-
CLARION2-TRINITY: a Compton-suppressed HPGe and GAGG:Ce-Si-Si array for absolute cross-section measurements with heavy ions
Authors:
T. J. Gray,
J. M. Allmond,
D. T. Dowling,
M. Febbraro,
T. T. King,
S. D. Pain,
D. W. Stracener,
S. Ajayi,
J. Aragon,
L. Baby,
P. Barber,
C. Benetti,
S. Bhattacharya,
R. Boisseau,
J. Gibbons,
S. L. Tabor,
V. Tripathi,
C. Wibisono,
I. Wiedenhoever,
L. Bignell,
M. S. M. Gerathy,
G. Lane,
L. J. McKie,
A. J. Mitchell,
J. Pope
, et al. (4 additional authors not shown)
Abstract:
The design and performance of a new Compton-suppressed HPGe and charged-particle array, CLARION2-TRINITY, are described. The TRINITY charged-particle array is comprised of 64 Cerium-doped Gadolinium Aluminium Gallium Garnet (GAGG:Ce) crystals configured into five rings spanning 7-54 degrees, and two annular silicon detectors that can shadow or extend the angular coverage to backward angles with mi…
▽ More
The design and performance of a new Compton-suppressed HPGe and charged-particle array, CLARION2-TRINITY, are described. The TRINITY charged-particle array is comprised of 64 Cerium-doped Gadolinium Aluminium Gallium Garnet (GAGG:Ce) crystals configured into five rings spanning 7-54 degrees, and two annular silicon detectors that can shadow or extend the angular coverage to backward angles with minimal $γ$-ray attenuation. GAGG:Ce is a non-hygroscopic, bright, and relatively fast scintillator with a light distribution well matched to SiPMs. Count rates up to 40 kHz per crystal are sustainable. Fundamental characteristics of GAGG:Ce are measured and presented, including light- and heavy-ion particle identification (PID) capability, pulse-height defects, radiation hardness, and emission spectra. The CLARION2 array consists of up to 16 Compton-suppressed HPGe Clover detectors ($\approx4\%$ efficiency at 1 MeV) configured into four rings (eight HPGe crystal rings) using a non-Archimedean geometry that suppresses back-to-back coincident 511-keV gamma rays. The entire array is instrumented with 100- and 500-MHz (14 bit) waveform digitizers which enable triggerless operation, pulse-shape discrimination, fast timing, and pileup correction. Finally, two examples of experimental data taken during the commissioning of the CLARION2-TRINITY system are given: a PID spectrum from $^{16}$O + $^{18}$O fusion-evaporation, and PID and Doppler-corrected $γ$-ray spectra from $^{48}$Ti + $^{12}$C Coulomb excitation.
△ Less
Submitted 10 August, 2022;
originally announced August 2022.
-
A novel experimental system for the KDK measurement of the $^{40}$K decay scheme relevant for rare event searches
Authors:
M. Stukel,
B. C. Rasco,
N. T. Brewer,
P. C. F. Di Stefano,
K. P. Rykaczewski,
H. Davis,
E. D. Lukosi,
L. Hariasz,
M. Constable,
P. Davis,
K. Dering,
A. Fijałkowska,
Z. Gai,
K. C. Goetz,
R. K. Grzywacz,
J. Kostensalo,
J. Ninkovic,
P. Lechner,
Y. Liu,
M. Mancuso,
C. L. Melcher,
F. Petricca,
C. Rouleau,
P. Squillari,
L. Stand
, et al. (4 additional authors not shown)
Abstract:
Potassium-40 ($^{40}$K) is a long-lived, naturally occurring radioactive isotope. The decay products are prominent backgrounds for many rare event searches, including those involving NaI-based scintillators. $^{40}$K also plays a role in geochronological dating techniques. The branching ratio of the electron capture directly to the ground state of argon-40 has never been measured, which can cause…
▽ More
Potassium-40 ($^{40}$K) is a long-lived, naturally occurring radioactive isotope. The decay products are prominent backgrounds for many rare event searches, including those involving NaI-based scintillators. $^{40}$K also plays a role in geochronological dating techniques. The branching ratio of the electron capture directly to the ground state of argon-40 has never been measured, which can cause difficulty in interpreting certain results or can lead to lack of precision depending on the field and analysis technique. The KDK (Potassium (K) Decay (DK)) collaboration is measuring this decay. A composite method has a silicon drift detector with an enriched, thermally deposited $^{40}$K source inside the Modular Total Absorption Spectrometer. This setup has been characterized in terms of energy calibration, gamma tagging efficiency, live time and false negatives and positives. A complementary, homogeneous, method is also discussed; it employs a KSr$_2$I$_5$:Eu scintillator as source and detector.
△ Less
Submitted 27 July, 2021; v1 submitted 30 December, 2020;
originally announced December 2020.
-
Segmented YSO scintillation detectors as a new ${\rm β}$-implant detection tool for decay spectroscopy in fragmentation facilities
Authors:
R. Yokoyama,
M. Singh,
R. Grzywacz,
A. Keeler,
T. T. King,
J. Agramunt,
N. T. Brewer,
S. Go,
J. Heideman,
J. Liu,
S. Nishimura,
P. Parkhurst,
V. H. Phong,
M. M. Rajabali,
B. C. Rasco,
K. P. Rykaczewski,
D. W. Stracener,
J. L. Tain,
A. Tolosa-Delgado,
K. Vaigneur,
M. Wolińska-Cichocka
Abstract:
A newly developed segmented YSO scintillator detector was implemented for the first time at the RI-beam Factory at RIKEN Nishina Center as an implantation-decay counter. The results from the experiment demonstrate that the detector is a viable alternative to conventional silicon-strip detectors with its good timing resolution and high detection efficiency for ${\rm β}$ particles. A Position-Sensit…
▽ More
A newly developed segmented YSO scintillator detector was implemented for the first time at the RI-beam Factory at RIKEN Nishina Center as an implantation-decay counter. The results from the experiment demonstrate that the detector is a viable alternative to conventional silicon-strip detectors with its good timing resolution and high detection efficiency for ${\rm β}$ particles. A Position-Sensitive Photo-Multiplier Tube (PSPMT) is coupled with a $48\times48$ segmented YSO crystal. To demonstrate its capabilities, a known short-lived isomer in $^{76}$Ni and the ${\rm β}$ decay of $^{74}$Co were measured by implanting those ions into the YSO detector. The half-lives and ${\rm γ}$-rays observed in this work are consistent with the known values. The ${\rm β}$-ray detection efficiency is more than 80~\% for the decay of $^{74}$Co.
△ Less
Submitted 7 May, 2019; v1 submitted 8 March, 2019;
originally announced March 2019.
-
Commissioning of the BRIKEN detector for the measurement of very exotic beta-delayed neutron emitters
Authors:
A. Tolosa-Delgado,
J. Agramunt,
J. L. Tain,
A. Algora,
C. Domingo-Pardo,
A. I. Morales,
B. Rubio,
A. Tarifeno-Saldivia,
F. Calvino,
G. Cortes,
N. T. Brewer,
B. C. Rasco,
K. P. Rykaczewski,
D. W. Stracener,
J. M. Allmond,
R. Grzywacz,
R. Yokoyama,
M. Singh,
T. King,
M. Madurga,
S. Nishimura,
V. H. Phong,
S. Go,
J. Liu,
K. Matsui
, et al. (41 additional authors not shown)
Abstract:
A new detection system has been installed at the RIKEN Nishina Center (Japan) to investigate decay properties of very neutron-rich nuclei. The setup consists of three main parts: a moderated neutron counter, a detection system sensitive to the implantation and decay of radioactive ions, and gamma-ray detectors. We describe here the setup, the commissioning experiment and some selected results demo…
▽ More
A new detection system has been installed at the RIKEN Nishina Center (Japan) to investigate decay properties of very neutron-rich nuclei. The setup consists of three main parts: a moderated neutron counter, a detection system sensitive to the implantation and decay of radioactive ions, and gamma-ray detectors. We describe here the setup, the commissioning experiment and some selected results demonstrating its performance for the measurement of half-lives and beta-delayed neutron emission probabilities. The methodology followed in the analysis of the data is described in detail. Particular emphasis is placed on the correction of the accidental neutron background.
△ Less
Submitted 2 August, 2018;
originally announced August 2018.