The GlueX Beamline and Detector
Authors:
S. Adhikari,
C. S. Akondi,
H. Al Ghoul,
A. Ali,
M. Amaryan,
E. G. Anassontzis,
A. Austregesilo,
F. Barbosa,
J. Barlow,
A. Barnes,
E. Barriga,
R. Barsotti,
T. D. Beattie,
J. Benesch,
V. V. Berdnikov,
G. Biallas,
T. Black,
W. Boeglin,
P. Brindza,
W. J. Briscoe,
T. Britton,
J. Brock,
W. K. Brooks,
B. E. Cannon,
C. Carlin
, et al. (165 additional authors not shown)
Abstract:
The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based…
▽ More
The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based on triplet photoproduction. Charged-particle tracks from interactions in the central target are analyzed in a solenoidal field using a central straw-tube drift chamber and six packages of planar chambers with cathode strips and drift wires. Electromagnetic showers are reconstructed in a cylindrical scintillating fiber calorimeter inside the magnet and a lead-glass array downstream. Charged particle identification is achieved by measuring energy loss in the wire chambers and using the flight time of particles between the target and detectors outside the magnet. The signals from all detectors are recorded with flash ADCs and/or pipeline TDCs into memories allowing trigger decisions with a latency of 3.3 $μ$s. The detector operates routinely at trigger rates of 40 kHz and data rates of 600 megabytes per second. We describe the photon beam, the GlueX detector components, electronics, data-acquisition and monitoring systems, and the performance of the experiment during the first three years of operation.
△ Less
Submitted 26 October, 2020; v1 submitted 28 May, 2020;
originally announced May 2020.
Energy Calibration of the JLab Bremsstrahlung Tagging System
Authors:
S. Stepanyan,
S. Boyarinov,
H. Egiyan,
L. Guo,
D. Dale,
M. Gabrielyan,
L. Gan,
A. Gasparian,
A. Glamazdin,
B. Mecking,
I. Nakagawa,
A. Teymurazyan,
M. H. Wood
Abstract:
In this report, we present the energy calibration of the Hall B bremsstrahlung tagging system at the Thomas Jefferson National Accelerator Facility. The calibration was performed using a magnetic pair spectrometer. The tagged photon energy spectrum was measured in coincidence with $e^+e^-$ pairs as a function of the pair spectrometer magnetic field. Taking advantage of the internal linearity of…
▽ More
In this report, we present the energy calibration of the Hall B bremsstrahlung tagging system at the Thomas Jefferson National Accelerator Facility. The calibration was performed using a magnetic pair spectrometer. The tagged photon energy spectrum was measured in coincidence with $e^+e^-$ pairs as a function of the pair spectrometer magnetic field. Taking advantage of the internal linearity of the pair spectrometer, the energy of the tagging system was calibrated at the level of $\pm 0.1% E_γ$. The absolute energy scale was determined using the $e^+e^-$ rate measurements close to the end-point of the photon spectrum. The energy variations across the full tagging range were found to be $<3$ MeV.
△ Less
Submitted 19 December, 2006; v1 submitted 31 August, 2006;
originally announced August 2006.