-
Zepto to Attosecond core-level photoemission time delays in homonuclear diatomic molecules and non-dipole effects in the framework of Multiple Scattering theory
Authors:
Yoshiaki Tamura,
Kaoru Yamazaki,
Kiyoshi Ueda,
Keisuke Hatada
Abstract:
We report a theoretical study of the angular distribution of core-level photoemission time delay in a molecular frame, which is converting into possible measure with the development of attosecond pulsed lasers and metrology, focusing on homonuclear diatomic molecules. Two-center interference patterns in gerade and ungerade core-level molecular-frame photoelectron angular distributions (MFPADs) of…
▽ More
We report a theoretical study of the angular distribution of core-level photoemission time delay in a molecular frame, which is converting into possible measure with the development of attosecond pulsed lasers and metrology, focusing on homonuclear diatomic molecules. Two-center interference patterns in gerade and ungerade core-level molecular-frame photoelectron angular distributions (MFPADs) of homonuclear diatomic molecules exhibit symmetry-broken with respect to the direction of light propagation due to the non-dipole (multipole) effect. In this study, we investigate the photoemission time delay due to the non-dipole effect by introducing a theoretical model. We show that in incoherent sums, considering the average of the contributions from the gerade and ungerade delocalized core states, two-center interference terms cancel each other out in both of the MFPADs and photoemission time delays; however, there remains a residual term exhibiting the non-dipole effect for the photoemission time delays. By expanding the scattering state of photoelectrons with Multiple Scattering theory, we also demonstrate that the scattering effect at the molecular potential plays a crucial role in the descriptions of the photoemission time delays of homonuclear diatomic molecules. Furthermore, we demonstrated that the direct wave contribution does not show angular dependence in the photoemission time delays. We then apply the theoretical model to a nitrogen molecule to show the energy- and angular dependence of the MFPADs and photoemission time delays both analytically and numerically. While the incoherent sums of the MFPADs in a given and opposite direction have the same intensity, the incoherent sums of the photoemission time delays depicts a few hundred zeptosecond difference from numerical calculations by multiple scattering code.
△ Less
Submitted 4 February, 2024;
originally announced February 2024.
-
A multiple scattering theoretical approach to time delay in high energy core-level photoemission of heteronuclear diatomic molecules
Authors:
Y. Tamura,
K. Yamazaki,
K. Ueda,
K. Hatada
Abstract:
We present analytical expressions of momentum-resolved core-level photoemission time delay in a molecular frame of a heteronuclear diatomic molecule upon photoionization by a linearly polarized soft x-rays attosecond pulse. For this purpose, we start to derive a general expression of photoemission time delay based on the first order time dependent perturbation theory within the one electron and si…
▽ More
We present analytical expressions of momentum-resolved core-level photoemission time delay in a molecular frame of a heteronuclear diatomic molecule upon photoionization by a linearly polarized soft x-rays attosecond pulse. For this purpose, we start to derive a general expression of photoemission time delay based on the first order time dependent perturbation theory within the one electron and single channel model in the fixed-in-space system (atoms, molecules and crystals) and apply it to the core-level photoemission within the electric dipole approximation. By using multiple scattering theory and applying series expansion, plane wave and muffin-tin approximations, the core-level photoemission time delay $t$ is divided into three components, $t_{\rm abs}$, $t_{\rm path}$ and $t_{\rm sc}$, which are atomic photoemission time delay, delays caused by the propagation of photoelectron among the surrounding atoms and the scattering of photoelectron by them, respectively. We applied single scattering approximation to $t_{\rm path}$ and obtained $t_{\rm path}^{(1)}(k,θ)$ with polarization vector parallel to the molecular axis for a heteronuclear diatomic molecule, where $θ$ is the angle of measured photoelectron from the molecular axis. $t$ is approximated well with this simplified expression $t_{\rm path}^{(1)}(k,θ)$ in the high energy regime ($k\gtrsim 3.5\,\, {\rm a.u.}^{-1}$), and the validity of this estimated result is confirmed by comparing it with multiple scattering calculations for C 1$s$ core-level photoemission time delay of CO molecules. $t_{\rm path}^{(1)}(k,θ)$ shows characteristic dependence on $θ$, it becomes zero at $θ=0$, exhibits EXAFS type oscillation with $2kR$ at $θ=π$, where $R$ is the bondlength, and gives just the travelling time of photoelectron from the absorbing atom to the neighbouring atom at $θ=π/2$.
△ Less
Submitted 30 May, 2022; v1 submitted 6 March, 2022;
originally announced March 2022.
-
High-Energy Molecular-Frame Photoelectron Angular Distributions: A Molecular Bond-Length Ruler
Authors:
Isabel Vela-Peréz,
Fukiko Ota,
Abir Mhamdi,
Yoshiaki Tamura,
Jonas Rist,
Niklas Melzer,
Safak Uerken,
Giammarco Nalin,
Nils Anders,
Daehyun You,
Max Kircher,
Christian Janke,
Markus Waitz,
Florian Trinter,
Renaud Guillemin,
Maria Novella Piancastelli,
Marc Simon,
Vernon T. Davis,
Joshua B. Williams,
Reinhard Dörner,
Keisuke Hatada,
Kaoru Yamazaki,
Kilian Fehre,
Philipp V. Demekhin,
Kiyoshi Ueda
, et al. (2 additional authors not shown)
Abstract:
We present an experimental and theoretical study of core-level ionization of small hetero- and homo-nuclear molecules employing circularly polarized light and address molecular-frame photoelectron angular distributions in the light's polarization plane (CP-MFPADs). We find that the main forward-scattering peaks of CP-MFPADs are slightly tilted with respect to the molecular axis. We show that this…
▽ More
We present an experimental and theoretical study of core-level ionization of small hetero- and homo-nuclear molecules employing circularly polarized light and address molecular-frame photoelectron angular distributions in the light's polarization plane (CP-MFPADs). We find that the main forward-scattering peaks of CP-MFPADs are slightly tilted with respect to the molecular axis. We show that this tilt angle can be directly connected to the molecular bond length by a simple, universal formula. The extraction of the bond length becomes more accurate as the photoelectron energy is increased. We apply the derived formula to several examples of CP-MFPADs of C 1s and O 1s photoelectrons of CO, which have been measured experimentally or obtained by means of ab initio modeling. The photoelectron kinetic energies range from 70 to 1000~eV and the extracted bond lengths agree well with the known bond length of the CO molecule in its ground state. In addition, we discuss the influence of the back-scattering contribution that is superimposed over the analyzed forward-scattering peak in case of homo-nuclear diatomic molecules as N$_2$.
△ Less
Submitted 25 May, 2021;
originally announced May 2021.
-
Study of the interactions of pions in the CALICE silicon-tungsten calorimeter prototype
Authors:
C. Adloff,
Y. Karyotakis,
J. Repond,
J. Yu,
G. Eigen,
Y. Mikami,
N. K. Watson,
J. A. Wilson,
T. Goto,
G. Mavromanolakis,
M. A. Thomson,
D. R. Ward,
W. Yan,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
J. Apostolakis,
A. Ribon,
V. Uzhinskiy,
M. Benyamna,
C. Cârloganu,
F. Fehr,
P. Gay,
G. C. Blazey,
D. Chakraborty
, et al. (133 additional authors not shown)
Abstract:
A prototype silicon-tungsten electromagnetic calorimeter for an ILC detector was tested in 2007 at the CERN SPS test beam. Data were collected with electron and hadron beams in the energy range 8 to 80 GeV. The analysis described here focuses on the interactions of pions in the calorimeter. One of the main objectives of the CALICE program is to validate the Monte Carlo tools available for the…
▽ More
A prototype silicon-tungsten electromagnetic calorimeter for an ILC detector was tested in 2007 at the CERN SPS test beam. Data were collected with electron and hadron beams in the energy range 8 to 80 GeV. The analysis described here focuses on the interactions of pions in the calorimeter. One of the main objectives of the CALICE program is to validate the Monte Carlo tools available for the design of a full-sized detector. The interactions of pions in the Si-W calorimeter are therefore confronted with the predictions of various physical models implemented in the GEANT4 simulation framework.
△ Less
Submitted 28 April, 2010;
originally announced April 2010.
-
Construction and Commissioning of the CALICE Analog Hadron Calorimeter Prototype
Authors:
C. Adloff,
Y. Karyotakis,
J. Repond,
A. Brandt,
H. Brown,
K. De,
C. Medina,
J. Smith,
J. Li,
M. Sosebee,
A. White,
J. Yu,
T. Buanes,
G. Eigen,
Y. Mikami,
O. Miller,
N. K. Watson,
J. A. Wilson,
T. Goto,
G. Mavromanolakis,
M. A. Thomson,
D. R. Ward,
W. Yan,
D. Benchekroun,
A. Hoummada
, et al. (205 additional authors not shown)
Abstract:
An analog hadron calorimeter (AHCAL) prototype of 5.3 nuclear interaction lengths thickness has been constructed by members of the CALICE Collaboration. The AHCAL prototype consists of a 38-layer sandwich structure of steel plates and highly-segmented scintillator tiles that are read out by wavelength-shifting fibers coupled to SiPMs. The signal is amplified and shaped with a custom-designed ASIC.…
▽ More
An analog hadron calorimeter (AHCAL) prototype of 5.3 nuclear interaction lengths thickness has been constructed by members of the CALICE Collaboration. The AHCAL prototype consists of a 38-layer sandwich structure of steel plates and highly-segmented scintillator tiles that are read out by wavelength-shifting fibers coupled to SiPMs. The signal is amplified and shaped with a custom-designed ASIC. A calibration/monitoring system based on LED light was developed to monitor the SiPM gain and to measure the full SiPM response curve in order to correct for non-linearity. Ultimately, the physics goals are the study of hadron shower shapes and testing the concept of particle flow. The technical goal consists of measuring the performance and reliability of 7608 SiPMs. The AHCAL was commissioned in test beams at DESY and CERN. The entire prototype was completed in 2007 and recorded hadron showers, electron showers and muons at different energies and incident angles in test beams at CERN and Fermilab.
△ Less
Submitted 12 March, 2010;
originally announced March 2010.
-
Design and Electronics Commissioning of the Physics Prototype of a Si-W Electromagnetic Calorimeter for the International Linear Collider
Authors:
CALICE Collaboration,
J. Repond,
J. Yu,
C. M. Hawkes,
Y. Mikami,
O. Miller,
N. K. Watson,
J. A. Wilson,
G. Mavromanolakis,
M. A. Thomson,
D. R. Ward,
W. Yan,
F. Badaud,
D. Boumediene,
C. Carloganu,
R. Cornat,
P. Gay,
Ph. Gris,
S. Manen,
F. Morisseau,
L. Royer,
G. C. Blazey,
D. Chakraborty,
A. Dyshkant,
K. Francis
, et al. (92 additional authors not shown)
Abstract:
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the electromagnetic calorimeter, the current baseline choice is a high granularity sampling calorimeter with tungsten as absorber and silicon detectors as sensitive material. A ``physics prototype'' has been constructed, consisting…
▽ More
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the electromagnetic calorimeter, the current baseline choice is a high granularity sampling calorimeter with tungsten as absorber and silicon detectors as sensitive material. A ``physics prototype'' has been constructed, consisting of thirty sensitive layers. Each layer has an active area of 18x18 cm2 and a pad size of 1x1 cm2. The absorber thickness totals 24 radiation lengths. It has been exposed in 2006 and 2007 to electron and hadron beams at the DESY and CERN beam test facilities, using a wide range of beam energies and incidence angles. In this paper, the prototype and the data acquisition chain are described and a summary of the data taken in the 2006 beam tests is presented. The methods used to subtract the pedestals and calibrate the detector are detailed. The signal-over-noise ratio has been measured at 7.63 +/- 0.01. Some electronics features have been observed; these lead to coherent noise and crosstalk between pads, and also crosstalk between sensitive and passive areas. The performance achieved in terms of uniformity and stability is presented.
△ Less
Submitted 5 August, 2008; v1 submitted 29 May, 2008;
originally announced May 2008.
-
Development of Multi-Pixel Photon Counters
Authors:
M. Yokoyama,
T. Nobuhara,
M. Taguchi,
T. Nakaya,
T. Murakami,
T. Nakadaira,
K. Yoshimura,
K. Kawagoe,
Y. Tamura,
T. Iijima,
Y. Mazuka,
K. Miyabayashi,
S. Iba,
H. Miyata,
T. Takeshita
Abstract:
The multi-pixel photon counter (MPPC) is a newly developed photodetector with an excellent photon counting capability. It also has many attractive features such as small size, high gain, low operation voltage and power consumption, and capability of operating in magnetic fields and in room temperature. The basic performance of samples has been measured. A gain of ~10^6 is achieved with a noise r…
▽ More
The multi-pixel photon counter (MPPC) is a newly developed photodetector with an excellent photon counting capability. It also has many attractive features such as small size, high gain, low operation voltage and power consumption, and capability of operating in magnetic fields and in room temperature. The basic performance of samples has been measured. A gain of ~10^6 is achieved with a noise rate less than 1 MHz with 1 p.e. threshold, and cross-talk probability of less than 30% at room temperature. The photon detection efficiency for green light is twice or more that of the photomultiplier tubes. It is found that the basic performance of the MPPC is satisfactory for use in real experiments.
△ Less
Submitted 29 May, 2006;
originally announced May 2006.