-
Searching for the Casimir Energy
Authors:
Diego Pérez-Morelo,
Alexander Stange,
Richard W. Lally,
Lawrence K. Barrett,
Matthias Imboden,
David K. Campbell,
Vladimir A. Aksyuk,
David J. Bishop
Abstract:
In this article, we present a nano-electromechanical system (NEMS) designed to detect changes in the Casimir Energy. The Casimir effect is a result of the appearance of quantum fluctuations in the electromagnetic vacuum. Previous experiments have used nano- or micro- scale parallel plate capacitors to detect the Casimir force by measuring the small attractive force these fluctuations exert between…
▽ More
In this article, we present a nano-electromechanical system (NEMS) designed to detect changes in the Casimir Energy. The Casimir effect is a result of the appearance of quantum fluctuations in the electromagnetic vacuum. Previous experiments have used nano- or micro- scale parallel plate capacitors to detect the Casimir force by measuring the small attractive force these fluctuations exert between the two surfaces. In this new set of experiments, we aim to directly detect shifts in the Casimir $\textit{energy}$ in the vacuum due to the presence of metallic parallel plates, one of which is a superconductor. A change in the Casimir energy of this configuration is predicted to shift the superconducting transition temperature (T$_\textrm{c}$) because of an interaction between it and the superconducting condensation energy. The experiment we discuss consists of taking a superconducting film, carefully measuring its transition temperature, bringing a conducting plate close to the film, creating a Casimir cavity, and then measuring the transition temperature again. The expected shifts will be small, comparable to the normal shifts one sees in cycling superconducting films to cryogenic temperatures and so using a NEMS resonator and doing this in situ is the only practical way to obtain accurate, reproducible data. Using a thin Pb film and opposing Au surface, we observe no shift in T$_\textrm{c}$ greater than 12 $μ$K down to a minimum spacing of approximately 70 nm.
△ Less
Submitted 28 April, 2020;
originally announced April 2020.
-
100pTcm Sensitive MEMS Resonant Magnetometer from a Commercial Accelerometer
Authors:
Josh Javor,
Alexander Stange,
Corey Pollock,
Nicholas Fuhr,
David J. Bishop
Abstract:
Magnetic sensing is present in our everyday interactions with consumer electronics, and also demonstrates potential for measurement of extremely weak biomagnetic fields, such as those of the heart and brain. In this work, we leverage the many benefits of the micro-electromechanical systems (MEMS) devices to fabricate a small, low power, inexpensive sensor whose resolution is in the range of weak b…
▽ More
Magnetic sensing is present in our everyday interactions with consumer electronics, and also demonstrates potential for measurement of extremely weak biomagnetic fields, such as those of the heart and brain. In this work, we leverage the many benefits of the micro-electromechanical systems (MEMS) devices to fabricate a small, low power, inexpensive sensor whose resolution is in the range of weak biomagnetic fields. The sensor works at room temperature, and is suitable for consumer electronics integration. At present, such biomagnetic fields can only be measured by expensive mechanisms such as optical pum** and superconducting quantum interference devices (SQUIDs). Thus, our sensor suggests the opening of a large phase space for medical and consumer applications. The prototype fabrication is achieved by assembling micro-objects, including a permanent micromagnet, onto a post-release commercial MEMS accelerometer. With this system, we demonstrate a room temperature MEMS magnetometer, whose design is only sensitive to gradient magnetic fields and is generally insensitive to the Earth's uniform field. In air, the sensor's response is linear with a resolution of 1.1 nT cm-1 and spans over 3 decades of dynamic range to 4.6 μT cm-1. In 1 mTorr vacuum with 20 dB magnetic shielding, the sensor achieved 100 pT cm-1 resolution at resonance. The theoretical floor of this design is 110 fT cm-1 Hz-1/2 with a resolution of 13 fT cm-1, thus these devices hold promise for both magnetocardiography (MCG) and magnetoencephalography (MEG) applications.
△ Less
Submitted 22 November, 2019;
originally announced November 2019.
-
Building a Casimir Metrology Platform with a Commercial MEMS Accelerometer
Authors:
Alexander Stange,
Matthias Imboden,
Josh Javor,
Lawrence K. Barrett,
David J. Bishop
Abstract:
The Casimir Effect is a physical manifestation of quantum fluctuations of the electromagnetic vacuum. When two metal plates are placed closely together, typically much less than a micron, the long wavelength modes between them are frozen out, giving rise to a net attractive force between the plates, scaling as d^-4 (or d^-3 for a spherical-planar geometry) even when they are not electrically charg…
▽ More
The Casimir Effect is a physical manifestation of quantum fluctuations of the electromagnetic vacuum. When two metal plates are placed closely together, typically much less than a micron, the long wavelength modes between them are frozen out, giving rise to a net attractive force between the plates, scaling as d^-4 (or d^-3 for a spherical-planar geometry) even when they are not electrically charged. In this paper we observe the Casimir Effect in ambient conditions using a modified capacitive MEMS accelerometer. Using a feedback assisted pick-and-place assembly process we are able to attach various micro-structures onto the post-release MEMS, converting it from an inertial force sensor to a direct force measurement platform with pN resolution. With this system we are able to directly measure the Casimir force between a silver-coated microsphere and gold-coated silicon plate. This device is a step towards leveraging the Casimir Effect for cheap, sensitive, room temperature quantum metrology.
△ Less
Submitted 22 October, 2018;
originally announced October 2018.