-
Cryogenic suspension design for a kilometer-scale gravitational-wave detector
Authors:
Takafumi Ushiba,
Tomotada Akutsu,
Yoichi Aso,
Sakae Araki,
Rishabh Bajpai,
Dan Chen,
Kieran Craig,
William Creus,
Yutaro Enomoto,
Yoshinori Fujii,
Masashi Fukunaga,
Ayako Hagiwara,
Sadakazu Haino,
Kunihiko Hasegawa,
Yuki Inoue,
Kiwamu Izumi,
Nobuhiro Kimura,
Keiko Kokeyama,
Rahul Kumar,
Ettore Majorana,
Yuta Michimura,
Takahiro Miyamoto,
Shinji Miyoki,
Iwao Murakami,
Yoshikazu Namai
, et al. (21 additional authors not shown)
Abstract:
We report the mirror suspension design for Large-scale Cryogenic Gravitational wave Telescope, KAGRA, during bKAGRA Phase 1. Mirror thermal noise is one of the fundamental noises for room-temperature gravitational-wave detectors such as Advanced LIGO and Advanced Virgo. Thus, reduction of thermal noise is required for further improvement of their sensitivity. One effective approach for reducing th…
▽ More
We report the mirror suspension design for Large-scale Cryogenic Gravitational wave Telescope, KAGRA, during bKAGRA Phase 1. Mirror thermal noise is one of the fundamental noises for room-temperature gravitational-wave detectors such as Advanced LIGO and Advanced Virgo. Thus, reduction of thermal noise is required for further improvement of their sensitivity. One effective approach for reducing thermal noise is to cool the mirrors. There are many technical challenges that must be overcome to cool the mirrors, such as cryocooler induced vibrations, thermal drift in suspensions, and reduction in duty cycling due to the increased number of potential failure mechanisms. Our mirror suspension has a black coating that makes radiative cooling more efficient. For conduction cooling, we developed ultra high purity aluminum heat links, which yield high thermal conductivity while kee** the spring constant sufficiently small. A unique inclination adjustment system, called moving mass, is used for aligning the mirror orientation in pitch. Photo-reflective displacement sensors, which have a large range, are installed for dam** control on marionette recoil mass and intermediate recoil mass. Samarium cobalt magnets are used for coil-magnet actuators to prevent significant change of magnetism between room temperature and cryogenic temperature. In this paper, the design of our first cryogenic payload and its performance during bKAGRA Phase 1 are discussed.
△ Less
Submitted 25 January, 2021; v1 submitted 5 October, 2020;
originally announced October 2020.
-
Novel multi-layer plastic-scintillator-based solid active proton target for inverse-kinematics experiments
Authors:
D. T. Tran,
S. Terashima,
H. J. Ong,
K. Hirakawa,
Y. Matsuda,
N. Aoi,
M. N. Harakeh,
M. Itoh,
T. Kawabata,
A. Kohda,
S. Y. Matsumoto,
T. Nishi,
J. Okamoto,
I. Tanihata
Abstract:
We have constructed and tested a novel plastic-scintillator-based solid-state active proton target for use in nuclear spectroscopic studies with nuclear reactions induced by an ion beam in inverse kinematics. The active target system, named Stack Structure Solid organic Scintillator Active Target (S4AT), consists of five layers of plastic scintillators, each with a 1-mm thickness. To determine the…
▽ More
We have constructed and tested a novel plastic-scintillator-based solid-state active proton target for use in nuclear spectroscopic studies with nuclear reactions induced by an ion beam in inverse kinematics. The active target system, named Stack Structure Solid organic Scintillator Active Target (S4AT), consists of five layers of plastic scintillators, each with a 1-mm thickness. To determine the reaction point in the thickness direction, we exploit the difference in the energy losses due to the beam particle and the charged reaction product(s) in the scintillator material. S4AT offers the prospect of a relatively thick target while maintaining a good energy resolution. By considering the relative energy loss between different layers, the energy loss due to unreacted beam particles can be eliminated. Such procedure, made possible by the multi-layer structure, is essential to eliminate the effect of unreacted accompanying beam particles, thus enabling its operation at a moderate beam intensity of up to a few Mcps. We evaluated the performance of S4AT by measuring the elastic proton-proton scattering using a 70-MeV proton beam at Cyclotron and Radioisotope Center (CYRIC), Tohoku University.
△ Less
Submitted 15 November, 2019;
originally announced November 2019.
-
First cryogenic test operation of underground km-scale gravitational-wave observatory KAGRA
Authors:
KAGRA Collaboration,
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
S. Bae,
L. Baiotti,
M. A. Barton,
K. Cannon,
E. Capocasa,
C-S. Chen,
T-W. Chiu,
K. Cho,
Y-K. Chu,
K. Craig,
W. Creus,
K. Doi,
K. Eda
, et al. (179 additional authors not shown)
Abstract:
KAGRA is a second-generation interferometric gravitational-wave detector with 3-km arms constructed at Kamioka, Gifu in Japan. It is now in its final installation phase, which we call bKAGRA (baseline KAGRA), with scientific observations expected to begin in late 2019. One of the advantages of KAGRA is its underground location of at least 200 m below the ground surface, which brings small seismic…
▽ More
KAGRA is a second-generation interferometric gravitational-wave detector with 3-km arms constructed at Kamioka, Gifu in Japan. It is now in its final installation phase, which we call bKAGRA (baseline KAGRA), with scientific observations expected to begin in late 2019. One of the advantages of KAGRA is its underground location of at least 200 m below the ground surface, which brings small seismic motion at low frequencies and high stability of the detector. Another advantage is that it cools down the sapphire test mass mirrors to cryogenic temperatures to reduce thermal noise. In April-May 2018, we have operated a 3-km Michelson interferometer with a cryogenic test mass for 10 days, which was the first time that km-scale interferometer was operated at cryogenic temperatures. In this article, we report the results of this "bKAGRA Phase 1" operation. We have demonstrated the feasibility of 3-km interferometer alignment and control with cryogenic mirrors.
△ Less
Submitted 11 January, 2019;
originally announced January 2019.
-
Improvement of charge resolution for radioactive heavy ions at relativistic energies using a hybrid detector system
Authors:
J. W. Zhao,
B. H. Sun,
L. C. He,
G. S. Li,
W. J. Lin,
C. Y. Liu,
Z. Liu,
C. G. Lu,
D. P. Shen,
Y. Z. Sun,
Z. Y. Sun,
I. Tanihata,
S. Terashima,
D. T. Tran,
F. Wang,
J. Wang,
S. T. Wang,
X. L. Wei,
X. D. Xu,
L. H. Zhu,
J. C. Zhang,
X. H. Zhang,
Y. Zhang,
Z. T. Zhou,
Z. T. Zhou
Abstract:
In typical nuclear physics experiments with radioactive ion beams (RIBs) selected by the in-flight separation technique, Si detectors or ionization chambers are usually equipped for the charge determination of RIBs. The obtained charge resolution relies on the performance of these detectors for energy loss determination, and this affects the particle identification capability of RIBs. We present a…
▽ More
In typical nuclear physics experiments with radioactive ion beams (RIBs) selected by the in-flight separation technique, Si detectors or ionization chambers are usually equipped for the charge determination of RIBs. The obtained charge resolution relies on the performance of these detectors for energy loss determination, and this affects the particle identification capability of RIBs. We present an approach on improving the resolution of charge measurement for heavy ions by using the abundant energy loss information from different types of existing detectors along the beam line. Without altering the beam line and detectors, this approach can improve the charge resolution by more than 12\% relative to the multiple sampling ionization chamber of the best resolution.
△ Less
Submitted 9 January, 2019;
originally announced January 2019.
-
Towards the full realization of the RIBLL2 beam line at the HIRFL-CSR complex
Authors:
Bao-Hua Sun,
Jian-Wei Zhao,
Xue-Heng Zhang,
Li-Na Sheng,
Zhi-Yu Sun,
Isao Tanihata,
Satoru Terashima,
Yong Zheng,
Li-Hua Zhu,
Li-Min Duan,
Liu-Chun He,
Rong-Jiang Hu,
Guang-Shuai Li,
Wen-Jian Lin,
Wei-** Lin,
Chuan-Ye Liu,
Zhong Liu,
Chen-Gui Lu,
Xin-Wen Ma,
Li-Jun Mao,
Yi Tian,
Feng Wang,
Meng Wang,
Shi-Tao Wang,
Jia-Wen Xia
, et al. (9 additional authors not shown)
Abstract:
The RIBLL2 in-flight separator at IMP, the secondary beam line between two storage rings at the \blue{\uwave{Heavy Ion Research Facility in Lanzhou (HIRFL-CSR)}}, has been commissioned to study the rare-isotope beam (RIB) physics at around 300 MeV/nucleon for the first time, in combination of the external target facility (ETF). The unambiguous particle identification in mass and charge states for…
▽ More
The RIBLL2 in-flight separator at IMP, the secondary beam line between two storage rings at the \blue{\uwave{Heavy Ion Research Facility in Lanzhou (HIRFL-CSR)}}, has been commissioned to study the rare-isotope beam (RIB) physics at around 300 MeV/nucleon for the first time, in combination of the external target facility (ETF). The unambiguous particle identification in mass and charge states for $^{18}$O and $^{40}$Ar fragments has been achieved in recent experiments. A full realization of RIBLL2 will open many potentials to address important RIB physics problems at around 300 MeV/nucleon.
△ Less
Submitted 11 February, 2018; v1 submitted 7 December, 2017;
originally announced December 2017.
-
Multi-layer plastic scintillation detector for intermediate- and high-energy neutrons with $\it{n}$-$γ$ discrimination capability
Authors:
L. Yu,
S. Terashima,
H. J. Ong,
P. Y. Chan,
I. Tanihata,
C. Iwamoto,
D. T. Tran,
A. Tamii,
N. Aoi,
H. Fujioka,
G. Gey,
H. Sakaguchi,
A. Sakaue,
B. H. Sun,
T. L. Tang,
T. F. Wang,
Y. N. Watanabe,
G. X. Zhang
Abstract:
A new type of neutron detector, named Stack Structure Solid organic Scintillator (S$^4$), consisting of multi-layer plastic scintillators with capability to suppress low-energy $γ$ rays under high-counting rate has been constructed and tested. To achieve $\it{n}$-$γ$ discrimination, we exploit the difference in the ranges of the secondary charged particles produced by the interactions of neutrons…
▽ More
A new type of neutron detector, named Stack Structure Solid organic Scintillator (S$^4$), consisting of multi-layer plastic scintillators with capability to suppress low-energy $γ$ rays under high-counting rate has been constructed and tested. To achieve $\it{n}$-$γ$ discrimination, we exploit the difference in the ranges of the secondary charged particles produced by the interactions of neutrons and $γ$ rays in the scintillator material. The thickness of a plastic scintillator layer was determined based on the results of Monte Carlo simulations using the Geant4 toolkit. With layer thicknesses of 5 mm, we have achieved a good separation between neutrons and $γ$ rays at 5 MeV$_{\rm ee}$ threshold setting. We have also determined the detection efficiencies using monoenergetic neutrons at two energies produced by the $\it{d}$+$\it{d}\to\it{n}$+$^{3}$He reaction. The results agree well with the Geant4 simulations implementing the Li$\grave{\rm e}$ge Intranuclear Cascade hadronic model (INCL++) and the high-precision model of low-energy neutron interactions (NeutronHP).
△ Less
Submitted 27 July, 2017;
originally announced July 2017.
-
Plastic scintillation detectors for precision time-of-flight measurements of relativistic heavy ions
Authors:
Wen-Jian Lin,
Jian-Wei Zhao,
Bao-Hua Sun,
Liu-Chun He,
Wei-** Lin,
Chuan-Ye Liu,
Isao Tanihata,
Satoru Terashima,
Yi Tian,
Feng Wang,
Meng Wang,
Guang-Xin Zhang,
Xue-Heng Zhang,
Li-Hua Zhu,
Li-Min Duan,
Rong-Jiang Hu,
Zhong Liu,
Chen-Gui Lu,
Pei-Pei Ren,
Li-Na Sheng,
Zhi-Yu Sun,
Shi-Tao Wang,
Tao-Feng Wang,
Zhi-Guo Xu,
Duo Yan
, et al. (2 additional authors not shown)
Abstract:
Plastic scintillation detectors for Time-of-Flight (TOF) measurements are almost essential for event-by-event identification of relativistic rare isotopes. In this work, a pair of plastic scintillation detectors of 50 $\times$ 50 $\times$ 3$^{t}$ mm$^3$ and 80 $\times$ 100 $\times$ 3$^{t}$ mm$^3$ have been set up at the external target facility (ETF), Institute of Modern Physics. Their time, energ…
▽ More
Plastic scintillation detectors for Time-of-Flight (TOF) measurements are almost essential for event-by-event identification of relativistic rare isotopes. In this work, a pair of plastic scintillation detectors of 50 $\times$ 50 $\times$ 3$^{t}$ mm$^3$ and 80 $\times$ 100 $\times$ 3$^{t}$ mm$^3$ have been set up at the external target facility (ETF), Institute of Modern Physics. Their time, energy and position responses are measured with $^{18}$O primary beam at 400 MeV/nucleon. After the off-line walk-effect and position corrections, the time resolution of the two detectors are determined to be 27 ps ($σ$) and 36 ps ($σ$), respectively. Both detectors have nearly the same energy resolution of 3$\%$ ($σ$) and position resolution of 2 mm ($σ$). The detectors have been used successfully in nuclear reaction cross section measurements, and will be be employed for upgrading RIBLL2 beam line at IMP as well as for the high energy branch at HIAF.
△ Less
Submitted 27 September, 2016;
originally announced September 2016.
-
Development of a fast plastic scintillation detector with time resolution of less than 10 ps
Authors:
J. W. Zhao,
B. H. Sun,
I. Tanihata,
S. Terashima,
L. H. Zhu,
A. Enomoto,
D. Nagae,
T. Nishimura,
S. Omika,
A. Ozawa,
Y. Takeuchi,
T. Yamaguchi
Abstract:
Timing-pick up detectors with excellent timing resolutions are essential in many modern nuclear physics experiments. Aiming to develop a Time-Of-Flight system with precision down to about 10 ps, we have made a systematic study of the timing characteristic of TOF detectors, which consist of several combinations of plastic scintillators and photomultiplier tubes. With the conventional electronics, t…
▽ More
Timing-pick up detectors with excellent timing resolutions are essential in many modern nuclear physics experiments. Aiming to develop a Time-Of-Flight system with precision down to about 10 ps, we have made a systematic study of the timing characteristic of TOF detectors, which consist of several combinations of plastic scintillators and photomultiplier tubes. With the conventional electronics, the best timing resolution of about 5.1 ps (σ) has been achieved for detectors with an area size of 3x1 cm2. It is found that for data digitalization a combination of TAC and ADC can achieve a better time resolution than currently available TDC. Simultaneously measurements of both time and pulse height are very valuable for correction of time-walk effect.
△ Less
Submitted 30 January, 2016;
originally announced February 2016.