-
Development of a low-background micro pixel chamber for directional dark matter searches
Authors:
Ryota Namai,
Satoshi Higashino,
Hirohisa Ishiura,
Tomonori Ikeda,
Mizuno Ofuji,
Ayaka Nakayama,
Kiseki Nakamura,
Hiroshi Ito,
Koichi Ichimura,
Ko Abe,
Kazuyoshi Kobayashi,
Atsushi Takada,
Ryo Kubota,
Kentaro Miuchi
Abstract:
Direct detection of weakly interacting massive particles (WIMPs) can provide strong evidence of their existence and the directional method would have an advantage over other methods to detect the clear signal of WIMPs. Time projection chambers with micro-patterned gaseous detectors (MPGDs) are one of the common devices used in directional WIMP searches. A micro pixel chamber ($μ$-PIC), one of the…
▽ More
Direct detection of weakly interacting massive particles (WIMPs) can provide strong evidence of their existence and the directional method would have an advantage over other methods to detect the clear signal of WIMPs. Time projection chambers with micro-patterned gaseous detectors (MPGDs) are one of the common devices used in directional WIMP searches. A micro pixel chamber ($μ$-PIC), one of the various types of MPGDs, with specially selected low background materials (LBG$μ$-PIC) was developed and its performance was studied. The radon emission of the LBG$μ$-PIC was less than 1/60 of that of the $μ$-PIC currently in use. Although a non-negligible gain non-homogeneity was seen for the LBG$μ$-PIC, it can be used for the directional WIMP search with the correction of the non-homogeneity.
△ Less
Submitted 18 March, 2024;
originally announced March 2024.
-
High-energy extension of the gamma-ray band observable with an electron-tracking Compton camera
Authors:
Tomohiko Oka,
Shingo Ogio,
Mitsuru Abe,
Kenji Hamaguchi,
Tomonori Ikeda,
Hidetoshi Kubo,
Shunsuke Kurosawa,
Kentaro Miuchi,
Yoshitaka Mizumura,
Yuta Nakamura,
Tatsuya Sawano,
Atsushi Takada,
Taito Takemura,
Toru Tanimori,
Kei Yoshikawa
Abstract:
Although the MeV gamma-ray band is a promising energy-band window in astrophysics, the current situation of MeV gamma-ray astronomy significantly lags behind those of the other energy bands in angular resolution and sensitivity. An electron-tracking Compton camera (ETCC), a next-generation MeV detector, is expected to revolutionize the situation. An ETCC tracks each Compton-recoil electron with a…
▽ More
Although the MeV gamma-ray band is a promising energy-band window in astrophysics, the current situation of MeV gamma-ray astronomy significantly lags behind those of the other energy bands in angular resolution and sensitivity. An electron-tracking Compton camera (ETCC), a next-generation MeV detector, is expected to revolutionize the situation. An ETCC tracks each Compton-recoil electron with a gaseous electron tracker and determines the incoming direction of each gamma-ray photon; thus, it has a strong background rejection power and yields a better angular resolution than classical Compton cameras. Here, we study ETCC events in which the Compton-recoil electrons do not deposit all energies to the electron tracker but escape and hit the surrounding pixel scintillator array (PSA). We developed an analysis method for this untapped class of events and applied it to laboratory and simulation data. We found that the energy spectrum obtained from the simulation agreed with that of the actual data within a factor of 1.2. We then evaluated the detector performance using the simulation data. The angular resolution for the new-class events was found to be twice as good as in the previous study at the energy range 1.0--2.0~MeV, where both analyses overlap. We also found that the total effective area is dominated by the contribution of the double-hit events above an energy of 1.5~MeV. Notably, applying this new method extends the sensitive energy range with the ETCC from 0.2--2.1 MeV in the previous studies to up to 3.5~MeV. Adjusting the PSA dynamic range should improve the sensitivity in even higher energy gamma-rays. The development of this new analysis method would pave the way for future observations by ETCC to fill the MeV-band sensitivity gap in astronomy.
△ Less
Submitted 8 March, 2024;
originally announced March 2024.
-
Direction-sensitive dark matter search with a low-background gaseous detector NEWAGE-0.3b''
Authors:
Tomonori Ikeda,
Kiseki Nakamura,
Takuya Shimada,
Ryota Yakabe,
Takashi Hashimoto,
Hirohisa Ishiura,
Takuma Nakamura,
Hiroshi Ito,
Koichi Ichimura,
Ko Abe,
Kazuyoshi Kobayashi,
Toru Tanimori,
Hidetoshi Kubo,
Atsushi Takada,
Hiroyuki Sekiya,
Atsushi Takeda,
Kentaro Miuchi
Abstract:
NEWAGE is a direction-sensitive dark matter search using a low-pressure gaseous time projection chamber. A low alpha-ray emission rate micro pixel chamber had been developed in order to reduce background for dark matter search. We conducted the dark matter search at the Kamioka Observatory in 2018. The total live time was 107.6 days corresponding to an exposure of 1.1 kg${\cdot}$days. Two events r…
▽ More
NEWAGE is a direction-sensitive dark matter search using a low-pressure gaseous time projection chamber. A low alpha-ray emission rate micro pixel chamber had been developed in order to reduce background for dark matter search. We conducted the dark matter search at the Kamioka Observatory in 2018. The total live time was 107.6 days corresponding to an exposure of 1.1 kg${\cdot}$days. Two events remained in the energy region of 50-60 keV which was consistent with 2.5 events of the expected background. A directional analysis was carried out and no significant forward-backward asymmetry derived from the WIMP-nucleus elastic scatterings was found. Thus a 90% confidence level upper limit on Spin-Dependent WIMP-proton cross section of 50 pb for a WIMP mass of 100 GeV/c2 was derived. This limit is the most stringent yet obtained from direction-sensitive dark matter search experiments.
△ Less
Submitted 7 April, 2021; v1 submitted 25 January, 2021;
originally announced January 2021.
-
First limits from a 3d-vector directional dark matter search with the NEWAGE-0.3b' detector
Authors:
Ryota Yakabe,
Kiseki Nakamura,
Tomonori Ikeda,
Hiroshi Ito,
Yushiro Yamaguchi,
Ryosuke Taishaku,
Miki Nakazawa,
Hirohisa Ishiura,
Takuma Nakamura,
Takuya Shimada,
Toru Tanimori,
Hidetoshi Kubo,
Atsushi Takada,
Hiroyuki Sekiya,
Atsushi Takeda,
Kentaro Miuchi
Abstract:
The first directional dark matter search with three-dimensional tracking with head-tail sensitivity (3d-vector tracking analysis) was performed with a gaseous three-dimensional tarcking detector, or the NEWAGE-0.3b' detector. The search was carried out from July 2013 to August 2017 (Run14 to Run18) at the Kamioka underground laboratory. The total livetime is 434.85 days corresponding to an exposur…
▽ More
The first directional dark matter search with three-dimensional tracking with head-tail sensitivity (3d-vector tracking analysis) was performed with a gaseous three-dimensional tarcking detector, or the NEWAGE-0.3b' detector. The search was carried out from July 2013 to August 2017 (Run14 to Run18) at the Kamioka underground laboratory. The total livetime is 434.85 days corresponding to an exposure of 4.51 kg$\cdot$days. A 90 % confidence level upper limit on spin-dependent WIMP-proton cross section of $4.3 \times10^{2}$ pb for WIMPs with the mass of 150 GeV/$c^2$ is obtained.
△ Less
Submitted 18 September, 2020; v1 submitted 11 May, 2020;
originally announced May 2020.
-
Development of a low-$α$-emitting $μ$-PIC as a readout device for direction-sensitive dark matter detectors
Authors:
Takashi Hashimoto,
Kentaro Miuchi,
Tomonori Ikeda,
Hirohisa Ishiura,
Kiseki D. Nakamura,
Hiroshi Ito,
Koichi Ichimura,
Ko Abe,
Kazuyoshi Kobayashi,
Atsushi Takada,
Atsuhiko Ochi,
Takuma Nakamura,
Takuya Shimada
Abstract:
Direction sensitivity could provide robust evidence for the direct detection of weakly interacting massive particles constituting dark matter. However, the sensitivity of this method remains low due to the radioactive backgrounds. The purpose of this study is to develop a low-background detector as a two-dimensional imaging device for a gaseous time projection chamber. In direction-sensitive dark…
▽ More
Direction sensitivity could provide robust evidence for the direct detection of weakly interacting massive particles constituting dark matter. However, the sensitivity of this method remains low due to the radioactive backgrounds. The purpose of this study is to develop a low-background detector as a two-dimensional imaging device for a gaseous time projection chamber. In direction-sensitive dark matter experiments~(e.g. NEWAGE), $α$-rays emitted from the detector components often create substantial radioactive backgrounds. Based on the study of the background of NEWAGE, a new detector "low-$α$ $μ$-PIC" is developed. The produced $μ$-PIC performs well as a gas detector and the $α$-ray emission rate from the $μ$-PIC reduced by a factor of 100.
△ Less
Submitted 28 June, 2020; v1 submitted 28 February, 2020;
originally announced February 2020.
-
Development of a time projection chamber with a sheet-resistor field cage
Authors:
Kentaro Miuchi,
Tomonori Ikeda,
Hirohisa Ishiura,
Kiseki D. Nakamura,
Atsushi Takada,
Yasuhiro Homma,
Ko Abe,
Koichi Ichimura,
Hiroshi Ito,
Kazuyoshi Kobayashi Takuma Nakamura,
Ryuichi Ueno,
Takuya Shimada,
Takashi Hashimoto,
Ryota Yakabe,
Atsuhiko Ochi
Abstract:
A new-concept time projection chamber (TPC) using a commercial resistive sheet, sheet-resistor micro-TPC SR-microPIC, was developed and its performance was measured. SR-microTPC has the potential to create a more uniform electric field than conventional TPCs with resistor-chains owing to its continuous sheet resistivity, and its production would be easier than that of conventional TPCs. The materi…
▽ More
A new-concept time projection chamber (TPC) using a commercial resistive sheet, sheet-resistor micro-TPC SR-microPIC, was developed and its performance was measured. SR-microTPC has the potential to create a more uniform electric field than conventional TPCs with resistor-chains owing to its continuous sheet resistivity, and its production would be easier than that of conventional TPCs. The material used in this study, Achilles-Vynilas, was found to be thin, transparent, and low-radioactive. The performance test with cosmic muons showed very promising results, including the demonstration of a good tracking-performance. This type of TPC field cage can offer an alternative for the widely used conventional field cages
△ Less
Submitted 9 April, 2019; v1 submitted 4 March, 2019;
originally announced March 2019.
-
Performance test of the MAIKo active target
Authors:
T. Furuno,
T. Kawabata,
H. J. Ong,
S. Adachi,
Y. Ayyad,
T. Baba,
Y. Fujikawa,
T. Hashimoto,
K. Inaba,
Y. Ishii,
S. Kabuki,
H. Kubo,
Y. Matsuda,
Y. Matsuoka,
T. Mizumoto,
T. Morimoto,
M. Murata,
T. Sawano,
T. Suzuki,
A. Takada,
J. Tanaka,
I. Tanihata,
T. Tanimori,
D. T. Tran,
M. Tsumura
, et al. (1 additional authors not shown)
Abstract:
A new active target named MAIKo (Mu-PIC based Active target for Inverse Kinematics$_{\circ}$) has been developed at Kyoto University and Research Center for Nuclear Physics (RCNP), Osaka University. MAIKo is suited for missing-mass spectroscopy of unstable nuclei at forward scattering angles in inverse kinematics. MAIKo consists of a time projection chamber (TPC), which incorporates a micro-pixel…
▽ More
A new active target named MAIKo (Mu-PIC based Active target for Inverse Kinematics$_{\circ}$) has been developed at Kyoto University and Research Center for Nuclear Physics (RCNP), Osaka University. MAIKo is suited for missing-mass spectroscopy of unstable nuclei at forward scattering angles in inverse kinematics. MAIKo consists of a time projection chamber (TPC), which incorporates a micro-pixel chamber ($μ$-PIC) as the electron multiplication and collection system. In MAIKo, the medium gas also plays the role of a reaction target, thus allowing detection of low-energy recoil particles with high position resolution. The MAIKo TPC was commissioned with He(93%)+iso-C$_{4}$H$_{10}$(7%) and He(93%)+CO$_{2}$(7%) mixture gasses at 430 hPa. The gas gain and the angular resolution of MAIKo were evaluated with an alpha source and a $^{4}$He beam at 56 MeV. The TPC was stably operated up to 1000-kcps beam intensity. A tracking algorithm using the Hough transform method has been developed to analyze scattering events. An angular resolution of 1.3$^{\circ}$ was achieved for scattered $^{4}$He particles.
△ Less
Submitted 6 September, 2018;
originally announced September 2018.
-
Development of energy-resolved neutron imaging detectors at RADEN
Authors:
Joseph Don Parker,
Masahide Harada,
Hirotoshi Hayashida,
Kosuke Hiroi,
Tetsuya Kai,
Yoshihiro Matsumoto,
Takeshi Nakatani,
Kenichi Oikawa,
Mariko Segawa,
Takenao Shinohara,
Yuhua Su,
Atsushi Takada,
Taito Takemura,
Tomoyuki Taniguchi,
Toru Tanimori,
Yoshiaki Kiyanagi
Abstract:
Energy-resolved neutron imaging at a pulsed source utilizes the energy-dependent neutron transmission measured via time-of-flight to extract quantitative information about the internal microstructure of an object. At the RADEN instrument at J-PARC in Japan, we use cutting-edge detectors employing micro-pattern detectors or fast Li-glass scintillators and fast, all-digital data acquisition to perfo…
▽ More
Energy-resolved neutron imaging at a pulsed source utilizes the energy-dependent neutron transmission measured via time-of-flight to extract quantitative information about the internal microstructure of an object. At the RADEN instrument at J-PARC in Japan, we use cutting-edge detectors employing micro-pattern detectors or fast Li-glass scintillators and fast, all-digital data acquisition to perform such measurements, while continuing their development toward better utilization of the intense neutron source. In particular, for the Micro-Pixel Chamber based Neutron Imaging Detector (μNID), a micro-pattern detector with a 400 μm pitch and employing 3He for neutron conversion, we have successfully improved the spatial resolution from 200 to 100 μm, increased the detection efficiency from 18 to 26% for thermal neutrons, and increased the maximum count rate from 0.4 to 1 Mcps. We are also testing a new readout element with a 215 μm pitch for further improved spatial resolution, and a μNID with boron-based neutron converter for increased rate performance.
△ Less
Submitted 25 June, 2018;
originally announced June 2018.
-
Study of Negative-Ion TPC Using μ-PIC for Directional Dark Matter Search
Authors:
Tomonori Ikeda,
Kentaro Miuchi,
Atsuhiko Ochi,
Ryota Yakabe,
Takashi Hashimoto,
Ryosuke Taishaku,
Daniel P. Snowden-Ifft,
Jean-Luc Gauvreau,
Toru Tanimori,
Atsushi Takada,
Kiseki Nakamura
Abstract:
Negative-ion time projection chambers(TPCs) have been studied for low-rate and high-resolution applications such as dark matter search experiments. Recently, a full volume fiducialization in a self-triggering TPC was realized. This innovative technology demonstrated a significant reduction in the background with MWPC-TPCs. We studied negative-ion TPC using the μ-PIC+GEM system and obtained suffici…
▽ More
Negative-ion time projection chambers(TPCs) have been studied for low-rate and high-resolution applications such as dark matter search experiments. Recently, a full volume fiducialization in a self-triggering TPC was realized. This innovative technology demonstrated a significant reduction in the background with MWPC-TPCs. We studied negative-ion TPC using the μ-PIC+GEM system and obtained sufficient gas gain with CS$_{2}$gas and SF$_{6}$ gas at low pressures. We expect an improvement in detector sensitivity and angular resolution with better electronics.
△ Less
Submitted 18 September, 2017;
originally announced September 2017.
-
First On-Site True Gamma-Ray Imaging-Spectroscopy of Contamination near Fukushima Plant
Authors:
Dai Tomono,
Tetsuya Mizumoto,
Atsushi Takada,
Shotaro Komura,
Yoshihiro Matsuoka,
Yoshitaka Mizumura,
Makoto Oda,
Toru Tanimori
Abstract:
We have developed an Electron Tracking Compton Camera (ETCC), which provides a well-defined Point Spread Function (PSF) by reconstructing a direction of each gamma as a point and realizes simultaneous measurement of brightness and spectrum of MeV gamma-rays for the first time. Here, we present the results of our on-site pilot gamma-imaging-spectroscopy with ETCC at three contaminated locations in…
▽ More
We have developed an Electron Tracking Compton Camera (ETCC), which provides a well-defined Point Spread Function (PSF) by reconstructing a direction of each gamma as a point and realizes simultaneous measurement of brightness and spectrum of MeV gamma-rays for the first time. Here, we present the results of our on-site pilot gamma-imaging-spectroscopy with ETCC at three contaminated locations in the vicinity of the Fukushima Daiichi Nuclear Power Plants in Japan in 2014. The obtained distribution of brightness (or emissivity) with remote-sensing observations is unambiguously converted into the dose distribution. We confirm that the dose distribution is consistent with the one taken by conventional map** measurements with a dosimeter physically placed at each grid point. Furthermore, its imaging spectroscopy, boosted by Compton-edge-free spectra, reveals complex radioactive features in a quantitative manner around each individual target point in the background-dominated environment. Notably, we successfully identify a "micro hot spot" of residual caesium contamination even in an already decontaminated area. These results show that the ETCC performs exactly as the geometrical optics predicts, demonstrates its versatility in the field radiation measurement, and reveals potentials for application in many fields, including the nuclear industry, medical field, and astronomy.
△ Less
Submitted 5 February, 2017;
originally announced February 2017.
-
Establishment of Imaging Spectroscopy of Nuclear Gamma-Rays based on Geometrical Optics
Authors:
Toru Tanimori,
Yoshitaka Mizumura,
Atsushi Takada,
Shohei Miyamoto,
Taito Takemura,
Tetsuro Kishimoto,
Shotaro Komura,
Hidetoshi Kubo,
Shunsuke Kurosawa,
Yoshihiro Matsuoka,
Kentaro Miuchi,
Tetsuya Mizumoto,
Yuma Nakamasu,
Kiseki Nakamura,
Joseph D. Parker,
Tatsuya Sawano,
Shinya Sonoda,
Dai Tomono,
Kei Yoshikawa
Abstract:
Since the discovery of nuclear gamma-rays, its imaging has been limited to pseudo imaging, such as Compton Camera (CC) and coded mask. Pseudo imaging does not keep physical information (intensity, or brightness in Optics) along a ray, and thus is capable of no more than qualitative imaging of bright objects. To attain quantitative imaging, cameras that realize geometrical optics is essential, whic…
▽ More
Since the discovery of nuclear gamma-rays, its imaging has been limited to pseudo imaging, such as Compton Camera (CC) and coded mask. Pseudo imaging does not keep physical information (intensity, or brightness in Optics) along a ray, and thus is capable of no more than qualitative imaging of bright objects. To attain quantitative imaging, cameras that realize geometrical optics is essential, which would be, for nuclear MeV gammas, only possible via complete reconstruction of the Compton process. Recently we have revealed that "Electron Tracking Compton Camera" (ETCC) provides a well-defined Point Spread Function (PSF). The information of an incoming gamma is kept along a ray with the PSF and that is equivalent to geometrical optics. Here we present an imaging-spectroscopic measurement with the ETCC. Our results highlight the intrinsic difficulty with CCs in performing accurate imaging, and show that the ETCC surmounts this problem. The imaging capability also helps the ETCC suppress the noise level dramatically by ~3 orders of magnitude without a shielding structure. Furthermore, full reconstruction of Compton process with the ETCC provides spectra free of Compton edges. These results mark the first proper imaging of nuclear gammas based on the genuine geometrical optics.
△ Less
Submitted 5 February, 2017;
originally announced February 2017.
-
Possibility of Systematic Study of Supernova Explosions by Nuclear Imaging Spectroscopy
Authors:
Yoshitaka Mizumura,
Toru Tanimori,
Atsushi Takada
Abstract:
An all-sky monitor with nuclear imaging spectroscopy is a promising tool for the systematic study of supernova explosions. In particular, progenitor scenarios of type-Ia supernovae, which are not yet well understood, can be resolved using light curves in the nuclear gamma-ray band. Here we report an expected result of an all-sky monitor with imaging spectroscopy using electron-tracking Compton cam…
▽ More
An all-sky monitor with nuclear imaging spectroscopy is a promising tool for the systematic study of supernova explosions. In particular, progenitor scenarios of type-Ia supernovae, which are not yet well understood, can be resolved using light curves in the nuclear gamma-ray band. Here we report an expected result of an all-sky monitor with imaging spectroscopy using electron-tracking Compton camera, which will enable us to observe nuclear gamma-ray lines from type-Ia supernovae.
△ Less
Submitted 21 October, 2016;
originally announced October 2016.
-
Readout technologies for directional WIMP Dark Matter detection
Authors:
J. B. R. Battat,
I. G. Irastorza,
A. Aleksandrov,
M. Ali Guler,
T. Asada,
E. Baracchini,
J. Billard,
G. Bosson,
O. Bourrion,
J. Bouvier,
A. Buonaura,
K. Burdge,
S. Cebrian,
P. Colas,
L. Consiglio,
T. Dafni,
N. D'Ambrosio,
C. Deaconu,
G. De Lellis,
T. Descombes,
A. Di Crescenzo,
N. Di Marco,
G. Druitt,
R. Eggleston,
E. Ferrer-Ribas
, et al. (68 additional authors not shown)
Abstract:
The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial…
▽ More
The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial resolution over large volumes, which puts strong requirements on the readout technologies. In this paper we review the various detector readout technologies used by directional detectors. In particular, we summarize the challenges, advantages and drawbacks of each approach, and discuss future prospects for these technologies.
△ Less
Submitted 6 October, 2016;
originally announced October 2016.
-
A performance study of an electron-tracking Compton camera with a compact system for environmental gamma-ray observation
Authors:
Tetsuya Mizumoto,
Dai Tomono,
Atsushi Takada,
Toru Tanimori,
Shotaro Komura,
Hidetoshi Kubo,
Yoshihiro Matsuoka,
Yoshitaka Mizumura,
Kiseki Nakamura,
Shogo Nakamura,
Makoto Oda,
Joseph D. Parker,
Tatsuya Sawano,
Naoto Bando,
Akira Nabetani
Abstract:
An electron-tracking Compton camera (ETCC) is a detector that can determine the arrival direction and energy of incident sub-MeV/MeV gamma-ray events on an event-by-event basis. It is a hybrid detector consisting of a gaseous time projection chamber (TPC), that is the Compton-scattering target and the tracker of recoil electrons, and a position-sensitive scintillation camera that absorbs of the sc…
▽ More
An electron-tracking Compton camera (ETCC) is a detector that can determine the arrival direction and energy of incident sub-MeV/MeV gamma-ray events on an event-by-event basis. It is a hybrid detector consisting of a gaseous time projection chamber (TPC), that is the Compton-scattering target and the tracker of recoil electrons, and a position-sensitive scintillation camera that absorbs of the scattered gamma rays, to measure gamma rays in the environment from contaminated soil. To measure of environmental gamma rays from soil contaminated with radioactive cesium (Cs), we developed a portable battery-powered ETCC system with a compact readout circuit and data-acquisition system for the SMILE-II experiment. We checked the gamma-ray imaging ability and ETCC performance in the laboratory by using several gamma-ray point sources. The performance test indicates that the field of view (FoV) of the detector is about 1$\;$sr and that the detection efficiency and angular resolution for 662$\;$keV gamma rays from the center of the FoV is $(9.31 \pm 0.95) \times 10^{^-5}$ and $5.9^{\circ} \pm 0.6^{\circ}$, respectively. Furthermore, the ETCC can detect 0.15$\;μ\rm{Sv/h}$ from a $^{137}$Cs gamma-ray source with a significance of 5$σ$ in 13 min in the laboratory. In this paper, we report the specifications of the ETCC and the results of the performance tests. Furthermore, we discuss its potential use for environmental gamma-ray measurements.
△ Less
Submitted 6 August, 2015;
originally announced August 2015.
-
Performance of a new electron-tracking Compton camera under intense radiations from a water target irradiated with a proton beam
Authors:
Yoshihiro Matsuoka,
T. Tanimori,
H. Kubo,
A. Takada,
J. D. Parker,
T. Mizumoto,
Y. Mizumura,
S. Iwaki,
T. Sawano,
S. Komura,
T. Kishimoto,
M. Oda,
T. Takemura,
S. Miyamoto,
S. Sonoda,
D. Tomono,
K. Miuchi,
S. Kabuki,
S. Kurosawa
Abstract:
We have developed an electron-tracking Compton camera (ETCC) for use in next-generation MeV gamma ray telescopes. An ETCC consists of a gaseous time projection chamber (TPC) and pixel scintillator arrays (PSAs). Since the TPC measures the three dimensional tracks of Compton-recoil electrons, the ETCC can completely reconstruct the incident gamma rays. Moreover, the ETCC demonstrates efficient back…
▽ More
We have developed an electron-tracking Compton camera (ETCC) for use in next-generation MeV gamma ray telescopes. An ETCC consists of a gaseous time projection chamber (TPC) and pixel scintillator arrays (PSAs). Since the TPC measures the three dimensional tracks of Compton-recoil electrons, the ETCC can completely reconstruct the incident gamma rays. Moreover, the ETCC demonstrates efficient background rejection power in Compton-kinematics tests, identifies particle from the energy deposit rate (dE/dX) registered in the TPC, and provides high quality imaging by completely reconstructing the Compton scattering process. We are planning the "Sub-MeV gamma ray Imaging Loaded-on-balloon Experiment" (SMILE) for our proposed all-sky survey satellite. Performance tests of a mid-sized 30 cm-cubic ETCC, constructed for observing the Crab nebula, are ongoing. However, observations at balloon altitudes or satellite orbits are obstructed by radiation background from the atmosphere and the detector itself. The background rejection power was checked using proton accelerator experiments conducted at the Research Center for Nuclear Physics, Osaka University. To create the intense radiation fields encountered in space, which comprise gamma rays, neutrons, protons, and other energetic entities, we irradiated a water target with a 140 MeV proton beam and placed a SMILE-II ETCC near the target. In this situation, the counting rate was five times than that expected at the balloon altitude. Nonetheless, the ETCC stably operated and identified particles sufficiently to obtain a clear gamma ray image of the checking source. Here, we report the performance of our detector and demonstrate its effective background rejection based in electron tracking experiments.
△ Less
Submitted 22 January, 2015; v1 submitted 12 December, 2014;
originally announced December 2014.
-
Development of a 30 cm-cube Electron-Tracking Compton Camera for the SMILE-II Experiment
Authors:
Y. Mizumura,
T. Tanimori,
H. Kubo,
A. Takada,
J. D. Parker,
T. Mizumoto,
S. Sonoda,
D. Tomono,
T. Sawano,
K. Nakamura,
Y. Matsuoka,
S. Komura,
S. Nakamura,
M. Oda,
K. Miuchi,
S. Kabuki,
Y. Kishimoto,
S. Kurosawa,
S. Iwaki
Abstract:
To explore the sub-MeV/MeV gamma-ray window for astronomy, we have developed the Electron-Tracking Compton Camera (ETCC), and carried out the first performance test at room condition using several gamma-ray sources in the sub-MeV energy band. Using a simple track analysis for a quick first test of the performance, the gamma-ray imaging capability was demonstrated by clear images and 5.3 degrees of…
▽ More
To explore the sub-MeV/MeV gamma-ray window for astronomy, we have developed the Electron-Tracking Compton Camera (ETCC), and carried out the first performance test at room condition using several gamma-ray sources in the sub-MeV energy band. Using a simple track analysis for a quick first test of the performance, the gamma-ray imaging capability was demonstrated by clear images and 5.3 degrees of angular resolution measure (ARM) measured at 662 keV. As the greatest impact of this work, a gamma-ray detection efficiency on the order of $10^{-4}$ was achieved at the sub-MeV gamma-ray band, which is one order of magnitude higher than our previous experiment. This angular resolution and detection efficiency enables us to detect the Crab Nebula at the 5 sigma level with several hours observation at balloon altitude in middle latitude. Furthermore, good consistency of efficiencies between this performance test and simulation including only physical processes has a large importance; it means we achieve nearly 100% detection of Compton recoil electrons. Thus, our estimation of enhancements by upgrades of the detector is more dependable. We are planning to confirm the imaging capability of the ETCC by observation of celestial objects in the SMILE-II (Sub-MeV gamma ray Imaging Loaded-on-balloon Experiment II). The SMILE-II and following SMILE-III project will be an important key of sub-MeV/MeV gamma-ray astronomy.
△ Less
Submitted 7 February, 2014; v1 submitted 2 December, 2013;
originally announced December 2013.
-
Development of a Time-resolved Neutron Imaging Detector Based on the μPIC Micro-Pixel Chamber
Authors:
Joseph D Parker,
Masahide Harada,
Kaori Hattori,
Satoru Iwaki,
Shigeto Kabuki,
Yuji Kishimoto,
Hidetoshi Kubo,
Shunsuke Kurosawa,
Yoshihiro Matsuoka,
Kentaro Miuchi,
Tetsuya Mizumoto,
Hironobu Nishimura,
Takayuki Oku,
Tatsuya Sawano,
Takenao Shinohara,
Jun-ichi Suzuki,
Atsushi Takada,
Toru Tanimori,
Kazuki Ueno,
Masahiro Ikeno,
Manobu Tanaka,
Tomohisa Uchida
Abstract:
We have developed a prototype time-resolved neutron imaging detector employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data acquisition system. Our detector system combines 100μm-level spatial and sub-μs time resolutions with a low gamma sensitivity of less than 10^-12 and high data rates, making it well suited for…
▽ More
We have developed a prototype time-resolved neutron imaging detector employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data acquisition system. Our detector system combines 100μm-level spatial and sub-μs time resolutions with a low gamma sensitivity of less than 10^-12 and high data rates, making it well suited for applications in neutron radiography at high-intensity, pulsed neutron sources. In the present paper, we introduce the detector system and present several test measurements performed at NOBORU (BL10), J-PARC to demonstrate the capabilities of our prototype. We also discuss future improvements to the spatial resolution and rate performance.
△ Less
Submitted 20 May, 2013;
originally announced May 2013.
-
Spatial resolution of a μPIC-based neutron imaging detector
Authors:
Joseph D. Parker,
Masahide Harada,
Kaori Hattori,
Satoru Iwaki,
Shigeto Kabuki,
Yuji Kishimoto,
Hidetoshi Kubo,
Shunsuke Kurosawa,
Yoshihiro Matsuoka,
Kentaro Miuchi,
Tetsuya Mizumoto,
Hironobu Nishimura,
Takayuki Oku,
Tatsuya Sawano,
Takenao Shinohara,
Jun-ichi Suzuki,
Atsushi Takada,
Toru Tanimori,
Kazuki Ueno
Abstract:
We present a detailed study of the spatial resolution of our time-resolved neutron imaging detector utilizing a new neutron position reconstruction method that improves both spatial resolution and event reconstruction efficiency. Our prototype detector system, employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data…
▽ More
We present a detailed study of the spatial resolution of our time-resolved neutron imaging detector utilizing a new neutron position reconstruction method that improves both spatial resolution and event reconstruction efficiency. Our prototype detector system, employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data acquisition system, combines 100μm-level spatial and sub-μs time resolutions with excellent gamma rejection and high data rates, making it well suited for applications in neutron radiography at high-intensity, pulsed neutron sources. From data taken at the Materials and Life Science Experimental Facility within the Japan Proton Accelerator Research Complex (J-PARC), the spatial resolution was found to be approximately Gaussian with a sigma of 103.48 +/- 0.77 μm (after correcting for beam divergence). This is a significant improvement over that achievable with our previous reconstruction method (334 +/- 13 μm), and compares well with conventional neutron imaging detectors and with other high-rate detectors currently under development. Further, a detector simulation indicates that a spatial resolution of less than 60 μm may be possible with optimization of the gas characteristics and μPIC structure. We also present an example of imaging combined with neutron resonance absorption spectroscopy.
△ Less
Submitted 16 May, 2013;
originally announced May 2013.
-
Neutron imaging detector based on the muPIC micro-pixel chamber
Authors:
J. D. Parker,
K. Hattori,
H. Fujioka,
M. Harada,
S. Iwaki,
S. Kabuki,
Y. Kishimoto,
H. Kubo,
S. Kurosawa,
K. Miuchi,
T. Nagae,
H. Nishimura,
T. Oku,
T. Sawano,
T. Shinohara,
J. Suzuki,
A. Takada,
T. Tanimori,
K. Ueno
Abstract:
We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in neutron radiography at high-intensity neutron sources. The prototype system, with an active area of 10cm x 10cm and operated at a gas pressure of 2 atm, measur…
▽ More
We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in neutron radiography at high-intensity neutron sources. The prototype system, with an active area of 10cm x 10cm and operated at a gas pressure of 2 atm, measures both the energy deposition (via time-over-threshold) and 3-dimensional track of each neutron-induced event, allowing the reconstruction of the neutron interaction point with improved accuracy. Using a simple position reconstruction algorithm, a spatial resolution of 349 +/- 36 microns was achieved, with further improvement expected. The detailed tracking allows strong rejection of background gamma-rays, resulting in an effective gamma sensitivity of 10^-12 or less, coupled with stable, robust neutron identification. The detector also features a time resolution of 0.6 microseconds.
△ Less
Submitted 26 September, 2012;
originally announced September 2012.
-
Detector performance of the NEWAGE experiment
Authors:
Kentaro Miuchi,
Kaori Hattori,
Shigeto Kabuki,
Hidetoshi Kubo,
Shunsuke Kurosawa,
Hironobu Nishimura,
Yoko Okada,
Atsushi Takada,
Toru Tanimori,
Ken'ichi Tsuchiya,
Kazuki Ueno,
Hiroyuki Sekiya,
Atsushi Takeda
Abstract:
NEWAGE(NEw generation WIMP search with an Advanced Gaseous tracking device Experiment) project is a direction-sensitive dark matter search experiment with a gaseous micro time-projection-chamber(micro-TPC). We report on the performance of the micro-TPC with a detection volume of 23x28x30 cm3 operated with a carbon-tetra uoride (CF4) of 0.2 bar.
NEWAGE(NEw generation WIMP search with an Advanced Gaseous tracking device Experiment) project is a direction-sensitive dark matter search experiment with a gaseous micro time-projection-chamber(micro-TPC). We report on the performance of the micro-TPC with a detection volume of 23x28x30 cm3 operated with a carbon-tetra uoride (CF4) of 0.2 bar.
△ Less
Submitted 10 January, 2007;
originally announced January 2007.
-
Performance of a Time-Projection-Chamber with a Large-Area Micro-Pixel-Chamber Readout
Authors:
Kentaro Miuchi,
Kaori Hattori,
Shigeto Kabuki,
Hidetoshi Kubo,
Shunsuke Kurosawa,
Hironobu Nishimura,
Atsushi Takada,
Ken'ichi Tsuchiya,
Yoko Okada,
Toru Tanimori,
Kazuki Ueno
Abstract:
A micro time-projection-chamber (micro-TPC) with a detection volume of 23*28*31 cm^3 was developed, and its fundamental performance was examined. The micro-TPC consists of a micro pixel chamber with a detection area of 31*31 cm^2 as a two-dimensional imaging device and a gas electron multiplier with an effective area of 23*28 cm^2 as a pre-gas-multiplier. The micro-TPC was operated at a gas gain…
▽ More
A micro time-projection-chamber (micro-TPC) with a detection volume of 23*28*31 cm^3 was developed, and its fundamental performance was examined. The micro-TPC consists of a micro pixel chamber with a detection area of 31*31 cm^2 as a two-dimensional imaging device and a gas electron multiplier with an effective area of 23*28 cm^2 as a pre-gas-multiplier. The micro-TPC was operated at a gas gain of 50,000, and energy resolutions and spatial resolutions were measured.
△ Less
Submitted 8 January, 2007;
originally announced January 2007.
-
Studies of the performance of different front-end systems for flat-panel multi-anode PMTs with CsI(Tl) scintillator arrays
Authors:
H. Sekiya,
K. Hattori,
H. Kubo,
K. Miuchi,
T. Nagayoshi,
H. Nishimura,
Y. Okada,
R. Orito,
A. Takada,
A. Takeda,
T. Tanimori,
K. Ueno
Abstract:
We have studied the performance of two different types of front-end systems for our gamma camera based on Hamamatsu H8500 (flat-panel 64 channels multi-anode PSPMT) with a CsI(Tl) scintillator array. The array consists of 64 pixels of $6\times6\times20{\rm mm}^3$ which corresponds to the anode pixels of H8500. One of the system is based on commercial ASIC chips in order to readout every anode. T…
▽ More
We have studied the performance of two different types of front-end systems for our gamma camera based on Hamamatsu H8500 (flat-panel 64 channels multi-anode PSPMT) with a CsI(Tl) scintillator array. The array consists of 64 pixels of $6\times6\times20{\rm mm}^3$ which corresponds to the anode pixels of H8500. One of the system is based on commercial ASIC chips in order to readout every anode. The others are based on resistive charge divider network between anodes to reduce readout channels. In both systems, each pixel (6mm) was clearly resolved by flood field irradiation of $^{137}$Cs. We also investigated the energy resolution of these systems and showed the performance of the cascade connection of resistive network between some PMTs for large area detectors.
△ Less
Submitted 25 October, 2005;
originally announced October 2005.
-
Simulation study of electron drift and gas multiplication in Micro Pixel Chamber
Authors:
Tsutomu Nagayoshi,
Atsushi Takada,
Hidetoshi Kubo,
Kentaro Miuchi,
Reiko Orito,
Yoko Okada,
Atsushi Takeda,
Toru Tanimori,
Masaru Ueno,
Oleg Bouianov,
Marina Bouianov
Abstract:
The physical processes of charge collection and gas multiplication of a Micro Pixel Chamber (mu-PIC) were studied in detail using a three-dimensional simulation. The collection efficiencies of primary electrons and gas multiplication factors were calculated for several electrode structures. Based on those studies, we analyzed the optimization of the electrode structure of the mu-PIC, in order to…
▽ More
The physical processes of charge collection and gas multiplication of a Micro Pixel Chamber (mu-PIC) were studied in detail using a three-dimensional simulation. The collection efficiencies of primary electrons and gas multiplication factors were calculated for several electrode structures. Based on those studies, we analyzed the optimization of the electrode structure of the mu-PIC, in order to obtain a high gas gain of more than 10^4 and a simultaneous suppression of discharges. Consequently, we found that these characteristics strongly depend on the substrate thickness and the anode diameter of the mu-PIC. In addition, a gas gain of 10^5 would be expected for a mu-PIC having a thick substrate of > 150um.
△ Less
Submitted 29 March, 2005;
originally announced March 2005.
-
Development of an ASD IC for the Micro Pixel Chamber
Authors:
R. Orito,
O. Sasaki,
H. Kubo,
K. Miuchi,
T. Nagayoshi,
Y. Okada,
A. Takada,
A. Takeda,
T. Tanimori,
M. Ueno
Abstract:
A new amplifier-shaper-discriminator (ASD) chip was designed and manufactured for the Micro Pixel Chamber ($μ$-PIC). The design of this ASD IC is based on the ASD IC (TGC-ASD) for the Thin Gap Chamber in the LHC Atlas Experiment. The decay time constant of the preamplifier is 5-times longer than that of the TGC-ASD, and some other modifications have been made in order to improve the signal-to-no…
▽ More
A new amplifier-shaper-discriminator (ASD) chip was designed and manufactured for the Micro Pixel Chamber ($μ$-PIC). The design of this ASD IC is based on the ASD IC (TGC-ASD) for the Thin Gap Chamber in the LHC Atlas Experiment. The decay time constant of the preamplifier is 5-times longer than that of the TGC-ASD, and some other modifications have been made in order to improve the signal-to-noise ratio of the $μ$-PIC. The ASD IC uses SONY Analog Master Slice bipolar technology. The IC contains 4 channels in a QFP48 package. The decay time constant of the preamplifier is 80 ns and its gain is approximately 0.8 V/pC. The output from the preamplifier is received by a shaper (main-amplifier) with a gain of 7. A baseline restoration circuit is incorporated in the main-amplifier, and the current used for the baseline restoration is 5-times smaller than that of the TGC-ASD. The threshold voltage for the discriminator section is common to the 4 channels and their digital output level is LVDS-compatible. The ASD IC also has an analog output of the preamplifier. The equivalent noise charge at the input capacitance of 50 pF is around 2000 electrons. The power dissipation with LVDS outputs (100 $Ω$ load) is 57 mW/ch. Using this ASD, the analog output voltage from the signal of the $μ$-PIC is about 2-times higher than the case of using the TGC-ASD.As a consequence, the MIPs tracking performance of the Time Projection Chamber (TPC) with the $μ$-PIC was improved.The performance of the ASD IC and an improved tracking performance of the TPC are reported.
△ Less
Submitted 10 March, 2004;
originally announced March 2004.
-
Performance of a micro-TPC for a time-resolved neutron PSD
Authors:
Kentaro Miuchi,
Hidetoshi Kubo,
Tsutomu Nagayoshi,
Reiko Orito,
Atsushi Takada,
Atsushi Takeda,
Toru Tanimori,
Masaru Ueno
Abstract:
We report on the performance of a micro-TPC with a micro pixel chamber($μ$-PIC) readout for a time-resolved neutron position-sensitive detector(PSD). Three-dimensional tracks and the Bragg curves of protons with energies of around 1 MeV were clearly detected by the micro-TPC. More than 95% of gamma-rays of 511 keV were found to be discriminated by simple analysis. Simulation studies showed that…
▽ More
We report on the performance of a micro-TPC with a micro pixel chamber($μ$-PIC) readout for a time-resolved neutron position-sensitive detector(PSD). Three-dimensional tracks and the Bragg curves of protons with energies of around 1 MeV were clearly detected by the micro-TPC. More than 95% of gamma-rays of 511 keV were found to be discriminated by simple analysis. Simulation studies showed that the total track length of proton and triton emitted from the $\rm {}^{3}He$(n,p(573 keV))$\rm {}^{3}H(191 keV)$ reaction is about 1.2 cm, and that both particles have large energy losses ($\rm > 200 keV/cm$) in 1 atm Ar+$\rm C_{2}H_{6}(10%)$+${}^{3}$He($< 1%$). These values suit the current performance of the micro-TPC, and we conclude that a time-resolved neutron PSD with spatial resolution of sub-millimeters shall be developed as an application of the micro-TPC.
△ Less
Submitted 27 August, 2003;
originally announced August 2003.