-
The Front-End electronics for the liquid Argon instrumentation of the LEGEND-200 experiment
Authors:
I. Abritta Costa,
A. Budano,
N. Burlac,
F. Paissan,
G. Salamanna,
D. Tagnani
Abstract:
In this paper we provide a detailed technical description of the Front-End (FE) electronics for the liquid Argon instrumentation of the LEGEND-200 experiment, searching for the very rare, hypothetical neutrinoless double $β$ decay process at the Italian Laboratori Nazionali del Gran Sasso. The design stems from the need to read out the silicon photo-multiplier response to the scintillation light i…
▽ More
In this paper we provide a detailed technical description of the Front-End (FE) electronics for the liquid Argon instrumentation of the LEGEND-200 experiment, searching for the very rare, hypothetical neutrinoless double $β$ decay process at the Italian Laboratori Nazionali del Gran Sasso. The design stems from the need to read out the silicon photo-multiplier response to the scintillation light in the liquid Argon with excellent single-photon resolution. The FE electronics is required to be placed far from the detectors to meet the experiment's radio-purity constraints. This constraint represents a challenge for a high signal-to-noise ratio. We address how this could be achieved in a stable way. The system was installed in July 2021 and has been commissioned with the rest of LEGEND-200, proving we could attain a very low overall level of electrical noise of 250 $μ$V peak-to-peak.
△ Less
Submitted 22 June, 2023; v1 submitted 6 November, 2022;
originally announced November 2022.
-
Cross-section measurement of two-photon annihilation in-flight of positrons at $\sqrt{s}=20$ MeV with the PADME detector
Authors:
F. Bossi,
P. Branchini,
B. Buonomo,
V. Capirossi,
A. P. Caricato,
G. Chiodini,
R. De Sangro,
C. Di Giulio,
D. Domenici,
F. Ferrarotto,
G. Finocchiaro,
L. G Foggetta,
A. Frankenthal,
M. Garattini,
G. Georgiev,
F. Giacchino,
P. Gianotti,
S. Ivanov,
Sv. Ivanov,
V. Kozhuharov,
E. Leonardi,
E. Long,
M. Martino,
I. Oceano,
F. Oliva
, et al. (13 additional authors not shown)
Abstract:
The inclusive cross-section of annihilation in flight $e^+e^-\rightarrowγγ$ of 430 MeV positrons with atomic electrons of a thin diamond target has been measured with the PADME detector at the Laboratori Nazionali di Frascati. The two photons produced in the process were detected by an electromagnetic calorimeter made of BGO crystals. This measurement is the first one based on the direct detection…
▽ More
The inclusive cross-section of annihilation in flight $e^+e^-\rightarrowγγ$ of 430 MeV positrons with atomic electrons of a thin diamond target has been measured with the PADME detector at the Laboratori Nazionali di Frascati. The two photons produced in the process were detected by an electromagnetic calorimeter made of BGO crystals. This measurement is the first one based on the direct detection of the photon pair and one of the most precise for positron energies below 1 GeV. This measurement represents a necessary step to search for dark sector particles and mediators weakly coupled to photons and/or electrons with masses ranging from 1 MeV to 20 MeV with PADME. The measurement agrees with the Next to Leading Order QED prediction within the overall 6% uncertainty.
△ Less
Submitted 7 November, 2022; v1 submitted 26 October, 2022;
originally announced October 2022.
-
Dark sector studies with the PADME experiment
Authors:
Anna Paola Caricato,
Maurizio Martino,
Isabella Oceano,
Federica Oliva,
Stefania Spagnolo,
Gabriele Chiodini,
Fabio Bossi,
Riccardo De Sangro,
Claudio Di Giulio,
Danilo Domenici,
Giuseppe Finocchiaro,
Luca Gennaro Foggetta,
Marco Garattini,
Andrea Ghigo,
Federica Giacchino,
Paola Gianotti,
Tommaso Spadaro,
Eletuerio Spiriti,
Clara Taruggi,
Elisabetta Vilucchi,
Venelin Kozhuharov,
Simeon Ivanov,
Svetoslav Ivanov,
Radoslav Simeonov,
Georgi Georgiev
, et al. (13 additional authors not shown)
Abstract:
The Positron Annihilation to Dark Matter Experiment (PADME) uses the positron beam of the DA$Φ$NE Beam-Test Facility, at the Laboratori Nazionali di Frascati (LNF) to search for a Dark Photon $A'$. The search technique studies the missing mass spectrum of single-photon final states in $e^+e^-\rightarrow A'γ$ annihilation in a positron-on-thin-target experiment. This approach facilitates searches f…
▽ More
The Positron Annihilation to Dark Matter Experiment (PADME) uses the positron beam of the DA$Φ$NE Beam-Test Facility, at the Laboratori Nazionali di Frascati (LNF) to search for a Dark Photon $A'$. The search technique studies the missing mass spectrum of single-photon final states in $e^+e^-\rightarrow A'γ$ annihilation in a positron-on-thin-target experiment. This approach facilitates searches for new particles such as long lived Axion-Like-Particles, protophobic X bosons and Dark Higgs. This talk illustrated the scientific program of the experiment and its first physics results. In particular, the measurement of the cross-section of the SM process $e^+e^-\rightarrow γγ$ at $\sqrt{s}$=21 MeV was shown.
△ Less
Submitted 1 May, 2023; v1 submitted 29 September, 2022;
originally announced September 2022.
-
Crilin: A CRystal calorImeter with Longitudinal InformatioN for a future Muon Collider
Authors:
S. Ceravolo,
F. Colao,
C. Curatolo,
E. Di Meco,
E. Diociaiuti,
D. Lucchesi,
D. Paesani,
N. Pastrone,
A. Saputi,
I. Sarra,
L. Sestini,
D. Tagnani
Abstract:
The measurement of physics processes at new energy frontier experiments requires excellent spatial, time, and energy resolutions to resolve the structure of collimated high-energy jets. In a future Muon Collider, the beam-induced backgrounds (BIB) represent the main challenge in the design of the detectors and of the event reconstruction algorithms. The technology and the design of the calorimeter…
▽ More
The measurement of physics processes at new energy frontier experiments requires excellent spatial, time, and energy resolutions to resolve the structure of collimated high-energy jets. In a future Muon Collider, the beam-induced backgrounds (BIB) represent the main challenge in the design of the detectors and of the event reconstruction algorithms. The technology and the design of the calorimeters should be chosen to reduce the effect of the BIB, while kee** good physics performance. Several requirements can be inferred: i) high granularity to reduce the overlap of BIB particles in the same calorimeter cell; ii) excellent timing (of the order of 100 ps) to reduce the out-of-time component of the BIB; iii) longitudinal segmentation to distinguish the signal showers from the fake showers produced by the BIB; iv) good energy resolution (less than 10%/sqrt(E)) to obtain good physics performance, as has been already demonstrated for conceptual particle flow calorimeters. Our proposal consists of a semi-homogeneous electromagnetic calorimeter based on Lead Fluoride Crystals (PbF2) readout by surface-mount UV-extended Silicon Photomultipliers (SiPMs): the Crilin calorimeter. In this paper, the performances of the Crilin calorimeter in the Muon Collider framework for hadron jets reconstruction have been analyzed. We report the single components characterizations together with the development of a small-scale prototype, consisting of 2 layers of 3x3 crystals each.
△ Less
Submitted 7 September, 2022; v1 submitted 12 June, 2022;
originally announced June 2022.
-
Commissioning of the PADME experiment with a positron beam
Authors:
P. Albicocco,
R. Assiro,
F. Bossi,
P. Branchini,
B. Buonomo,
V. Capirossi,
E. Capitolo,
C. Capoccia,
A. P. Caricato,
S. Ceravolo,
G. Chiodini,
G. Corradi,
R. De Sangro,
C. Di Giulio,
D. Domenici,
F. Ferrarotto,
S. Fiore,
G. Finocchiaro,
L. G Foggetta,
A. Frankenthal,
M. Garattini,
G. Georgiev,
F. Giacchino,
A. Ghigo,
P. Gianotti
, et al. (31 additional authors not shown)
Abstract:
The PADME experiment is designed to search for a hypothetical dark photon $A^{\prime}$ produced in positron-electron annihilation using a bunched positron beam at the Beam Test Facility of the INFN Laboratori Nazionali di Frascati. The expected sensitivity to the $A^{\prime}$-photon mixing parameter $ε$ is 10$^{-3}$, for $A^{\prime}$ mass $\le$ 23.5 MeV/$c^{2}$ after collecting $\sim 10^{13}$ posi…
▽ More
The PADME experiment is designed to search for a hypothetical dark photon $A^{\prime}$ produced in positron-electron annihilation using a bunched positron beam at the Beam Test Facility of the INFN Laboratori Nazionali di Frascati. The expected sensitivity to the $A^{\prime}$-photon mixing parameter $ε$ is 10$^{-3}$, for $A^{\prime}$ mass $\le$ 23.5 MeV/$c^{2}$ after collecting $\sim 10^{13}$ positrons-on-target.
This paper presents the PADME detector status after commissioning in July 2019. In addition, the software algorithms employed to reconstruct physics objects, such as photons and charged particles, and the calibration procedures adopted are illustrated in detail. The results show that the experimental apparatus reaches the design performance, and is able to identify and measure standard electromagnetic processes, such as positron Bremsstrahlung, electron-positron annihilation into two photons.
△ Less
Submitted 20 July, 2022; v1 submitted 6 May, 2022;
originally announced May 2022.
-
Radiation study of Lead Fluoride crystals
Authors:
A. Cemmi,
A. Colangeli,
B. D'orsi,
I. Di Sarcina,
E. Diociaiuti,
S. Fiore,
D. Paesani,
M. Pillon,
A. Saputi,
I. Sarra,
D. Tagnani
Abstract:
Lead fluoride (PbF$_2$) crystals represent an excellent and relatively innovative choice for high resolution electromagnetic calorimeters with high granularity and fast timing for high intensity environments. For this reason two PbF$_2$ crystals, sized $5\times 5 \times 40 $ mm$^3$, were irradiated with $^{60}$Co photons up to $\sim 4$ Mrad and with 14 MeV neutrons up to a $10^{13}$ n/cm$^2$ total…
▽ More
Lead fluoride (PbF$_2$) crystals represent an excellent and relatively innovative choice for high resolution electromagnetic calorimeters with high granularity and fast timing for high intensity environments. For this reason two PbF$_2$ crystals, sized $5\times 5 \times 40 $ mm$^3$, were irradiated with $^{60}$Co photons up to $\sim 4$ Mrad and with 14 MeV neutrons up to a $10^{13}$ n/cm$^2$ total fluence. Their loss in transmittance was evaluated at different steps of the photon and neutron irradiation campaign, resulting in a total of 30% loss above 350 nm. With crystals always kept in dark conditions, natural and thermal annealing, as well as optical bleaching with 400 nm light, were performed on the irradiated specimens, resulting in a partial recovery of their original optical characteristics.
△ Less
Submitted 14 April, 2022; v1 submitted 26 July, 2021;
originally announced July 2021.
-
LEGEND-1000 Preconceptual Design Report
Authors:
LEGEND Collaboration,
N. Abgrall,
I. Abt,
M. Agostini,
A. Alexander,
C. Andreoiu,
G. R. Araujo,
F. T. Avignone III,
W. Bae,
A. Bakalyarov,
M. Balata,
M. Bantel,
I. Barabanov,
A. S. Barabash,
P. S. Barbeau,
C. J. Barton,
P. J. Barton,
L. Baudis,
C. Bauer,
E. Bernieri,
L. Bezrukov,
K. H. Bhimani,
V. Biancacci,
E. Blalock,
A. Bolozdynya
, et al. (239 additional authors not shown)
Abstract:
We propose the construction of LEGEND-1000, the ton-scale Large Enriched Germanium Experiment for Neutrinoless $ββ$ Decay. This international experiment is designed to answer one of the highest priority questions in fundamental physics. It consists of 1000 kg of Ge detectors enriched to more than 90% in the $^{76}$Ge isotope operated in a liquid argon active shield at a deep underground laboratory…
▽ More
We propose the construction of LEGEND-1000, the ton-scale Large Enriched Germanium Experiment for Neutrinoless $ββ$ Decay. This international experiment is designed to answer one of the highest priority questions in fundamental physics. It consists of 1000 kg of Ge detectors enriched to more than 90% in the $^{76}$Ge isotope operated in a liquid argon active shield at a deep underground laboratory. By combining the lowest background levels with the best energy resolution in the field, LEGEND-1000 will perform a quasi-background-free search and can make an unambiguous discovery of neutrinoless double-beta decay with just a handful of counts at the decay $Q$ value. The experiment is designed to probe this decay with a 99.7%-CL discovery sensitivity in the $^{76}$Ge half-life of $1.3\times10^{28}$ years, corresponding to an effective Majorana mass upper limit in the range of 9-21 meV, to cover the inverted-ordering neutrino mass scale with 10 yr of live time.
△ Less
Submitted 23 July, 2021;
originally announced July 2021.
-
Characterisation and performance of the PADME electromagnetic calorimeter
Authors:
P. Albicocco,
J. Alexander,
F. Bossi,
P. Branchini,
B. Buonomo,
C. Capoccia,
E. Capitolo,
G. Chiodini,
A. P. Caricato,
R. de Sangro,
C. Di Giulio,
D. Domenici,
F. Ferrarotto,
G. Finocchiaro,
S. Fiore,
L. G. Foggetta,
A. Frankenthal,
G. Georgiev,
A. Ghigo,
F. Giacchino,
P. Gianotti,
S. Ivanov,
V. Kozhuharov,
E. Leonardi,
B. Liberti
, et al. (20 additional authors not shown)
Abstract:
The PADME experiment at the LNF Beam Test Facility searches for dark photons produced in the annihilation of positrons with the electrons of a fix target. The strategy is to look for the reaction $e^{+}+e^{-}\rightarrow γ+A'$, where $A'$ is the dark photon, which cannot be observed directly or via its decay products. The electromagnetic calorimeter plays a key role in the experiment by measuring t…
▽ More
The PADME experiment at the LNF Beam Test Facility searches for dark photons produced in the annihilation of positrons with the electrons of a fix target. The strategy is to look for the reaction $e^{+}+e^{-}\rightarrow γ+A'$, where $A'$ is the dark photon, which cannot be observed directly or via its decay products. The electromagnetic calorimeter plays a key role in the experiment by measuring the energy and position of the final-state $γ$. The missing four-momentum carried away by the $A'$ can be evaluated from this information and the particle mass inferred. This paper presents the design, construction, and calibration of the PADME's electromagnetic calorimeter. The results achieved in terms of equalisation, detection efficiency and energy resolution during the first phase of the experiment demonstrate the effectiveness of the various tools used to improve the calorimeter performance with respect to earlier prototypes.
△ Less
Submitted 21 October, 2020; v1 submitted 28 July, 2020;
originally announced July 2020.
-
Search for $K^{+}\rightarrowπ^{+}ν\overlineν$ at NA62
Authors:
NA62 Collaboration,
G. Aglieri Rinella,
R. Aliberti,
F. Ambrosino,
R. Ammendola,
B. Angelucci,
A. Antonelli,
G. Anzivino,
R. Arcidiacono,
I. Azhinenko,
S. Balev,
M. Barbanera,
J. Bendotti,
A. Biagioni,
L. Bician,
C. Biino,
A. Bizzeti,
T. Blazek,
A. Blik,
B. Bloch-Devaux,
V. Bolotov,
V. Bonaiuto,
M. Boretto,
M. Bragadireanu,
D. Britton
, et al. (227 additional authors not shown)
Abstract:
$K^{+}\rightarrowπ^{+}ν\overlineν$ is one of the theoretically cleanest meson decay where to look for indirect effects of new physics complementary to LHC searches. The NA62 experiment at CERN SPS is designed to measure the branching ratio of this decay with 10\% precision. NA62 took data in pilot runs in 2014 and 2015 reaching the final designed beam intensity. The quality of 2015 data acquired,…
▽ More
$K^{+}\rightarrowπ^{+}ν\overlineν$ is one of the theoretically cleanest meson decay where to look for indirect effects of new physics complementary to LHC searches. The NA62 experiment at CERN SPS is designed to measure the branching ratio of this decay with 10\% precision. NA62 took data in pilot runs in 2014 and 2015 reaching the final designed beam intensity. The quality of 2015 data acquired, in view of the final measurement, will be presented.
△ Less
Submitted 24 July, 2018;
originally announced July 2018.
-
The Mu2e Calorimeter Final Technical Design Report
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
S. Ceravolo,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
E. Dane,
Y. Davydov,
S. Di Falco,
S. Donati,
E. Diociaiuti,
R. Donghia,
B. Echenard,
K. Flood,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi
, et al. (15 additional authors not shown)
Abstract:
Since the first version of the Mu2e TDR released at the beginning of 2015, the Mu2e Calorimeter system has undergone a long list of changes to arrive to its final design. These changes were primarily caused by two reasons: (i) the technology choice between the TDR proposed solution of BaF2 crystals readout with solar blind Avalanche Photodiodes (APDs) and the backup option of CsI crystals readout…
▽ More
Since the first version of the Mu2e TDR released at the beginning of 2015, the Mu2e Calorimeter system has undergone a long list of changes to arrive to its final design. These changes were primarily caused by two reasons: (i) the technology choice between the TDR proposed solution of BaF2 crystals readout with solar blind Avalanche Photodiodes (APDs) and the backup option of CsI crystals readout with Silicon Photomultipliers (SiPM) has been completed and (ii) the channels numbering, the mechanical system and the readout electronics were substantially modified while proceeding with engineering towards the final project. This document updates the description of the calorimeter system adding the most recent engineering drawings and tecnical progresses.
△ Less
Submitted 18 February, 2018;
originally announced February 2018.
-
Measurement of the energy and time resolution of a undoped CsI + MPPC array for the Mu2e experiment
Authors:
O. Atanova,
M. Cordelli,
G. Corradi,
F. Colao,
Yu. I. Davydov,
R. Donghia,
S. Di Falco,
S. Giovannella,
F. Happacher,
M. Martini,
S. Miscetti,
L. Morescalchi,
P. Murat,
G. Pezzullo,
A. Saputi,
I. Sarra,
S. R. Soleti,
D. Tagnani,
V. Tereshchenko,
Z. Usubov
Abstract:
This paper describes the measurements of energy and time response and resolution of a 3 x 3 array made of undoped CsI crystals coupled to large area Hamamatsu Multi Pixel Photon Counters. The measurements have been performed using the electron beam of the Beam Test Facility in Frascati (Rome, Italy) in the energy range 80-120 MeV. The measured energy resolution, estimated with the FWHM, at 100 MeV…
▽ More
This paper describes the measurements of energy and time response and resolution of a 3 x 3 array made of undoped CsI crystals coupled to large area Hamamatsu Multi Pixel Photon Counters. The measurements have been performed using the electron beam of the Beam Test Facility in Frascati (Rome, Italy) in the energy range 80-120 MeV. The measured energy resolution, estimated with the FWHM, at 100 MeV is 16.4%. This resolution is dominated by the energy leakage due to the small dimensions of the prototype. The time is reconstructed by fitting the leading edge of the digitized signals and applying a digital constant fraction discrimination technique. A time resolution of about 110 ps at 100 MeV is achieved.
△ Less
Submitted 13 February, 2017;
originally announced February 2017.
-
CHANTI: a Fast and Efficient Charged Particle Veto Detector for the NA62 Experiment at CERN
Authors:
F. Ambrosino,
T. Capussela,
D. Di Filippo,
P. Massarotti,
M. Mirra,
M. Napolitano,
V. Palladino,
G. Saracino,
L. Roscilli,
A. Vanzanella,
G. Corradi,
D. Tagnani,
U. Paglia
Abstract:
The design, construction and test of a charged particle detector made of scintillation counters read by Silicon Photomultipliers (SiPM) is described. The detector, which operates in vacuum and is used as a veto counter in the NA62 experiment at CERN, has a single channel time resolution of 1.14 ns, a spatial resolution of ~2.5 mm and an efficiency very close to 1 for penetrating charged particles.
The design, construction and test of a charged particle detector made of scintillation counters read by Silicon Photomultipliers (SiPM) is described. The detector, which operates in vacuum and is used as a veto counter in the NA62 experiment at CERN, has a single channel time resolution of 1.14 ns, a spatial resolution of ~2.5 mm and an efficiency very close to 1 for penetrating charged particles.
△ Less
Submitted 3 January, 2017; v1 submitted 1 December, 2015;
originally announced December 2015.
-
A GEM-based Time Projection Chamber for the AMADEUS experiment
Authors:
M. Poli Lener,
M. Bazzi,
G. Corradi,
C. Curceanu,
A. D'Uffizi,
C. Paglia,
E. Sbardella,
A. Scordo,
D. Tagnani,
A. Romero Vidal,
J. Zmeskal
Abstract:
In this paper we present the R&D activity on a new GEM-based TPC prototype for AMADEUS, a new experimental proposal at the DAΦNE Φ-factory at the Laboratori Nazionali di Frascati (INFN), aiming to perform measurements of the low-energy negative kaons interactions in nuclei. Such innovative detector will equip the inner part of the experiment in order to perfom a better reconstruction of the primar…
▽ More
In this paper we present the R&D activity on a new GEM-based TPC prototype for AMADEUS, a new experimental proposal at the DAΦNE Φ-factory at the Laboratori Nazionali di Frascati (INFN), aiming to perform measurements of the low-energy negative kaons interactions in nuclei. Such innovative detector will equip the inner part of the experiment in order to perfom a better reconstruction of the primary vertex and the secondary particles tracking. A 10x10 cm2 prototype with a drift gap up to 15 cm was realized and succesfully tested at the π M1 beam facility of the Paul Scherrer Institut (PSI) with low momentum hadrons. The measurements of the detector efficiency and spatial resolution have been performed. The results as a function of the gas gain, drift field, front-end electronic threshold and particle momentum are reported and discussed.
△ Less
Submitted 23 April, 2013;
originally announced April 2013.
-
Performances of a GEM-based Time Projection Chamber prototype for the AMADEUS experiment
Authors:
M. Poli Lener,
M. Bazzi,
G. Corradi,
C. Curceanu,
A. D'Uffizi,
C. Paglia,
A. Romero Vidal,
E. Sbardella,
A. Scordo,
D. Tagnani,
J. Zmeskal
Abstract:
A large number of high-energy and heavy-ion experiments successfully used Time Projection Chamber (TPC) as central tracker and particle identification detector. However, the performance requirements on TPC for new high-rate particle experiments greatly exceed the abilities of traditional TPC read out by multi-wire proportional chamber (MWPC). Gas Electron Multiplier (GEM) detector has great potent…
▽ More
A large number of high-energy and heavy-ion experiments successfully used Time Projection Chamber (TPC) as central tracker and particle identification detector. However, the performance requirements on TPC for new high-rate particle experiments greatly exceed the abilities of traditional TPC read out by multi-wire proportional chamber (MWPC). Gas Electron Multiplier (GEM) detector has great potential to improve TPC performances when used as amplification device. In this paper we present the R&D activity on a new GEM-based TPC detector built as a prototype for the inner part for AMADEUS, a new experimental proposal at the DAFNE collider at Laboratori Nazionali di Frascati (INFN), aiming to perform measurements of the low-energy negative kaons interactions in nuclei. In order to evaluate the GEM-TPC performances, a 10x10 cm2 prototype with a drift gap up to 15 cm has been realized. The detector was tested at the pM1 beam facility of the Paul Scherrer Institut (PSI) with low momentum pions and protons, without magnetic field. Drift properties of argonisobutane gas mixtures are measured and compared withMagboltz prediction. Detection efficiency and spatial resolution as a function of a large number of parameters, such as the gas gain, the drift field, the front-end electronic threshold and particle momentum, are illustrated and discussed. Particle identification capability and the measurement of the energy resolution in isobutane-based gas mixture are also reported.
△ Less
Submitted 13 February, 2013;
originally announced February 2013.
-
The NA62 LAV front-end electronics
Authors:
A. Antonelli,
G. Corradi,
M. Moulson,
C. Paglia,
M. Raggi,
T. Spadaro,
D. Tagnani,
F. Ambrosino,
D. Di Filippo,
P. Massarotti,
M. Napolitano,
G. Saracino,
B. Angelucci,
F. Costantini,
R. Fantechi,
S. Gallorini,
S. Giudici,
I. Mannelli,
F. Raffaelli,
S. Venditti,
G. D'Agostini,
E. Leonardi,
V. Palladino,
M. Serra,
P. Valente
Abstract:
The branching ratio for the decay $K^+ \to π^+ν\barν$ is sensitive to new physics; the NA62 experiment will measure it to within about 10%. To reject the dominant background from channels with final state photons, the large-angle vetoes (LAVs) must detect particles with better than 1 ns time resolution and 10% energy resolution over a very large energy range. Our custom readout board uses a time-o…
▽ More
The branching ratio for the decay $K^+ \to π^+ν\barν$ is sensitive to new physics; the NA62 experiment will measure it to within about 10%. To reject the dominant background from channels with final state photons, the large-angle vetoes (LAVs) must detect particles with better than 1 ns time resolution and 10% energy resolution over a very large energy range. Our custom readout board uses a time-over-threshold discriminator coupled to a TDC as a straightforward solution to satisfy these requirements. A prototype of the readout system was extensively tested together with the ANTI-A2 large angle veto module at CERN in summer 2010.
△ Less
Submitted 24 November, 2011;
originally announced November 2011.
-
Measurement of the neutron detection efficiency of a 80% absorber - 20% scintillating fibers calorimeter
Authors:
M. Anelli,
S. Bertolucci,
C. Bini,
P. Branchini,
G. Corradi,
C. Curceanu,
G. De Zorzi,
A. Di Domenico,
B. Di Micco,
A. Ferrari,
S. Fiore,
P. Gauzzi,
S. Giovannella,
F. Happacher,
M. Iliescu,
A. Luca',
M. Martini,
S. Miscetti,
F. Nguyen,
A. Passeri,
A. Prokofiev,
I. Sarra,
B. Sciascia,
F. Sirghi,
D. Tagnani
Abstract:
The neutron detection efficiency of a sampling calorimeter made of 1 mm diameter scintillating fibers embedded in a lead/bismuth structure has been measured at the neutron beam of the The Svedberg Laboratory at Uppsala. A significant enhancement of the detection efficiency with respect to a bulk organic scintillator detector with the same thickness is observed.
The neutron detection efficiency of a sampling calorimeter made of 1 mm diameter scintillating fibers embedded in a lead/bismuth structure has been measured at the neutron beam of the The Svedberg Laboratory at Uppsala. A significant enhancement of the detection efficiency with respect to a bulk organic scintillator detector with the same thickness is observed.
△ Less
Submitted 21 September, 2010; v1 submitted 13 April, 2010;
originally announced April 2010.
-
Measurement of neutron detection efficiency between 22 and 174 MeV using two different kinds of Pb-scintillating fiber sampling calorimeters
Authors:
M. Anelli,
S. Bertolucci,
C. Bini,
P. Branchini,
G. Corradi,
C. Curceanu,
G. De Zorzi,
A. Di Domenico,
B. Di Micco,
A. Ferrari,
S. Fiore,
P. Gauzzi,
S. Giovannella,
F. Happacher,
M. Ilieascu,
A. Luca',
M. Martini,
S. Miscetti,
F. Nguyen,
A. Passeri,
A. Prokofiev,
I. Sarra,
B. Sciascia,
F. Sirghi,
D. Tagnani
Abstract:
We exposed a prototype of the lead-scintillating fiber KLOE calorimeter to neutron beam of 21, 46 and 174 MeV at The Svedberg Laboratory, Uppsala, to study its neutron detection efficiency. This has been found larger than what expected considering the scintillator thickness of the prototype. %To check our method, we measured also the neutron %detection efficiency of a 5 cm thick NE110 scintillat…
▽ More
We exposed a prototype of the lead-scintillating fiber KLOE calorimeter to neutron beam of 21, 46 and 174 MeV at The Svedberg Laboratory, Uppsala, to study its neutron detection efficiency. This has been found larger than what expected considering the scintillator thickness of the prototype. %To check our method, we measured also the neutron %detection efficiency of a 5 cm thick NE110 scintillator. We show preliminary measurement carried out with a different prototype with a larger lead/fiber ratio, which proves the relevance of passive material to neutron detection efficiency in this kind of calorimeters.
△ Less
Submitted 5 June, 2009;
originally announced June 2009.
-
QCALT: a tile calorimeter for KLOE-2 upgrade
Authors:
M. Cordelli,
G. Corradi,
F. Happacher,
M. Martini,
S. Miscetti,
C. Paglia,
A. Saputi,
I. Sarra,
D. Tagnani
Abstract:
The upgrade of the DA$Φ$NE machine layout requires a modification of the size and position of the inner focusing quadrupoles of KLOE-2 thus asking for the realization of two new calorimeters covering the quadrupoles area. To improve the reconstruction of $K_L\to 2π^0$ events with photons hitting the quadrupoles a calorimeter with high efficiency to low energy photons (20-300 MeV), time resolutio…
▽ More
The upgrade of the DA$Φ$NE machine layout requires a modification of the size and position of the inner focusing quadrupoles of KLOE-2 thus asking for the realization of two new calorimeters covering the quadrupoles area. To improve the reconstruction of $K_L\to 2π^0$ events with photons hitting the quadrupoles a calorimeter with high efficiency to low energy photons (20-300 MeV), time resolution of less than 1 ns and space resolution of few cm, is needed. To match these requirements, we are designing a tile calorimeter, QCALT, where each single tile is readout by mean of SiPM for a total granularity of 2400 channels. We show first tests of the different calorimeter components.
△ Less
Submitted 5 June, 2009;
originally announced June 2009.
-
The Low Energy Tagger for the KLOE-2 experiment
Authors:
D. Babusci,
C. Bini,
P. Ciambrone,
G. Corradi,
A. De Santis,
G. De Zorzi,
A. Di Domenico,
S. Fiore,
P. Gauzzi,
M. Iannarelli,
S. Miscetti,
C. Paglia,
D. Tagnani,
E. Turri
Abstract:
The KLOE experiment at the upgraded DAFNE e+e- collider in Frascati (KLOE-2) is going to start a new data taking at the beginning of 2010 with its detector upgraded with a tagging system for the identification of gamma-gamma interactions. The tagging stations for low-energy e+e- will consist in two calorimeters The calorimeter used to detect low-energy e+e- will be placed between the beam-pipe o…
▽ More
The KLOE experiment at the upgraded DAFNE e+e- collider in Frascati (KLOE-2) is going to start a new data taking at the beginning of 2010 with its detector upgraded with a tagging system for the identification of gamma-gamma interactions. The tagging stations for low-energy e+e- will consist in two calorimeters The calorimeter used to detect low-energy e+e- will be placed between the beam-pipe outer support structure and the inner wall of the KLOE drift chamber. This calorimeter will be made of LYSO crystals readout by Silicon Photomultipliers, to achieve an energy resolution better than 8% at 200 MeV.
△ Less
Submitted 4 June, 2009;
originally announced June 2009.