotherapy I. Cellular dose enhancement in microscopic models
Authors:
Martin P. Martinov,
Elizabeth M. Fletcher,
Rowan M. Thomson
Abstract:
Purpose: The introduction of Gold NanoParticles (GNPs) in radiotherapy requires consideration of GNP size, location, and quantity, and more, as well as beam quality. The work is presented in two parts, with Part I (this work) investigating accurate and efficient MC modeling to calculate nucleus and cytoplasm Dose Enhancement Factors (n,cDEFs). Part II then evaluates cell dose enhancement factors a…
▽ More
Purpose: The introduction of Gold NanoParticles (GNPs) in radiotherapy requires consideration of GNP size, location, and quantity, and more, as well as beam quality. The work is presented in two parts, with Part I (this work) investigating accurate and efficient MC modeling to calculate nucleus and cytoplasm Dose Enhancement Factors (n,cDEFs). Part II then evaluates cell dose enhancement factors across macroscopic length scales. Methods: Different methods of modeling gold within cells are compared: a contiguous volume of either pure gold or gold-tissue mixture or discrete GNPs. MC simulations with EGSnrc are performed to calculate n,cDEF for a cell considering 10 to 370 keV incident photons, gold concentrations from 4 to 24~mg of gold per gram, and three different GNP configurations: GNPs distributed around the surface of the nucleus or packed into one or four endosomes. Results: n,cDEFs are sensitive to the model of gold in the cell, with differences of up to 17% observed between models. Across cell/nucleus radii, source energies, and gold concentrations, n,cDEF are highest for GNPs in the perinuclear configuration, compared with GNPs in endosomes. Across all simulations of the default cell, nDEFs and cDEFs range from one to 6.83 and 3.87, respectively. If the cell size is changed, much higher n,cDEFs are observed. n,cDEF are maximized at photon energies at or just above the K- or L-edges of gold. Conclusions: This work demonstrates many physics trends on DEFs at the cellular level, including that cellular DEFs are sensitive to gold modeling approach, GNP configuration, cell/nucleus size, gold concentration, and incident source energy. These data will allow one to optimize or estimate DEF using not only GNP uptake, but account for incident photon energy and intracellular configuration of GNPs. Part II will expand the investigation, applying the cell model in cm-scale phantoms.
△ Less
Submitted 2 May, 2023;
originally announced May 2023.
-
Higher-harmonic generation in boron-doped silicon from band carriers and bound-dopant photoionization
Authors:
Fanqi Meng,
Frederik Walla,
Sergey Kovalev,
Jan-Christoph Deinert,
Igor Ilyakov,
Min Chen,
Alexey Ponomaryov,
Sergey G. Pavlov,
Heinz-Wilhelm Hubers,
Nikolay V. Abrosimov,
Christoph Jungemann,
Hartmut G. Roskos,
Mark D. Thomson
Abstract:
We investigate ultrafast harmonic generation (HG) in Si:B, driven by intense pump pulses with fields reaching ~100 kV/cm and a carrier frequency of 300 GHz, at 4 K and 300 K, both experimentally and theoretically. We report several novel findings concerning the nonlinear charge carrier dynamics in intense sub-THz fields. (i) Harmonics of order up to n=9 are observed at room temperature, while at l…
▽ More
We investigate ultrafast harmonic generation (HG) in Si:B, driven by intense pump pulses with fields reaching ~100 kV/cm and a carrier frequency of 300 GHz, at 4 K and 300 K, both experimentally and theoretically. We report several novel findings concerning the nonlinear charge carrier dynamics in intense sub-THz fields. (i) Harmonics of order up to n=9 are observed at room temperature, while at low temperature we can resolve harmonics reaching even n=13. The susceptibility per charge carrier at moderate field strength is as high as for charge carriers in graphene, considered to be one of the materials with the strongest sub-THz nonlinear response. (ii) For T=300 K, where the charge carriers bound to acceptors are fully thermally ionized into the valence subbands, the susceptibility values decrease with increasing field strength. Simulations incorporating multi-valence-band Monte-Carlo and finite-difference-time-domain (FDTD) propagation show that here, the HG process becomes increasingly dominated by energy-dependent scattering rates over the contribution from band non-parabolicity, due to the onset of optical-phonon emission, which ultimately leads to the saturation at high fields. (iii) At T=4 K, where the majority of charges are bound to acceptors, we observe a drastic rise of the HG yields for internal pump fields of 30 kV/cm, as one reaches the threshold for tunnel ionization. We disentangle the HG contributions in this case into contributions from the initial 'generational'- and subsequent band-nonlinearities, and show that scattering seriously degrades any coherent recollision during the subsequent oscillation of the holes.
△ Less
Submitted 2 March, 2023;
originally announced March 2023.
-
Update of the CLRP Monte Carlo TG-43 parameter database for high-energy brachytherapy sources
Authors:
Habib Safigholi,
Marc J. P. Chamberland,
Randle E. P. Taylor,
Martin P. Martinov,
D. W. O. Rogers,
Rowan M. Thomson
Abstract:
PURPOSE: To update and extend version 2 of the Carleton Laboratory for Radiotherapy Physics (CLRP) TG-43 dosimetry database (CLRP_TG43v2) for 33 high-energy (HE, $\geq50$~keV) brachytherapy sources using egs_brachy, an open-source EGSnrc application. A comprehensive dataset of TG-43 parameters is compiled, including detailed source descriptions, dose-rate constants, radial dose functions, 1D and 2…
▽ More
PURPOSE: To update and extend version 2 of the Carleton Laboratory for Radiotherapy Physics (CLRP) TG-43 dosimetry database (CLRP_TG43v2) for 33 high-energy (HE, $\geq50$~keV) brachytherapy sources using egs_brachy, an open-source EGSnrc application. A comprehensive dataset of TG-43 parameters is compiled, including detailed source descriptions, dose-rate constants, radial dose functions, 1D and 2D anisotropy functions, along-away dose-rate tables, Primary and Scatter Separated (PSS) dose tables, and mean photon energies esca** each source. The database also documents the source models which will be freely distributed with egs_brachy. ACQUISITION AND VALIDATION METHODS: Datasets are calculated after a recoding of the source geometries using the egs++ geometry package and its egs_brachy extensions. Air kerma per history is calculated in a 10x10x0.05 cm3 voxel located 100 cm from the source along the transverse axis and then corrected for the lateral and thickness dimensions of the scoring voxel to give the air kerma on the central axis at a point 100cm from the source's mid-point. Full-scatter water phantoms with varying voxel resolutions in cylindrical coordinates are used for dose calculations. For validation, data are compared to those from CLRP_TG43v1 and published data. DATA FORMAT AND ACCESS: Data are available at https://physics.carleton.ca/clrp/egs_brachy/seed_database_HDRv2 or http://doi.org/10.22215/clrp/tg43v2. POTENTIAL APPLICATIONS: The CLRP_TG43v2 database has applications in research, dosimetry, and brachytherapy planning. This comprehensive update provides the medical physics community with more precise and in some cases more accurate Monte Carlo TG-43 dose calculation parameters, as well as fully benchmarked and described source models which are distributed with egs_brachy.
△ Less
Submitted 7 December, 2022;
originally announced December 2022.
-
Spatiotemporal patterning of extensile active stresses in microtubule-based active fluids
Authors:
Linnea M. Lemma,
Minu Varghese,
Tyler D. Ross,
Matt Thomson,
Aparana Baskaran,
Zvonimir Dogic
Abstract:
Active stresses, which are collectively generated by the motion of energy-consuming rod-like constituents, generate chaotic autonomous flows. Controlling active stresses in space and time is an essential prerequisite for controlling the intrinsically chaotic dynamics of extensile active fluids. We design single-headed kinesin molecular motors that exhibit optically enhanced clustering, and thus en…
▽ More
Active stresses, which are collectively generated by the motion of energy-consuming rod-like constituents, generate chaotic autonomous flows. Controlling active stresses in space and time is an essential prerequisite for controlling the intrinsically chaotic dynamics of extensile active fluids. We design single-headed kinesin molecular motors that exhibit optically enhanced clustering, and thus enable precise and repeatable spatial and temporal control of extensile active stresses. Such motors enable rapid, reversible switching between flowing and quiescent states. In turn, spatio-temporal patterning of the active stress controls the evolution of the ubiquitous bend-instability of extensile active fluids and determines its critical length dependence. Combining optically controlled clusters with conventional kinesin motors enables one-time switching from contractile to extensile active stresses. These results open a path towards real-time control of the autonomous flows generated by active fluids.
△ Less
Submitted 13 September, 2022;
originally announced September 2022.
-
Dynamic Flow Control Through Active Matter Programming Language
Authors:
Fan Yang,
Shichen Liu,
Heun ** Lee,
Rob Phillips,
Matt Thomson
Abstract:
Cells control fluid flows with a spatial and temporal precision that far exceeds the capabilities of current microfluidic technologies. Cells achieve this superior spatio-temporal control by harnessing dynamic networks of cytoskeleton and motor proteins. Thus, engineering systems to mimic cytoskeletal protein networks could lead to the development of a new, active-matter-powered microfluidic devic…
▽ More
Cells control fluid flows with a spatial and temporal precision that far exceeds the capabilities of current microfluidic technologies. Cells achieve this superior spatio-temporal control by harnessing dynamic networks of cytoskeleton and motor proteins. Thus, engineering systems to mimic cytoskeletal protein networks could lead to the development of a new, active-matter-powered microfluidic device with improved performance over the existing technologies. However, reconstituted motor-microtubule systems conventionally generate chaotic flows and cannot perform useful tasks. Here, we develop an all-optical platform for programming flow fields for transport, separation and mixing of cells and particles using networks of microtubules and motor proteins reconstituted in vitro. We employ mathematical modeling for design optimization, which enables the construction of flow fields that achieves micron-scale transport. We use the platform to demonstrate that active-matter-generated flow fields can probe the extensional rheology of polymers, such as DNA, achieve transport and mixing of beads and human cells, and isolation of human cell clusters. Our findings provide a bio-inspired pathway for programmatically engineering dynamic micron-scale flows and demonstrate the vast potential of active matter systems as an engineering technology.
△ Less
Submitted 5 October, 2023; v1 submitted 26 August, 2022;
originally announced August 2022.
-
Fast full patient and radioisotope Monte Carlo simulations of targeted radionuclide therapy: introducing egs_mird
Authors:
Martin P. Martinov,
Chidera Opera,
Rowan M. Thomson,
Ting-Yim Lee
Abstract:
BACKGROUND: Targeted Radionuclide Therapy (TRT) is a fast-growing field garnering much interest, however, dosimetry calculation techniques remain relatively simple. PURPOSE: To introduce egs_mird, a new Monte Carlo application built in EGSnrc which allows users to model full patient tissue and density (using clinical CT images) and radionuclide distribution (using clinical PET images) for fast and…
▽ More
BACKGROUND: Targeted Radionuclide Therapy (TRT) is a fast-growing field garnering much interest, however, dosimetry calculation techniques remain relatively simple. PURPOSE: To introduce egs_mird, a new Monte Carlo application built in EGSnrc which allows users to model full patient tissue and density (using clinical CT images) and radionuclide distribution (using clinical PET images) for fast and detailed TRT dose calculation. METHODS: The novel application egs_mird is introduced, including its structure and variation reduction approaches. A new egs++ source class egs_internal_source and a modified version of egs_radionuclide_source are described. The new code is compared to other MC calculations of S-value kernels, along with self-validation using the electron Fano test. Full patient prostate 177Lu TRT cancer treatment simulations are performed using a single set of patient DICOM CT and [18F]-DCFPyL PET data. RESULTS: Good agreement is found between S-value kernels calculated using egs_mird and those found in the literature. The Fano test is satisfied to 0.1%. Patient prostate, rectum, bone marrow, and bladder dose volume histogram results did not vary significantly when using the track-length estimator and not modelling electron transport, modelling bone marrow explicitly (rather than using generic tissue compositions), and reducing activity to voxels containing partial or full calcifications to half or none, respectively. Simulations using the track-length estimator can be completed in under 15 minutes. CONCLUSION: This work shows egs mird to be a reliable MC code for computing TRT doses as realistically as the patient CT and PET data allow, supporting the use of egs mird for dose calculations in TRT.
△ Less
Submitted 4 April, 2022;
originally announced April 2022.
-
Technical Note: MC-GPU breast dosimetry validations with other Monte Carlo codes and Phase Space File implementation
Authors:
Rodrigo T. Massera,
Rowan M. Thomson,
Alessandra Tomal
Abstract:
Purpose: To validate the MC-GPU Monte Carlo code for dosimetric studies in x-ray breast imaging modalities: mammography, digital breast tomosynthesis, contrast enhanced digital mammography and breast-CT. Moreover, to implement and validate a phase space file generation routine. Methods: The MC-GPU code (v. 1.5 DBT) was modified in order to generate phase space files and to be compatible with PENEL…
▽ More
Purpose: To validate the MC-GPU Monte Carlo code for dosimetric studies in x-ray breast imaging modalities: mammography, digital breast tomosynthesis, contrast enhanced digital mammography and breast-CT. Moreover, to implement and validate a phase space file generation routine. Methods: The MC-GPU code (v. 1.5 DBT) was modified in order to generate phase space files and to be compatible with PENELOPE v. 2018 derived cross section database. Simulations were performed with homogeneous and anthropomorphic breast phantoms for different breast imaging techniques. The glandular dose was computed for each case and compared with results from the PENELOPE (v. 2014) + penEasy (v. 2015) and egs brachy (EGSnrc) Monte Carlo codes. Afterwards, several phase space files were generated with MC-GPU and the scored photon spectra were compared between the codes. Results: MC-GPU showed good agreement with the other codes when calculating the glandular dose distribution for mammography, mean glandular dose for digital breast tomosynthesis, and normalized glandular dose for breast-CT. The latter case showed average/maximum relative differences of 2.3%/27%, respectively, compared to other literature works, with the larger differences observed at low energies (around 10 keV). The recorded photon spectra entering a voxel were similar (within statistical uncertainties) between the three Monte Carlo codes. Conclusions: The results indicate that MC-GPU code is suitable for breast dosimetric studies for different x-ray breast imaging modalities, with the advantage of a high performance. The phase space file implementation was validated and is compatible with the IAEA standard, allowing multiscale Monte Carlo simulations with a combination of CPU and GPU codes.
△ Less
Submitted 12 November, 2021;
originally announced November 2021.
-
High spatial resolution dosimetry with uncertainty analysis using Raman micro-spectroscopy readout of radiochromic films
Authors:
Connor Mcnairn,
Iymad Mansour,
Bryan Muir,
Rowan M. Thomson,
Sangeeta Murugkar
Abstract:
Purpose: The purpose of this work is to develop a new approach for high spatial resolution dosimetry based on Raman micro-spectroscopy scanning of radiochromic film (RCF). We generate dose calibration curves over an extended dose range from 0-50 Gy and with improved sensitivity to low (<2 Gy) doses, in addition to evaluating uncertainties. Methods: Samples of RCF (EBT3) were irradiated at a broad…
▽ More
Purpose: The purpose of this work is to develop a new approach for high spatial resolution dosimetry based on Raman micro-spectroscopy scanning of radiochromic film (RCF). We generate dose calibration curves over an extended dose range from 0-50 Gy and with improved sensitivity to low (<2 Gy) doses, in addition to evaluating uncertainties. Methods: Samples of RCF (EBT3) were irradiated at a broad dose-range of 0.03 Gy-50 Gy. Raman spectra were acquired with a custom-built Raman micro-spectroscopy setup involving a 500 mW, multimode 785 nm laser. The depth of focus of 34 um enabled the concurrent collection of Raman spectra from the RCF active layer and the polyester laminate. The pre-processed Raman spectra were normalized to the intensity of the 1614 cm-1 Raman peak from the polyester laminate that was unaltered by radiation. The experimental, fitting and total dose uncertainty was determined across the entire dose range for the dosimetry system of Raman micro-spectroscopy and RCF. Results: High resolution in the dose response of the RCF, even down to 0.03 Gy, was obtained in this study. The dynamic range of the calibration curves based on all three Raman peaks in the RCF extended up to 50 Gy with no saturation. At a spatial resolution of 30X30 um^2, the total uncertainty in estimating dose in the 0.5 Gy to 50 Gy dose range was [6 - 9]% for all three Raman calibration curves. This consisted of the experimental uncertainty of [5 - 8]%, and the fitting uncertainty of [2.5 - 4.5]%. Conclusions: The high spatial resolution experimental dosimetry technique based on Raman micro-spectroscopy and RCF presented here, could become useful for applications in, as well as for applications based on small field dosimetry.
△ Less
Submitted 4 May, 2021;
originally announced May 2021.
-
A study of Type B uncertainties associated with the photoelectric effect in low-energy Monte Carlo simulations
Authors:
Christian Valdes-Cortez,
Iymad Mansour,
Mark J. Rivard,
Facundo Ballester,
Ernesto Mainegra-Hing,
Rowan M. Thomson,
Javier Vijande
Abstract:
The goal of this manuscript is to estimate Type B uncertainties in absorbed-dose calculations arising from the different implementations in current state-of-the-art Monte Carlo codes of low-energy photon cross-sections (<200 keV). Monte Carlo simulations are carried out using three codes widely used in the low-energy domain: PENELOPE-2018, EGSnrc, and MCNP. Mass energy-absorption coefficients for…
▽ More
The goal of this manuscript is to estimate Type B uncertainties in absorbed-dose calculations arising from the different implementations in current state-of-the-art Monte Carlo codes of low-energy photon cross-sections (<200 keV). Monte Carlo simulations are carried out using three codes widely used in the low-energy domain: PENELOPE-2018, EGSnrc, and MCNP. Mass energy-absorption coefficients for water, air, graphite, and their respective ratios; absorbed dose; and photon-fluence spectra are considered. Benchmark simulations using similar cross-sections have been performed. The differences observed between these quantities when different cross-sections are considered are taken to be a good estimator for the corresponding Type B uncertainties. A conservative Type B uncertainty for the absorbed dose (k=2) of 1.2%-1.7% (<50 keV), 0.6%-1.2% (50-100 keV), and 0.3% (100-200 keV) is estimated. The photon-fluence spectrum does not present clinically relevant differences that merit considering additional Type B uncertainties except for energies below 25 keV, where a Type B uncertainty of 0.5% is obtained. Below 30 keV, mass energy-absorption coefficients show Type B uncertainties (k=2) of about 1.5% (water and air), and 2% (graphite), reaching values about 1% (40-50 keV) and 0.5% (50-75 keV). Type B uncertainties for the water-to-graphite ratios are observed for energies below 30 keV, about 0.7% (k=2). In contrast with the intermediate (about 500 keV) or high (about 1 MeV) energy domains, Type B uncertainties due to the different cross-sections implementation cannot be considered subdominant with respect to Type A uncertainties or even to other sources of Type B uncertainties. Therefore, the values reported here should be accommodated within the uncertainty budget in low-energy photon dosimetry studies.
△ Less
Submitted 4 March, 2021;
originally announced March 2021.
-
Update of the CLRP eye plaque brachytherapy database for photon-emitting sources
Authors:
Habib Safigholi,
Zack Parsons,
Stephen G. Deering,
Rowan M. Thomson
Abstract:
Purpose: To update and extend the Carleton Laboratory for Radiotherapy Physics (CLRP) Eye Plaque (EP) dosimetry database for low-energy photon-emitting brachytherapy sources using egs_brachy, an open-source EGSnrc application. The previous database, CLRP_EPv1, contained datasets for the Collaborative Ocular Melanoma Study (COMS) plaques (2008). The new database, CLRP EPv2, consists of newly-calcul…
▽ More
Purpose: To update and extend the Carleton Laboratory for Radiotherapy Physics (CLRP) Eye Plaque (EP) dosimetry database for low-energy photon-emitting brachytherapy sources using egs_brachy, an open-source EGSnrc application. The previous database, CLRP_EPv1, contained datasets for the Collaborative Ocular Melanoma Study (COMS) plaques (2008). The new database, CLRP EPv2, consists of newly-calculated 3D dose distributions for 17 plaques [8 COMS, 5 Eckert & Ziegler BEBIG, and 4 other representative models] for Pd-103, I-125, and Cs-131 seeds.
Methods: Plaque models are developed with egs_brachy, based on published/manufacturer dimensions and material data. The BEBIG plaques are identical in dimensions to COMS plaques but differ in elemental composition and/or density. Eye plaques and seeds are simulated at the centre of full-scatter water phantoms, scoring in (0.05 cm)^3 voxels spanning the eye for scenarios: (i) HOMO: simulated TG43 conditions; (ii) HETERO: eye plaques and seeds fully modelled; (iii) HETsi (BEBIG only): one seed is active at a time with other seed geometries present but not emitting photons (inactive). For validation, doses are compared to those from CLRP_EPv1 and published data.
Data Format and Access: Data are available at https://physics.carleton.ca/ clrp/eye_plaque_v2, http://doi.org/10.22215/clrp/EPv2. The data consist of 3D dose distributions (text-based EGSnrc 3ddose file) and graphical presentations of the comparisons to previously published data.
Potential Applications: The CLRP EPv2 database provides accurate reference 3D dose distributions to advance ocular brachytherapy dose evaluations. The fully-benchmarked eye plaque models will be freely-distributed with egs brachy, supporting adoption of model-based dose evaluations as recommended by TG-129, TG-186, and TG-221.
△ Less
Submitted 5 February, 2021;
originally announced February 2021.
-
Dosimetric investigation of 103Pd permanent breast seed implant brachytherapy based on Monte Carlo calculations
Authors:
Stephen G. Deering,
Michelle Hilts,
Deidre Batchelar,
Juanita Crook,
Rowan M. Thomson
Abstract:
PURPOSE: Permanent breast seed implant (PBSI) using 103Pd is emerging as an effective adjuvant radiation technique for early-stage breast cancer. However, clinical dose evaluations follow the water-based TG-43 approach with its considerable approximations. Towards clinical adoption of advanced TG-186 model-based dose evaluations, this study presents a comprehensive investigation for PBSI consideri…
▽ More
PURPOSE: Permanent breast seed implant (PBSI) using 103Pd is emerging as an effective adjuvant radiation technique for early-stage breast cancer. However, clinical dose evaluations follow the water-based TG-43 approach with its considerable approximations. Towards clinical adoption of advanced TG-186 model-based dose evaluations, this study presents a comprehensive investigation for PBSI considering both target and normal tissue doses. METHODS: Dose calculations are performed with the free open-source Monte Carlo (MC) code, egs_brachy, using 2 types of virtual patient models: TG43sim (simulated TG-43 conditions: all water with no interseed attenuation) and MCref (heterogeneous tissue modelling from patient CT, interseed attenuation, seeds at implant angle) for 35 patients. Sensitivity of dose metrics to seed orientation and the threshold for glandular/adipose tissue segmentation are assessed. RESULTS: In the target volume, D90 is 14.1% lower with MCref than with TG43sim, on average. Conversely, normal tissue doses are generally higher with MCref than with TG43sim, e.g., by 22% for skin D1cm2, 82% for ribs Dmax, and 71% for heart D1cm3. Discrepancies between MCref and TG43sim doses vary over the patient cohort, as well as with the tissue and metric considered. Doses are sensitive to the glandular/adipose tissue segmentation threshold with differences of a few percent in target D90. Skin doses are sensitive to seed orientation. CONCLUSIONS: TG-43 dose evaluations generally underestimate doses to critical normal organs/tissues while overestimating target doses. There is considerable variation in MCref and TG43sim on a patient-by-patient basis, suggesting that clinical adoption of patient-specific MC dose calculations is motivated. The MCref framework presented herein provides a consistent modelling approach for clinical implementation of advanced TG-186 dose calculations.
△ Less
Submitted 29 December, 2020;
originally announced December 2020.
-
Persistent fluid flows defined by active matter boundaries
Authors:
Zijie Qu,
Dominik Schildknecht,
Shahriar Shadkhoo,
Enrique Amaya,
Jialong Jiang,
Heun ** Lee,
Rob Phillips,
Matt Thomson
Abstract:
Biological systems achieve precise control over ambient fluids through the self-organization of active protein structures including flagella, cilia, and cytoskeletal networks. In active structures individual proteins consume chemical energy to generate force and motion at molecular length scales. Self-organization of protein components enables the control and modulation of fluid flow fields on mic…
▽ More
Biological systems achieve precise control over ambient fluids through the self-organization of active protein structures including flagella, cilia, and cytoskeletal networks. In active structures individual proteins consume chemical energy to generate force and motion at molecular length scales. Self-organization of protein components enables the control and modulation of fluid flow fields on micron scales. The physical principles underlying the organization and control of active-matter driven fluid flows are poorly understood. Here, we apply an optically-controlled active-matter system composed of microtubule filaments and light-switchable kinesin motor proteins to analyze the emergence of persistent flow fields in a model active matter system. Using light, we form contractile microtubule networks of varying shape. We analyze the fluid flow fields generated by a wide range of microtubule network geometries and explain the resulting flow fields within a unified theoretical framework. We specifically demonstrate that the geometry of microtubule flux at the boundary of contracting microtubule networks predicts the steady-state fluid flow fields across polygonal network geometries through finite-element simulations. Our work provides a foundation for programming microscopic fluid-flows with controllable active matter and could enable the engineering of versatile and dynamic microfluidic devices.
△ Less
Submitted 29 September, 2020;
originally announced October 2020.
-
Heterogeneous multiscale Monte Carlo simulations for gold nanoparticle radiosensitization
Authors:
Martin P. Martinov,
Rowan M. Thomson
Abstract:
To introduce the heterogeneous multiscale (HetMS) model for Monte Carlo simulations of gold nanoparticle dose-enhanced radiation therapy (GNPT), a model characterized by its varying levels of detail on different length scales within a single phantom; to apply the HetMS model in two different scenarios relevant for GNPT and to compare computed results with others published. The HetMS model is imple…
▽ More
To introduce the heterogeneous multiscale (HetMS) model for Monte Carlo simulations of gold nanoparticle dose-enhanced radiation therapy (GNPT), a model characterized by its varying levels of detail on different length scales within a single phantom; to apply the HetMS model in two different scenarios relevant for GNPT and to compare computed results with others published. The HetMS model is implemented in EGSnrc; the code is tested via comparisons with published data from independent gold nanoparticle (GNP) simulations. Two distinct scenarios for the HetMS model are considered: (1) monoenergetic photon beams incident on a large cylinder; (2) isotropic point source at the center of a large sphere with GNPs diffusing from the center. Dose enhancement factors (DEFs) are compared for different source energies, depths, gold concentrations, GNP sizes, and modeling assumptions. Simulation efficiencies are investigated. The HetMS MC simulations account for the competing effects of photon fluence perturbation coupled with enhanced local energy deposition. DEFs are most sensitive to these effects for lower source energies, varying with distance from the source; DEFs below unity can occur at energies relevant for brachytherapy. Compared to discrete modeling of GNPs throughout the gold-containing volume, efficiencies are enhanced by up to a factor of 122 with the HetMS approach. For the spherical phantom, DEFs vary with time for diffusion, radionuclide, and radius. By combining geometric models of varying complexity on different length scales within a single simulation, the HetMS model can effectively account for both macroscopic and microscopic effects. Efficiency gains with the HetMS approach enable diverse calculations which would otherwise be prohibitively long. The HetMS model may be extended to diverse scenarios relevant for GNPT, providing further avenues for research and development.
△ Less
Submitted 29 July, 2020;
originally announced July 2020.
-
Update of the CLRP TG-43 parameter database for low-energy brachytherapy sources
Authors:
Habib Safigholi,
Marc J. P. Chamberland,
Randle E. P. Taylor,
Christian H. Allen,
Martin P. Martinov,
D. W. O. Rogers,
Rowan M. Thomson
Abstract:
PURPOSE: To update the Carleton Laboratory for Radiotherapy Physics (CLRP) TG-43 dosimetry database for low-energy (< 50 keV) photon-emitting low-dose rate (LDR) brachytherapy sources utilizing the open-source EGSnrc application egs_brachy rather than the BrachyDose application used previously for 27 LDR sources in the 2008 CLRP version (CLRPv1). CLRPv2 covers 40 sources (Pd-103, I-125, Cs-131). A…
▽ More
PURPOSE: To update the Carleton Laboratory for Radiotherapy Physics (CLRP) TG-43 dosimetry database for low-energy (< 50 keV) photon-emitting low-dose rate (LDR) brachytherapy sources utilizing the open-source EGSnrc application egs_brachy rather than the BrachyDose application used previously for 27 LDR sources in the 2008 CLRP version (CLRPv1). CLRPv2 covers 40 sources (Pd-103, I-125, Cs-131). A comprehensive set of TG-43 parameters is calculated, including dose-rate constants, radial dose functions with functional fitting parameters, 1D and 2D anisotropy functions, along-away dose-rate tables, Primary-Scatter separation dose tables (for some sources), and mean photon energies. The database also documents the source models which will become part of the egs_brachy distribution. METHODS: Datasets are calculated after a systematic recoding of the source geometries using the egs++ geometry package and its egs_brachy extensions. Full scatter water phantoms with varying voxel resolutions in cylindrical coordinates are used for dose calculations. New statistical uncertainties of source volume corrections for phantom voxels which overlap with brachytherapy sources are implemented in egs_brachy, and all CLRPv2 data include these uncertainties. For validation, data are compared to CLRPv1 and other data in the literature. DATA ACCESS/FORMAT: Data are available at https://physics.carleton.ca/ clrp/egs_brachy/seed_database_v2. As well as being presented graphically in comparisons to previous calculations, data are available in Excel (.xlsx) spreadsheets for each source. APPLICATIONS: The database has applications in research, dosimetry, and brachytherapy planning. This comprehensive update provides the medical physics community with more accurate TG-43 dose evaluation parameters, as well as fully-benchmarked source models distributed with egs_brachy.
△ Less
Submitted 6 May, 2020;
originally announced May 2020.
-
3-D Printed Swimming Microtori for Cargo Transport and Flow Manipulation
Authors:
Remmi Baker,
Thomas Montenegro-Johnson,
Anton D. Sediako,
Murray J. Thomson,
Ayusman Sen,
Eric Lauga,
Igor. S. Aranson
Abstract:
Through billions of years of evolution, microorganisms mastered unique swimming behaviors to thrive in complex fluid environments. Limitations in nanofabrication have thus far hindered the ability to design and program synthetic swimmers with the same abilities. Here we encode multi-behavioral responses in artificial swimmers such as microscopic, self-propelled tori using nanoscale 3D printing. We…
▽ More
Through billions of years of evolution, microorganisms mastered unique swimming behaviors to thrive in complex fluid environments. Limitations in nanofabrication have thus far hindered the ability to design and program synthetic swimmers with the same abilities. Here we encode multi-behavioral responses in artificial swimmers such as microscopic, self-propelled tori using nanoscale 3D printing. We show experimentally and theoretically that the tori continuously transition between two primary swimming modes in response to a magnetic field. The tori also manipulate and transport other artificial swimmers, bimetallic nanorods, as well as passive colloidal particles. In the first behavioral mode, the tori accumulate and transport nanorods; in the second mode, nanorods align along the tori's self-generated streamlines. Our results indicate that such shape-programmed microswimmers have the potential to manipulate biological active matter, e.g. bacteria or cells.
△ Less
Submitted 1 April, 2020;
originally announced April 2020.
-
Taking EGSnrc to new lows: Development of egs++ lattice geometry and testing with microscopic
Authors:
Martin P. Martinov,
Rowan M. Thomson
Abstract:
Purpose: This work introduces a new lattice geometry library, egs_lattice, into the EGSnrc Monte Carlo code, which can be used for both modeling very large (previously unfeasible) quantities of geometries and establishing recursive boundary conditions. The reliability of egs_lattice, as well as EGSnrc in general, is cross-validated and tested. Methods: New Bravais, cubic, and hexagonal lattice geo…
▽ More
Purpose: This work introduces a new lattice geometry library, egs_lattice, into the EGSnrc Monte Carlo code, which can be used for both modeling very large (previously unfeasible) quantities of geometries and establishing recursive boundary conditions. The reliability of egs_lattice, as well as EGSnrc in general, is cross-validated and tested. Methods: New Bravais, cubic, and hexagonal lattice geometries are defined in egs_lattice and their transport algorithms are described. Simulations of cells and Gold NanoParticle (GNP) containing cavities are implemented to compare to published Geant4-DNA and PENELOPE results. Recursive boundary conditions, implemented through a cubic lattice, are used to perform electron Fano cavity tests. Results: Lattices are successfully implemented in EGSnrc. EGSnrc calculated doses to cell cytoplasm and nucleus when irradiated by an internal electron source with a median difference of 0.6% compared to Geant4-DNA. EGSnrc calculated the ratio of dose to a microscopic cavity containing GNPs over dose to a cavity containing a homogeneous mixture of gold, and results generally agree (within 1%) with PENELOPE. The Fano test is passed (sub-0.1%) for all energies/ cells considered. Additionally, the recursive boundary conditions used for the Fano test provided a factor of over a million increase in efficiency in some cases. Conclusions: The egs_lattice geometry library, currently available as a pull request on the EGSnrc GitHub develop branch, is now freely accessible as open-source code. Lattice geometry implementations cross-validated with independent simulations in other MC codes and verified with the electron Fano cavity test demonstrate not only the reliability of egs_lattice, but, by extension, EGSnrc's ability to simulate transport in nanometer geometries and score in microscopic cavities.
△ Less
Submitted 10 March, 2020;
originally announced March 2020.
-
Detector Technologies for CLIC
Authors:
A. C. Abusleme Hoffman,
G. Parès,
T. Fritzsch,
M. Rothermund,
H. Jansen,
K. Krüger,
F. Sefkow,
A. Velyka,
J. Schwandt,
I. Perić,
L. Emberger,
C. Graf,
A. Macchiolo,
F. Simon,
M. Szalay,
N. van der Kolk,
H. Abramowicz,
Y. Benhammou,
O. Borysov,
M. Borysova,
A. Joffe,
S. Kananov,
A. Levy,
I. Levy,
G. Eigen
, et al. (107 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Stan…
▽ More
The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Standard Model processes, particularly in the Higgs-boson and top-quark sectors. The precision required for such measurements and the specific conditions imposed by the beam dimensions and time structure put strict requirements on the detector design and technology. This includes low-mass vertexing and tracking systems with small cells, highly granular imaging calorimeters, as well as a precise hit-time resolution and power-pulsed operation for all subsystems. A conceptual design for the CLIC detector system was published in 2012. Since then, ambitious R&D programmes for silicon vertex and tracking detectors, as well as for calorimeters have been pursued within the CLICdp, CALICE and FCAL collaborations, addressing the challenging detector requirements with innovative technologies. This report introduces the experimental environment and detector requirements at CLIC and reviews the current status and future plans for detector technology R&D.
△ Less
Submitted 7 May, 2019;
originally announced May 2019.
-
Active Learning of Spin Network Models
Authors:
Jialong Jiang,
David A. Sivak,
Matt Thomson
Abstract:
The inverse statistical problem of finding direct interactions in complex networks is difficult. In the natural sciences, well-controlled perturbation experiments are widely used to probe the structure of complex networks. However, our understanding of how and why perturbations aid inference remains heuristic, and we lack automated procedures that determine network structure by combining inference…
▽ More
The inverse statistical problem of finding direct interactions in complex networks is difficult. In the natural sciences, well-controlled perturbation experiments are widely used to probe the structure of complex networks. However, our understanding of how and why perturbations aid inference remains heuristic, and we lack automated procedures that determine network structure by combining inference and perturbation. Therefore, we propose a general mathematical framework to study inference with iteratively applied perturbations. Using the formulation of information geometry, our framework quantifies the difficulty of inference and the information gain from perturbations through the curvature of the underlying parameter manifold, measured by Fisher information. We apply the framework to the inference of spin network models and find that designed perturbations can reduce the sampling complexity by $10^6$-fold across a variety of network architectures. Physically, our framework reveals that perturbations boost inference by causing a network to explore previously inaccessible states. Optimal perturbations break spin-spin correlations within a network, increasing the information available for inference and thus reducing sampling complexity by orders of magnitude. Our active learning framework could be powerful in the analysis of complex networks as well as in the rational design of experiments.
△ Less
Submitted 22 October, 2019; v1 submitted 25 March, 2019;
originally announced March 2019.
-
Research and Development for Near Detector Systems Towards Long Term Evolution of Ultra-precise Long-baseline Neutrino Experiments
Authors:
Aysel Kayis Topaksu,
Edward Blucher,
Bernard Andrieu,
Jianming Bian,
Byron Roe,
Glenn Horton-Smith,
Yoshinari Hayato,
Juan Antonio Caballero,
James Sinclair,
Yury Kudenko,
Laura Patrizi,
Luca Stanco,
Matteo Tenti,
Guilermo Daniel Megias,
Natalie Jachowicz,
Omar Benhar,
Giulia Ricciardi,
Stefan Roth,
Steven Manly,
Mario Stipcevi,
Davide Meloni,
Ignacio Ruiz,
Jan Sobczyk,
Luis Alvarez-Ruso,
Marco Martini
, et al. (89 additional authors not shown)
Abstract:
With the discovery of non-zero value of $θ_{13}$ mixing angle, the next generation of long-baseline neutrino (LBN) experiments offers the possibility of obtaining statistically significant samples of muon and electron neutrinos and anti-neutrinos with large oscillation effects. In this document we intend to highlight the importance of Near Detector facilities in LBN experiments to both constrain t…
▽ More
With the discovery of non-zero value of $θ_{13}$ mixing angle, the next generation of long-baseline neutrino (LBN) experiments offers the possibility of obtaining statistically significant samples of muon and electron neutrinos and anti-neutrinos with large oscillation effects. In this document we intend to highlight the importance of Near Detector facilities in LBN experiments to both constrain the systematic uncertainties affecting oscillation analyses but also to perform, thanks to their close location, measurements of broad benefit for LBN physics goals. A strong European contribution to these efforts is possible.
△ Less
Submitted 14 January, 2019;
originally announced January 2019.
-
Design and construction of the MicroBooNE Cosmic Ray Tagger system
Authors:
MicroBooNE collaboration,
C. Adams,
M. Alrashed,
R. An,
J. Anthony,
J. Asaadi,
A. Ashkenazi,
M. Auger,
S. Balasubramanian,
B. Baller,
C. Barnes,
G. Barr,
M. Bass,
F. Bay,
A. Bhat,
K. Bhattacharya,
M. Bishai,
A. Blake,
T. Bolton,
L. Camilleri,
D. Caratelli,
I. Caro Terrazas,
R. Carr,
R. Castillo Fernandez,
F. Cavanna
, et al. (149 additional authors not shown)
Abstract:
The MicroBooNE detector utilizes a liquid argon time projection chamber (LArTPC) with an 85 t active mass to study neutrino interactions along the Booster Neutrino Beam (BNB) at Fermilab. With a deployment location near ground level, the detector records many cosmic muon tracks in each beam-related detector trigger that can be misidentified as signals of interest. To reduce these cosmogenic backgr…
▽ More
The MicroBooNE detector utilizes a liquid argon time projection chamber (LArTPC) with an 85 t active mass to study neutrino interactions along the Booster Neutrino Beam (BNB) at Fermilab. With a deployment location near ground level, the detector records many cosmic muon tracks in each beam-related detector trigger that can be misidentified as signals of interest. To reduce these cosmogenic backgrounds, we have designed and constructed a TPC-external Cosmic Ray Tagger (CRT). This sub-system was developed by the Laboratory for High Energy Physics (LHEP), Albert Einstein center for fundamental physics, University of Bern. The system utilizes plastic scintillation modules to provide precise time and position information for TPC-traversing particles. Successful matching of TPC tracks and CRT data will allow us to reduce cosmogenic background and better characterize the light collection system and LArTPC data using cosmic muons. In this paper we describe the design and installation of the MicroBooNE CRT system and provide an overview of a series of tests done to verify the proper operation of the system and its components during installation, commissioning, and physics data-taking.
△ Less
Submitted 15 March, 2019; v1 submitted 9 January, 2019;
originally announced January 2019.
-
Controlling Organization and Forces in Active Matter Through Optically-Defined Boundaries
Authors:
Tyler D. Ross,
Heun ** Lee,
Zijie Qu,
Rachel A. Banks,
Rob Phillips,
Matt Thomson
Abstract:
Living systems are capable of locomotion, reconfiguration, and replication. To perform these tasks, cells spatiotemporally coordinate the interactions of force-generating, "active" molecules that create and manipulate non-equilibrium structures and force fields that span up to millimeter length scales [1-3]. Experimental active matter systems of biological or synthetic molecules are capable of spo…
▽ More
Living systems are capable of locomotion, reconfiguration, and replication. To perform these tasks, cells spatiotemporally coordinate the interactions of force-generating, "active" molecules that create and manipulate non-equilibrium structures and force fields that span up to millimeter length scales [1-3]. Experimental active matter systems of biological or synthetic molecules are capable of spontaneously organizing into structures [4,5] and generating global flows [6-9]. However, these experimental systems lack the spatiotemporal control found in cells, limiting their utility for studying non-equilibrium phenomena and bioinspired engineering. Here, we uncover non-equilibrium phenomena and principles by optically controlling structures and fluid flow in an engineered system of active biomolecules. Our engineered system consists of purified microtubules and light-activatable motor proteins that crosslink and organize microtubules into distinct structures upon illumination. We develop basic operations, defined as sets of light patterns, to create, move, and merge microtubule structures. By composing these basic operations, we are able to create microtubule networks that span several hundred microns in length and contract at speeds up to an order of magnitude faster than the speed of an individual motor. We manipulate these contractile networks to generate and sculpt persistent fluid flows. The principles of boundary-mediated control we uncover may be used to study emergent cellular structures and forces and to develop programmable active matter devices.
△ Less
Submitted 24 May, 2019; v1 submitted 21 December, 2018;
originally announced December 2018.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
Rejecting cosmic background for exclusive neutrino interaction studies with Liquid Argon TPCs; a case study with the MicroBooNE detector
Authors:
MicroBooNE collaboration,
C. Adams,
M. Alrashed,
R. An,
J. Anthony,
J. Asaadi,
A. Ashkenazi,
M. Auger,
S. Balasubramanian,
B. Baller,
C. Barnes,
G. Barr,
M. Bass,
F. Bay,
A. Bhat,
K. Bhattacharya,
M. Bishai,
A. Blake,
T. Bolton,
L. Camilleri,
D. Caratelli,
I. Caro Terrazas,
R. Carr,
R. Castillo Fernandez,
F. Cavanna
, et al. (150 additional authors not shown)
Abstract:
Cosmic ray (CR) interactions can be a challenging source of background for neutrino oscillation and cross-section measurements in surface detectors. We present methods for CR rejection in measurements of charged-current quasielastic-like (CCQE-like) neutrino interactions, with a muon and a proton in the final state, measured using liquid argon time projection chambers (LArTPCs). Using a sample of…
▽ More
Cosmic ray (CR) interactions can be a challenging source of background for neutrino oscillation and cross-section measurements in surface detectors. We present methods for CR rejection in measurements of charged-current quasielastic-like (CCQE-like) neutrino interactions, with a muon and a proton in the final state, measured using liquid argon time projection chambers (LArTPCs). Using a sample of cosmic data collected with the MicroBooNE detector, mixed with simulated neutrino scattering events, a set of event selection criteria is developed that produces an event sample with minimal contribution from CR background. Depending on the selection criteria used a purity between 50% and 80% can be achieved with a signal selection efficiency between 50% and 25%, with higher purity coming at the expense of lower efficiency. While using a specific dataset from the MicroBooNE detector and selection criteria values optimized for CCQE-like events, the concepts presented here are generic and can be adapted for various studies of exclusive νμ interactions in LArTPCs.
△ Less
Submitted 2 January, 2019; v1 submitted 9 December, 2018;
originally announced December 2018.
-
First Measurement of $ν_μ$ Charged-Current $π^{0}$ Production on Argon with a LArTPC
Authors:
MicroBooNE collaboration,
C. Adams,
M. Alrashed,
R. An,
J. Anthony,
J. Asaadi,
A. Ashkenazi,
M. Auger,
S. Balasubramanian,
B. Baller,
C. Barnes,
G. Barr,
M. Bass,
F. Bay,
A. Bhat,
K. Bhattacharya,
M. Bishai,
A. Blake,
T. Bolton,
L. Camilleri,
D. Caratelli,
I. Caro Terrazas,
R. Carr,
R. Castillo Fernandez,
F. Cavanna
, et al. (150 additional authors not shown)
Abstract:
We report the first measurement of the flux-integrated cross section of $ν_μ$ charged-current single $π^{0}$ production on argon. This measurement is performed with the MicroBooNE detector, an 85 ton active mass liquid argon time projection chamber exposed to the Booster Neutrino Beam at Fermilab. This result on argon is compared to past measurements on lighter nuclei to investigate the scaling as…
▽ More
We report the first measurement of the flux-integrated cross section of $ν_μ$ charged-current single $π^{0}$ production on argon. This measurement is performed with the MicroBooNE detector, an 85 ton active mass liquid argon time projection chamber exposed to the Booster Neutrino Beam at Fermilab. This result on argon is compared to past measurements on lighter nuclei to investigate the scaling assumptions used in models of the production and transport of pions in neutrino-nucleus scattering. The techniques used are an important demonstration of the successful reconstruction and analysis of neutrino interactions producing electromagnetic final states using a liquid argon time projection chamber operating at the earth's surface.
△ Less
Submitted 6 November, 2018;
originally announced November 2018.
-
A Deep Neural Network for Pixel-Level Electromagnetic Particle Identification in the MicroBooNE Liquid Argon Time Projection Chamber
Authors:
MicroBooNE collaboration,
C. Adams,
M. Alrashed,
R. An,
J. Anthony,
J. Asaadi,
A. Ashkenazi,
M. Auger,
S. Balasubramanian,
B. Baller,
C. Barnes,
G. Barr,
M. Bass,
F. Bay,
A. Bhat,
K. Bhattacharya,
M. Bishai,
A. Blake,
T. Bolton,
L. Camilleri,
D. Caratelli,
I. Caro Terrazas,
R. Carr,
R. Castillo Fernandez,
F. Cavanna
, et al. (148 additional authors not shown)
Abstract:
We have developed a convolutional neural network (CNN) that can make a pixel-level prediction of objects in image data recorded by a liquid argon time projection chamber (LArTPC) for the first time. We describe the network design, training techniques, and software tools developed to train this network. The goal of this work is to develop a complete deep neural network based data reconstruction cha…
▽ More
We have developed a convolutional neural network (CNN) that can make a pixel-level prediction of objects in image data recorded by a liquid argon time projection chamber (LArTPC) for the first time. We describe the network design, training techniques, and software tools developed to train this network. The goal of this work is to develop a complete deep neural network based data reconstruction chain for the MicroBooNE detector. We show the first demonstration of a network's validity on real LArTPC data using MicroBooNE collection plane images. The demonstration is performed for stop** muon and a $ν_μ$ charged current neutral pion data samples.
△ Less
Submitted 22 August, 2018;
originally announced August 2018.
-
Mathematical modelling of the vitamin C clock reaction
Authors:
R. Kerr,
W. M. Thomson,
D. J. Smith
Abstract:
Chemical clock reactions are characterised by a relatively long induction period followed by a rapid `switchover' during which the concentration of a \emph{clock chemical} rises rapidly. In addition to their interest in chemistry education, these reactions are relevant to industrial and biochemical applications. A substrate-depletive, non-autocatalytic clock reaction involving household chemicals…
▽ More
Chemical clock reactions are characterised by a relatively long induction period followed by a rapid `switchover' during which the concentration of a \emph{clock chemical} rises rapidly. In addition to their interest in chemistry education, these reactions are relevant to industrial and biochemical applications. A substrate-depletive, non-autocatalytic clock reaction involving household chemicals (vitamin C, iodine, hydrogen peroxide and starch) is modelled mathematically via a system of nonlinear ordinary differential equations. Following dimensional analysis the model is analysed in the phase plane and via matched asymptotic expansions. Asymptotic approximations are found to agree closely with numerical solutions in the appropriate time regions. Asymptotic analysis also yields an approximate formula for the dependence of switchover time on initial concentrations and the rate of the slow reaction. This formula is tested via `kitchen sink chemistry' experiments, and is found to enable a good fit to experimental series varying in initial concentrations of both iodine and vitamin C. The vitamin C clock reaction provides an accessible model system for mathematical chemistry.
△ Less
Submitted 24 March, 2019; v1 submitted 17 August, 2018;
originally announced August 2018.
-
Physically optimizing inference
Authors:
Audrey Huang,
Benjamin Sheldan,
David A. Sivak,
Matt Thomson
Abstract:
Data is scaling exponentially in fields ranging from genomics to neuroscience to economics. A central question is: can modern machine learning methods be applied to construct predictive models of natural systems like cells and brains based on large data sets? In this paper, we examine how inference is impacted when training data is generated by the statistical behavior of a physical system, and he…
▽ More
Data is scaling exponentially in fields ranging from genomics to neuroscience to economics. A central question is: can modern machine learning methods be applied to construct predictive models of natural systems like cells and brains based on large data sets? In this paper, we examine how inference is impacted when training data is generated by the statistical behavior of a physical system, and hence outside direct control by the experimentalist. We develop an information-theoretic analysis for the canonical problem of spin-network inference. Our analysis reveals the essential role that the physical properties of the spin network and its environment play in determining the difficulty of the underlying machine learning problem. Specifically, stochastic fluctuations drive a system to explore a range of configurations providing `raw' information for a learning algorithm to construct an accurate model; yet they also blur energetic differences between network states and thereby degrade information. This competition leads spin networks to generically have an intrinsic optimal temperature at which stochastic spin fluctuations provide maximal information for discriminating among competing models, maximizing inference efficiency. We demonstrate a simple active learning protocol that optimizes network temperature to boost inference efficiency and dramatically increases the efficiency of inference on a neural circuit reconstruction task. Our results reveal a fundamental link between physics and information and show how the physical environment can be tuned to optimize the efficiency of machine learning.
△ Less
Submitted 16 August, 2018; v1 submitted 19 May, 2018;
originally announced May 2018.
-
Comparison of νμ-Ar multiplicity distributions observed by MicroBooNE to GENIE model predictions
Authors:
C. Adams,
R. An,
J. Anthony,
J. Asaadi,
M. Auger,
S. Balasubramanian,
B. Baller,
C. Barnes,
G. Barr,
M. Bass,
F. Bay,
A. Bhat,
K. Bhattacharya,
M. Bishai,
A. Blake,
T. Bolton,
L. Camilleri,
D. Caratelli,
R. Castillo Fernandez,
F. Cavanna,
G. Cerati,
H. Chen,
Y. Chen,
E. Church,
D. Cianci
, et al. (140 additional authors not shown)
Abstract:
We measure a large set of observables in inclusive charged current muon neutrino scattering on argon with the MicroBooNE liquid argon time projection chamber operating at Fermilab. We evaluate three neutrino interaction models based on the widely used GENIE event generator using these observables. The measurement uses a data set consisting of neutrino interactions with a final state muon candidate…
▽ More
We measure a large set of observables in inclusive charged current muon neutrino scattering on argon with the MicroBooNE liquid argon time projection chamber operating at Fermilab. We evaluate three neutrino interaction models based on the widely used GENIE event generator using these observables. The measurement uses a data set consisting of neutrino interactions with a final state muon candidate fully contained within the MicroBooNE detector. These data were collected in 2016 with the Fermilab Booster Neutrino Beam, which has an average neutrino energy of 800 MeV, using an exposure corresponding to 5E19 protons-on-target. The analysis employs fully automatic event selection and charged particle track reconstruction and uses a data-driven technique to separate neutrino interactions from cosmic ray background events. We find that GENIE models consistently describe the shapes of a large number of kinematic distributions for fixed observed multiplicity.
△ Less
Submitted 26 March, 2019; v1 submitted 17 May, 2018;
originally announced May 2018.
-
Ionization Electron Signal Processing in Single Phase LArTPCs II. Data/Simulation Comparison and Performance in MicroBooNE
Authors:
MicroBooNE collaboration,
C. Adams,
R. An,
J. Anthony,
J. Asaadi,
M. Auger,
S. Balasubramanian,
B. Baller,
C. Barnes,
G. Barr,
M. Bass,
F. Bay,
A. Bhat,
K. Bhattacharya,
M. Bishai,
A. Blake,
T. Bolton,
L. Camilleri,
D. Caratelli,
R. Carr,
I. Caro Terrazas,
R. Castillo Fernandez,
F. Cavanna,
G. Cerati,
H. Chen
, et al. (146 additional authors not shown)
Abstract:
The single-phase liquid argon time projection chamber (LArTPC) provides a large amount of detailed information in the form of fine-grained drifted ionization charge from particle traces. To fully utilize this information, the deposited charge must be accurately extracted from the raw digitized waveforms via a robust signal processing chain. Enabled by the ultra-low noise levels associated with cry…
▽ More
The single-phase liquid argon time projection chamber (LArTPC) provides a large amount of detailed information in the form of fine-grained drifted ionization charge from particle traces. To fully utilize this information, the deposited charge must be accurately extracted from the raw digitized waveforms via a robust signal processing chain. Enabled by the ultra-low noise levels associated with cryogenic electronics in the MicroBooNE detector, the precise extraction of ionization charge from the induction wire planes in a single-phase LArTPC is qualitatively demonstrated on MicroBooNE data with event display images, and quantitatively demonstrated via waveform-level and track-level metrics. Improved performance of induction plane calorimetry is demonstrated through the agreement of extracted ionization charge measurements across different wire planes for various event topologies. In addition to the comprehensive waveform-level comparison of data and simulation, a calibration of the cryogenic electronics response is presented and solutions to various MicroBooNE-specific TPC issues are discussed. This work presents an important improvement in LArTPC signal processing, the foundation of reconstruction and therefore physics analyses in MicroBooNE.
△ Less
Submitted 11 June, 2018; v1 submitted 7 April, 2018;
originally announced April 2018.
-
Ionization Electron Signal Processing in Single Phase LArTPCs I. Algorithm Description and Quantitative Evaluation with MicroBooNE Simulation
Authors:
MicroBooNE collaboration,
C. Adams,
R. An,
J. Anthony,
J. Asaadi,
M. Auger,
L. Bagby,
S. Balasubramanian,
B. Baller,
C. Barnes,
G. Barr,
M. Bass,
F. Bay,
A. Bhat,
K. Bhattacharya,
M. Bishai,
A. Blake,
T. Bolton,
L. Camilleri,
D. Caratelli,
R. Castillo Fernandez,
F. Cavanna,
G. Cerati,
H. Chen,
Y. Chen
, et al. (144 additional authors not shown)
Abstract:
We describe the concept and procedure of drifted-charge extraction developed in the MicroBooNE experiment, a single-phase liquid argon time projection chamber (LArTPC). This technique converts the raw digitized TPC waveform to the number of ionization electrons passing through a wire plane at a given time. A robust recovery of the number of ionization electrons from both induction and collection a…
▽ More
We describe the concept and procedure of drifted-charge extraction developed in the MicroBooNE experiment, a single-phase liquid argon time projection chamber (LArTPC). This technique converts the raw digitized TPC waveform to the number of ionization electrons passing through a wire plane at a given time. A robust recovery of the number of ionization electrons from both induction and collection anode wire planes will augment the 3D reconstruction, and is particularly important for tomographic reconstruction algorithms. A number of building blocks of the overall procedure are described. The performance of the signal processing is quantitatively evaluated by comparing extracted charge with the true charge through a detailed TPC detector simulation taking into account position-dependent induced current inside a single wire region and across multiple wires. Some areas for further improvement of the performance of the charge extraction procedure are also discussed.
△ Less
Submitted 9 April, 2018; v1 submitted 23 February, 2018;
originally announced February 2018.
-
The Pandora multi-algorithm approach to automated pattern recognition of cosmic-ray muon and neutrino events in the MicroBooNE detector
Authors:
MicroBooNE collaboration,
R. Acciarri,
C. Adams,
R. An,
J. Anthony,
J. Asaadi,
M. Auger,
L. Bagby,
S. Balasubramanian,
B. Baller,
C. Barnes,
G. Barr,
M. Bass,
F. Bay,
M. Bishai,
A. Blake,
T. Bolton,
L. Camilleri,
D. Caratelli,
B. Carls,
R. Castillo Fernandez,
F. Cavanna,
H. Chen,
E. Church,
D. Cianci
, et al. (123 additional authors not shown)
Abstract:
The development and operation of Liquid-Argon Time-Projection Chambers for neutrino physics has created a need for new approaches to pattern recognition in order to fully exploit the imaging capabilities offered by this technology. Whereas the human brain can excel at identifying features in the recorded events, it is a significant challenge to develop an automated, algorithmic solution. The Pando…
▽ More
The development and operation of Liquid-Argon Time-Projection Chambers for neutrino physics has created a need for new approaches to pattern recognition in order to fully exploit the imaging capabilities offered by this technology. Whereas the human brain can excel at identifying features in the recorded events, it is a significant challenge to develop an automated, algorithmic solution. The Pandora Software Development Kit provides functionality to aid the design and implementation of pattern-recognition algorithms. It promotes the use of a multi-algorithm approach to pattern recognition, in which individual algorithms each address a specific task in a particular topology. Many tens of algorithms then carefully build up a picture of the event and, together, provide a robust automated pattern-recognition solution. This paper describes details of the chain of over one hundred Pandora algorithms and tools used to reconstruct cosmic-ray muon and neutrino events in the MicroBooNE detector. Metrics that assess the current pattern-recognition performance are presented for simulated MicroBooNE events, using a selection of final-state event topologies.
△ Less
Submitted 10 August, 2017;
originally announced August 2017.
-
Construction and Response of a Highly Granular Scintillator-based Electromagnetic Calorimeter
Authors:
CALICE collaboration,
J. Repond,
L. Xia,
G. Eigen,
T. Price,
N. K. Watson,
A. Winter,
M. A. Thomson,
G. C. Blazey,
A. Dyshkant,
K. Francis,
V. Zutshi,
K. Gadow,
P. Göttlicher,
O. Hartbrich,
F. Krivan,
K. Krüger,
S. Lu,
B. Lutz,
M. Reinecke,
F. Sefkow,
Y. Sudo,
H. L. Tran,
A. Kaplan,
H. -Ch. Schultz-Coulon
, et al. (57 additional authors not shown)
Abstract:
A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future lepton collider experiments. A prototype of 21.5 $X_0$ depth and $180 \times 180 $mm$^2$ transverse dimensions was constructed, consisting of 2160 individually read out $10 \times 45 \times 3$ mm$^3$ scintillator strips. This prototype was tested using electrons of 2--32 GeV at the Fermilab…
▽ More
A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future lepton collider experiments. A prototype of 21.5 $X_0$ depth and $180 \times 180 $mm$^2$ transverse dimensions was constructed, consisting of 2160 individually read out $10 \times 45 \times 3$ mm$^3$ scintillator strips. This prototype was tested using electrons of 2--32 GeV at the Fermilab Test Beam Facility in 2009. Deviations from linear energy response were less than 1.1\%, and the intrinsic energy resolution was determined to be $(12.5 \pm 0.1 (\mathrm{stat.}) \pm0.4 (\mathrm{syst.}))\%/\sqrt{E[\mathrm{GeV}]}\oplus (1.2 \pm 0.1(\mathrm{stat.})^{+0.6}_{-0.7}(\mathrm{syst.}))\%$, where the uncertainties correspond to statistical and systematic sources, respectively.
△ Less
Submitted 28 February, 2018; v1 submitted 22 July, 2017;
originally announced July 2017.
-
The Single-Phase ProtoDUNE Technical Design Report
Authors:
B. Abi,
R. Acciarri,
M. A. Acero,
M. Adamowski,
C. Adams,
D. L. Adams,
P. Adamson,
M. Adinolfi,
Z. Ahmad,
C. H. Albright,
T. Alion,
J. Anderson,
K. Anderson,
C. Andreopoulos,
M. P. Andrews,
R. A. Andrews,
J. dos Anjos,
A. Ankowski,
J. Anthony,
M. Antonello,
A. Aranda Fernandez,
A. Ariga,
T. Ariga,
E. Arrieta Diaz,
J. Asaadi
, et al. (806 additional authors not shown)
Abstract:
ProtoDUNE-SP is the single-phase DUNE Far Detector prototype that is under construction and will be operated at the CERN Neutrino Platform (NP) starting in 2018. ProtoDUNE-SP, a crucial part of the DUNE effort towards the construction of the first DUNE 10-kt fiducial mass far detector module (17 kt total LAr mass), is a significant experiment in its own right. With a total liquid argon (LAr) mass…
▽ More
ProtoDUNE-SP is the single-phase DUNE Far Detector prototype that is under construction and will be operated at the CERN Neutrino Platform (NP) starting in 2018. ProtoDUNE-SP, a crucial part of the DUNE effort towards the construction of the first DUNE 10-kt fiducial mass far detector module (17 kt total LAr mass), is a significant experiment in its own right. With a total liquid argon (LAr) mass of 0.77 kt, it represents the largest monolithic single-phase LArTPC detector to be built to date. It's technical design is given in this report.
△ Less
Submitted 27 July, 2017; v1 submitted 21 June, 2017;
originally announced June 2017.
-
Software compensation in Particle Flow reconstruction
Authors:
Huong Lan Tran,
Katja Krüger,
Felix Sefkow,
Steven Green,
John Marshall,
Mark Thomson,
Frank Simon
Abstract:
The particle flow approach to calorimetry benefits from highly granular calorimeters and sophisticated software algorithms in order to reconstruct and identify individual particles in complex event topologies. The high spatial granularity, together with analogue energy information, can be further exploited in software compensation. In this approach, the local energy density is used to discriminate…
▽ More
The particle flow approach to calorimetry benefits from highly granular calorimeters and sophisticated software algorithms in order to reconstruct and identify individual particles in complex event topologies. The high spatial granularity, together with analogue energy information, can be further exploited in software compensation. In this approach, the local energy density is used to discriminate electromagnetic and purely hadronic sub-showers within hadron showers in the detector to improve the energy resolution for single particles by correcting for the intrinsic non-compensation of the calorimeter system. This improvement in the single particle energy resolution also results in a better overall jet energy resolution by improving the energy measurement of identified neutral hadrons and improvements in the pattern recognition stage by a more accurate matching of calorimeter energies to tracker measurements. This paper describes the software compensation technique and its implementation in particle flow reconstruction with the Pandora Particle Flow Algorithm (PandoraPFA). The impact of software compensation on the choice of optimal transverse granularity for the analogue hadronic calorimeter option of the International Large Detector (ILD) concept is also discussed.
△ Less
Submitted 25 October, 2017; v1 submitted 29 May, 2017;
originally announced May 2017.
-
Noise Characterization and Filtering in the MicroBooNE Liquid Argon TPC
Authors:
MicroBooNE collaboration,
R. Acciarri,
C. Adams,
R. An,
J. Anthony,
J. Asaadi,
M. Auger,
L. Bagby,
S. Balasubramanian,
B. Baller,
C. Barnes,
G. Barr,
M. Bass,
F. Bay,
M. Bishai,
A. Blake,
T. Bolton,
B. Bullard,
L. Camilleri,
D. Caratelli,
B. Carls,
R. Castillo Fernandez,
F. Cavanna,
H. Chen,
E. Church
, et al. (130 additional authors not shown)
Abstract:
The low-noise operation of readout electronics in a liquid argon time projection chamber (LArTPC) is critical to properly extract the distribution of ionization charge deposited on the wire planes of the TPC, especially for the induction planes. This paper describes the characteristics and mitigation of the observed noise in the MicroBooNE detector. The MicroBooNE's single-phase LArTPC comprises t…
▽ More
The low-noise operation of readout electronics in a liquid argon time projection chamber (LArTPC) is critical to properly extract the distribution of ionization charge deposited on the wire planes of the TPC, especially for the induction planes. This paper describes the characteristics and mitigation of the observed noise in the MicroBooNE detector. The MicroBooNE's single-phase LArTPC comprises two induction planes and one collection sense wire plane with a total of 8256 wires. Current induced on each TPC wire is amplified and shaped by custom low-power, low-noise ASICs immersed in the liquid argon. The digitization of the signal waveform occurs outside the cryostat. Using data from the first year of MicroBooNE operations, several excess noise sources in the TPC were identified and mitigated. The residual equivalent noise charge (ENC) after noise filtering varies with wire length and is found to be below 400 electrons for the longest wires (4.7 m). The response is consistent with the cold electronics design expectations and is found to be stable with time and uniform over the functioning channels. This noise level is significantly lower than previous experiments utilizing warm front-end electronics.
△ Less
Submitted 20 May, 2017;
originally announced May 2017.
-
Michel Electron Reconstruction Using Cosmic-Ray Data from the MicroBooNE LArTPC
Authors:
MicroBooNE collaboration,
R. Acciarri,
C. Adams,
R. An,
J. Anthony,
J. Asaadi,
M. Auger,
L. Bagby,
S. Balasubramanian,
B. Baller,
C. Barnes,
G. Barr,
M. Bass,
F. Bay,
M. Bishai,
A. Blake,
T. Bolton,
L. Bugel,
L. Camilleri,
D. Caratelli,
B. Carls,
R. Castillo Fernandez,
F. Cavanna,
H. Chen,
E. Church
, et al. (121 additional authors not shown)
Abstract:
The MicroBooNE liquid argon time projection chamber (LArTPC) has been taking data at Fermilab since 2015 collecting, in addition to neutrino beam, cosmic-ray muons. Results are presented on the reconstruction of Michel electrons produced by the decay at rest of cosmic-ray muons. Michel electrons are abundantly produced in the TPC, and given their well known energy spectrum can be used to study Mic…
▽ More
The MicroBooNE liquid argon time projection chamber (LArTPC) has been taking data at Fermilab since 2015 collecting, in addition to neutrino beam, cosmic-ray muons. Results are presented on the reconstruction of Michel electrons produced by the decay at rest of cosmic-ray muons. Michel electrons are abundantly produced in the TPC, and given their well known energy spectrum can be used to study MicroBooNE's detector response to low-energy electrons (electrons with energies up to ~50 MeV). We describe the fully-automated algorithm developed to reconstruct Michel electrons, with which a sample of ~14,000 Michel electron candidates is obtained. Most of this article is dedicated to studying the impact of radiative photons produced by Michel electrons on the accuracy and resolution of their energy measurement. In this energy range, ionization and bremsstrahlung photon production contribute similarly to electron energy loss in argon, leading to a complex electron topology in the TPC. By profiling the performance of the reconstruction algorithm on simulation we show that the ability to identify and include energy deposited by radiative photons leads to a significant improvement in the energy measurement of low-energy electrons. The fractional energy resolution we measure improves from over 30% to ~20% when we attempt to include radiative photons in the reconstruction. These studies are relevant to a large number of analyses which aim to study neutrinos by measuring electrons produced by $ν_e$ interactions over a broad energy range.
△ Less
Submitted 30 August, 2017; v1 submitted 10 April, 2017;
originally announced April 2017.
-
Determination of muon momentum in the MicroBooNE LArTPC using an improved model of multiple Coulomb scattering
Authors:
MicroBooNE collaboration,
P. Abratenko,
R. Acciarri,
C. Adams,
R. An,
J. Asaadi,
M. Auger,
L. Bagby,
S. Balasubramanian,
B. Baller,
C. Barnes,
G. Barr,
M. Bass,
F. Bay,
M. Bishai,
A. Blake,
T. Bolton,
L. Bugel,
L. Camilleri,
D. Caratelli,
B. Carls,
R. Castillo Fernandez,
F. Cavanna,
H. Chen,
E. Church
, et al. (123 additional authors not shown)
Abstract:
We discuss a technique for measuring a charged particle's momentum by means of multiple Coulomb scattering (MCS) in the MicroBooNE liquid argon time projection chamber (LArTPC). This method does not require the full particle ionization track to be contained inside of the detector volume as other track momentum reconstruction methods do (range-based momentum reconstruction and calorimetric momentum…
▽ More
We discuss a technique for measuring a charged particle's momentum by means of multiple Coulomb scattering (MCS) in the MicroBooNE liquid argon time projection chamber (LArTPC). This method does not require the full particle ionization track to be contained inside of the detector volume as other track momentum reconstruction methods do (range-based momentum reconstruction and calorimetric momentum reconstruction). We motivate use of this technique, describe a tuning of the underlying phenomenological formula, quantify its performance on fully contained beam-neutrino-induced muon tracks both in simulation and in data, and quantify its performance on exiting muon tracks in simulation. Using simulation, we have shown that the standard Highland formula should be re-tuned specifically for scattering in liquid argon, which significantly improves the bias and resolution of the momentum measurement. With the tuned formula, we find agreement between data and simulation for contained tracks, with a small bias in the momentum reconstruction and with resolutions that vary as a function of track length, improving from about 10% for the shortest (one meter long) tracks to 5% for longer (several meter) tracks. For simulated exiting muons with at least one meter of track contained, we find a similarly small bias, and a resolution which is less than 15% for muons with momentum below 2 GeV/c. Above 2 GeV/c, results are given as a first estimate of the MCS momentum measurement capabilities of MicroBooNE for high momentum exiting tracks.
△ Less
Submitted 5 October, 2017; v1 submitted 17 March, 2017;
originally announced March 2017.
-
Design and Construction of the MicroBooNE Detector
Authors:
MicroBooNE Collaboration,
R. Acciarri,
C. Adams,
R. An,
A. Aparicio,
S. Aponte,
J. Asaadi,
M. Auger,
N. Ayoub,
L. Bagby,
B. Baller,
R. Barger,
G. Barr,
M. Bass,
F. Bay,
K. Biery,
M. Bishai,
A. Blake,
V. Bocean,
D. Boehnlein,
V. D. Bogert,
T. Bolton,
L. Bugel,
C. Callahan,
L. Camilleri
, et al. (215 additional authors not shown)
Abstract:
This paper describes the design and construction of the MicroBooNE liquid argon time projection chamber and associated systems. MicroBooNE is the first phase of the Short Baseline Neutrino program, located at Fermilab, and will utilize the capabilities of liquid argon detectors to examine a rich assortment of physics topics. In this document details of design specifications, assembly procedures, a…
▽ More
This paper describes the design and construction of the MicroBooNE liquid argon time projection chamber and associated systems. MicroBooNE is the first phase of the Short Baseline Neutrino program, located at Fermilab, and will utilize the capabilities of liquid argon detectors to examine a rich assortment of physics topics. In this document details of design specifications, assembly procedures, and acceptance tests are reported.
△ Less
Submitted 17 January, 2017; v1 submitted 17 December, 2016;
originally announced December 2016.
-
Convolutional Neural Networks Applied to Neutrino Events in a Liquid Argon Time Projection Chamber
Authors:
MicroBooNE collaboration,
R. Acciarri,
C. Adams,
R. An,
J. Asaadi,
M. Auger,
L. Bagby,
B. Baller,
G. Barr,
M. Bass,
F. Bay,
M. Bishai,
A. Blake,
T. Bolton,
L. Bugel,
L. Camilleri,
D. Caratelli,
B. Carls,
R. Castillo Fernandez,
F. Cavanna,
H. Chen,
E. Church,
D. Cianci,
G. H. Collin,
J. M. Conrad
, et al. (114 additional authors not shown)
Abstract:
We present several studies of convolutional neural networks applied to data coming from the MicroBooNE detector, a liquid argon time projection chamber (LArTPC). The algorithms studied include the classification of single particle images, the localization of single particle and neutrino interactions in an image, and the detection of a simulated neutrino event overlaid with cosmic ray backgrounds t…
▽ More
We present several studies of convolutional neural networks applied to data coming from the MicroBooNE detector, a liquid argon time projection chamber (LArTPC). The algorithms studied include the classification of single particle images, the localization of single particle and neutrino interactions in an image, and the detection of a simulated neutrino event overlaid with cosmic ray backgrounds taken from real detector data. These studies demonstrate the potential of convolutional neural networks for particle identification or event detection on simulated neutrino interactions. We also address technical issues that arise when applying this technique to data from a large LArTPC at or near ground level.
△ Less
Submitted 16 November, 2016;
originally announced November 2016.
-
Updated baseline for a staged Compact Linear Collider
Authors:
The CLIC,
CLICdp collaborations,
:,
M. J. Boland,
U. Felzmann,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
C. Balazs,
T. K. Charles,
K. Afanaciev,
I. Emeliantchik,
A. Ignatenko,
V. Makarenko,
N. Shumeiko,
A. Patapenka,
I. Zhuk,
A. C. Abusleme Hoffman,
M. A. Diaz Gutierrez,
M. Vogel Gonzalez,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu
, et al. (493 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-q…
▽ More
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of centre-of-mass energy and it targets optimal physics output based on the current physics landscape. The optimised staging scenario foresees three main centre-of-mass energy stages at 380 GeV, 1.5 TeV and 3 TeV for a full CLIC programme spanning 22 years. For the first stage, an alternative to the CLIC drive beam scheme is presented in which the main linac power is produced using X-band klystrons.
△ Less
Submitted 27 March, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
Hadron shower decomposition in the highly granular CALICE analogue hadron calorimeter
Authors:
The CALICE Collaboration,
G. Eigen,
T. Price,
N. K. Watson,
J. S. Marshall,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
J. Apostolakis,
A. Dotti,
G. Folger,
V. Ivantchenko,
A. Ribon,
V. Uzhinskiy,
J. -Y. Hostachy,
L. Morin,
E. Brianne,
A. Ebrahimi,
K. Gadow,
P. Göttlicher,
C. Günter,
O. Hartbrich,
B. Hermberg
, et al. (135 additional authors not shown)
Abstract:
The spatial development of hadronic showers in the CALICE scintillator-steel analogue hadron calorimeter is studied using test beam data collected at CERN and FNAL for single positive pions and protons with initial momenta in the range from 10 to 80 GeV/c. Both longitudinal and radial development of hadron showers are parametrised with two-component functions. The parametrisation is fit to test be…
▽ More
The spatial development of hadronic showers in the CALICE scintillator-steel analogue hadron calorimeter is studied using test beam data collected at CERN and FNAL for single positive pions and protons with initial momenta in the range from 10 to 80 GeV/c. Both longitudinal and radial development of hadron showers are parametrised with two-component functions. The parametrisation is fit to test beam data and simulations using the QGSP_BERT and FTFP_BERT physics lists from Geant4 version 9.6. The parameters extracted from data and simulated samples are compared for the two types of hadrons. The response to pions and the ratio of the non-electromagnetic to the electromagnetic calorimeter response, h/e, are estimated using the extrapolation and decomposition of the longitudinal profiles.
△ Less
Submitted 15 March, 2016; v1 submitted 27 February, 2016;
originally announced February 2016.
-
Measurement of the Multiple-Muon Charge Ratio in the MINOS Far Detector
Authors:
Minos Collaboration,
P. Adamson,
I. Anghel,
A. Aurisano,
G. Barr,
M. Bishai,
A. Blake,
G. J. Bock,
D. Bogert,
S. V. Cao,
T. J. Carroll,
C. M. Castromonte,
R. Chen,
S. Childress,
J. A. B. Coelho,
L. Corwin,
D. Cronin-Hennessy,
J. K. de Jong,
S. De Rijck,
A. V. Devan,
N. E. Devenish,
M. V. Diwan,
C. O. Escobar,
J. J. Evans,
E. Falk
, et al. (96 additional authors not shown)
Abstract:
The charge ratio, $R_μ= N_{μ^+}/N_{μ^-}$, for cosmogenic multiple-muon events observed at an under- ground depth of 2070 mwe has been measured using the magnetized MINOS Far Detector. The multiple-muon events, recorded nearly continuously from August 2003 until April 2012, comprise two independent data sets imaged with opposite magnetic field polarities, the comparison of which allows the systemat…
▽ More
The charge ratio, $R_μ= N_{μ^+}/N_{μ^-}$, for cosmogenic multiple-muon events observed at an under- ground depth of 2070 mwe has been measured using the magnetized MINOS Far Detector. The multiple-muon events, recorded nearly continuously from August 2003 until April 2012, comprise two independent data sets imaged with opposite magnetic field polarities, the comparison of which allows the systematic uncertainties of the measurement to be minimized. The multiple-muon charge ratio is determined to be $R_μ= 1.104 \pm 0.006 {\rm \,(stat.)} ^{+0.009}_{-0.010} {\rm \,(syst.)} $. This measurement complements previous determinations of single-muon and multiple-muon charge ratios at underground sites and serves to constrain models of cosmic ray interactions at TeV energies.
△ Less
Submitted 24 March, 2016; v1 submitted 1 February, 2016;
originally announced February 2016.
-
Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) Conceptual Design Report Volume 1: The LBNF and DUNE Projects
Authors:
R. Acciarri,
M. A. Acero,
M. Adamowski,
C. Adams,
P. Adamson,
S. Adhikari,
Z. Ahmad,
C. H. Albright,
T. Alion,
E. Amador,
J. Anderson,
K. Anderson,
C. Andreopoulos,
M. Andrews,
R. Andrews,
I. Anghel,
J. d. Anjos,
A. Ankowski,
M. Antonello,
A. ArandaFernandez,
A. Ariga,
T. Ariga,
D. Aristizabal,
E. Arrieta-Diaz,
K. Aryal
, et al. (780 additional authors not shown)
Abstract:
This document presents the Conceptual Design Report (CDR) put forward by an international neutrino community to pursue the Deep Underground Neutrino Experiment at the Long-Baseline Neutrino Facility (LBNF/DUNE), a groundbreaking science experiment for long-baseline neutrino oscillation studies and for neutrino astrophysics and nucleon decay searches. The DUNE far detector will be a very large modu…
▽ More
This document presents the Conceptual Design Report (CDR) put forward by an international neutrino community to pursue the Deep Underground Neutrino Experiment at the Long-Baseline Neutrino Facility (LBNF/DUNE), a groundbreaking science experiment for long-baseline neutrino oscillation studies and for neutrino astrophysics and nucleon decay searches. The DUNE far detector will be a very large modular liquid argon time-projection chamber (LArTPC) located deep underground, coupled to the LBNF multi-megawatt wide-band neutrino beam. DUNE will also have a high-resolution and high-precision near detector.
△ Less
Submitted 20 January, 2016;
originally announced January 2016.
-
Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) Conceptual Design Report, Volume 4 The DUNE Detectors at LBNF
Authors:
R. Acciarri,
M. A. Acero,
M. Adamowski,
C. Adams,
P. Adamson,
S. Adhikari,
Z. Ahmad,
C. H. Albright,
T. Alion,
E. Amador,
J. Anderson,
K. Anderson,
C. Andreopoulos,
M. Andrews,
R. Andrews,
I. Anghel,
J. d. Anjos,
A. Ankowski,
M. Antonello,
A. ArandaFernandez,
A. Ariga,
T. Ariga,
D. Aristizabal,
E. Arrieta-Diaz,
K. Aryal
, et al. (779 additional authors not shown)
Abstract:
A description of the proposed detector(s) for DUNE at LBNF
A description of the proposed detector(s) for DUNE at LBNF
△ Less
Submitted 12 January, 2016;
originally announced January 2016.
-
Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) Conceptual Design Report Volume 2: The Physics Program for DUNE at LBNF
Authors:
DUNE Collaboration,
R. Acciarri,
M. A. Acero,
M. Adamowski,
C. Adams,
P. Adamson,
S. Adhikari,
Z. Ahmad,
C. H. Albright,
T. Alion,
E. Amador,
J. Anderson,
K. Anderson,
C. Andreopoulos,
M. Andrews,
R. Andrews,
I. Anghel,
J. d. Anjos,
A. Ankowski,
M. Antonello,
A. ArandaFernandez,
A. Ariga,
T. Ariga,
D. Aristizabal,
E. Arrieta-Diaz
, et al. (780 additional authors not shown)
Abstract:
The Physics Program for the Deep Underground Neutrino Experiment (DUNE) at the Fermilab Long-Baseline Neutrino Facility (LBNF) is described.
The Physics Program for the Deep Underground Neutrino Experiment (DUNE) at the Fermilab Long-Baseline Neutrino Facility (LBNF) is described.
△ Less
Submitted 22 January, 2016; v1 submitted 18 December, 2015;
originally announced December 2015.