-
Lifetime of the $^2F_{7/2}$ level in Yb$^+$ for spontaneous emission of electric octupole radiation
Authors:
R. Lange,
A. A. Peshkov,
N. Huntemann,
Chr. Tamm,
A. Surzhykov,
E. Peik
Abstract:
We report a measurement of the radiative lifetime of the $^2F_{7/2}$ level of $^{171}$Yb$^+$ that is coupled to the $^2S_{1/2}$ ground state via an electric octupole transition. The radiative lifetime is determined to be $4.98(25)\times 10^7$ s, corresponding to 1.58(8) years. The result reduces the relative uncertainty in this exceptionally long excited state lifetime by one order of magnitude wi…
▽ More
We report a measurement of the radiative lifetime of the $^2F_{7/2}$ level of $^{171}$Yb$^+$ that is coupled to the $^2S_{1/2}$ ground state via an electric octupole transition. The radiative lifetime is determined to be $4.98(25)\times 10^7$ s, corresponding to 1.58(8) years. The result reduces the relative uncertainty in this exceptionally long excited state lifetime by one order of magnitude with respect to previous experimental estimates. Our method is based on the coherent excitation of the corresponding transition and avoids limitations through competing decay processes. The explicit dependence on the laser intensity is eliminated by simultaneously measuring the resonant Rabi frequency and the induced quadratic Stark shift. Combining the result with information on the dynamic differential polarizability permits a calculation of the transition matrix element to infer the radiative lifetime.
△ Less
Submitted 23 July, 2021;
originally announced July 2021.
-
Improved limits for violations of local position invariance from atomic clock comparisons
Authors:
R. Lange,
N. Huntemann,
J. M. Rahm,
C. Sanner,
H. Shao,
B. Lipphardt,
Chr. Tamm,
S. Weyers,
E. Peik
Abstract:
We compare two optical clocks based on the $^2$S$_{1/2}(F=0)\to {}^2$D$_{3/2}(F=2)$ electric quadrupole (E2) and the $^2$S$_{1/2}(F=0)\to {}^2$F$_{7/2}(F=3)$ electric octupole (E3) transition of $^{171}$Yb$^{+}$ and measure the frequency ratio $ν_{\mathrm{E3}}/ν_{\mathrm{E2}}=0.932\,829\,404\,530\,965\,376(32)$. We determine the transition frequency $ν_{E3}=642\,121\,496\,772\,645.10(8)$ Hz using…
▽ More
We compare two optical clocks based on the $^2$S$_{1/2}(F=0)\to {}^2$D$_{3/2}(F=2)$ electric quadrupole (E2) and the $^2$S$_{1/2}(F=0)\to {}^2$F$_{7/2}(F=3)$ electric octupole (E3) transition of $^{171}$Yb$^{+}$ and measure the frequency ratio $ν_{\mathrm{E3}}/ν_{\mathrm{E2}}=0.932\,829\,404\,530\,965\,376(32)$. We determine the transition frequency $ν_{E3}=642\,121\,496\,772\,645.10(8)$ Hz using two caesium fountain clocks. Repeated measurements of both quantities over several years are analyzed for potential violations of local position invariance. We improve by factors of about 20 and 2 the limits for fractional temporal variations of the fine structure constant $α$ to $1.0(1.1)\times10^{-18}/\mathrm{yr}$ and of the proton-to-electron mass ratio $μ$ to $-8(36)\times10^{-18}/\mathrm{yr}$. Using the annual variation of the Sun's gravitational potential at Earth $Φ$, we improve limits for a potential coupling of both constants to gravity, $(c^2/α) (dα/dΦ)=14(11)\times 10^{-9}$ and $(c^2/μ) (dμ/dΦ)=7(45)\times 10^{-8}$.
△ Less
Submitted 7 January, 2021; v1 submitted 13 October, 2020;
originally announced October 2020.
-
Coherent suppression of tensor frequency shifts through magnetic field rotation
Authors:
R. Lange,
N. Huntemann,
C. Sanner,
H. Shao,
B. Lipphardt,
Chr. Tamm,
E. Peik
Abstract:
We introduce a scheme to coherently suppress second-rank tensor frequency shifts in atomic clocks, relying on the continuous rotation of an external magnetic field during the free atomic state evolution in a Ramsey sequence. The method retrieves the unperturbed frequency within a single interrogation cycle and is readily applicable to various atomic clock systems. For the frequency shift due to th…
▽ More
We introduce a scheme to coherently suppress second-rank tensor frequency shifts in atomic clocks, relying on the continuous rotation of an external magnetic field during the free atomic state evolution in a Ramsey sequence. The method retrieves the unperturbed frequency within a single interrogation cycle and is readily applicable to various atomic clock systems. For the frequency shift due to the electric quadrupole interaction, we experimentally demonstrate suppression by more than two orders of magnitude for the ${}^2S_{1/2} \to {}^2D_{3/2}$ transition of a single trapped ${}^{171}\text{Yb}^+$ ion. The scheme provides particular advantages in the case of the ${}^{171}\text{Yb}^+$ ${}^2S_{1/2} \to {}^2F_{7/2}$ electric octupole (E3) transition. For an improved estimate of the residual quadrupole shift for this transition, we measure the excited state electric quadrupole moments $Θ({}^2D_{3/2}) = 1.95(1)~ea_0^2$ and $Θ({}^2F_{7/2}) = -0.0297(5)~ea_0^2$ with $e$ the elementary charge and $a_0$ the Bohr radius, improving the measurement uncertainties by one order of magnitude.
△ Less
Submitted 29 May, 2020;
originally announced May 2020.
-
Generalized excitation of atomic multipole transitions by twisted light modes
Authors:
S. A. -L. Schulz,
A. A. Peshkov,
R. A. Müller,
R. Lange,
N. Huntemann,
Chr. Tamm,
E. Peik,
A. Surzhykov
Abstract:
A theoretical study is performed for the excitation of a single atom localized in the center of twisted light modes. Here we present the explicit dependence of excitation rates on critical parameters, such as the polarization of light, its orbital angular momentum projection, and the orientation of its propagation axis with respect to the atomic quantization axis. The effect of a spatial spread of…
▽ More
A theoretical study is performed for the excitation of a single atom localized in the center of twisted light modes. Here we present the explicit dependence of excitation rates on critical parameters, such as the polarization of light, its orbital angular momentum projection, and the orientation of its propagation axis with respect to the atomic quantization axis. The effect of a spatial spread of the atom is also considered in detail. The expressions for transition rates obtained in this work can be used for any atom of arbitrary electronic configuration. For definiteness we apply them to the specific case of $^{2}S_{1/2} (F=0) \rightarrow\; ^{2}F_{7/2} (F=3, M=0)$ electric octupole (E3) transition in $^{171}$Yb$^{+}$ ion. Our analytical and numerical results are suitable for the analysis and planning of future experiments on the excitation of electric-dipole-forbidden transitions by twisted light modes in optical atomic clocks.
△ Less
Submitted 6 March, 2020;
originally announced March 2020.
-
Direct comparisons of European primary and secondary frequency standards via satellite techniques
Authors:
F. Riedel,
A. Al-Masoudi,
E. Benkler,
S. Dörscher,
V. Gerginov,
C. Grebing,
S. Häfner,
N. Huntemann,
B. Lipphardt,
C. Lisdat,
E. Peik,
D. Piester,
C. Sanner,
C. Tamm,
S. Weyers,
H. Denker,
L. Timmen,
C. Voigt,
D. Calonico,
G. Cerretto,
G. A. Costanzo,
F. Levi,
I. Sesia,
J. Achkar,
J. Guèna
, et al. (24 additional authors not shown)
Abstract:
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taki…
▽ More
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taking into account correlations and gaps in the measurement data, combined overall uncertainties in the range of $1.8 \times 10^{-16}$ to $3.5 \times 10^{-16}$ for the optical clock comparisons were found. The comparison of the fountain clocks yields results with a maximum relative frequency difference of $6.9 \times 10^{-16}$, and combined overall uncertainties in the range of $4.8 \times 10^{-16}$ to $7.7 \times 10^{-16}$.
△ Less
Submitted 9 October, 2019;
originally announced October 2019.
-
Search for transient variations of the fine structure constant and dark matter using fiber-linked optical atomic clocks
Authors:
B. M. Roberts,
P. Delva,
A. Al-Masoudi,
A. Amy-Klein,
C. Bærentsen,
C. F. A. Baynham,
E. Benkler,
S. Bilicki,
S. Bize,
W. Bowden,
J. Calvert,
V. Cambier,
E. Cantin,
E. A. Curtis,
S. Dörscher,
M. Favier,
F. Frank,
P. Gill,
R. M. Godun,
G. Grosche,
C. Guo,
A. Hees,
I. R. Hill,
R. Hobson,
N. Huntemann
, et al. (29 additional authors not shown)
Abstract:
We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17…
▽ More
We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17 for transients of duration 10^3 s. This analysis also presents a possibility to search for dark matter, the mysterious substance hypothesised to explain galaxy dynamics and other astrophysical phenomena that is thought to dominate the matter density of the universe. At the current sensitivity level, we find no evidence for dark matter in the form of topological defects (or, more generally, any macroscopic objects), and we thus place constraints on certain potential couplings between the dark matter and standard model particles, substantially improving upon the existing constraints, particularly for large (>~10^4 km) objects.
△ Less
Submitted 8 July, 2019; v1 submitted 4 July, 2019;
originally announced July 2019.
-
Guidelines for develo** optical clocks with $10^{-18}$ fractional frequency uncertainty
Authors:
Moustafa Abdel-Hafiz,
Piotr Ablewski,
Ali Al-Masoudi,
Héctor Álvarez Martínez,
Petr Balling,
Geoffrey Barwood,
Erik Benkler,
Marcin Bober,
Mateusz Borkowski,
William Bowden,
Roman Ciuryło,
Hubert Cybulski,
Alexandre Didier,
Miroslav Doležal,
Sören Dörscher,
Stephan Falke,
Rachel M. Godun,
Ramiz Hamid,
Ian R. Hill,
Richard Hobson,
Nils Huntemann,
Yann Le Coq,
Rodolphe Le Targat,
Thomas Legero,
Thomas Lindvall
, et al. (20 additional authors not shown)
Abstract:
There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency…
▽ More
There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency standards. This exceptional accuracy and stability is resulting in a growing number of research groups develo** optical clocks. While good review papers covering the topic already exist, more practical guidelines are needed as a complement. The purpose of this document is therefore to provide technical guidance for researchers starting in the field of optical clocks. The target audience includes national metrology institutes (NMIs) wanting to set up optical clocks (or subsystems thereof) and PhD students and postdocs entering the field. Another potential audience is academic groups with experience in atomic physics and atom or ion trap**, but with less experience of time and frequency metrology and optical clock requirements. These guidelines have arisen from the scope of the EMPIR project "Optical clocks with $1 \times 10^{-18}$ uncertainty" (OC18). Therefore, the examples are from European laboratories even though similar work is carried out all over the world. The goal of OC18 was to push the development of optical clocks by improving each of the necessary subsystems: ultrastable lasers, neutral-atom and single-ion traps, and interrogation techniques. This document shares the knowledge acquired by the OC18 project consortium and gives practical guidance on each of these aspects.
△ Less
Submitted 13 August, 2019; v1 submitted 27 June, 2019;
originally announced June 2019.
-
Optical clock comparison test of Lorentz symmetry
Authors:
Christian Sanner,
Nils Huntemann,
Richard Lange,
Christian Tamm,
Ekkehard Peik,
Marianna S. Safronova,
Sergey G. Porsev
Abstract:
Questioning the presumably most basic assumptions about the structure of space and time has revolutionized our understanding of Nature. State-of-the-art atomic clocks make it possible to precisely test fundamental symmetry properties of spacetime, and search for physics beyond the standard model at low energy scales of just a few electron volts. Here, we experimentally demonstrate for the first ti…
▽ More
Questioning the presumably most basic assumptions about the structure of space and time has revolutionized our understanding of Nature. State-of-the-art atomic clocks make it possible to precisely test fundamental symmetry properties of spacetime, and search for physics beyond the standard model at low energy scales of just a few electron volts. Here, we experimentally demonstrate for the first time agreement of two single-ion clocks at the $10^{-18}$ level and directly confirm the validity of their uncertainty budgets over a half-year long comparison period. The two clock ions are confined in separate ion traps with quantization axes aligned along nonparallel directions. Hypothetical Lorentz symmetry violations would lead to sidereal modulations of the frequency offset. From the absence of such modulations at the $10^{-19}$ level we deduce stringent limits on Lorentz symmetry violation parameters for electrons in the range of $10^{-21}$, improving previous limits by two orders of magnitude.
△ Less
Submitted 27 September, 2018;
originally announced September 2018.
-
Auto-Balanced Ramsey Spectroscopy
Authors:
Christian Sanner,
Nils Huntemann,
Richard Lange,
Christian Tamm,
Ekkehard Peik
Abstract:
We devise a perturbation-immune version of Ramsey's method of separated oscillatory fields. Spectroscopy of an atomic clock transition without compromising the clock's accuracy is accomplished by actively balancing the spectroscopic responses from phase-congruent Ramsey probe cycles of unequal durations. Our simple and universal approach eliminates a wide variety of interrogation-induced line shif…
▽ More
We devise a perturbation-immune version of Ramsey's method of separated oscillatory fields. Spectroscopy of an atomic clock transition without compromising the clock's accuracy is accomplished by actively balancing the spectroscopic responses from phase-congruent Ramsey probe cycles of unequal durations. Our simple and universal approach eliminates a wide variety of interrogation-induced line shifts often encountered in high precision spectroscopy, among them, in particular, light shifts, phase chirps, and transient Zeeman shifts. We experimentally demonstrate auto-balanced Ramsey spectroscopy on the light shift prone $^{171}$Yb$^{+}$ electric octupole optical clock transition and show that interrogation defects are not turned into clock errors. This opens up frequency accuracy perspectives below the $10^{-18}$ level for the Yb$^{+}$ system and for other types of optical clocks.
△ Less
Submitted 9 July, 2017;
originally announced July 2017.
-
Single-Ion Atomic Clock with $3\times10^{-18}$ Systematic Uncertainty
Authors:
N. Huntemann,
C. Sanner,
B. Lipphardt,
Chr. Tamm,
E. Peik
Abstract:
We experimentally investigate an optical frequency standard based on the $^2S_{1/2} (F=0)\to {}^2F_{7/2} (F=3)$ electric octupole (\textit{E}3) transition of a single trapped $^{171}$Yb$^+$ ion. For the spectroscopy of this strongly forbidden transition, we utilize a Ramsey-type excitation scheme that provides immunity to probe-induced frequency shifts. The cancellation of these shifts is controll…
▽ More
We experimentally investigate an optical frequency standard based on the $^2S_{1/2} (F=0)\to {}^2F_{7/2} (F=3)$ electric octupole (\textit{E}3) transition of a single trapped $^{171}$Yb$^+$ ion. For the spectroscopy of this strongly forbidden transition, we utilize a Ramsey-type excitation scheme that provides immunity to probe-induced frequency shifts. The cancellation of these shifts is controlled by interleaved single-pulse Rabi spectroscopy which reduces the related relative frequency uncertainty to $1.1\times 10^{-18}$. To determine the frequency shift due to thermal radiation emitted by the ion's environment, we measure the static scalar differential polarizability of the \textit{E}3 transition as $0.888(16)\times 10^{-40}$ J m$^2$/V$^2$ and a dynamic correction $η(300~\text{K})=-0.0015(7)$. This reduces the uncertainty due to thermal radiation to $1.8\times 10^{-18}$. The residual motion of the ion yields the largest contribution $(2.1\times 10^{-18})$ to the total systematic relative uncertainty of the clock of $3.2\times 10^{-18}$.
△ Less
Submitted 11 February, 2016;
originally announced February 2016.
-
Analysis of thermal radiation in ion traps for optical frequency standards
Authors:
Miroslav Doležal,
Petr Balling,
Peter B R Nisbet-Jones,
Steven A King,
Jonathan M Jones,
Hugh A Klein,
Patrick Gill,
Thomas Lindvall,
Anders E Wallin,
Mikko Merimaa,
Christian Tamm,
Christian Sanner,
Nils Huntemann,
Nils Scharnhorst,
Ian D Leroux,
Piet O Schmidt,
Tobias Burgermeister,
Tanja E Mehlstäubler,
Ekkehard Peik
Abstract:
In many of the high-precision optical frequency standards with trapped atoms or ions that are under development to date, the AC Stark shift induced by thermal radiation leads to a major contribution to the systematic uncertainty. We present an analysis of the inhomogeneous thermal environment experienced by ions in various types of ion traps. Finite element models which allow the determination of…
▽ More
In many of the high-precision optical frequency standards with trapped atoms or ions that are under development to date, the AC Stark shift induced by thermal radiation leads to a major contribution to the systematic uncertainty. We present an analysis of the inhomogeneous thermal environment experienced by ions in various types of ion traps. Finite element models which allow the determination of the temperature of the trap structure and the temperature of the radiation were developed for 5 ion trap designs, including operational traps at PTB and NPL and further optimized designs. Models were refined based on comparison with infrared camera measurement until an agreement of better than 10% of the measured temperature rise at critical test points was reached. The effective temperature rises of the radiation seen by the ion range from 0.8 K to 2.1 K at standard working conditions. The corresponding fractional frequency shift uncertainties resulting from the uncertainty in temperature are in the 10-18 range for optical clocks based on the Sr+ and Yb+ E2 transitions, and even lower for Yb+ E3, In+ and Al+. Issues critical for heating of the trap structure and its predictability were identified and design recommendations developed.
△ Less
Submitted 6 November, 2015; v1 submitted 19 October, 2015;
originally announced October 2015.
-
Frequency comparison of ${}^{171}$Yb${}^+$ ion optical clocks at PTB and NPL via GPS PPP
Authors:
J. Leute,
N. Huntemann,
B. Lipphardt,
Chr. Tamm,
P. B. R. Nisbet-Jones,
S. A. King,
R. M. Godun,
J. M. Jones,
H. S. Margolis,
P. B. Whibberley,
A. Wallin,
M. Merimaa,
P. Gill,
E. Peik
Abstract:
We used Precise Point Positioning, a well-established GPS carrier-phase frequency transfer method to perform a direct remote comparison of two optical frequency standards based on single laser-cooled $^{171}$Yb$^+$ ions operated at NPL, UK and PTB, Germany. At both institutes an active hydrogen maser serves as a flywheel oscillator; it is connected to a GPS receiver as an external frequency refere…
▽ More
We used Precise Point Positioning, a well-established GPS carrier-phase frequency transfer method to perform a direct remote comparison of two optical frequency standards based on single laser-cooled $^{171}$Yb$^+$ ions operated at NPL, UK and PTB, Germany. At both institutes an active hydrogen maser serves as a flywheel oscillator; it is connected to a GPS receiver as an external frequency reference and compared simultaneously to a realization of the unperturbed frequency of the ${{}^2S_{1/2}(F=0)-{}^2D_{3/2}(F=2)}$ electric quadrupole transition in ${}^{171}$Yb${}^+$ via an optical femtosecond frequency comb. To profit from long coherent GPS link measurements we extrapolate over the various data gaps in the optical clock to maser comparisons which introduces maser noise to the frequency comparison but improves the uncertainty from the GPS link. We determined the total statistical uncertainty consisting of the GPS link uncertainty and the extrapolation uncertainties for several extrapolation schemes. Using the extrapolation scheme with the smallest combined uncertainty, we find a fractional frequency difference $y(\mathrm{PTB})-y(\mathrm{NPL})$ of $-1.3(1.2)\times 10^{-15}$ for a total measurement time of 67 h. This result is consistent with an agreement of both optical clocks and with recent absolute frequency measurements against caesium fountain clocks.
△ Less
Submitted 15 July, 2015;
originally announced July 2015.
-
Improved limit on a temporal variation of $m_p/m_e$ from comparisons of Yb$^+$ and Cs atomic clocks
Authors:
N. Huntemann,
B. Lipphardt,
Chr. Tamm,
V. Gerginov,
S. Weyers,
E. Peik
Abstract:
Accurate measurements of different transition frequencies between atomic levels of the electronic and hyperfine structure over time are used to investigate temporal variations of the fine structure constant $α$ and the proton-to-electron mass ratio $μ$. We measure the frequency of the $^2S_{1/2}\rightarrow {^2F_{7/2}}$ electric octupole (E3) transition in $^{171}$Yb$^+$ against two caesium fountai…
▽ More
Accurate measurements of different transition frequencies between atomic levels of the electronic and hyperfine structure over time are used to investigate temporal variations of the fine structure constant $α$ and the proton-to-electron mass ratio $μ$. We measure the frequency of the $^2S_{1/2}\rightarrow {^2F_{7/2}}$ electric octupole (E3) transition in $^{171}$Yb$^+$ against two caesium fountain clocks as $f(E3) = 642\,121\,496\,772\,645.36(25)$~Hz with an improved fractional uncertainty of $3.9\times 10^{-16}$. This transition frequency shows a strong sensitivity to changes of $α$. Together with a number of previous and recent measurements of the $^2S_{1/2}\rightarrow {^2D_{3/2}}$ electric quadrupole transition in $^{171}$Yb$^+$ and with data from other elements, a least-squares analysis yields $(1/α)(dα/dt)=-0.20(20)\times 10^{-16}/\mathrm{yr}$ and $(1/μ)(dμ/dt)=-0.5(1.6)\times 10^{-16}/\mathrm{yr}$, confirming a previous limit on $dα/dt$ and providing the most stringent limit on $d μ/dt$ from laboratory experiments.
△ Less
Submitted 16 July, 2014;
originally announced July 2014.
-
A Cs-Based Optical Frequency Measurement Using Cross-Linked Optical and Microwave Oscillators
Authors:
Chr. Tamm,
N. Huntemann,
B. Lipphardt,
V. Gerginov,
N. Nemitz,
M. Kazda,
S. Weyers,
E. Peik
Abstract:
We describe a measurement of the frequency of the 2S1/2(F = 0) - 2D3/2(F' = 2) transition of 171Yb+ at the wavelength 436 nm (frequency 688 THz), using a single Yb+ ion confined in a Paul trap and two caesium fountains as references. In one of the fountains, the frequency of the microwave oscillator that interrogates the caesium atoms is stabilized by the laser that excites the Yb+ reference trans…
▽ More
We describe a measurement of the frequency of the 2S1/2(F = 0) - 2D3/2(F' = 2) transition of 171Yb+ at the wavelength 436 nm (frequency 688 THz), using a single Yb+ ion confined in a Paul trap and two caesium fountains as references. In one of the fountains, the frequency of the microwave oscillator that interrogates the caesium atoms is stabilized by the laser that excites the Yb+ reference transition with a linewidth in the hertz range. The stability is transferred to the microwave oscillator with the use of a fiber laser based optical frequency comb generator that also provides the frequency conversion for the absolute frequency measurement. The frequency comb generator is configured as a transfer oscillator so that fluctuations of the pulse repetition rate and of the carrier offset frequency do not degrade the stability of the frequency conversion. The phase noise level of the generated ultrastable microwave signal is comparable to that of a cryogenic sapphire oscillator. For fountain operation with optical molasses loaded from a laser cooled atomic beam source, we obtain a stability corresponding to a fractional Allan deviation of $4.1\times 10^{-14}\ (τ/\text{s})^{-1/2}$. With the molasses loaded from thermal vapor and an averaging time of 65 h, we measure the frequency of the Yb+ transition with a relative statistical uncertainty of $2.8\times10^{-16}$ and a systematic uncertainty of $5.9\times10^{-16}$. The frequency was also simultaneously measured with the second fountain that uses a quartz-based interrogation oscillator. The unperturbed frequency of the Yb+ transition is realized with an uncertainty of $1.1\times10^{-16}$ that mainly results from the uncertainty of the blackbody shift at the operating temperature near 300 K. The transition frequency of 688 358 979 309 307.82(36) Hz, measured with the two fountains, is in good agreement with previous results.
△ Less
Submitted 30 October, 2013;
originally announced October 2013.
-
A generalized Ramsey excitation scheme with suppressed light shift
Authors:
N. Huntemann,
B. Lipphardt,
M. Okhapkin,
Chr. Tamm,
E. Peik,
A. V. Taichenachev,
V. I. Yudin
Abstract:
We experimentally investigate a recently proposed optical excitation scheme [V.I. Yudin et al., Phys. Rev. A 82, 011804(R)(2010)] that is a generalization of Ramsey's method of separated oscillatory fields and consists of a sequence of three excitation pulses. The pulse sequence is tailored to produce a resonance signal which is immune to the light shift and other shifts of the transition frequenc…
▽ More
We experimentally investigate a recently proposed optical excitation scheme [V.I. Yudin et al., Phys. Rev. A 82, 011804(R)(2010)] that is a generalization of Ramsey's method of separated oscillatory fields and consists of a sequence of three excitation pulses. The pulse sequence is tailored to produce a resonance signal which is immune to the light shift and other shifts of the transition frequency that are correlated with the interaction with the probe field. We investigate the scheme using a single trapped 171Yb+ ion and excite the highly forbidden 2S1/2-2F7/2 electric-octupole transition under conditions where the light shift is much larger than the excitation linewidth, which is in the Hertz range. The experiments demonstrate a suppression of the light shift by four orders of magnitude and an immunity against its fluctuations.
△ Less
Submitted 26 November, 2012; v1 submitted 10 September, 2012;
originally announced September 2012.
-
Two-photon laser excitation of trapped 232Th+ ions via the 402 nm resonance line
Authors:
O. A. Herrera-Sancho,
M. V. Okhapkin,
K. Zimmermann,
Chr. Tamm,
E. Peik,
A. V. Taichenachev,
V. I. Yudin,
P. Glowacki
Abstract:
Experiments on one- and two-photon laser excitation of 232Th+ ions in a radiofrequency ion trap are reported. As the first excitation step, the strongest resonance line at 402 nm from the 6d^2 7s J=3/2 ground state to the 6d7s7p J=5/2 state at 24874 cm^{-1} is driven by radiation from an extended cavity diode laser. Spontaneous decay of the intermediate state populates a number of low-lying metast…
▽ More
Experiments on one- and two-photon laser excitation of 232Th+ ions in a radiofrequency ion trap are reported. As the first excitation step, the strongest resonance line at 402 nm from the 6d^2 7s J=3/2 ground state to the 6d7s7p J=5/2 state at 24874 cm^{-1} is driven by radiation from an extended cavity diode laser. Spontaneous decay of the intermediate state populates a number of low-lying metastable states, thus limiting the excited state population and fluorescence signal obtainable with continuous laser excitation. We study the collisional quenching efficiency of helium, argon, and nitrogen buffer gases, and the effect of repum** laser excitation from the three lowest-lying metastable levels. The experimental results are compared with a four-level rate equation model, that allows us to deduce quenching rates for these buffer gases. Using laser radiation at 399 nm for the second step, we demonstrate two-photon excitation to the state at 49960 cm^{-1}, among the highest-lying classified levels of Th+. This is of interest as a test case for the search for higher-lying levels in the range above 55000 cm^{-1} which can resonantly enhance the excitation of the 229Th+ nuclear resonance through an inverse two-photon electronic bridge process.
△ Less
Submitted 1 February, 2012;
originally announced February 2012.
-
High-accuracy optical clock based on the octupole transition in 171Yb+
Authors:
N. Huntemann,
M. Okhapkin,
B. Lipphardt,
S. Weyers,
Chr. Tamm,
E. Peik
Abstract:
We experimentally investigate an optical frequency standard based on the 467 nm (642 THz) electric-octupole reference transition 2S1/2(F=0) -> F7/2(F=3) in a single trapped 171Yb+ ion. The extraordinary features of this transition result from the long natural lifetime and from the 4f136s2 configuration of the upper state. The electric quadrupole moment of the 2F7/2 state is measured as -0.041(5) e…
▽ More
We experimentally investigate an optical frequency standard based on the 467 nm (642 THz) electric-octupole reference transition 2S1/2(F=0) -> F7/2(F=3) in a single trapped 171Yb+ ion. The extraordinary features of this transition result from the long natural lifetime and from the 4f136s2 configuration of the upper state. The electric quadrupole moment of the 2F7/2 state is measured as -0.041(5) e(a0)^2, where e is the elementary charge and a0 the Bohr radius. We also obtain information on the differential scalar and tensorial components of the static polarizability and of the probe light induced ac Stark shift of the octupole transition. With a real-time extrapolation scheme that eliminates this shift, the unperturbed transition frequency is realized with a fractional uncertainty of 7.1x10^(-17). The frequency is measured as 642 121 496 772 645.15(52) Hz.
△ Less
Submitted 1 March, 2012; v1 submitted 10 November, 2011;
originally announced November 2011.
-
Atomic clocks with suppressed blackbody radiation shift
Authors:
V. I. Yudin,
A. V. Taichenachev,
M. V. Okhapkin,
S. N. Bagayev,
Chr. Tamm,
E. Peik,
N. Huntemann,
T. E. Mehlstaubler,
F. Riehle
Abstract:
We develop a nonstandard concept of atomic clocks where the blackbody radiation shift (BBRS) and its temperature fluctuations can be dramatically suppressed (by one to three orders of magnitude) independent of the environmental temperature. The suppression is based on the fact that in a system with two accessible clock transitions (with frequencies v1 and v2) which are exposed to the same thermal…
▽ More
We develop a nonstandard concept of atomic clocks where the blackbody radiation shift (BBRS) and its temperature fluctuations can be dramatically suppressed (by one to three orders of magnitude) independent of the environmental temperature. The suppression is based on the fact that in a system with two accessible clock transitions (with frequencies v1 and v2) which are exposed to the same thermal environment, there exists a "synthetic" frequency v_{syn} (v1-e12 v2) largely immune to the BBRS. As an example, it is shown that in the case of ion 171Yb+ it is possible to create a clock in which the BBRS can be suppressed to the fractional level of 10^{-18} in a broad interval near room temperature (300\pm 15 K). We also propose a realization of our method with the use of an optical frequency comb generator stabilized to both frequencies v1 and v2. Here the frequency v_{syn} is generated as one of the components of the comb spectrum and can be used as an atomic standard.
△ Less
Submitted 5 March, 2011; v1 submitted 3 March, 2011;
originally announced March 2011.
-
Excitation of the isomeric ^{229m}Th nuclear state via an electronic bridge process in ^{229}Th^+
Authors:
S. G. Porsev,
V. V. Flambaum,
E. Peik,
Chr. Tamm
Abstract:
We consider the excitation of the nuclear transition ^{229g}Th - ^{229m}Th near 7.6 eV in singly ionized thorium via an electronic bridge process. The process relies on the excitation of the electron shell by two laser photons whose sum frequency is equal to the nuclear transition frequency. This scheme allows to determine the nuclear transition frequency with high accuracy. Based on calculations…
▽ More
We consider the excitation of the nuclear transition ^{229g}Th - ^{229m}Th near 7.6 eV in singly ionized thorium via an electronic bridge process. The process relies on the excitation of the electron shell by two laser photons whose sum frequency is equal to the nuclear transition frequency. This scheme allows to determine the nuclear transition frequency with high accuracy. Based on calculations of the electronic level structure of Th^+ which combine the configuration-interaction method and many-body perturbation theory, we estimate that a nuclear excitation rate in the range of 10 s^{-1} can be obtained using conventional laser sources.
△ Less
Submitted 16 June, 2010;
originally announced June 2010.
-
Prospects for a Nuclear Optical Frequency Standard based on Thorium-229
Authors:
E. Peik,
K. Zimmermann,
M. Okhapkin,
Chr. Tamm
Abstract:
The 7.6-eV-isomer of Thorium-229 offers the opportunity to perform high resolution laser spectroscopy of a nuclear transition. We give a brief review of the investigations of this isomer. The nuclear resonance connecting ground state and isomer may be used as the reference of an optical clock of very high accuracy using trapped and laser-cooled thorium ions, or in a compact solid-state optical f…
▽ More
The 7.6-eV-isomer of Thorium-229 offers the opportunity to perform high resolution laser spectroscopy of a nuclear transition. We give a brief review of the investigations of this isomer. The nuclear resonance connecting ground state and isomer may be used as the reference of an optical clock of very high accuracy using trapped and laser-cooled thorium ions, or in a compact solid-state optical frequency standard of high stability.
△ Less
Submitted 3 February, 2009; v1 submitted 18 December, 2008;
originally announced December 2008.
-
The stability of an optical clock laser transferred to the interrogation oscillator for a Cs fountain
Authors:
B. Lipphardt,
G. Grosche,
U. Sterr,
Chr. Tamm,
S. Weyers,
H. Schnatz
Abstract:
We stabilise a microwave oscillator at 9.6 GHz to an optical clock laser at 344 THz by using a fibre-based femtosecond laser frequency comb as a transfer oscillator. With a second frequency comb we measure independently the instability of the microwave source with respect to another optical clock laser frequency at 456 THz. The total fractional frequency instability of this optic-to-microwave an…
▽ More
We stabilise a microwave oscillator at 9.6 GHz to an optical clock laser at 344 THz by using a fibre-based femtosecond laser frequency comb as a transfer oscillator. With a second frequency comb we measure independently the instability of the microwave source with respect to another optical clock laser frequency at 456 THz. The total fractional frequency instability of this optic-to-microwave and microwave-to-optic conversion resulted in an Allan deviation sigma_y, of sigma_y=1.2E-14 at 1 s averaging time (band width 50 kHz). The residual phase noise density is -97 dBc/Hz at 10 Hz offset from the 9.6 GHz carrier. Replacing the existing quartz-based interrogation oscillator of the PTB caesium fountain CSF1 with this optically stabilised microwave source will reduce the instability contribution due to the Dick effect from the 1E-13-level at 1s averaging time to an insignificant level at the current status of CSF1. Therefore this new microwave source can be an alternative to cryogenic sapphire-loaded cavity oscillators in order to overcome the limitations of state-of-the-art quartz oscillators.
△ Less
Submitted 12 September, 2008;
originally announced September 2008.
-
Laboratory Limits on Temporal Variations of Fundamental Constants: An Update
Authors:
E. Peik,
B. Lipphardt,
H. Schnatz,
Chr. Tamm,
S. Weyers,
R. Wynands
Abstract:
Precision comparisons of different atomic frequency standards over a period of a few years can be used for a sensitive search for temporal variations of fundamental constants. We present recent frequency measurements of the 688 THz transition in the $^{171}$Yb$^+$ ion. For this transition frequency a record over six years is now available, showing that a possible frequency drift relative to a ce…
▽ More
Precision comparisons of different atomic frequency standards over a period of a few years can be used for a sensitive search for temporal variations of fundamental constants. We present recent frequency measurements of the 688 THz transition in the $^{171}$Yb$^+$ ion. For this transition frequency a record over six years is now available, showing that a possible frequency drift relative to a cesium clock can be constrained to $(-0.54\pm0.97)$ Hz/yr, i.e. at the level of $2\cdot10^{-15}$ per year. Combined with precision frequency measurements of an optical frequency in $^{199}$Hg$^+$ and of the hyperfine ground state splitting in $^{87}$Rb a stringent limit on temporal variations of the fine structure constant $α$: $d\lnα/dt= (-0.26\pm0.39)\cdot 10^{-15} {\rm yr}^{-1}$ and a model-dependent limit for variations of the proton-to-electron mass ratio $μ$ in the present epoch can be derived: $d \ln μ/dt = (-1.2 \pm 2.2)\cdot 10^{-15} {\rm yr}^{-1}$. We discuss these results in the context of astrophysical observations that apparently indicate changes in both of these constants over the last 5--10 billion years.
△ Less
Submitted 9 November, 2006;
originally announced November 2006.
-
Laser frequency stabilization to a single ion
Authors:
Ekkehard Peik,
Tobias Schneider,
Christian Tamm
Abstract:
A fundamental limit to the stability of a single-ion optical frequency standard is set by quantum noise in the measurement of the internal state of the ion. We discuss how the interrogation sequence and the processing of the atomic resonance signal can be optimized in order to obtain the highest possible stability under realistic experimental conditions. A servo algorithm is presented that stabi…
▽ More
A fundamental limit to the stability of a single-ion optical frequency standard is set by quantum noise in the measurement of the internal state of the ion. We discuss how the interrogation sequence and the processing of the atomic resonance signal can be optimized in order to obtain the highest possible stability under realistic experimental conditions. A servo algorithm is presented that stabilizes a laser frequency to the single-ion signal and that eliminates errors due to laser frequency drift. Numerical simulations of the servo characteristics are compared to experimental data from a frequency comparison of two single-ion standards based on a transition at 688 THz in 171Yb+. Experimentally, an instability sigma_y(100 s)=9*10^{-16} is obtained in the frequency difference between both standards.
△ Less
Submitted 18 November, 2005;
originally announced November 2005.
-
Frequency comparisons and absolute frequency measurements of 171Yb+ single-ion optical frequency standards
Authors:
E. Peik,
B. Lipphardt,
H. Schnatz,
T. Schneider,
Chr. Tamm,
S. G. Karshenboim
Abstract:
We describe experiments with an optical frequency standard based on a laser cooled $^{171}$Yb$^+$ ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the $^2S_{1/2}(F=0)$ ground state to the $^2D_{3/2}(F=2)$ state at the wavelength of 436 nm is used as the reference transition. In order to compare two $^{171}$Yb$^+$ standards, separate frequency servo systems are…
▽ More
We describe experiments with an optical frequency standard based on a laser cooled $^{171}$Yb$^+$ ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the $^2S_{1/2}(F=0)$ ground state to the $^2D_{3/2}(F=2)$ state at the wavelength of 436 nm is used as the reference transition. In order to compare two $^{171}$Yb$^+$ standards, separate frequency servo systems are employed to stabilize two probe laser frequencies to the reference transition line centers of two independently stored ions. The experimental results indicate a relative instability (Allan standard deviation) of the optical frequency difference between the two systems of $σ_y(1000 {\rm s})=5\cdot 10^{-16}$ only, so that shifts in the sub-hertz range can be resolved. Shifts of several hertz are observed if a stationary electric field gradient is superimposed on the radiofrequency trap field. The absolute optical transition frequency of Yb$^+$ at 688 THz was measured with a cesium atomic clock at two times separated by 2.8 years. A temporal variation of this frequency can be excluded within a $1σ$ relative uncertainty of $4.4\cdot 10^{-15}$ yr$^{-1}$. Combined with recently published values for the constancy of other transition frequencies this measurement provides a limit on the present variability of the fine structure constant $α$ at the level of $2.0\cdot 10^{-15}$ yr$^{-1}$.
△ Less
Submitted 14 April, 2005;
originally announced April 2005.
-
New limit on the present temporal variation of the fine structure constant
Authors:
E. Peik,
B. Lipphardt,
H. Schnatz,
T. Schneider,
Chr. Tamm,
S. G. Karshenboim
Abstract:
The comparison of different atomic transition frequencies over time can be used to determine the present value of the temporal derivative of the fine structure constant alpha in a model-independent way without assumptions on constancy or variability of other parameters. We have measured an optical transition frequency at 688 THz in ^{171}Yb+ with a cesium atomic clock at two times separated by 2…
▽ More
The comparison of different atomic transition frequencies over time can be used to determine the present value of the temporal derivative of the fine structure constant alpha in a model-independent way without assumptions on constancy or variability of other parameters. We have measured an optical transition frequency at 688 THz in ^{171}Yb+ with a cesium atomic clock at two times separated by 2.8 years and find a value for the fractional variation of the frequency ratio $f_{\rm Yb}/f_{\rm Cs}$ of $(-1.2\pm 4.4)\cdot 10^{-15}$ yr$^{-1}$, consistent with zero. Combined with recently published values for the constancy of other transition frequencies this measurement sets an upper limit on the present variability of alpha at the level of $2.0\cdot 10^{-15}$ yr$^{-1}$, corresponding so far to the most stringent limit from laboratory experiments.
△ Less
Submitted 28 October, 2004; v1 submitted 27 February, 2004;
originally announced February 2004.
-
Comparison of two single-ion optical frequency standards at the sub-Hertz level
Authors:
Chr. Tamm,
T. Schneider,
E. Peik
Abstract:
We describe experimental investigations on an optical frequency standard based on a laser cooled 171Yb+ ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the 2S1/2(F=0) ground state to the 2D3/2(F=2) state at the wavelength of 436 nm is used as the reference transition. The reference transition is probed by a frequency-doubled, frequency-stabilized diode laser a…
▽ More
We describe experimental investigations on an optical frequency standard based on a laser cooled 171Yb+ ion confined in a radiofrequency Paul trap. The electric-quadrupole transition from the 2S1/2(F=0) ground state to the 2D3/2(F=2) state at the wavelength of 436 nm is used as the reference transition. The reference transition is probed by a frequency-doubled, frequency-stabilized diode laser and is resolved with a Fourier-limited full halfwidth of approximately 30 Hz. In order to compare two 171Yb+ standards, separate frequency shift and servo systems are employed to stabilise the probe frequency to the reference transition line centers of two independently stored 171Yb+ ions. The present experimental results indicate a relative instability (Allan standard deviation)of the optical frequency difference between the two systems of sigma_y(1000 s)=1.0E-15 and a mean frequency difference of 0.2 Hz. Shifts in the range of several Hertz are observed in the frequency difference if a stationary electric field gradient is superimposed on the radiofrequency trap field. This measurement permits a first experimental estimate of the electric quadrupole moment of the 2D3/2 state of Yb+.
△ Less
Submitted 25 February, 2004;
originally announced February 2004.
-
Ultra-precise measurement of optical frequency ratios
Authors:
Jörn Stenger,
Harald Schnatz,
Christian Tamm,
Harald R. Telle
Abstract:
We developed a novel technique for frequency measurement and synthesis, based on the operation of a femtosecond comb generator as transfer oscillator. The technique can be used to measure frequency ratios of any optical signals throughout the visible and near-infrared part of the spectrum. Relative uncertainties of $10^{-18}$ for averaging times of 100 s are possible. Using a Nd:YAG laser in com…
▽ More
We developed a novel technique for frequency measurement and synthesis, based on the operation of a femtosecond comb generator as transfer oscillator. The technique can be used to measure frequency ratios of any optical signals throughout the visible and near-infrared part of the spectrum. Relative uncertainties of $10^{-18}$ for averaging times of 100 s are possible. Using a Nd:YAG laser in combination with a nonlinear crystal we measured the frequency ratio of the second harmonic $ν_{SH}$ at 532 nm to the fundamental $ν_0$ at 1064 nm, $ν_{SH}/ν_0 = 2.000 000 000 000 000 001 \times (1 \pm 7 \times 10^{-19})$.
△ Less
Submitted 24 September, 2001; v1 submitted 29 August, 2001;
originally announced August 2001.
-
Absolute frequency measurement of the 171Yb+ clock transition with a Kerr-lens mode-locked femtosecond laser
Authors:
Joern Stenger,
Christian Tamm,
Nils Haverkamp,
Stefan Weyers,
Harald R. Telle
Abstract:
We have measured the frequency of the $6s^2S_{1/2} - 5d^2D_{3/2}$ electric-quadrupole transition of $^{171}$Yb$^+$ with a relative uncertainty of $1\times 10^{-14}$, $ν_{Yb}$ = 688 358 979 309 312 Hz $\pm$ 6 Hz. A femtosecond frequency comb generator was used to phase-coherently link the optical frequency derived from a single trapped ion to a cesium fountain controlled hydrogen maser. This meas…
▽ More
We have measured the frequency of the $6s^2S_{1/2} - 5d^2D_{3/2}$ electric-quadrupole transition of $^{171}$Yb$^+$ with a relative uncertainty of $1\times 10^{-14}$, $ν_{Yb}$ = 688 358 979 309 312 Hz $\pm$ 6 Hz. A femtosecond frequency comb generator was used to phase-coherently link the optical frequency derived from a single trapped ion to a cesium fountain controlled hydrogen maser. This measurement is one of the most accurate measurements of optical frequencies ever reported, and it represents a contribution to the development of optical clocks based on an $^{171}$Yb$^+$ ion standard.
△ Less
Submitted 19 March, 2001; v1 submitted 14 March, 2001;
originally announced March 2001.