-
Megahertz single-particle imaging at the European XFEL
Authors:
Egor Sobolev,
Serguey Zolotarev,
Klaus Giewekemeyer,
Johan Bielecki,
Kenta Okamoto,
Hemanth K. N. Reddy,
Jakob Andreasson,
Kartik Ayyer,
Imrich Barak,
Sadia Bari,
Anton Barty,
Richard Bean,
Sergey Bobkov,
Henry N. Chapman,
Grzegorz Chojnowski,
Benedikt J. Daurer,
Katerina Dörner,
Tomas Ekeberg,
Leonie Flückiger,
Oxana Galzitskaya,
Luca Gelisio,
Steffen Hauf,
Brenda G. Hogue,
Daniel A. Horke,
Ahmad Hosseinizadeh
, et al. (38 additional authors not shown)
Abstract:
The emergence of high repetition-rate X-ray free-electron lasers (XFELs) powered by superconducting accelerator technology enables the measurement of significantly more experimental data per day than was previously possible. The European XFEL will soon provide 27,000 pulses per second, more than two orders of magnitude more than any other XFEL. The increased pulse rate is a key enabling factor for…
▽ More
The emergence of high repetition-rate X-ray free-electron lasers (XFELs) powered by superconducting accelerator technology enables the measurement of significantly more experimental data per day than was previously possible. The European XFEL will soon provide 27,000 pulses per second, more than two orders of magnitude more than any other XFEL. The increased pulse rate is a key enabling factor for single-particle X-ray diffractive imaging, which relies on averaging the weak diffraction signal from single biological particles. Taking full advantage of this new capability requires that all experimental steps, from sample preparation and delivery to the acquisition of diffraction patterns, are compatible with the increased pulse repetition rate. Here, we show that single-particle imaging can be performed using X-ray pulses at megahertz repetition rates. The obtained results pave the way towards exploiting high repetition-rate X-ray free-electron lasers for single-particle imaging at their full repetition rate.
△ Less
Submitted 14 December, 2019;
originally announced December 2019.
-
The Adaptive Gain Integrating Pixel Detector at the European XFEL
Authors:
Aschkan Allahgholi,
Julian Becker,
Annette Delfs,
Roberto Dinapoli,
Peter Goettlicher,
Dominic Greiffenberg,
Beat Henrich,
Helmut Hirsemann,
Manuela Kuhn,
Robert Klanner,
Alexander Klyuev,
Hans Krueger,
Sabine Lange,
Torsten Laurus,
Alessandro Marras,
Davide Mezza,
Aldo Mozzanica,
Magdalena Niemann,
Jennifer Poehlsen,
Joern Schwandt,
Igor Sheviakov,
Xintian Shi,
Sergej Smoljanin,
Lothar Steffen,
Jolanta Sztuk-Dambietz
, et al. (7 additional authors not shown)
Abstract:
The Adaptive Gain Integrating Pixel Detector (AGIPD) is an x-ray imager, custom designed for the European x-ray Free-Electron Laser (XFEL). It is a fast, low noise integrating detector, with an adaptive gain amplifier per pixel. This has an equivalent noise of less than 1 keV when detecting single photons and, when switched into another gain state, a dynamic range of more than 10$^4$ photons of 12…
▽ More
The Adaptive Gain Integrating Pixel Detector (AGIPD) is an x-ray imager, custom designed for the European x-ray Free-Electron Laser (XFEL). It is a fast, low noise integrating detector, with an adaptive gain amplifier per pixel. This has an equivalent noise of less than 1 keV when detecting single photons and, when switched into another gain state, a dynamic range of more than 10$^4$ photons of 12 keV. In burst mode the system is able to store 352 images while running at up to 6.5 MHz, which is compatible with the 4.5 MHz frame rate at the European XFEL. The AGIPD system was installed and commissioned in August 2017, and successfully used for the first experiments at the Single Particles, Clusters and Biomolecules (SPB) experimental station at the European XFEL since September 2017. This paper describes the principal components and performance parameters of the system.
△ Less
Submitted 2 October, 2018; v1 submitted 1 August, 2018;
originally announced August 2018.
-
Status of the laboratory infrastructure for detector calibration and characterization at the European XFEL
Authors:
N. Raab,
K. -E. Ballak,
T. Dietze,
M. Ekmedzič,
S. Hauf,
F. Januschek,
A. Kaukher,
M. Kuster,
P. M. Lang,
A. Münnich,
R. Schmitt,
J. Sztuk-Dambietz,
M. Turcato
Abstract:
The European X-ray Free Electron Laser (XFEL.EU) will provide unprecedented peak brilliance and ultra-short and spatially coherent X-ray pulses in an energy range of 0.25 to 25 keV . The pulse timing structure is unique with a burst of 2700 pulses of 100 fs length at a temporal distance of 220 ns followed by a 99.4 ms gap. To make optimal use of this timing structure and energy range a great varie…
▽ More
The European X-ray Free Electron Laser (XFEL.EU) will provide unprecedented peak brilliance and ultra-short and spatially coherent X-ray pulses in an energy range of 0.25 to 25 keV . The pulse timing structure is unique with a burst of 2700 pulses of 100 fs length at a temporal distance of 220 ns followed by a 99.4 ms gap. To make optimal use of this timing structure and energy range a great variety of detectors are being developed for use at XFEL.EU, including 2D X-ray imaging cameras that are able to detect images at a rate of 4.5 MHz, provide dynamic ranges up to 10$^5$ photons per pulse per pixel under different operating conditions and covering a large range of angular resolution. In order to characterize, commission and calibrate this variety of detectors and for testing of detector prototypes the XFEL.EU detector group is building up an X-ray test laboratory that allows testing of detectors with X-ray photons under conditions that are as similar to the future beam line conditions at the XFEL.EU as is possible with laboratory sources. A total of four test environments provide the infrastructure for detector tests and calibration: two portable setups that utilize low power X-ray sources and radioactive isotopes, a test environment where a commercial high power X-ray generator is in use, and a pulsed X-ray/electron source which will provide pulses as short as 25 ns in XFEL.EU burst mode combined with target anodes of different materials. The status of the test environments, three of which are already in use while one is in commissioning phase, will be presented as well as first results from performance tests and characterization of the sources.
△ Less
Submitted 21 March, 2017;
originally announced March 2017.
-
Integrated Detector Control and Calibration Processing at the European XFEL
Authors:
A. Münnich,
S. Hauf,
B. C. Heisen,
F. Januschek,
M. Kuster,
P. M. Lang,
N. Raab,
T. Rüter,
J. Sztuk-Dambietz,
M. Turcato
Abstract:
The European X-ray Free Electron Laser is a high-intensity X-ray light source currently being constructed in the area of Hamburg, that will provide spatially coherent X-rays in the energy range between $0.25\,\mathrm{keV}$ and $25\,\mathrm{keV}$. The machine will deliver $10\,\mathrm{trains/s}$, consisting of up to $2700\,\mathrm{pulses}$, with a $4.5\,\mathrm{MHz}$ repetition rate. The LPD, DSSC…
▽ More
The European X-ray Free Electron Laser is a high-intensity X-ray light source currently being constructed in the area of Hamburg, that will provide spatially coherent X-rays in the energy range between $0.25\,\mathrm{keV}$ and $25\,\mathrm{keV}$. The machine will deliver $10\,\mathrm{trains/s}$, consisting of up to $2700\,\mathrm{pulses}$, with a $4.5\,\mathrm{MHz}$ repetition rate. The LPD, DSSC and AGIPD detectors are being developed to provide high dynamic-range Mpixel imaging capabilities at the mentioned repetition rates. A consequence of these detector characteristics is that they generate raw data volumes of up to $15\,\mathrm{Gbyte/s}$. In addition the detector's on-sensor memory-cell and multi-/non-linear gain architectures pose unique challenges in data correction and calibration, requiring online access to operating conditions and control settings. We present how these challenges are addressed within XFEL's control and analysis framework Karabo, which integrates access to hardware conditions, acquisition settings (also using macros) and distributed computing. Implementation of control and calibration software is mainly in Python, using self-optimizing (py) CUDA code, numpy and iPython parallels to achieve near-real time performance for calibration application.
△ Less
Submitted 8 January, 2016;
originally announced January 2016.
-
Performance of an LPD prototype detector at MHz frame rates under Synchrotron and FEL radiation
Authors:
Andreas Koch,
Matthew Hart,
Tim Nicholls,
Christian Angelsen,
John Coughlan,
Marcus French,
Steffen Hauf,
Markus Kuster,
Jolanta Sztuk-Dambietz,
Monica Turcato,
Gabriella A. Carini,
Matthieu Chollet,
Sven C. Herrmann,
Henrik T. Lemke,
Silke Nelson,
Sanghoon Song,
Matt Weaver,
Diling Zhu,
Alke Meents,
Pontus Fischer
Abstract:
A MHz frame rate X-ray area detector (LPD - Large Pixel Detector) is under development by the Rutherford Appleton Laboratory for the European XFEL. The detector will have 1 million pixels and allows analogue storage of 512 images taken at 4.5 MHz in the detector front end. The LPD detector has 500 mm thick silicon sensor tiles that are bump bonded to a readout ASIC. The ASICs preamplifier provides…
▽ More
A MHz frame rate X-ray area detector (LPD - Large Pixel Detector) is under development by the Rutherford Appleton Laboratory for the European XFEL. The detector will have 1 million pixels and allows analogue storage of 512 images taken at 4.5 MHz in the detector front end. The LPD detector has 500 mm thick silicon sensor tiles that are bump bonded to a readout ASIC. The ASICs preamplifier provides relatively low noise at high speed which results in a high dynamic range of 10^5 photons over an energy range of 5-20 keV. Small scale prototypes of 32x256 pixels (LPD 2-Tile detector) and 256x256 pixels (LPD supermodule detector) are now available for X-ray tests. The performance of prototypes of the detector is reported for first tests under synchrotron radiation (PETRA III at DESY) and Free-Electron-Laser radiation (LCLS at SLAC). The initial performance of the detector in terms of signal range and noise, radiation hardness and spatial and temporal response are reported. The main result is that the 4.5 MHz sampling detection chain is reliably working, including the analogue on-chip memory concept. The detector is at least radiation hard up to 5 MGy at 12 keV. In addition the multiple gain concept has been demonstrated over a dynamic range to 10^4 at 12 keV with a readout noise equivalent to <1 photon rms in its most sensitive mode.
△ Less
Submitted 7 November, 2013;
originally announced November 2013.
-
Measurement of the Luminosity in the ZEUS Experiment at HERA II
Authors:
L. Adamczyk,
J. Andruszkow,
T. Bold,
P. Borzemski,
C. Buettner,
A. Caldwell,
J. Chwastowski,
W. Daniluk,
V. Drugakov,
A. Eskreys,
J. Figiel,
A. Galas,
M. Gil,
M. Helbich,
F. Januschek,
P. Jurkiewicz,
D. Kisielewska,
U. Klein,
A. Kotarba,
W. Lohmann,
Y. Ning,
K. Oliwa,
K. Olkiewicz,
S. Paganis,
J. Pieron
, et al. (12 additional authors not shown)
Abstract:
The luminosity in the ZEUS detector was measured using photons from electron bremsstrahlung. In 2001 the HERA collider was upgraded for operation at higher luminosity. At the same time the luminosity-measuring system of the ZEUS experiment was modified to tackle the expected higher photon rate and synchrotron radiation. The existing lead-scintillator calorimeter was equipped with radiation hard sc…
▽ More
The luminosity in the ZEUS detector was measured using photons from electron bremsstrahlung. In 2001 the HERA collider was upgraded for operation at higher luminosity. At the same time the luminosity-measuring system of the ZEUS experiment was modified to tackle the expected higher photon rate and synchrotron radiation. The existing lead-scintillator calorimeter was equipped with radiation hard scintillator tiles and shielded against synchrotron radiation. In addition, a magnetic spectrometer was installed to measure the luminosity independently using photons converted in the beam-pipe exit window. The redundancy provided a reliable and robust luminosity determination with a systematic uncertainty of 1.7%. The experimental setup, the techniques used for luminosity determination and the estimate of the systematic uncertainty are reported.
△ Less
Submitted 13 June, 2013; v1 submitted 6 June, 2013;
originally announced June 2013.
-
Status of detector development for the European XFEL
Authors:
Jolanta Sztuk-Dambietz,
Steffen Hauf,
Andreas Koch,
Markus Kuster,
Monica Turcato
Abstract:
The European X-ray Free Electron Laser (XFEL.EU) will provide as-yet-unrivaled peak brilliance and ultra-short pulses of spatially coherent X-rays with a pulse length of less than 100 fs in the energy range between 0.25 and 25 keV. The high radiation intensity and ultra-short pulse duration will open a window for novel scientific techniques and will allow to explore new phenomena in biology, chemi…
▽ More
The European X-ray Free Electron Laser (XFEL.EU) will provide as-yet-unrivaled peak brilliance and ultra-short pulses of spatially coherent X-rays with a pulse length of less than 100 fs in the energy range between 0.25 and 25 keV. The high radiation intensity and ultra-short pulse duration will open a window for novel scientific techniques and will allow to explore new phenomena in biology, chemistry, material science, as well as matter at high energy density, atomic, ion and molecular physics. The variety of scientific applications and especially the unique XFEL.EU time structure require adequate instrumentation to be developed in order to exploit the full potential of the light source. To make optimal use of the unprecedented capabilities of the European XFEL and master these vast technological challenges, the European XFEL GmbH has started a detector R&D program. The technology concepts of the detector system presently under development are complementary in their performance and will cover the requirements of a large fraction of the scientific applications envisaged for the XFEL.EU facility. The actual status of the detector development projects which includes ultra-fast 2D imaging detectors, low repetition rate 2D detectors as well as strip detectors for e.g. spectroscopy applications and the infrastructure for the detectors' calibration and tests will be presented. Furthermore, an overview of the forthcoming implementation phase of the European XFEL in terms of detector R&D will be given.
△ Less
Submitted 24 April, 2013;
originally announced April 2013.
-
Detector Development for the European XFEL: Requirements and Status
Authors:
Andreas Koch,
Markus Kuster,
Jolanta Sztuk-Dambietz,
Monica Turcato
Abstract:
The variety of applications and especially the unique European XFEL time structure will require adequate instrumentation to be developed to exploit the full potential of the light source. Two-dimensional integrating X-ray detectors with ultra-fast read out up to 4.5 MHz for 1024 x 1024 pixel images are under development for a variety of imaging applications. The actual status of the European XFEL…
▽ More
The variety of applications and especially the unique European XFEL time structure will require adequate instrumentation to be developed to exploit the full potential of the light source. Two-dimensional integrating X-ray detectors with ultra-fast read out up to 4.5 MHz for 1024 x 1024 pixel images are under development for a variety of imaging applications. The actual status of the European XFEL detector development projects is presented. Furthermore, an outlook will be given with respect to detector research and development, performance optimization, integration, and commissioning.
△ Less
Submitted 29 October, 2012; v1 submitted 5 October, 2012;
originally announced October 2012.