-
Reactor Antineutrino Directionality Measurement with the PROSPECT-I Detector
Authors:
M. Andriamirado,
B. Balantekin,
C. D. Bass,
O. Benevides Rodrigues,
E. P. Bernard,
N. S. Bowden,
C. D. Bryan,
R. Carr,
T. Classen,
A. J. Conant,
G. Deichert,
M. J. Dolinski,
A. Erickson,
A. Galindo-Uribarri,
S. Gokhale,
C. Grant,
S. Hans,
A. B. Hansell,
K. M. Heeger,
B. Heffron,
D. E. Jaffe,
S. Jayakumar,
D. C. Jones,
J. R. Koblanski,
P. Kunkle
, et al. (24 additional authors not shown)
Abstract:
The PROSPECT-I detector has several features that enable measurement of the direction of a compact neutrino source. In this paper, a detailed report on the directional measurements made on electron antineutrinos emitted from the High Flux Isotope Reactor is presented. With an estimated true neutrino (reactor to detector) direction of $φ= 40.8\unicode{xB0} \pm 0.7\unicode{xB0}$ and…
▽ More
The PROSPECT-I detector has several features that enable measurement of the direction of a compact neutrino source. In this paper, a detailed report on the directional measurements made on electron antineutrinos emitted from the High Flux Isotope Reactor is presented. With an estimated true neutrino (reactor to detector) direction of $φ= 40.8\unicode{xB0} \pm 0.7\unicode{xB0}$ and $θ= 98.6\unicode{xB0} \pm 0.4\unicode{xB0}$, the PROSPECT-I detector is able to reconstruct an average neutrino direction of $φ= 39.4\unicode{xB0} \pm 2.9\unicode{xB0}$ and $θ= 97.6\unicode{xB0} \pm 1.6\unicode{xB0}$. This measurement is made with approximately 48000 Inverse Beta Decay signal events and is the most precise directional reconstruction of reactor antineutrinos to date.
△ Less
Submitted 11 July, 2024; v1 submitted 12 June, 2024;
originally announced June 2024.
-
Performance of large-scale 6Li-doped pulse-shape discriminating plastic scintillators
Authors:
C. Roca,
N. S. Bowden,
L. Carman,
S. A. Dazeley,
S. R. Durham,
O. M. Falana,
M. J. Ford,
A. M. Glenn,
C. Hurlbut,
V. A. Li,
M. P. Mendenhall,
K. Shipp,
F. Sutanto,
N. P. Zaitseva
Abstract:
A $^6$Li-doped plastic scintillator with pulse-shape discrimination capabilities, commercially identified as EJ-299-50, has been developed and produced at the kilogram-scale. A total of 44 kg-scale bars of dimensions 5.5 cm $\times$ 5.5 cm $\times$ 50 cm of this material have been characterized. Optical properties like light output and effective attenuation length have been found to be comparable…
▽ More
A $^6$Li-doped plastic scintillator with pulse-shape discrimination capabilities, commercially identified as EJ-299-50, has been developed and produced at the kilogram-scale. A total of 44 kg-scale bars of dimensions 5.5 cm $\times$ 5.5 cm $\times$ 50 cm of this material have been characterized. Optical properties like light output and effective attenuation length have been found to be comparable to $^6$Li-doped liquid scintillators. The scintillator EJ-299-50 shows good neutron detection capabilities with an effective efficiency for capture on $^6$Li of approximately 85%. Stability tests performed on two formulation variations showed no intrinsic degradation in the material or optical properties during several months of observations.
△ Less
Submitted 29 May, 2024;
originally announced May 2024.
-
$^6$Li-loaded liquid scintillators produced by direct dissolution of compounds in diisopropylnaphthalene (DIPN)
Authors:
N. P. Zaitseva,
M. L. Carman,
M. J. Ford,
A. M. Glenn,
C. Roca,
S. Durham,
F. Sutanto,
S. A. Dazeley,
N. S. Bowden
Abstract:
The paper describes preparation of $^6$Li-loaded liquid scintillators by methods involving direct dissolution of $^6$Li salts in the commercial diisopropylnaphthalene (DIPN) solvent, without the formation of water-in-oil emulsions. Methods include incorporation of $^6$Li that, unlike previously reported formulations, does not require additions of water or a strong acid such as hydrochloric acid (H…
▽ More
The paper describes preparation of $^6$Li-loaded liquid scintillators by methods involving direct dissolution of $^6$Li salts in the commercial diisopropylnaphthalene (DIPN) solvent, without the formation of water-in-oil emulsions. Methods include incorporation of $^6$Li that, unlike previously reported formulations, does not require additions of water or a strong acid such as hydrochloric acid (HCl). Results of the conducted experiments show that dissolution of aromatic and aliphatic $^6$Li salts in DIPN can be easily achieved at 0.1- 0.3% by weight of atomic $^6$Li, using small additions of waterless surfactants, or mild carboxylic acids. An alternative way suggests incorporation of $^6$Li as a part of a surfactant molecule that can be dissolved in DIPN without any solubilizing additions. Proposed methods enable preparation of efficient $^6$Li-loaded liquid scintillators that, at a large scale of 50 cm, exhibit good pulse shape discrimination (PSD) properties combined with up to 107% of light output and up to 115% of the attenuation length measured relative to standard undoped EJ-309 liquid scintillator.
△ Less
Submitted 13 June, 2024; v1 submitted 28 March, 2023;
originally announced March 2023.
-
Synthesis and processing of lithium-loaded plastic scintillators on the kilogram scale
Authors:
Michael J. Ford,
Elisabeth Aigeldinger,
Felicia Sutanto,
Natalia P. Zaitseva,
Viacheslav A. Li,
M. Leslie Carman,
Andrew Glenn,
Cristian R. Catala,
Steven A. Dazeley,
Nathaniel Bowden
Abstract:
Plastic scintillators that can discriminate between gamma rays, fast neutrons, and thermal neutrons were synthesized and characterized while considering the balance between processing and performance at the kilogram scale. These trade-offs were necessitated by the inclusion of 0.1 wt. % lithium-6 to enable detection of thermal neutrons. The synthesis and processing of these plastic scintillators o…
▽ More
Plastic scintillators that can discriminate between gamma rays, fast neutrons, and thermal neutrons were synthesized and characterized while considering the balance between processing and performance at the kilogram scale. These trade-offs were necessitated by the inclusion of 0.1 wt. % lithium-6 to enable detection of thermal neutrons. The synthesis and processing of these plastic scintillators on the kilogram scale required consideration of many factors. First, a comonomer (methacrylic acid) was used to solubilize salts of lithium-6, which allow for a thermal-neutron capture reaction that produces scintillation light following energy transfer. Second, scintillation performance and processability were considered because the increasing content of the comonomer resulted in a sharp decrease in the light output. The use of small amounts of comonomer (less than or equal to 3 wt. %) resulted in better performance but required high processing temperatures. At large scales, these high temperatures could initiate an exothermic polymerization that results in premature curing and/or defects. The deleterious effects of the comonomer may be mitigated by using m-terphenyl as a primary dye rather than 2,5-diphenyloxazole (PPO), which has been traditionally used in organic scintillators. Finally, the curing environment was controlled to avoid defects like cracking and discoloration while maintaining solubility of dopants during curing. For scintillators that were produced from kilogram-scale batches of precursors, the effective attenuation of scintillation light was characterized.
△ Less
Submitted 10 January, 2023;
originally announced January 2023.
-
Calibration strategy of the PROSPECT-II detector with external and intrinsic sources
Authors:
M. Andriamirado,
A. B. Balantekin,
C. D. Bass,
D. E. Bergeron,
E. P. Bernard,
N. S. Bowden,
C. D. Bryan,
R. Carr,
T. Classen,
A. J. Conant,
A. Delgado,
M. V. Diwan,
M. J. Dolinski,
A. Erickson,
B. T. Foust,
J. K. Gaison,
A. Galindo-Uribarri,
C. E. Gilbert,
S. Gokhale,
C. Grant,
S. Hans,
A. B. Hansell,
K. M. Heeger,
B. Heffron,
D. E. Jaffe
, et al. (36 additional authors not shown)
Abstract:
This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector, PROSPECT-II (P-II), to advance capabilities for the investigation of fundamental neutrino physics, fission processes and associated reactor neutrino flux, and nuclear se…
▽ More
This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector, PROSPECT-II (P-II), to advance capabilities for the investigation of fundamental neutrino physics, fission processes and associated reactor neutrino flux, and nuclear security applications. P-II will expand the statistical power of the original PROSPECT (P-I) dataset by at least an order of magnitude. The new design builds upon previous P-I design and focuses on improving the detector robustness and long-term stability to enable multi-year operation at one or more sites. The new design optimizes the fiducial volume by elimination of dead space previously occupied by internal calibration channels, which in turn necessitates the external deployment. In this paper, we describe a calibration strategy for P-II. The expected performance of externally deployed calibration sources is evaluated using P-I data and a well-benchmarked simulation package by varying detector segmentation configurations in the analysis. The proposed external calibration scheme delivers a compatible energy scale model and achieves comparable performance with the inclusion of an additional AmBe neutron source, in comparison to the previous internal arrangement. Most importantly, the estimated uncertainty contribution from the external energy scale calibration model meets the precision requirements of the P-II experiment.
△ Less
Submitted 10 April, 2023; v1 submitted 17 November, 2022;
originally announced November 2022.
-
Exclusion and Verification of Remote Nuclear Reactors with a 1-Kiloton Gd-Doped Water Detector
Authors:
O. A. Akindele,
A. Bernstein,
M. Bergevin,
S. A. Dazeley,
F. Sutanto,
A. Mullen,
J. Hecla
Abstract:
To date, antineutrino experiments built for the purpose of demonstrating a nonproliferation capability have typically employed organic scintillators, were situated as close to the core as possible -typically a few meters to tens of meters distant and have not exceeded a few tons in size. One problem with this approach is that proximity to the reactor core require accommodation by the host facility…
▽ More
To date, antineutrino experiments built for the purpose of demonstrating a nonproliferation capability have typically employed organic scintillators, were situated as close to the core as possible -typically a few meters to tens of meters distant and have not exceeded a few tons in size. One problem with this approach is that proximity to the reactor core require accommodation by the host facility. Water Cherenkov detectors located offsite, at distances of a few kilometers or greater, may facilitate non-intrusive monitoring and verification of reactor activities over a large area. As the standoff distance increases, the detector target mass must scale accordingly. This article quantifies the degree to which a kiloton-scale gadolinium-doped water-Cherenkov detector can exclude the existence of undeclared reactors within a specified distance, and remotely detect the presence of a hidden reactor in the presence of declared reactors, by verifying the operational power and standoff distance using a Feldman-Cousins based likelihood analysis. A 1-kton scale (fiducial) water Cherenkov detector can exclude gigawatt-scale nuclear reactors up to tens of kilometers within a year. When attempting to identify the specific range and power of a reactor, the detector energy resolution was not sufficient to delineate between the two.
△ Less
Submitted 17 October, 2022;
originally announced October 2022.
-
Production and suppression of delayed light in NaI
Authors:
F. Sutanto,
J. Xu,
S. Pereverzev,
A. Bernstein
Abstract:
We investigate a hypothesis that energy accumulation and the subsequent release in NaI(Tl) may lead to pulse-like events in the few-keV energy regime, a phenomenon suggested by the crystal manufacturing company Saint-Gobain, who provided the crystals for DAMA-LIBRA. While we observed delayed long-lasting light emission in a 3" NaI(Tl) crystal after exposing it to UV light, the delayed light consis…
▽ More
We investigate a hypothesis that energy accumulation and the subsequent release in NaI(Tl) may lead to pulse-like events in the few-keV energy regime, a phenomenon suggested by the crystal manufacturing company Saint-Gobain, who provided the crystals for DAMA-LIBRA. While we observed delayed long-lasting light emission in a 3" NaI(Tl) crystal after exposing it to UV light, the delayed light consists primarily of single photons that are uncorrelated with each other. We also observe delayed light emission in NaI(Tl) following gamma radiation and large ionization events like cosmic-ray muons. We found that irradiating the crystal with red light after UV exposure significantly suppressed delayed photon emissions.
△ Less
Submitted 31 December, 2022; v1 submitted 21 August, 2022;
originally announced August 2022.
-
White Paper on Light Sterile Neutrino Searches and Related Phenomenology
Authors:
M. A. Acero,
C. A. Argüelles,
M. Hostert,
D. Kalra,
G. Karagiorgi,
K. J. Kelly,
B. Littlejohn,
P. Machado,
W. Pettus,
M. Toups,
M. Ross-Lonergan,
A. Sousa,
P. T. Surukuchi,
Y. Y. Y. Wong,
W. Abdallah,
A. M. Abdullahi,
R. Akutsu,
L. Alvarez-Ruso,
D. S. M. Alves,
A. Aurisano,
A. B. Balantekin,
J. M. Berryman,
T. Bertólez-Martínez,
J. Brunner,
M. Blennow
, et al. (147 additional authors not shown)
Abstract:
This white paper provides a comprehensive review of our present understanding of experimental neutrino anomalies that remain unresolved, charting the progress achieved over the last decade at the experimental and phenomenological level, and sets the stage for future programmatic prospects in addressing those anomalies. It is purposed to serve as a guiding and motivational "encyclopedic" reference,…
▽ More
This white paper provides a comprehensive review of our present understanding of experimental neutrino anomalies that remain unresolved, charting the progress achieved over the last decade at the experimental and phenomenological level, and sets the stage for future programmatic prospects in addressing those anomalies. It is purposed to serve as a guiding and motivational "encyclopedic" reference, with emphasis on needs and options for future exploration that may lead to the ultimate resolution of the anomalies. We see the main experimental, analysis, and theory-driven thrusts that will be essential to achieving this goal being: 1) Cover all anomaly sectors -- given the unresolved nature of all four canonical anomalies, it is imperative to support all pillars of a diverse experimental portfolio, source, reactor, decay-at-rest, decay-in-flight, and other methods/sources, to provide complementary probes of and increased precision for new physics explanations; 2) Pursue diverse signatures -- it is imperative that experiments make design and analysis choices that maximize sensitivity to as broad an array of these potential new physics signatures as possible; 3) Deepen theoretical engagement -- priority in the theory community should be placed on development of standard and beyond standard models relevant to all four short-baseline anomalies and the development of tools for efficient tests of these models with existing and future experimental datasets; 4) Openly share data -- Fluid communication between the experimental and theory communities will be required, which implies that both experimental data releases and theoretical calculations should be publicly available; and 5) Apply robust analysis techniques -- Appropriate statistical treatment is crucial to assess the compatibility of data sets within the context of any given model.
△ Less
Submitted 17 May, 2023; v1 submitted 14 March, 2022;
originally announced March 2022.
-
A Call to Arms Control: Synergies between Nonproliferation Applications of Neutrino Detectors and Large-Scale Fundamental Neutrino Physics Experiments
Authors:
T. Akindele,
T. Anderson,
E. Anderssen,
M. Askins,
M. Bohles,
A. J. Bacon,
Z. Bagdasarian,
A. Baldoni,
A. Barna,
N. Barros,
L. Bartoszek,
A. Bat,
E. W. Beier,
T. Benson,
M. Bergevin,
A. Bernstein,
B. Birrittella,
E. Blucher,
J. Boissevain,
R. Bonventre,
J. Borusinki,
E. Bourret,
D. Brown,
E. J. Callaghan,
J. Caravaca
, et al. (140 additional authors not shown)
Abstract:
The High Energy Physics community can benefit from a natural synergy in research activities into next-generation large-scale water and scintillator neutrino detectors, now being studied for remote reactor monitoring, discovery and exclusion applications in cooperative nonproliferation contexts.
Since approximately 2010, US nonproliferation researchers, supported by the National Nuclear Security…
▽ More
The High Energy Physics community can benefit from a natural synergy in research activities into next-generation large-scale water and scintillator neutrino detectors, now being studied for remote reactor monitoring, discovery and exclusion applications in cooperative nonproliferation contexts.
Since approximately 2010, US nonproliferation researchers, supported by the National Nuclear Security Administration (NNSA), have been studying a range of possible applications of relatively large (100 ton) to very large (hundreds of kiloton) water and scintillator neutrino detectors.
In parallel, the fundamental physics community has been develo** detectors at similar scales and with similar design features for a range of high-priority physics topics, primarily in fundamental neutrino physics. These topics include neutrino oscillation studies at beams and reactors, solar, and geological neutrino measurements, supernova studies, and others.
Examples of ongoing synergistic work at U.S. national laboratories and universities include prototype gadolinium-doped water and water-based and opaque scintillator test-beds and demonstrators, extensive testing and industry partnerships related to large area fast position-sensitive photomultiplier tubes, and the development of concepts for a possible underground kiloton-scale water-based detector for reactor monitoring and technology demonstrations.
Some opportunities for engagement between the two communities include bi-annual Applied Antineutrino Physics conferences, collaboration with U.S. National Laboratories engaging in this research, and occasional NNSA funding opportunities supporting a blend of nonproliferation and basic science R&D, directed at the U.S. academic community.
△ Less
Submitted 20 April, 2022; v1 submitted 28 February, 2022;
originally announced March 2022.
-
Evaluation of a Positron-Emission-Tomography-based SiPM readout for Compact Segmented Neutron Imagers
Authors:
Viacheslav A. Li,
Felicia Sutanto,
Timothy M. Classen,
Steven A. Dazeley,
Igor Jovanovic,
Tingshiuan C. Wu
Abstract:
Gamma-ray emission from special nuclear material (SNM) is relatively easy to shield from detection using modest amounts of high-Z material. In contrast, fast-neutrons are much more penetrating and can escape relatively thick high-Z shielding without losing significant energy. Furthermore, fast neutrons provide a clear and unambiguous signature of the presence of SNM with few competing natural back…
▽ More
Gamma-ray emission from special nuclear material (SNM) is relatively easy to shield from detection using modest amounts of high-Z material. In contrast, fast-neutrons are much more penetrating and can escape relatively thick high-Z shielding without losing significant energy. Furthermore, fast neutrons provide a clear and unambiguous signature of the presence of SNM with few competing natural background sources. The challenge of detecting fast neutrons is twofold. First, the neutron flux from SNM are only a fraction of the corresponding gamma-ray flux. Second, fast neutrons can be difficult to differentiate from gamma rays. The ability to discriminate gamma rays from neutrons combined with neutron imaging can yield large benefit to isolate the localized SNM neutron source from background. With the recent developments of pulse-shape-sensitive plastic scintillators that offer excellent gamma-ray/neutron discrimination, and arrays of silicon photomultipliers combined with highly scalable and fast positron-emission-tomography (PET) multi-channel readout systems, field-deployable neutron imagers suitable for SNM detection might now be within reach. In this paper, we present a characterization of the performance of a recently available commercial PET-scanner readout, including its sensitivity to pulse-shape differences between fast neutrons and gamma rays, energy and timing resolution, as well as linearity and dynamic range. We find that, while the pulse-shape discrimination is achievable with stilbene, further improvement of the readout is required to achieve it with the best available plastic scintillators. The time and energy resolution appear to be adequate for neutron imaging in some circumstances.
△ Less
Submitted 15 February, 2022;
originally announced February 2022.
-
SANDD: A directional antineutrino detector with segmented 6Li-doped pulse-shape-sensitive plastic scintillator
Authors:
F. Sutanto,
T. M. Classen,
S. A. Dazeley,
M. J. Duvall,
I. Jovanovic,
V. A. Li,
A. N. Mabe,
E. T. E. Reedy,
T. Wu
Abstract:
We present a characterization of a small (9-liter) and mobile 0.1% 6Li-doped pulse-shape-sensitive plastic scintillator antineutrino detector called SANDD (Segmented AntiNeutrino Directional Detector), constructed for the purpose of near-field reactor monitoring with sensitivity to antineutrino direction. SANDD comprises three different types of module. A detailed Monte Carlo simulation code was d…
▽ More
We present a characterization of a small (9-liter) and mobile 0.1% 6Li-doped pulse-shape-sensitive plastic scintillator antineutrino detector called SANDD (Segmented AntiNeutrino Directional Detector), constructed for the purpose of near-field reactor monitoring with sensitivity to antineutrino direction. SANDD comprises three different types of module. A detailed Monte Carlo simulation code was developed to match and validate the performance of each of the three modules. The combined model was then used to produce a prediction of the performance of the entire detector. Analysis cuts were established to isolate antineutrino inverse beta decay events while rejecting large fraction of backgrounds. The neutron and positron detection efficiencies are estimated to be 34.8% and 80.2%, respectively, while the coincidence detection efficiency is estimated to be 71.7%, resulting in inverse beta decay detection efficiency of 20.05 +/- 0.2%(stat.) +/- 2.1%(syst.). The predicted directional sensitivity of SANDD produces an uncertainty of 20 degree in the azimuthal direction per 100 detected antineutrino events.
△ Less
Submitted 30 April, 2021;
originally announced May 2021.
-
Measurement of Muon-induced High-energy Neutrons from Rock in an Underground Gd-doped Water Detector
Authors:
F. Sutanto,
O. A. Akindele,
M. Askins,
M. Bergevin,
A. Bernstein,
N. S. Bowden,
S. Dazeley,
P. Jaffke,
I. Jovanovic,
S. Quillin,
C. Roecker,
S. D. Rountree
Abstract:
We present a measurement of the rate of correlated neutron captures in the WATCHBOY detector, deployed at a depth of approximately 390 meters water equivalent (m.w.e.) in the Kimballton Underground Research Facility (KURF). WATCHBOY consists of a cylindrical 2 ton water target doped with 0.1% gadolinium, surrounded by a 40 ton undoped water hermetic shield. We present a comparison of our results w…
▽ More
We present a measurement of the rate of correlated neutron captures in the WATCHBOY detector, deployed at a depth of approximately 390 meters water equivalent (m.w.e.) in the Kimballton Underground Research Facility (KURF). WATCHBOY consists of a cylindrical 2 ton water target doped with 0.1% gadolinium, surrounded by a 40 ton undoped water hermetic shield. We present a comparison of our results with the expected rate of correlated neutron captures arising from high-energy neutrons incident on the outside of the WATCHBOY shield, predicted by a hybrid FLUKA/GEANT4-based simulation. The incident neutron energy distribution used in the simulation was measured by a fast neutron spectrometer, the 1.8-ton Multiplicity and Recoil Spectrometer (MARS) detector, at the same depth. We find that the measured detection rate of two correlated neutrons is consistent with that predicted by simulation. The result lends additional confidence in the detection technique used by MARS, and therefore in the MARS spectra as measured at three different depths. Confirmation of the fast neutron flux and spectrum is important as it helps validate the scaling models used to predict the fast neutron fluxes at different overburdens.
△ Less
Submitted 30 August, 2020;
originally announced August 2020.
-
Characterization of the $^{12}$C(p,p')$^{12}$C Reaction (E$_p$=19.5$-$30 MeV) for Active Interrogation
Authors:
J. Nattress,
F. Sutanto,
P. -W. Fang,
Y. -Z. Chen,
A. Chen,
K. -Y. Chu,
T. S. Duh,
H. -Y. Tsai,
M. -W. Lin,
I. Jovanovic
Abstract:
Passive detection of special nuclear material (SNM) is challenging due to its inherently low rate of spontaneous emission of penetrating radiation, the relative ease of shielding, and the fluctuating and frequently overwhelming background. Active interrogation (AI), the use of external radiation to increase the emission rate of characteristic radiation from SNM, has long been considered to be a pr…
▽ More
Passive detection of special nuclear material (SNM) is challenging due to its inherently low rate of spontaneous emission of penetrating radiation, the relative ease of shielding, and the fluctuating and frequently overwhelming background. Active interrogation (AI), the use of external radiation to increase the emission rate of characteristic radiation from SNM, has long been considered to be a promising method to overcome those challenges. Current AI systems that incorporate radiography tend to use bremsstrahlung beams, which can deliver high radiation doses. Low-energy ion-driven nuclear reactions that produce multiple monoenergetic photons may be used as an alternative. The $^{12}$C(p,p')$^{12}$C is one such reaction that could produce large gamma-ray yields of highly penetrating 4.4- and 15.1-MeV gamma rays. This reaction does not directly produce neutrons below the $\sim$19.7-MeV threshold, and the 15.1-MeV gamma-ray line is well matched to the photofission cross-section of $^{235}$U and $^{238}$U. We report the measurements of thick-target gamma-ray yields at 4.4 and 15.1 MeV from the $^{12}$C(p,p')$^{12}$C at proton energies of 19.5, 25, and 30 MeV. Measurements were made with two 3'' EJ309 cylindrical liquid scintillation detectors and thermoluminescent dosimeters placed at 0 and 90 degrees. We estimate the highest yields of the 4.4- and 15.1-MeV gamma rays of 1.65$\times10^{10}$ sr$^{-1}μ$ C$^{-1}$ and 4.47$\times10^8$ sr$^{-1}μ$ C$^{-1}$ at a proton energy of 30 MeV, respectively. The yield of 4.4 and 15.1 MeV gamma rays in all experimental configurations is greater than a comparable deuteron-driven reaction that produces the same gamma-ray energies- $^{11}$B(d,n$γ$)$^{12}$C. However, a two orders of magnitude increase of the neutron radiation dose is observed when the proton energy increases from 19.5 to 30 MeV.
△ Less
Submitted 27 May, 2020; v1 submitted 13 November, 2019;
originally announced November 2019.
-
Directionally Accelerated Detection of an Unknown Second Reactor with Antineutrinos for Mid-Field Nonproliferation Monitoring
Authors:
D. L. Danielson,
O. A. Akindele,
M. Askins,
M. Bergevin,
A. Bernstein,
J. Burns,
A. Carroll,
J. Coleman,
R. Collins,
C. Connor,
D. F. Cowen,
F. Dalnoki-Veress,
S. Dazeley,
M. V. Diwan,
J. Duron,
S. T. Dye,
J. Eisch,
A. Ezeribe,
V. Fischer,
R. Foster,
K. Frankiewicz,
C. Grant,
J. Gribble,
J. He,
C. Holligan
, et al. (45 additional authors not shown)
Abstract:
When monitoring a reactor site for nuclear nonproliferation purposes, the presence of an unknown or hidden nuclear reactor could be obscured by the activities of a known reactor of much greater power nearby. Thus when monitoring reactor activities by the observation of antineutrino emissions, one must discriminate known background reactor fluxes from possible unknown reactor signals under investig…
▽ More
When monitoring a reactor site for nuclear nonproliferation purposes, the presence of an unknown or hidden nuclear reactor could be obscured by the activities of a known reactor of much greater power nearby. Thus when monitoring reactor activities by the observation of antineutrino emissions, one must discriminate known background reactor fluxes from possible unknown reactor signals under investigation. To quantify this discrimination, we find the confidence to reject the (null) hypothesis of a single proximal reactor, by exploiting directional antineutrino signals in the presence of a second, unknown reactor. In particular, we simulate the inverse beta decay (IBD) response of a detector filled with a 1 kT fiducial mass of Gadolinium-doped liquid scintillator in mineral oil. We base the detector geometry on that of WATCHMAN, an upcoming antineutrino monitoring experiment soon to be deployed at the Boulby mine in the United Kingdom whose design and deployment will be detailed in a forthcoming white paper. From this simulation, we construct an analytical model of the IBD event distribution for the case of one $4\mathrm{\ GWt}\pm2\%$ reactor 25 km away from the detector site, and for an additional, unknown, 35 MWt reactor 3 to 5 km away. The effects of natural-background rejection cuts are approximated. Applying the model, we predict $3σ$ confidence to detect the presence of an unknown reactor within five weeks, at standoffs of 3 km or nearer. For more distant unknown reactors, the $3σ$ detection time increases significantly. However, the relative significance of directional sensitivity also increases, providing up to an eight week speedup to detect an unknown reactor at 5 km away. Therefore, directionally sensitive antineutrino monitoring can accelerate the mid-field detection of unknown reactors whose operation might otherwise be masked by more powerful reactors in the vicinity.
△ Less
Submitted 10 September, 2019;
originally announced September 2019.
-
A prototype for SANDD: A highly-segmented pulse-shape-sensitive plastic scintillator detector incorporating silicon photomultiplier arrays
Authors:
Viacheslav A. Li,
Timothy M. Classen,
Steven A. Dazeley,
Mark J. Duvall,
Igor Jovanovic,
Andrew N. Mabe,
Edward T. E. Reedy,
Felicia Sutanto
Abstract:
We report the first clear observation of neutron/gamma-ray pulse-shape sensitivity of a fully-instrumented 8 $\times$ 8 array of plastic scintillator segments coupled to two 5 cm $\times$ 5 cm 64-channel SiPM arrays as part of a study of the key metrics of a prototype antineutrino detector module designed for directional sensitivity. SANDD (a Segmented AntiNeutrino Directional Detector) will event…
▽ More
We report the first clear observation of neutron/gamma-ray pulse-shape sensitivity of a fully-instrumented 8 $\times$ 8 array of plastic scintillator segments coupled to two 5 cm $\times$ 5 cm 64-channel SiPM arrays as part of a study of the key metrics of a prototype antineutrino detector module designed for directional sensitivity. SANDD (a Segmented AntiNeutrino Directional Detector) will eventually comprise a central module of 64 elongated segments of $^{6}$Li-doped pulse-shape-sensitive scintillator rods, each with a square cross section of 5.4 mm $\times$ 5.4 mm, surrounded by larger cross section bars of the same material. The most important metrics with the potential to impact the performance of the central module of SANDD are neutron and gamma-ray pulse-shape sensitivity using silicon photomultipliers (SiPMs), particle identification via scintillator rod multiplicity, and energy and position resolution. As a first step, we constructed a prototype detector to investigate the performance of a central SANDD-like module using two 64-channel SiPM arrays and rods of undoped pulse-shape-sensitive plastic scintillator.
△ Less
Submitted 11 August, 2019; v1 submitted 27 March, 2019;
originally announced March 2019.