-
Microscopic-scale recording of brain neuronal electrical activity using a diamond quantum sensor
Authors:
Nikolaj Winther Hansen,
James Luke Webb,
Luca Troise,
Christoffer Olsson,
Leo Tomasevic,
Ovidiu Brinza,
Jocelyn Achard,
Robert Staacke,
Michael Kieschnick,
Jan Meijer,
Axel Thielscher,
Hartwig Roman Siebner,
Kirstine Berg-Sørensen,
Jean-François Perrier,
Alexander Huck,
Ulrik Lund Andersen
Abstract:
An important tool in the investigation of the early stages of neurodegenerative disease is the study of dissected living tissue from the brain of an animal model. Such investigations allow the physical structure of individual neurons and neural circuits to be probed alongside neuronal electrical activity, disruption of which can shed light on the mechanisms of emergence of disease. Existing techni…
▽ More
An important tool in the investigation of the early stages of neurodegenerative disease is the study of dissected living tissue from the brain of an animal model. Such investigations allow the physical structure of individual neurons and neural circuits to be probed alongside neuronal electrical activity, disruption of which can shed light on the mechanisms of emergence of disease. Existing techniques for recording activity rely on potentially damaging direct interaction with the sample, either mechanically as point electrical probes or via intense focused laser light combined with highly specific genetic modification and/or potentially toxic fluorescent dyes. In this work, we instead perform passive, microscopic-scale recording of electrical activity using a biocompatible quantum sensor based on colour centres in diamond. We record biomagnetic field induced by ionic currents in mouse corpus callosum axons without direct sample interaction, accurately recovering signals corresponding to action potential propagation while demonstrating in situ pharmacology during biomagnetic recording through tetrodotoxin inhibition of voltage gated sodium channels. Our results open a promising new avenue for the microscopic recording of neuronal signals, offering the prospect of high resolution imaging of electrical circuits in the living mammalian brain.
△ Less
Submitted 30 August, 2022;
originally announced August 2022.
-
Benchmark problems for transcranial ultrasound simulation: Intercomparison of compressional wave models
Authors:
Jean-Francois Aubry,
Oscar Bates,
Christian Boehm,
Kim Butts Pauly,
Douglas Christensen,
Carlos Cueto,
Pierre Gelat,
Lluis Guasch,
Jiri Jaros,
Yun **g,
Rebecca Jones,
Ningrui Li,
Patrick Marty,
Hazael Montanaro,
Esra Neufeld,
Samuel Pichardo,
Gianmarco Pinton,
Aki Pulkkinen,
Antonio Stanziola,
Axel Thielscher,
Bradley Treeby,
Elwin van 't Wout
Abstract:
Computational models of acoustic wave propagation are frequently used in transcranial ultrasound therapy, for example, to calculate the intracranial pressure field or to calculate phase delays to correct for skull distortions. To allow intercomparison between the different modeling tools and techniques used by the community, an international working group was convened to formulate a set of numeric…
▽ More
Computational models of acoustic wave propagation are frequently used in transcranial ultrasound therapy, for example, to calculate the intracranial pressure field or to calculate phase delays to correct for skull distortions. To allow intercomparison between the different modeling tools and techniques used by the community, an international working group was convened to formulate a set of numerical benchmarks. Here, these benchmarks are presented, along with intercomparison results. Nine different benchmarks of increasing geometric complexity are defined. These include a single-layer planar bone immersed in water, a multi-layer bone, and a whole skull. Two transducer configurations are considered (a focused bowl and a plane piston), giving a total of 18 permutations of the benchmarks. Eleven different modeling tools are used to compute the benchmark results. The models span a wide range of numerical techniques, including the finite-difference time-domain method, angular-spectrum method, pseudospectral method, boundary-element method, and spectral-element method. Good agreement is found between the models, particularly for the position, size, and magnitude of the acoustic focus within the skull. When comparing results for each model with every other model in a cross comparison, the median values for each benchmark for the difference in focal pressure and position are less than 10\% and 1 mm, respectively. The benchmark definitions, model results, and intercomparison codes are freely available to facilitate further comparisons.
△ Less
Submitted 9 February, 2022;
originally announced February 2022.
-
Laser stimulation of muscle activity with simultaneous detection using a diamond colour centre biosensor
Authors:
Luca Troise,
Nikolaj Winther Hansen,
Christoffer Olsson,
James Luke Webb,
Leo Tomasevic,
Jocelyn Achard,
Ovidiu Brinza,
Robert Staacke,
Michael Kieschnick,
Jan Meijer,
Axel Thielscher,
Hartwig Roman Siebner,
Kirstine Berg-Sørensen,
Jean-François Perrier,
Alexander Huck,
Ulrik Lund Andersen
Abstract:
The detection of physiological activity at the microscopic level is key for understanding the function of biosystems and relating this to physical structure. Current sensing methods often rely on invasive probes to stimulate and detect activity, bearing the risk of inducing damage in the target system. In recent years, a new type of biosensor based on color centers in diamond offers the possibilit…
▽ More
The detection of physiological activity at the microscopic level is key for understanding the function of biosystems and relating this to physical structure. Current sensing methods often rely on invasive probes to stimulate and detect activity, bearing the risk of inducing damage in the target system. In recent years, a new type of biosensor based on color centers in diamond offers the possibility to passively, noninvasively sense and image living biological systems. Here, we use such a sensor for the \textit{in-vitro} recording of the local magnetic field generated by tightly focused, high intensity pulsed laser optogenetic neuromuscular stimulation of the extensor digitorum longus muscles. Recordings captured a compound action potential response and a slow signal component which we seek to explain using a detailed model of the biological system. We show that our sensor is capable of recording localized neuromuscular activity from the laser stimulation site without photovoltaic or fluorescence artifacts associated with alternative techniques. Our work represents an important step towards selective induction of localized neurobiological activity while performing passive sensing and imaging with diamond sensors, motivating further research into map** of neural activity and intra-cellular processes.
△ Less
Submitted 17 December, 2021;
originally announced December 2021.
-
Detection of biological signals from a live mammalian muscle using a diamond quantum sensor
Authors:
James Luke Webb,
Luca Troise,
Nikolaj Winther Hansen,
Christoffer Olsson,
Adam Wojciechowski,
Jocelyn Achard,
Ovidiu Brinza,
Robert Staacke,
Michael Kieschnick,
Jan Meijer,
Axel Thielscher,
Jean-Francois Perrier,
Kirstine Berg-Sorensen,
Alexander Huck,
Ulrik Lund Andersen
Abstract:
The ability to perform noninvasive, non-contact measurements of electric signals produced by action potentials is essential in biomedicine. A key method to do this is to remotely sense signals by the magnetic field they induce. Existing methods for magnetic field sensing of mammalian tissue, used in techniques such as magnetoencephalography of the brain, require cryogenically cooled superconductin…
▽ More
The ability to perform noninvasive, non-contact measurements of electric signals produced by action potentials is essential in biomedicine. A key method to do this is to remotely sense signals by the magnetic field they induce. Existing methods for magnetic field sensing of mammalian tissue, used in techniques such as magnetoencephalography of the brain, require cryogenically cooled superconducting detectors. These have many disadvantages in terms of high cost, flexibility and limited portability as well as poor spatial and temporal resolution. In this work we demonstrate an alternative technique for detecting magnetic fields generated by the current from action potentials in living tissue using nitrogen vacancy centres in diamond. With 50pT/$\sqrt{Hz}$ sensitivity, we show the first measurements of sensing from mammalian tissue with a diamond sensor using mouse muscle optogenetically activated with blue light. We show these measurements can be performed in an ordinary, unshielded lab environment and that the signal can be easily recovered by digital signal processing techniques.
△ Less
Submitted 3 August, 2020;
originally announced August 2020.
-
Accessibility of Cortical Regions to Focal TES: Dependence on Spatial Position, Safety, and Practical Constraints
Authors:
Guilherme Bicalho Saturnino,
Hartwig Roman Siebner,
Axel Thielscher,
Kristoffer Hougaard Madsen
Abstract:
Transcranial electric stimulation (TES) can modulate intrinsic neural activity in the brain by injecting weak currents through electrodes attached to the scalp. TES has been widely used as a neuroscience tool to investigate how behavioural and physiological variables of brain function are modulated by electric stimulation of specific brain regions. For an unambiguous interpretation of TES experime…
▽ More
Transcranial electric stimulation (TES) can modulate intrinsic neural activity in the brain by injecting weak currents through electrodes attached to the scalp. TES has been widely used as a neuroscience tool to investigate how behavioural and physiological variables of brain function are modulated by electric stimulation of specific brain regions. For an unambiguous interpretation of TES experiments, it is important that the electric fields can be steered towards one or several brain regions-of-interest. However, the conductive proprieties of the human head impose inherent physical limitations on how focal the electric fields in the brain produced by multi-electrode TES can be. As a rule of thumb, it is not feasible to target deep brain areas with TES, although focusing the field in some specific deeper locations might be possible due to favourable conductive properties in the surrounding tissue. In the present study, we first propose a novel method for the automatic calculation of electrode placements and stimulation intensities to optimally affect a given target position. We provide a computationally efficient and robust implementation of the optimization procedure that is able to adhere to safety constraints, while explicitly controlling both the number of active electrodes and the angular deviation of the field in the target area relative to the desired field direction. Leveraging the high computational efficiency of our method, we systematically assess the achievable focality of multi-electrode TES for all cortex positions, thereby investigating the dependence on the chosen constraints. Our results provide comprehensive insight into the limitations regarding the achievable TES dose and focality that are imposed by the biophysical constraints and the safety considerations of TES.
△ Less
Submitted 20 September, 2019; v1 submitted 10 September, 2019;
originally announced September 2019.
-
Opto-magnetic imaging of neural network activity in brain slices at high resolution using color centers in diamond
Authors:
Mürsel Karadas,
Adam M. Wojciechowski,
Alexander Huck,
Nils Ole Dalby,
Ulrik Lund Andersen,
Axel Thielscher
Abstract:
We suggest a novel approach for wide-field imaging of the neural network dynamics of brain slices that uses highly sensitivity magnetometry based on nitrogen-vacancy (NV) centers in diamond. In-vitro recordings in brain slices is a proven method for the characterization of electrical neural activity and has strongly contributed to our understanding of the mechanisms that govern neural information…
▽ More
We suggest a novel approach for wide-field imaging of the neural network dynamics of brain slices that uses highly sensitivity magnetometry based on nitrogen-vacancy (NV) centers in diamond. In-vitro recordings in brain slices is a proven method for the characterization of electrical neural activity and has strongly contributed to our understanding of the mechanisms that govern neural information processing. However, traditional recordings can only acquire signals from a few positions simultaneously, which severely limits their ability to characterize the dynamics of the underlying neural networks. We suggest to radically extend the scope of this method using the wide-field imaging of the neural magnetic fields across the slice by means of NV magnetometry. Employing comprehensive computational simulations and theoretical analyses, we characterize the spatiotemporal characteristics of the neural magnetic fields and derive the required key performance parameters of an imaging setup based on NV magnetometry. In particular, we determine how the technical parameters determine the achievable spatial resolution for an optimal reconstruction of the neural currents from the measured field distributions. Finally, we compare the imaging of neural slice activity with that of a single planar pyramidal cell. Our results suggest that imaging of neural slice activity will be possible with the upcoming generation of NV magnetic field sensors, while imaging of the activity of a single planar cell remains more challenging.
△ Less
Submitted 21 August, 2017;
originally announced August 2017.