-
High efficiency glass-based VUV metasurfaces
Authors:
Augusto Martins,
Taylor Contreras,
Chris Stanford,
Mirald Tuzi,
Justo M. Albo,
Carlos O. Escobar,
Adam Para,
Alexander Kish,
Joon-Suh Park,
Thomas F. Krauss,
Roxanne Guenette
Abstract:
Most advances in metaoptics have been made at visible wavelengths and above; in contrast, the vacuum ultraviolet (VUV) has barely been explored despite numerous scientific and technological opportunities. Creating metaoptic elements at this short wavelength is challenging due to the scarcity of VUV transparent materials and the small sizes of the required nanostructures. Here, we present the first…
▽ More
Most advances in metaoptics have been made at visible wavelengths and above; in contrast, the vacuum ultraviolet (VUV) has barely been explored despite numerous scientific and technological opportunities. Creating metaoptic elements at this short wavelength is challenging due to the scarcity of VUV transparent materials and the small sizes of the required nanostructures. Here, we present the first transmissive VUV (175 nm) metalens. By using UV-grade silica and trading-off the Nyquist requirement for subwavelength structures against feasibility of the fabrication process, we achieve a step-change in diffraction efficiencies for wavelengths shorter than 300 nm. Our large numerical aperture (NA = 0.5) metalens shows an average diffraction efficiency of (53.3 +- 1.4)%. This demonstration opens up new avenues for compact flat optic systems operating in the VUV range.
△ Less
Submitted 20 January, 2024;
originally announced January 2024.
-
Simple strategy for simulation of large area of axially symmetric metasurfaces
Authors:
Augusto Martins,
Achiles F. da Mota,
Chris Stanford,
Taylor Contreras,
Justo Martin-Albo,
Alexander Kish,
Carlos Escobar,
Adam Para,
Roxanne Guenette
Abstract:
Metalenses are composed of nanostructures for focusing light and have been widely explored in many exciting applications. However, their expanding dimensions pose simulation challenges. We propose a method to simulate metalenses in a timely manner using vectorial wave and ray tracing models. We sample the metalens' radial phase gradient and locally approximate it by a linear phase response. Each s…
▽ More
Metalenses are composed of nanostructures for focusing light and have been widely explored in many exciting applications. However, their expanding dimensions pose simulation challenges. We propose a method to simulate metalenses in a timely manner using vectorial wave and ray tracing models. We sample the metalens' radial phase gradient and locally approximate it by a linear phase response. Each sampling point is modeled as a binary blazed grating, employing the chosen nanostructure, to build a transfer function set. The metalens transmission or reflection is then obtained by applying the corresponding transfer function to the incoming field on the regions surrounding each sampling point. Fourier optics is used to calculate the scattered fields under arbitrary illumination for the vectorial wave method and a Monte Carlo algorithm is used in the ray tracing formalism. We validated our method against finite difference time domain simulations at 632 nm and we were able to simulate metalenses larger than 3000lambda0 in diameter on a personal computer.
△ Less
Submitted 29 October, 2023;
originally announced October 2023.
-
A Method To Characterize Metalenses For Light Collection Applications
Authors:
T. Contreras,
A. Martins,
C. Stanford,
C. O. Escobar,
R. Guenette,
M. stancari,
J. Martin-Albo,
B. Lawrence-Sanderson,
A. Para,
A. Kish,
F. Kellerer
Abstract:
Metalenses and metasurfaces are promising emerging technologies that could improve light collection in light collection detectors, concentrating light on small area photodetectors such as silicon photomultipliers. Here we present a detailed method to characterize metalenses to assess their efficiency at concentrating monochromatic light coming from a wide range of incidence angles, not taking into…
▽ More
Metalenses and metasurfaces are promising emerging technologies that could improve light collection in light collection detectors, concentrating light on small area photodetectors such as silicon photomultipliers. Here we present a detailed method to characterize metalenses to assess their efficiency at concentrating monochromatic light coming from a wide range of incidence angles, not taking into account their imaging quality.
△ Less
Submitted 23 August, 2023; v1 submitted 10 August, 2023;
originally announced August 2023.
-
Demonstration of neutrinoless double beta decay searches in gaseous xenon with NEXT
Authors:
NEXT Collaboration,
P. Novella,
M. Sorel,
A. Usón,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
F. Auria-Luna,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
M. del Barrio-Torregrosa,
A. Bayo,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
S. Bounasser,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián
, et al. (90 additional authors not shown)
Abstract:
The NEXT experiment aims at the sensitive search of the neutrinoless double beta decay in $^{136}$Xe, using high-pressure gas electroluminescent time projection chambers. The NEXT-White detector is the first radiopure demonstrator of this technology, operated in the Laboratorio Subterráneo de Canfranc. Achieving an energy resolution of 1% FWHM at 2.6 MeV and further background rejection by means o…
▽ More
The NEXT experiment aims at the sensitive search of the neutrinoless double beta decay in $^{136}$Xe, using high-pressure gas electroluminescent time projection chambers. The NEXT-White detector is the first radiopure demonstrator of this technology, operated in the Laboratorio Subterráneo de Canfranc. Achieving an energy resolution of 1% FWHM at 2.6 MeV and further background rejection by means of the topology of the reconstructed tracks, NEXT-White has been exploited beyond its original goals in order to perform a neutrinoless double beta decay search. The analysis considers the combination of 271.6 days of $^{136}$Xe-enriched data and 208.9 days of $^{136}$Xe-depleted data. A detailed background modeling and measurement has been developed, ensuring the time stability of the radiogenic and cosmogenic contributions across both data samples. Limits to the neutrinoless mode are obtained in two alternative analyses: a background-model-dependent approach and a novel direct background-subtraction technique, offering results with small dependence on the background model assumptions. With a fiducial mass of only 3.50$\pm$0.01 kg of $^{136}$Xe-enriched xenon, 90% C.L. lower limits to the neutrinoless double beta decay are found in the T$_{1/2}^{0ν}>5.5\times10^{23}-1.3\times10^{24}$ yr range, depending on the method. The presented techniques stand as a proof-of-concept for the searches to be implemented with larger NEXT detectors.
△ Less
Submitted 22 September, 2023; v1 submitted 16 May, 2023;
originally announced May 2023.
-
NEXT-CRAB-0: A High Pressure Gaseous Xenon Time Projection Chamber with a Direct VUV Camera Based Readout
Authors:
NEXT Collaboration,
N. K. Byrnes,
I. Parmaksiz,
C. Adams,
J. Asaadi,
J Baeza-Rubio,
K. Bailey,
E. Church,
D. González-Díaz,
A. Higley,
B. J. P. Jones,
K. Mistry,
I. A. Moya,
D. R. Nygren,
P. Oyedele,
L. Rogers,
K. Stogsdill,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
S. Ayet,
C. D. R. Azevedo
, et al. (94 additional authors not shown)
Abstract:
The search for neutrinoless double beta decay ($0νββ$) remains one of the most compelling experimental avenues for the discovery in the neutrino sector. Electroluminescent gas-phase time projection chambers are well suited to $0νββ$ searches due to their intrinsically precise energy resolution and topological event identification capabilities. Scalability to ton- and multi-ton masses requires read…
▽ More
The search for neutrinoless double beta decay ($0νββ$) remains one of the most compelling experimental avenues for the discovery in the neutrino sector. Electroluminescent gas-phase time projection chambers are well suited to $0νββ$ searches due to their intrinsically precise energy resolution and topological event identification capabilities. Scalability to ton- and multi-ton masses requires readout of large-area electroluminescent regions with fine spatial resolution, low radiogenic backgrounds, and a scalable data acquisition system. This paper presents a detector prototype that records event topology in an electroluminescent xenon gas TPC via VUV image-intensified cameras. This enables an extendable readout of large tracking planes with commercial devices that reside almost entirely outside of the active medium.Following further development in intermediate scale demonstrators, this technique may represent a novel and enlargeable method for topological event imaging in $0νββ$.
△ Less
Submitted 3 August, 2023; v1 submitted 12 April, 2023;
originally announced April 2023.
-
A Compact Dication Source for Ba$^{2+}$ Tagging and Heavy Metal Ion Sensor Development
Authors:
K. E. Navarro,
B. J. P. Jones,
J. Baeza-Rubio,
M. Boyd,
A. A. Denisenko,
F. W. Foss,
S. Giri,
R. Miller,
D. R. Nygren,
M. R. Tiscareno,
F. J. Samaniego,
K. Stogsdill,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges
, et al. (85 additional authors not shown)
Abstract:
We present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the…
▽ More
We present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the retention time in the ionization region. Barium, lead, and cobalt samples have been used to test the system, with ion currents identified and quantified using a quadrupole mass analyzer. Realization of a clean $\mathrm{Ba^{2+}}$ ion beam within a bench-top system represents an important technical advance toward the development and characterization of barium tagging systems for neutrinoless double beta decay searches in xenon gas. This system also provides a testbed for investigation of novel ion sensing methodologies for environmental assay applications, with dication beams of Pb$^{2+}$ and Cd$^{2+}$ also demonstrated for this purpose.
△ Less
Submitted 2 March, 2023;
originally announced March 2023.
-
Reflectance and fluorescence characteristics of PTFE coated with TPB at visible, UV, and VUV as a function of thickness
Authors:
J. Haefner,
A. Fahs,
J. Ho,
C. Stanford,
R. Guenette,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
F. Auria-Luna,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
S. Bounasser,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church
, et al. (78 additional authors not shown)
Abstract:
Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. In noble element systems, it is often coated with tetraphenyl butadiene (TPB) to allow detection of vacuum ultraviolet scintillation light. In this work this dependence is investigated for PTFE coated with TPB in air for light of wavelengths of 200~nm, 260~nm,…
▽ More
Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. In noble element systems, it is often coated with tetraphenyl butadiene (TPB) to allow detection of vacuum ultraviolet scintillation light. In this work this dependence is investigated for PTFE coated with TPB in air for light of wavelengths of 200~nm, 260~nm, and 450~nm. The results show that TPB-coated PTFE has a reflectance of approximately 92\% for thicknesses ranging from 5~mm to 10~mm at 450~nm, with negligible variation as a function of thickness within this range. A cross-check of these results using an argon chamber supports the conclusion that the change in thickness from 5~mm to 10~mm does not affect significantly the light response at 128~nm. Our results indicate that pieces of TPB-coated PTFE thinner than the typical 10~mm can be used in particle physics detectors without compromising the light signal.
△ Less
Submitted 10 January, 2023; v1 submitted 9 November, 2022;
originally announced November 2022.
-
Snowmass Instrumentation Frontier IF08 Topical Group Report: Noble Element Detectors
Authors:
Carl Eric Dahl,
Roxanne Guenette,
Jennifer L. Raaf,
D. Akerib,
J. Asaadi,
D. Caratelli,
E. Church,
M. Del Tutto,
A. Fava,
R. Gaitskell,
G. K. Giovanetti,
G. Giroux,
D. Gonzalez Diaz,
E. Gramellini,
S. Haselschwardt,
C. Jackson,
B. J. P. Jones,
A. Kopec,
S. Kravitz,
H. Lippincott,
J. Liu,
C. J. Martoff,
A. Mastbaum,
C. Montanari,
M. Mooney
, et al. (17 additional authors not shown)
Abstract:
Particle detectors making use of noble elements in gaseous, liquid, or solid phases are prevalent in neutrino and dark matter experiments and are also used to a lesser extent in collider-based particle physics experiments. These experiments take advantage of both the very large, ultra-pure target volumes achievable and the multiple observable signal pathways possible in noble-element based particl…
▽ More
Particle detectors making use of noble elements in gaseous, liquid, or solid phases are prevalent in neutrino and dark matter experiments and are also used to a lesser extent in collider-based particle physics experiments. These experiments take advantage of both the very large, ultra-pure target volumes achievable and the multiple observable signal pathways possible in noble-element based particle detectors. As these experiments seek to increase their sensitivity, novel and improved technologies will be needed to enhance the precision of their measurements and to broaden the reach of their physics programs. The areas of R&D in noble element instrumentation that have been identified by the HEP community in the Snowmass process are highlighted by five key messages: IF08-1) Enhance and combine existing modalities (scintillation and electron drift) to increase signal-to-noise and reconstruction fidelity; IF08-2) Develop new modalities for signal detection in noble elements, including methods based on ion drift, metastable fluids, solid-phase detectors and dissolved targets. Collaborative and blue-sky R&D should also be supported to enable advances in this area; IF08-3) Improve the understanding of detector microphysics and calibrate detector response in new signal regimes; IF08-4) Address challenges in scaling technologies, including material purification, background mitigation, large-area readout, and magnetization; and IF08-5) Train the next generation of researchers, using fast-turnaround instrumentation projects to provide the design-through-result training no longer possible in very-large-scale experiments. This topical group report identifies and documents recent developments and future needs for noble element detector technologies. In addition, we highlight the opportunity that this area of research provides for continued training of the next generation of scientists.
△ Less
Submitted 15 September, 2022; v1 submitted 23 August, 2022;
originally announced August 2022.
-
Reconstruction of interactions in the ProtoDUNE-SP detector with Pandora
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
B. Ali-Mohammadzadeh,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo
, et al. (1203 additional authors not shown)
Abstract:
The Pandora Software Development Kit and algorithm libraries provide pattern-recognition logic essential to the reconstruction of particle interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at ProtoDUNE-SP, a prototype for the Deep Underground Neutrino Experiment far detector. ProtoDUNE-SP, located at CERN, is exposed to a char…
▽ More
The Pandora Software Development Kit and algorithm libraries provide pattern-recognition logic essential to the reconstruction of particle interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at ProtoDUNE-SP, a prototype for the Deep Underground Neutrino Experiment far detector. ProtoDUNE-SP, located at CERN, is exposed to a charged-particle test beam. This paper gives an overview of the Pandora reconstruction algorithms and how they have been tailored for use at ProtoDUNE-SP. In complex events with numerous cosmic-ray and beam background particles, the simulated reconstruction and identification efficiency for triggered test-beam particles is above 80% for the majority of particle type and beam momentum combinations. Specifically, simulated 1 GeV/$c$ charged pions and protons are correctly reconstructed and identified with efficiencies of 86.1$\pm0.6$% and 84.1$\pm0.6$%, respectively. The efficiencies measured for test-beam data are shown to be within 5% of those predicted by the simulation.
△ Less
Submitted 17 July, 2023; v1 submitted 29 June, 2022;
originally announced June 2022.
-
Digital Wire Analyzer of Mechanical Tension, Electrical Continuity, and Isolation
Authors:
Sebastien Prince,
Pratyush Anand,
James Battat,
Russell Farnsworth,
Nathan Felt,
Roxanne Guenette,
Shion Kubota,
Austin Li,
Em Murdock,
John Oliver,
Chris Stanford,
Jackson Weaver
Abstract:
A digital instrument that allows the measurement of the mechanical tension of an array of wires of known length and density, and the testing of their electrical continuity and isolation, has been developed. The instrument measures wire tension by measuring the fundamental frequency of the wire. Its working principle is to apply direct high voltages on neighboring wires of a wire under test and swe…
▽ More
A digital instrument that allows the measurement of the mechanical tension of an array of wires of known length and density, and the testing of their electrical continuity and isolation, has been developed. The instrument measures wire tension by measuring the fundamental frequency of the wire. Its working principle is to apply direct high voltages on neighboring wires of a wire under test and swee** the frequency of an alternating high voltage that is also applied on those neighbors. A resonance is observed in the readout signal of the middle wire when the frequency of the alternating high voltage coincides with its fundamental frequency. The instrument automates the process over 128 wires, with eight read out simultaneously. An accuracy of 1% in the measurement of tension is achieved by this digital wire analyzer (DWA).
△ Less
Submitted 16 November, 2022; v1 submitted 31 May, 2022;
originally announced June 2022.
-
Investigating the sources of low-energy events in a SuperCDMS-HVeV detector
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley
, et al. (104 additional authors not shown)
Abstract:
Recent experiments searching for sub-GeV/$c^2$ dark matter have observed event excesses close to their respective energy thresholds. Although specific to the individual technologies, the measured excess event rates have been consistently reported at or below event energies of a few-hundred eV, or with charges of a few electron-hole pairs. In the present work, we operated a 1-gram silicon SuperCDMS…
▽ More
Recent experiments searching for sub-GeV/$c^2$ dark matter have observed event excesses close to their respective energy thresholds. Although specific to the individual technologies, the measured excess event rates have been consistently reported at or below event energies of a few-hundred eV, or with charges of a few electron-hole pairs. In the present work, we operated a 1-gram silicon SuperCDMS-HVeV detector at three voltages across the crystal (0 V, 60 V and 100 V). The 0 V data show an excess of events in the tens of eV region. Despite this event excess, we demonstrate the ability to set a competitive exclusion limit on the spin-independent dark matter--nucleon elastic scattering cross section for dark matter masses of $\mathcal{O}(100)$ MeV/$c^2$, enabled by operation of the detector at 0 V potential and achievement of a very low $\mathcal{O}(10)$ eV threshold for nuclear recoils. Comparing the data acquired at 0 V, 60 V and 100 V potentials across the crystal, we investigated possible sources of the unexpected events observed at low energy. The data indicate that the dominant contribution to the excess is consistent with a hypothesized luminescence from the printed circuit boards used in the detector holder.
△ Less
Submitted 11 October, 2022; v1 submitted 17 April, 2022;
originally announced April 2022.
-
Separation of track- and shower-like energy deposits in ProtoDUNE-SP using a convolutional neural network
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1204 additional authors not shown)
Abstract:
Liquid argon time projection chamber detector technology provides high spatial and calorimetric resolutions on the charged particles traversing liquid argon. As a result, the technology has been used in a number of recent neutrino experiments, and is the technology of choice for the Deep Underground Neutrino Experiment (DUNE). In order to perform high precision measurements of neutrinos in the det…
▽ More
Liquid argon time projection chamber detector technology provides high spatial and calorimetric resolutions on the charged particles traversing liquid argon. As a result, the technology has been used in a number of recent neutrino experiments, and is the technology of choice for the Deep Underground Neutrino Experiment (DUNE). In order to perform high precision measurements of neutrinos in the detector, final state particles need to be effectively identified, and their energy accurately reconstructed. This article proposes an algorithm based on a convolutional neural network to perform the classification of energy deposits and reconstructed particles as track-like or arising from electromagnetic cascades. Results from testing the algorithm on data from ProtoDUNE-SP, a prototype of the DUNE far detector, are presented. The network identifies track- and shower-like particles, as well as Michel electrons, with high efficiency. The performance of the algorithm is consistent between data and simulation.
△ Less
Submitted 30 June, 2022; v1 submitted 31 March, 2022;
originally announced March 2022.
-
Scintillation light detection in the 6-m drift-length ProtoDUNE Dual Phase liquid argon TPC
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
B. Ali-Mohammadzadeh,
T. Alion,
K. Allison,
S. Alonso Monsalve,
M. AlRashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1202 additional authors not shown)
Abstract:
DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE Dual Phase (DP) is a 6x6x6m3 liquid argon time-projection-chamber (LArTPC) that recorded cosmic-muon data at the CERN Neutrino Platform in 2019-2020 as a prototype of the DUNE Far Detector. Charged particles propagating through the LArTPC produce ionization and…
▽ More
DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. ProtoDUNE Dual Phase (DP) is a 6x6x6m3 liquid argon time-projection-chamber (LArTPC) that recorded cosmic-muon data at the CERN Neutrino Platform in 2019-2020 as a prototype of the DUNE Far Detector. Charged particles propagating through the LArTPC produce ionization and scintillation light. The scintillation light signal in these detectors can provide the trigger for non-beam events. In addition, it adds precise timing capabilities and improves the calorimetry measurements. In ProtoDUNE-DP, scintillation and electroluminescence light produced by cosmic muons in the LArTPC is collected by photomultiplier tubes placed up to 7 m away from the ionizing track. In this paper, the ProtoDUNE-DP photon detection system performance is evaluated with a particular focus on the different wavelength shifters, such as PEN and TPB, and the use of Xe-doped LAr, considering its future use in giant LArTPCs. The scintillation light production and propagation processes are analyzed and a comparison of simulation to data is performed, improving understanding of the liquid argon properties
△ Less
Submitted 3 June, 2022; v1 submitted 30 March, 2022;
originally announced March 2022.
-
A Strategy for Low-Mass Dark Matter Searches with Cryogenic Detectors in the SuperCDMS SNOLAB Facility
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeno,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley
, et al. (103 additional authors not shown)
Abstract:
The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-ba…
▽ More
The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-based scenarios are forecasted to probe many square decades of unexplored dark matter parameter space below 5 GeV/c$^2$, covering over 6 decades in mass: 1-100 eV/c$^2$ for dark photons and axion-like particles, 1-100 MeV/c$^2$ for dark-photon-coupled light dark matter, and 0.05-5 GeV/c$^2$ for nucleon-coupled dark matter. They will reach the neutrino fog in the 0.5-5 GeV/c$^2$ mass range and test a variety of benchmark models and sharp targets. The novel directions involve greater departures from current SuperCDMS technology but promise even greater reach in the long run, and their development must begin now for them to be available in a timely fashion.
The experienced-based upgrade scenarios rely mainly on dramatic improvements in detector performance based on demonstrated scaling laws and reasonable extrapolations of current performance. Importantly, these improvements in detector performance obviate significant reductions in background levels beyond current expectations for the SuperCDMS SNOLAB experiment. Given that the dominant limiting backgrounds for SuperCDMS SNOLAB are cosmogenically created radioisotopes in the detectors, likely amenable only to isotopic purification and an underground detector life-cycle from before crystal growth to detector testing, the potential cost and time savings are enormous and the necessary improvements much easier to prototype.
△ Less
Submitted 1 April, 2023; v1 submitted 16 March, 2022;
originally announced March 2022.
-
Ionization yield measurement in a germanium CDMSlite detector using photo-neutron sources
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen
, et al. (104 additional authors not shown)
Abstract:
Two photo-neutron sources, $^{88}$Y$^{9}$Be and $^{124}$Sb$^{9}$Be, have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. This work evaluates the yield for nuclear recoil energies between 1 keV and 7 keV at a temperature of $\sim$ 50 mK. We use a Geant4 simulation to model the neutron spectrum assuming a charge yie…
▽ More
Two photo-neutron sources, $^{88}$Y$^{9}$Be and $^{124}$Sb$^{9}$Be, have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. This work evaluates the yield for nuclear recoil energies between 1 keV and 7 keV at a temperature of $\sim$ 50 mK. We use a Geant4 simulation to model the neutron spectrum assuming a charge yield model that is a generalization of the standard Lindhard model and consists of two energy dependent parameters. We perform a likelihood analysis using the simulated neutron spectrum, modeled background, and experimental data to obtain the best fit values of the yield model. The ionization yield between recoil energies of 1 keV and 7 keV is shown to be significantly lower than predicted by the standard Lindhard model for germanium. There is a general lack of agreement among different experiments using a variety of techniques studying the low-energy range of the nuclear recoil yield, which is most critical for interpretation of direct dark matter searches. This suggests complexity in the physical process that many direct detection experiments use to model their primary signal detection mechanism and highlights the need for further studies to clarify underlying systematic effects that have not been well understood up to this point.
△ Less
Submitted 27 June, 2022; v1 submitted 14 February, 2022;
originally announced February 2022.
-
Ba$^{2+}$ ion trap** by organic submonolayer: towards an ultra-low background neutrinoless double beta decay detector
Authors:
P. Herrero-Gómez,
J. P. Calupitan,
M. Ilyn,
A. Berdonces-Layunta,
T. Wang,
D. G. de Oteyza,
M. Corso,
R. González-Moreno,
I. Rivilla,
B. Aparicio,
A. I. Aranburu,
Z. Freixa,
F. Monrabal,
F. P. Cossío,
J. J. Gómez-Cadenas,
C. Rogero,
C. Adams,
H. Almazán,
V. Alvarez,
L. Arazi,
I. J. Arnquist,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester
, et al. (90 additional authors not shown)
Abstract:
If neutrinos are their own antiparticles, the otherwise-forbidden nuclear reaction known as neutrinoless double beta decay ($ββ0ν$) can occur, with a characteristic lifetime which is expected to be very long, making the suppression of backgrounds a daunting task. It has been shown that detecting (``tagging'') the Ba$^{+2}$ dication produced in the double beta decay…
▽ More
If neutrinos are their own antiparticles, the otherwise-forbidden nuclear reaction known as neutrinoless double beta decay ($ββ0ν$) can occur, with a characteristic lifetime which is expected to be very long, making the suppression of backgrounds a daunting task. It has been shown that detecting (``tagging'') the Ba$^{+2}$ dication produced in the double beta decay ${}^{136}\mathrm{Xe} \rightarrow {}^{136}$Ba$^{+2}+ 2 e + (2 ν)$ in a high pressure gas experiment, could lead to a virtually background free experiment. To identify these \Bapp, chemical sensors are being explored as a key tool by the NEXT collaboration . Although used in many fields, the application of such chemosensors to the field of particle physics is totally novel and requires experimental demonstration of their suitability in the ultra-dry environment of a xenon gas chamber. Here we use a combination of complementary surface science techniques to unambiguously show that Ba$^{+2}$ ions can be trapped (chelated) in vacuum by an organic molecule, the so-called fluorescent bicolour indicator (FBI) (one of the chemosensors developed by NEXT), immobilized on a surface. We unravel the ion capture mechanism once the molecules are immobilised on Au(111) surface and explain the origin of the emission fluorescence shift associated to the trap** of different ions. Moreover, we prove that chelation also takes place on a technologically relevant substrate, as such, demonstrating the feasibility of using FBI indicators as building blocks of a Ba$^{+2}$ detector.
△ Less
Submitted 22 January, 2022;
originally announced January 2022.
-
Measurement of the ${}^{136}$Xe two-neutrino double beta decay half-life via direct background subtraction in NEXT
Authors:
NEXT Collaboration,
P. Novella,
M. Sorel,
A. Usón,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
S. Bounasser,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church,
C. A. N. Conde,
T. Contreras
, et al. (85 additional authors not shown)
Abstract:
We report a measurement of the half-life of the ${}^{136}$Xe two-neutrino double beta decay performed with a novel direct background subtraction technique. The analysis relies on the data collected with the NEXT-White detector operated with ${}^{136}$Xe-enriched and ${}^{136}$Xe-depleted xenon, as well as on the topology of double-electron tracks. With a fiducial mass of only 3.5 kg of Xe, a half-…
▽ More
We report a measurement of the half-life of the ${}^{136}$Xe two-neutrino double beta decay performed with a novel direct background subtraction technique. The analysis relies on the data collected with the NEXT-White detector operated with ${}^{136}$Xe-enriched and ${}^{136}$Xe-depleted xenon, as well as on the topology of double-electron tracks. With a fiducial mass of only 3.5 kg of Xe, a half-life of $2.34^{+0.80}_{-0.46}\textrm{(stat)}^{+0.30}_{-0.17}\textrm{(sys)}\times10^{21}~\textrm{yr}$ is derived from the background-subtracted energy spectrum. The presented technique demonstrates the feasibility of unique background-model-independent neutrinoless double beta decay searches.
△ Less
Submitted 11 May, 2022; v1 submitted 22 November, 2021;
originally announced November 2021.
-
Kiloton-scale xenon detectors for neutrinoless double beta decay and other new physics searches
Authors:
A. Avasthi,
T. W. Bowyer,
C. Bray,
T. Brunner,
N. Catarineu,
E. Church,
R. Guenette,
S. J. Haselschwardt,
J. C. Hayes,
M. Heffner,
S. A. Hertel,
P. H. Humble,
A. Jamil,
S. Kim,
R. F. Lang,
K. G. Leach,
B. G. Lenardo,
W. H. Lippincott,
A. Marino,
D. N. McKinsey,
E. H. Miller,
D. C. Moore,
B. Mong,
B. Monreal,
M. E. Monzani
, et al. (9 additional authors not shown)
Abstract:
Large detectors employing xenon are a leading technology in existing and planned searches for new physics, including searches for neutrinoless double beta decay ($0νββ$) and dark matter. While upcoming detectors will employ target masses of a ton or more, further extending gas or liquid phase Xe detectors to the kton scale would enable extremely sensitive next-generation searches for rare phenomen…
▽ More
Large detectors employing xenon are a leading technology in existing and planned searches for new physics, including searches for neutrinoless double beta decay ($0νββ$) and dark matter. While upcoming detectors will employ target masses of a ton or more, further extending gas or liquid phase Xe detectors to the kton scale would enable extremely sensitive next-generation searches for rare phenomena. The key challenge to extending this technology to detectors well beyond the ton scale is the acquisition of the Xe itself. We describe the motivation for extending Xe time projection chambers (TPCs) to the kton scale and possible avenues for Xe acquisition that avoid existing supply chains. If acquisition of Xe in the required quantities is successful, kton-scale detectors of this type could enable a new generation of experiments, including searches for $0νββ$ at half-life sensitivities as long as $10^{30}$ yr.
△ Less
Submitted 21 December, 2021; v1 submitted 4 October, 2021;
originally announced October 2021.
-
The Dynamics of Ions on Phased Radio-frequency Carpets in High Pressure Gases and Application for Barium Tagging in Xenon Gas Time Projection Chambers
Authors:
NEXT Collaboration,
B. J. P. Jones,
A. Raymond,
K. Woodruff,
N. Byrnes,
A. A. Denisenko,
F. W. Foss,
K. Navarro,
D. R. Nygren,
T. T. Vuong,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
S. Bounasser,
S. Cárcel
, et al. (85 additional authors not shown)
Abstract:
Radio-frequency (RF) carpets with ultra-fine pitches are examined for ion transport in gases at atmospheric pressures and above. We develop new analytic and computational methods for modeling RF ion transport at densities where dynamics are strongly influenced by buffer gas collisions. An analytic description of levitating and swee** forces from phased arrays is obtained, then thermodynamic and…
▽ More
Radio-frequency (RF) carpets with ultra-fine pitches are examined for ion transport in gases at atmospheric pressures and above. We develop new analytic and computational methods for modeling RF ion transport at densities where dynamics are strongly influenced by buffer gas collisions. An analytic description of levitating and swee** forces from phased arrays is obtained, then thermodynamic and kinetic principles are used to calculate ion loss rates in the presence of collisions. This methodology is validated against detailed microscopic SIMION simulations. We then explore a parameter space of special interest for neutrinoless double beta decay experiments: transport of barium ions in xenon at pressures from 1 to 10 bar. Our computations account for molecular ion formation and pressure dependent mobility as well as finite temperature effects. We discuss the challenges associated with achieving suitable operating conditions, which lie beyond the capabilities of existing devices, using presently available or near-future manufacturing techniques.
△ Less
Submitted 29 September, 2021; v1 submitted 8 September, 2021;
originally announced September 2021.
-
Boosting background suppression in the NEXT experiment through Richardson-Lucy deconvolution
Authors:
A. Simón,
Y. Ifergan,
A. B. Redwine,
R. Weiss-Babai,
L. Arazi,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
I. J. Arnquist,
C. D. R Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church,
C. A. N. Conde,
T. Contreras,
F. P. Cossío,
A. A. Denisenko
, et al. (78 additional authors not shown)
Abstract:
Next-generation neutrinoless double beta decay experiments aim for half-life sensitivities of ~$10^{27}$ yr, requiring suppressing backgrounds to <1 count/tonne/yr. For this, any extra background rejection handle, beyond excellent energy resolution and the use of extremely radiopure materials, is of utmost importance. The NEXT experiment exploits differences in the spatial ionization patterns of d…
▽ More
Next-generation neutrinoless double beta decay experiments aim for half-life sensitivities of ~$10^{27}$ yr, requiring suppressing backgrounds to <1 count/tonne/yr. For this, any extra background rejection handle, beyond excellent energy resolution and the use of extremely radiopure materials, is of utmost importance. The NEXT experiment exploits differences in the spatial ionization patterns of double beta decay and single-electron events to discriminate signal from background. While the former display two Bragg peak dense ionization regions at the opposite ends of the track, the latter typically have only one such feature. Thus, comparing the energies at the track extremes provides an additional rejection tool. The unique combination of the topology-based background discrimination and excellent energy resolution (1% FWHM at the Q-value of the decay) is the distinguishing feature of NEXT. Previous studies demonstrated a topological background rejection factor of ~5 when reconstructing electron-positron pairs in the $^{208}$Tl 1.6 MeV double escape peak (with Compton events as background), recorded in the NEXT-White demonstrator at the Laboratorio Subterráneo de Canfranc, with 72% signal efficiency. This was recently improved through the use of a deep convolutional neural network to yield a background rejection factor of ~10 with 65% signal efficiency. Here, we present a new reconstruction method, based on the Richardson-Lucy deconvolution algorithm, which allows reversing the blurring induced by electron diffusion and electroluminescence light production in the NEXT TPC. The new method yields highly refined 3D images of reconstructed events, and, as a result, significantly improves the topological background discrimination. When applied to real-data 1.6 MeV $e^-e^+$ pairs, it leads to a background rejection factor of 27 at 57% signal efficiency.
△ Less
Submitted 21 May, 2021; v1 submitted 23 February, 2021;
originally announced February 2021.
-
Constraints on Lightly Ionizing Particles from CDMSlite
Authors:
SuperCDMS Collaboration,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen
, et al. (93 additional authors not shown)
Abstract:
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved efficient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits calculated using the optimum interval method on the v…
▽ More
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved efficient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits calculated using the optimum interval method on the vertical intensity of cosmogenically-produced LIPs with an electric charge smaller than $e/(3\times10^5$), as well as the strongest limits for charge $\leq e/160$, with a minimum vertical intensity of $1.36\times10^{-7}$\,cm$^{-2}$s$^{-1}$sr$^{-1}$ at charge $e/160$. These results apply over a wide range of LIP masses (5\,MeV/$c^2$ to 100\,TeV/$c^2$) and cover a wide range of $βγ$ values (0.1 -- $10^6$), thus excluding non-relativistic LIPs with $βγ$ as small as 0.1 for the first time.
△ Less
Submitted 19 February, 2022; v1 submitted 18 November, 2020;
originally announced November 2020.
-
Photoelectric absorption cross section of silicon near the band gap from room temperature to sub-Kelvin temperature
Authors:
C. Stanford,
M. J. Wilson,
B. Cabrera,
M. Diamond,
N. A. Kurinsky,
R. A. Moffatt,
F. Ponce,
B. von Krosigk,
B. A. Young
Abstract:
The use of cryogenic silicon as a detector medium for dark matter searches is gaining popularity. Many of these searches are highly dependent on the value of the photoelectric absorption cross section of silicon at low temperatures, particularly near the silicon band gap energy, where the searches are most sensitive to low mass dark matter candidates. While such cross section data has been lacking…
▽ More
The use of cryogenic silicon as a detector medium for dark matter searches is gaining popularity. Many of these searches are highly dependent on the value of the photoelectric absorption cross section of silicon at low temperatures, particularly near the silicon band gap energy, where the searches are most sensitive to low mass dark matter candidates. While such cross section data has been lacking from the literature, previous dark matter search experiments have attempted to estimate this parameter by extrapolating it from higher temperature data. However, discrepancies in the high temperature data have led to order-of-magnitude differences in the extrapolations. In this paper, we resolve these discrepancies by using a novel technique to make a direct, low temperature measurement of the photoelectric absorption cross section of silicon at energies near the band gap.
△ Less
Submitted 29 October, 2020;
originally announced October 2020.
-
Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground
Authors:
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen
, et al. (99 additional authors not shown)
Abstract:
We present limits on spin-independent dark matter-nucleon interactions using a $10.6$ $\mathrm{g}$ Si athermal phonon detector with a baseline energy resolution of $σ_E=3.86 \pm 0.04$ $(\mathrm{stat.})^{+0.19}_{-0.00}$ $(\mathrm{syst.})$ $\mathrm{eV}$. This exclusion analysis sets the most stringent dark matter-nucleon scattering cross-section limits achieved by a cryogenic detector for dark matte…
▽ More
We present limits on spin-independent dark matter-nucleon interactions using a $10.6$ $\mathrm{g}$ Si athermal phonon detector with a baseline energy resolution of $σ_E=3.86 \pm 0.04$ $(\mathrm{stat.})^{+0.19}_{-0.00}$ $(\mathrm{syst.})$ $\mathrm{eV}$. This exclusion analysis sets the most stringent dark matter-nucleon scattering cross-section limits achieved by a cryogenic detector for dark matter particle masses from $93$ to $140$ $\mathrm{MeV}/c^2$, with a raw exposure of $9.9$ $\mathrm{g}\cdot\mathrm{d}$ acquired at an above-ground facility. This work illustrates the scientific potential of detectors with athermal phonon sensors with eV-scale energy resolution for future dark matter searches.
△ Less
Submitted 12 October, 2021; v1 submitted 21 July, 2020;
originally announced July 2020.
-
Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector
Authors:
SuperCDMS Collaboration,
D. W. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
R. Chen,
N. Chott,
J. Cooley
, et al. (94 additional authors not shown)
Abstract:
This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a…
▽ More
This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 gram-days of exposure acquired in an above-ground laboratory. With charge carrier trap** and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section $\barσ_{e}$ is constrained for dark matter masses from 0.5--$10^{4} $MeV$/c^{2}$; in the mass range from 1.2--50 eV$/c^{2}$ the dark photon kinetic mixing parameter $\varepsilon$ and the axioelectric coupling constant $g_{ae}$ are constrained. The minimum 90% confidence-level upper limits within the above mentioned mass ranges are $\barσ_{e}\,=\,8.7\times10^{-34}$ cm$^{2}$, $\varepsilon\,=\,3.3\times10^{-14}$, and $g_{ae}\,=\,1.0\times10^{-9}$.
△ Less
Submitted 29 January, 2021; v1 submitted 28 May, 2020;
originally announced May 2020.
-
Sensitivity of a tonne-scale NEXT detector for neutrinoless double beta decay searches
Authors:
NEXT Collaboration,
C. Adams,
V. Álvarez,
L. Arazi,
I. J. Arnquist,
C. D. R Azevedo,
K. Bailey,
F. Ballester,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
N. Byrnes,
S. Cárcel,
J. V. Carrión,
S. Cebrián,
E. Church,
C. A. N. Conde,
T. Contreras,
A. A. Denisenko,
G. Díaz,
J. Díaz,
J. Escada,
R. Esteve,
R. Felkai,
L. M. P. Fernandes,
P. Ferrario
, et al. (74 additional authors not shown)
Abstract:
The Neutrino Experiment with a Xenon TPC (NEXT) searches for the neutrinoless double-beta decay of Xe-136 using high-pressure xenon gas TPCs with electroluminescent amplification. A scaled-up version of this technology with about 1 tonne of enriched xenon could reach in less than 5 years of operation a sensitivity to the half-life of neutrinoless double-beta decay decay better than 1E27 years, imp…
▽ More
The Neutrino Experiment with a Xenon TPC (NEXT) searches for the neutrinoless double-beta decay of Xe-136 using high-pressure xenon gas TPCs with electroluminescent amplification. A scaled-up version of this technology with about 1 tonne of enriched xenon could reach in less than 5 years of operation a sensitivity to the half-life of neutrinoless double-beta decay decay better than 1E27 years, improving the current limits by at least one order of magnitude. This prediction is based on a well-understood background model dominated by radiogenic sources. The detector concept presented here represents a first step on a compelling path towards sensitivity to the parameter space defined by the inverted ordering of neutrino masses, and beyond.
△ Less
Submitted 22 February, 2021; v1 submitted 13 May, 2020;
originally announced May 2020.
-
Effective field theory interactions for liquid argon target in DarkSide-50 experiment
Authors:
The DarkSide-50 Collaboration,
:,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
G. Bonfini,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
A. Candela,
M. Caravati,
M. Cariello,
M. Carlini,
M. Carpinelli
, et al. (143 additional authors not shown)
Abstract:
We reanalize data collected with the DarkSide-50 experiment and recently used to set limits on the spin-independent interaction rate of weakly interacting massive particles (WIMPs) on argon nuclei with an effective field theory framework. The dataset corresponds to a total (16660 $\pm$ 270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We obtain upper…
▽ More
We reanalize data collected with the DarkSide-50 experiment and recently used to set limits on the spin-independent interaction rate of weakly interacting massive particles (WIMPs) on argon nuclei with an effective field theory framework. The dataset corresponds to a total (16660 $\pm$ 270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We obtain upper limits on the effective couplings of the 12 leading operators in the nonrelativistic systematic expansion. For each effective coupling we set constraints on WIMP-nucleon cross sections, setting upper limits between $2.4 \times 10^{-45} \, \mathrm{cm}^2$ and $2.3 \times 10^{-42} \, \mathrm{cm}^2$ (8.9 $\times 10^{-45} \, \mathrm{cm}^2$ and 6.0 $\times 10^{-42} \, \mathrm{cm}^2$) for WIMPs of mass of 100 $\mathrm{GeV/c^2}$ (1000 $\mathrm{GeV/c^2}$) at 90\% confidence level.
△ Less
Submitted 18 February, 2020;
originally announced February 2020.
-
Modeling of Impact Ionization and Charge Trap** in SuperCDMS HVeV Detectors
Authors:
F. Ponce,
W. Page,
P. L. Brink,
B. Cabrera,
M. Cherry,
C. Fink,
N. Kurinsky,
R. Partridge,
M. Pyle,
B. Sadoulet,
B. Serfass,
C. Stanford,
S. L. Watkins,
S. Yellin,
B. A. Young
Abstract:
A model for charge trap** and impact ionization, and an experiment to measure these parameters is presented for the SuperCDMS HVeV detector. A procedure to isolate and quantify the main sources of noise (bulk and surface charge leakage) in the measurements is also describe. This sets the stage to precisely measure the charge trap** and impact ionization probabilities in order to incorporate th…
▽ More
A model for charge trap** and impact ionization, and an experiment to measure these parameters is presented for the SuperCDMS HVeV detector. A procedure to isolate and quantify the main sources of noise (bulk and surface charge leakage) in the measurements is also describe. This sets the stage to precisely measure the charge trap** and impact ionization probabilities in order to incorporate this model into future dark matter searches.
△ Less
Submitted 24 December, 2019;
originally announced December 2019.
-
Measuring the Impact Ionization and Charge Trap** Probabilities in SuperCDMS HVeV Phonon Sensing Detectors
Authors:
F. Ponce,
W. Page,
P. L. Brink,
B. Cabrera,
M. Cherry,
C. Fink,
N. Kurinsky,
R. Partridge,
M. Pyle,
B. Sadoulet,
B. Serfass,
C. Stanford,
S. L. Watkins,
S. Yellin,
B. A. Young
Abstract:
A 0.93 gram $1{\times}1{\times}0.4$ cm$^3$ SuperCDMS silicon HVeV detector operated at 30 mK was illuminated by 1.91 eV photons using a room temperature pulsed laser coupled to the cryostat via fiber optic. The detector's response under a variety of specific operating conditions was used to study the detector leakage current, charge trap** and impact ionization in the high-purity Si substrate. T…
▽ More
A 0.93 gram $1{\times}1{\times}0.4$ cm$^3$ SuperCDMS silicon HVeV detector operated at 30 mK was illuminated by 1.91 eV photons using a room temperature pulsed laser coupled to the cryostat via fiber optic. The detector's response under a variety of specific operating conditions was used to study the detector leakage current, charge trap** and impact ionization in the high-purity Si substrate. The measured probabilities for a charge carrier in the detector to undergo charge trap** (0.713 $\pm$ 0.093%) or cause impact ionization (1.576 $\pm$ 0.110%) were found to be nearly independent of bias polarity and charge-carrier type (electron or hole) for substrate biases of $\pm$ 140 V.
△ Less
Submitted 1 December, 2019; v1 submitted 4 October, 2019;
originally announced October 2019.
-
Measurement of the ion fraction and mobility of $^{218}$Po produced in $^{222}$Rn decays in liquid argon
Authors:
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
M. Ave,
H. O. Back,
G. Batignani,
K. Biery,
V. Bocci,
G. Bonfini,
W. M. Bonivento,
B. Bottino,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
A. Candela,
M. Caravati,
M. Cariello,
M. Carlini,
M. Carpinelli,
S. Catalanotti,
V. Cataudella
, et al. (141 additional authors not shown)
Abstract:
We report measurements of the charged daughter fraction of $^{218}$Po as a result of the $^{222}$Rn alpha decay, and the mobility of $^{218}$Po$^+$ ions, using radon-polonium coincidences from the $^{238}$U chain identified in 532 live-days of DarkSide-50 WIMP-search data. The fraction of $^{218}$Po that is charged is found to be 0.37$\pm$0.03 and the mobility of $^{218}$Po$^+$ is (8.6$\pm$0.1)…
▽ More
We report measurements of the charged daughter fraction of $^{218}$Po as a result of the $^{222}$Rn alpha decay, and the mobility of $^{218}$Po$^+$ ions, using radon-polonium coincidences from the $^{238}$U chain identified in 532 live-days of DarkSide-50 WIMP-search data. The fraction of $^{218}$Po that is charged is found to be 0.37$\pm$0.03 and the mobility of $^{218}$Po$^+$ is (8.6$\pm$0.1)$\times$10$^{-4}$$\frac{\text{cm}^2}{\text{Vs}}$.
△ Less
Submitted 28 October, 2019; v1 submitted 22 July, 2019;
originally announced July 2019.
-
Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood Fit
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
S. Banik,
D. Barker,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
J. Cooley,
B. Cornell,
P. Cushman,
F. De Brienne,
T. Doughty
, et al. (78 additional authors not shown)
Abstract:
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than…
▽ More
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than was used for the two previous CDMSlite data sets. This analysis includes a data "salting" method to protect against bias, improved noise discrimination, background modeling, and the use of profile likelihood methods to search for a dark matter signal in the presence of backgrounds. We achieve an energy threshold of 70 eV and significantly improve the sensitivity for dark matter particles with masses between 2.5 and 10 GeV/c$^2$ compared to previous analyses. We set an upper limit on the dark matter-nucleon scattering cross section in germanium of 5.4$\times$10$^{-42}$ cm$^2$ at 5 GeV/c$^2$, a factor of $\sim$2.5 improvement over the previous CDMSlite result.
△ Less
Submitted 2 January, 2021; v1 submitted 27 August, 2018;
originally announced August 2018.
-
First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive Detector
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
S. Banik,
D. Barker,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
Y. -Y. Chang,
J. Cooley,
B. Cornell,
P. Cushman,
P. C. F. Di Stefano,
T. Doughty,
E. Fascione
, et al. (77 additional authors not shown)
Abstract:
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensit…
▽ More
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensitivity to dark photons competitive with other leading approaches but using substantially less exposure (0.49 gram days). These results demonstrate the scientific potential of phonon-mediated semiconductor detectors that are sensitive to single electronic excitations.
△ Less
Submitted 22 December, 2020; v1 submitted 27 April, 2018;
originally announced April 2018.
-
Surface background suppression in liquid argon dark matter detectors using a newly discovered time component of tetraphenyl-butadiene scintillation
Authors:
Chris Stanford,
Shawn Westerdale,
**gke Xu,
Frank Calaprice
Abstract:
Decays of radioisotopes on inner detector surfaces can pose a major background concern for the direct detection of dark matter. While these backgrounds are conventionally mitigated with position cuts, these cuts reduce the exposure of the detector by decreasing the sensitive mass, and uncertainty in position determination may make it impossible to adequately remove such events in certain detectors…
▽ More
Decays of radioisotopes on inner detector surfaces can pose a major background concern for the direct detection of dark matter. While these backgrounds are conventionally mitigated with position cuts, these cuts reduce the exposure of the detector by decreasing the sensitive mass, and uncertainty in position determination may make it impossible to adequately remove such events in certain detectors. In this paper, we provide a new technique for substantially reducing these surface backgrounds in liquid argon (LAr) detectors, independent of position cuts. These detectors typically use a coating of tetraphenyl-butadiene (TPB) on the inner surfaces as a wavelength shifter to convert vacuum ultraviolet (VUV) LAr scintillation light to the visible spectrum. We find that TPB scintillation contains a component with a previously unreported exceptionally long lifetime ($\sim$ms). We discovered that this component differs significantly in magnitude between alpha, beta, and VUV excitation, which enables the use of pulse shape discrimination to suppress surface backgrounds by more than a factor of $10^3$ with negligible loss of dark matter sensitivity. We also discuss how this technique can be extended beyond just LAr experiments.
△ Less
Submitted 8 April, 2019; v1 submitted 16 April, 2018;
originally announced April 2018.
-
Electroluminescence pulse shape and electron diffusion in liquid argon measured in a dual-phase TPC
Authors:
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
D. M. Asner,
M. P. Ave,
H. O. Back,
B. Baldin,
G. Batignani,
K. Biery,
V. Bocci,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino,
F. Budano,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
A. Caminata,
N. Canci,
A. Candela,
M. Caravati,
M. Cariello
, et al. (141 additional authors not shown)
Abstract:
We report the measurement of the longitudinal diffusion constant in liquid argon with the DarkSide-50 dual-phase time projection chamber. The measurement is performed at drift electric fields of 100 V/cm, 150 V/cm, and 200 V/cm using high statistics $^{39}$Ar decays from atmospheric argon. We derive an expression to describe the pulse shape of the electroluminescence signal (S2) in dual-phase TPCs…
▽ More
We report the measurement of the longitudinal diffusion constant in liquid argon with the DarkSide-50 dual-phase time projection chamber. The measurement is performed at drift electric fields of 100 V/cm, 150 V/cm, and 200 V/cm using high statistics $^{39}$Ar decays from atmospheric argon. We derive an expression to describe the pulse shape of the electroluminescence signal (S2) in dual-phase TPCs. The derived S2 pulse shape is fit to events from the uppermost portion of the TPC in order to characterize the radial dependence of the signal. The results are provided as inputs to the measurement of the longitudinal diffusion constant DL, which we find to be (4.12 $\pm$ 0.04) cm$^2$/s for a selection of 140keV electron recoil events in 200V/cm drift field and 2.8kV/cm extraction field. To study the systematics of our measurement we examine datasets of varying event energy, field strength, and detector volume yielding a weighted average value for the diffusion constant of (4.09 $\pm$ 0.09) cm$^2$ /s. The measured longitudinal diffusion constant is observed to have an energy dependence, and within the studied energy range the result is systematically lower than other results in the literature.
△ Less
Submitted 23 July, 2018; v1 submitted 5 February, 2018;
originally announced February 2018.
-
The Electronics, Trigger and Data Acquisition System for the Liquid Argon Time Projection Chamber of the DarkSide-50 Search for Dark Matter
Authors:
DarkSide Collaboration,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
K. Arisaka,
D. M. Asner,
M. Ave,
H. O. Back,
B. Baldin,
K. Biery,
V. Bocci,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino,
A. Brigatti,
J. Brodsky,
F. Budano,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
N. Canci,
A. Candela
, et al. (155 additional authors not shown)
Abstract:
The DarkSide-50 experiment at the Laboratori Nazionali del Gran Sasso is a search for dark matter using a dual phase time projection chamber with 50 kg of low radioactivity argon as target. Light signals from interactions in the argon are detected by a system of 38 photo-multiplier tubes (PMTs), 19 above and 19 below the TPC volume inside the argon cryostat. We describe the electronics which proce…
▽ More
The DarkSide-50 experiment at the Laboratori Nazionali del Gran Sasso is a search for dark matter using a dual phase time projection chamber with 50 kg of low radioactivity argon as target. Light signals from interactions in the argon are detected by a system of 38 photo-multiplier tubes (PMTs), 19 above and 19 below the TPC volume inside the argon cryostat. We describe the electronics which processes the signals from the photo-multipliers, the trigger system which identifies events of interest, and the data-acquisition system which records the data for further analysis. The electronics include resistive voltage dividers on the PMTs, custom pre-amplifiers mounted directly on the PMT voltage dividers in the liquid argon, and custom amplifier/discriminators (at room temperature). After amplification, the PMT signals are digitized in CAEN waveform digitizers, and CAEN logic modules are used to construct the trigger, the data acquisition system for the TPC is based on the Fermilab "artdaq" software. The system has been in operation since early 2014.
△ Less
Submitted 20 November, 2017; v1 submitted 31 July, 2017;
originally announced July 2017.
-
DarkSide-20k: A 20 Tonne Two-Phase LAr TPC for Direct Dark Matter Detection at LNGS
Authors:
C. E. Aalseth,
F. Acerbi,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Antonioli,
S. Arcelli,
R. Ardito,
I. J. Arnquist,
D. M. Asner,
M. Ave,
H. O. Back,
A. I. Barrado Olmedo,
G. Batignani,
E. Bertoldo,
S. Bettarini,
M. G. Bisogni,
V. Bocci,
A. Bondar,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino
, et al. (260 additional authors not shown)
Abstract:
Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LArTPC) with an active (fiducial) mass of 23 t (20 t). The DarkSide-20k LArTPC will be deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a…
▽ More
Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LArTPC) with an active (fiducial) mass of 23 t (20 t). The DarkSide-20k LArTPC will be deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a cylindrical Water Cherenkov Veto (WCV). Operation of DarkSide-50 demonstrated a major reduction in the dominant $^{39}$Ar background when using argon extracted from an underground source, before applying pulse shape analysis. Data from DarkSide-50, in combination with MC simulation and analytical modeling, shows that a rejection factor for discrimination between electron and nuclear recoils of $\gt3\times10^9$ is achievable. This, along with the use of the veto system, is the key to unlocking the path to large LArTPC detector masses, while maintaining an "instrumental background-free" experiment, an experiment in which less than 0.1 events (other than $ν$-induced nuclear recoils) is expected to occur within the WIMP search region during the planned exposure. DarkSide-20k will have ultra-low backgrounds than can be measured in situ. This will give sensitivity to WIMP-nucleon cross sections of $1.2\times10^{-47}$ cm$^2$ ($1.1\times10^{-46}$ cm$^2$) for WIMPs of $1$ TeV$/c^2$ ($10$ TeV$/c^2$) mass, to be achieved during a 5 yr run producing an exposure of 100 t yr free from any instrumental background. DarkSide-20k could then extend its operation to a decade, increasing the exposure to 200 t yr, reaching a sensitivity of $7.4\times10^{-48}$ cm$^2$ ($6.9\times10^{-47}$ cm$^2$) for WIMPs of $1$ TeV$/c^2$ ($10$ TeV$/c^2$) mass.
△ Less
Submitted 25 July, 2017;
originally announced July 2017.
-
Simulation of argon response and light detection in the DarkSide-50 dual phase TPC
Authors:
The DarkSide Collaboration,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
D. M. Asner,
H. O. Back,
K. Biery,
V. Bocci,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino,
F. Budano,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
N. Canci,
A. Candela,
M. Caravati,
M. Cariello,
M. Carlini,
S. Catalanotti,
V. Cataudella
, et al. (125 additional authors not shown)
Abstract:
A Geant4-based Monte Carlo package named G4DS has been developed to simulate the response of DarkSide-50, an experiment operating since 2013 at LNGS, designed to detect WIMP interactions in liquid argon. In the process of WIMP searches, DarkSide-50 has achieved two fundamental milestones: the rejection of electron recoil background with a power of ~10^7, using the pulse shape discrimination techni…
▽ More
A Geant4-based Monte Carlo package named G4DS has been developed to simulate the response of DarkSide-50, an experiment operating since 2013 at LNGS, designed to detect WIMP interactions in liquid argon. In the process of WIMP searches, DarkSide-50 has achieved two fundamental milestones: the rejection of electron recoil background with a power of ~10^7, using the pulse shape discrimination technique, and the measurement of the residual 39Ar contamination in underground argon, ~3 orders of magnitude lower with respect to atmospheric argon. These results rely on the accurate simulation of the detector response to the liquid argon scintillation, its ionization, and electron-ion recombination processes. This work provides a complete overview of the DarkSide Monte Carlo and of its performance, with a particular focus on PARIS, the custom-made liquid argon response model.
△ Less
Submitted 26 September, 2017; v1 submitted 18 July, 2017;
originally announced July 2017.
-
Cryogenic Characterization of FBK RGB-HD SiPMs
Authors:
C. E. Aalseth,
F. Acerbi,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. Alici,
A. K. Alton,
P. Ampudia,
P. Antonioli,
S. Arcelli,
R. Ardito,
I. J. Arnquist,
D. M. Asner,
H. O. Back,
G. Batignani,
E. Bertoldo,
S. Bettarini,
M. G. Bisogni,
V. Bocci,
A. Bondar,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino,
R. Bunker
, et al. (246 additional authors not shown)
Abstract:
We report on the cryogenic characterization of Red Green Blue - High Density (RGB-HD) SiPMs developed at Fondazione Bruno Kessler (FBK) as part of the DarkSide program of dark matter searches with liquid argon time projection chambers. A dedicated setup was used to measure the primary dark noise, the correlated noise, and the gain of the SiPMs at varying temperatures. A custom-made data acquisitio…
▽ More
We report on the cryogenic characterization of Red Green Blue - High Density (RGB-HD) SiPMs developed at Fondazione Bruno Kessler (FBK) as part of the DarkSide program of dark matter searches with liquid argon time projection chambers. A dedicated setup was used to measure the primary dark noise, the correlated noise, and the gain of the SiPMs at varying temperatures. A custom-made data acquisition system and analysis software were used to precisely characterize these parameters. We demonstrate that FBK RGB-HD SiPMs with low quenching resistance (RGB-HD-LR$_q$) can be operated from 40 K to 300 K with gains in the range $10^5$ to $10^6$ and noise rates on the order of a few Hz/mm$^2$.
△ Less
Submitted 12 September, 2017; v1 submitted 19 May, 2017;
originally announced May 2017.
-
CALIS - a CALibration Insertion System for the DarkSide-50 dark matter search experiment
Authors:
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
D. M. Asner,
H. O. Back,
B. Baldin,
K. Biery,
V. Bocci,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino,
A. Brigatti,
J. Brodsky,
F. Budano,
S. Bussino,
M. Cadeddu,
L. Cadonati,
M. Cadoni,
F. Calaprice,
N. Canci,
A. Candela,
M. Caravati,
M. Cariello
, et al. (140 additional authors not shown)
Abstract:
This paper describes the design, fabrication, commissioning and use of a CALibration source Insertion System (CALIS) in the DarkSide-50 direct dark matter search experiment. CALIS deploys radioactive sources into the liquid scintillator veto to characterize the detector response and detection efficiency of the DarkSide-50 Liquid Argon Time Projection Chamber, and the surrounding 30 t organic liqui…
▽ More
This paper describes the design, fabrication, commissioning and use of a CALibration source Insertion System (CALIS) in the DarkSide-50 direct dark matter search experiment. CALIS deploys radioactive sources into the liquid scintillator veto to characterize the detector response and detection efficiency of the DarkSide-50 Liquid Argon Time Projection Chamber, and the surrounding 30 t organic liquid scintillator neutron veto. It was commissioned in September 2014 and has been used successfully in several gamma and neutron source campaigns since then. A description of the hardware and an excerpt of calibration analysis results are given below.
△ Less
Submitted 27 September, 2017; v1 submitted 8 November, 2016;
originally announced November 2016.
-
Effect of Low Electric Fields on Alpha Scintillation Light Yield in Liquid Argon
Authors:
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
D. M. Asner,
H. O. Back,
B. Baldin,
K. Biery,
V. Bocci,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino,
A. Brigatti,
J. Brodsky,
F. Budano,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
N. Canci,
A. Candela,
M. Caravati,
M. Cariello,
M. Carlini
, et al. (136 additional authors not shown)
Abstract:
Measurements were made of scintillation light yield of alpha particles from the $^{222}$Rn decay chain within the DarkSide-50 liquid argon time projection chamber. The light yield was found to increase as the applied electric field increased, with alphas in a 200 V/cm electric field exhibiting a 2% increase in light yield compared to alphas in no field.
Measurements were made of scintillation light yield of alpha particles from the $^{222}$Rn decay chain within the DarkSide-50 liquid argon time projection chamber. The light yield was found to increase as the applied electric field increased, with alphas in a 200 V/cm electric field exhibiting a 2% increase in light yield compared to alphas in no field.
△ Less
Submitted 4 November, 2016; v1 submitted 1 November, 2016;
originally announced November 2016.
-
First measurement of surface nuclear recoil background for argon dark matter searches
Authors:
**gke Xu,
Chris Stanford,
Shawn Westerdale,
Frank Calaprice,
Alexander Wright,
Zhiming Shi
Abstract:
One major background in direct searches for weakly interacting massive particles (WIMPs) comes from the deposition of radon progeny on detector surfaces. The most dangerous surface background is the $^{206}$Pb recoils produced by $^{210}$Po decays. In this letter, we report the first characterization of this background in liquid argon. The scintillation signal of low energy Pb recoils is measured…
▽ More
One major background in direct searches for weakly interacting massive particles (WIMPs) comes from the deposition of radon progeny on detector surfaces. The most dangerous surface background is the $^{206}$Pb recoils produced by $^{210}$Po decays. In this letter, we report the first characterization of this background in liquid argon. The scintillation signal of low energy Pb recoils is measured to be highly quenched in argon, and we estimate that the 103keV $^{206}$Pb recoil background will produce a signal equal to that of a ~5keV (30keV) electron recoil ($^{40}$Ar recoil). In addition, we demonstrate that this dangerous $^{210}$Po surface background can be suppressed by a factor of ~100 or higher using pulse shape discrimination methods, which can make argon dark matter detectors near background-free and enhance their potential for discovery of medium- and high-mass WIMPs. We also discuss the impact on other low background experiments.
△ Less
Submitted 22 September, 2016;
originally announced September 2016.
-
The Electronics and Data Acquisition System for the DarkSide-50 Veto Detectors
Authors:
P. Agnes,
L. Agostino,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
K. Arisaka,
H. O. Back,
B. Baldin,
K. Biery,
G. Bonfini,
M. Bossa,
B. Bottino,
A. Brigatti,
J. Brodsky,
F. Budano,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
N. Canci,
A. Candela,
H. Cao,
M. Cariello,
M. Carlini,
S. Catalanotti
, et al. (133 additional authors not shown)
Abstract:
DarkSide-50 is a detector for dark matter candidates in the form of weakly interacting massive particles (WIMPs). It utilizes a liquid argon time projection chamber (LAr TPC) for the inner main detector. The TPC is surrounded by a liquid scintillator veto (LSV) and a water Cherenkov veto detector (WCV). The LSV and WCV, both instrumented with PMTs, act as the neutron and cosmogenic muon veto detec…
▽ More
DarkSide-50 is a detector for dark matter candidates in the form of weakly interacting massive particles (WIMPs). It utilizes a liquid argon time projection chamber (LAr TPC) for the inner main detector. The TPC is surrounded by a liquid scintillator veto (LSV) and a water Cherenkov veto detector (WCV). The LSV and WCV, both instrumented with PMTs, act as the neutron and cosmogenic muon veto detectors for DarkSide-50. This paper describes the electronics and data acquisition system used for these two detectors.
△ Less
Submitted 10 June, 2016;
originally announced June 2016.
-
The veto system of the DarkSide-50 experiment
Authors:
The DarkSide Collaboration,
P. Agnes,
L. Agostino,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
K. Arisaka,
H. O. Back,
B. Baldin,
K. Biery,
G. Bonfini,
M. Bossa,
B. Bottino,
A. Brigatti,
J. Brodsky,
F. Budano,
S. Bussino,
M. Cadeddu,
L. Cadonati,
M. Cadoni,
F. Calaprice,
N. Canci,
A. Candela,
H. Cao,
M. Cariello
, et al. (136 additional authors not shown)
Abstract:
Nuclear recoil events produced by neutron scatters form one of the most important classes of background in WIMP direct detection experiments, as they may produce nuclear recoils that look exactly like WIMP interactions. In DarkSide-50, we both actively suppress and measure the rate of neutron-induced background events using our neutron veto, composed of a boron-loaded liquid scintillator detector…
▽ More
Nuclear recoil events produced by neutron scatters form one of the most important classes of background in WIMP direct detection experiments, as they may produce nuclear recoils that look exactly like WIMP interactions. In DarkSide-50, we both actively suppress and measure the rate of neutron-induced background events using our neutron veto, composed of a boron-loaded liquid scintillator detector within a water Cherenkov detector. This paper is devoted to the description of the neutron veto system of DarkSide-50, including the detector structure, the fundamentals of event reconstruction and data analysis, and basic performance parameters.
△ Less
Submitted 24 December, 2015;
originally announced December 2015.
-
Results from the first use of low radioactivity argon in a dark matter search
Authors:
The DarkSide Collaboration,
P. Agnes,
L. Agostino,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
K. Arisaka,
H. O. Back,
B. Baldin,
K. Biery,
G. Bonfini,
M. Bossa,
B. Bottino,
A. Brigatti,
J. Brodsky,
F. Budano,
S. Bussino,
M. Cadeddu,
L. Cadonati,
M. Cadoni,
F. Calaprice,
N. Canci,
A. Candela,
H. Cao,
M. Cariello
, et al. (136 additional authors not shown)
Abstract:
Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using two-phase liquid argon time projection chamber, located at the La…
▽ More
Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using two-phase liquid argon time projection chamber, located at the Laboratori Nazionali del Gran Sasso. The underground argon is shown to contain Ar-39 at a level reduced by a factor (1.4 +- 0.2) x 10^3 relative to atmospheric argon. We report a background-free null result from (2616 +- 43) kg d of data, accumulated over 70.9 live-days. When combined with our previous search using an atmospheric argon, the 90 % C.L. upper limit on the WIMP-nucleon spin-independent cross section based on zero events found in the WIMP search regions, is 2.0 x 10^-44 cm^2 (8.6 x 10^-44 cm^2, 8.0 x 10^-43 cm^2) for a WIMP mass of 100 GeV/c^2 (1 TeV/c^2 , 10 TeV/c^2).
△ Less
Submitted 13 April, 2016; v1 submitted 2 October, 2015;
originally announced October 2015.
-
The Electronics and Data Acquisition System of the DarkSide Dark Matter Search
Authors:
The DarkSide Collaboration,
P. Agnes,
T. Alexander,
A. Alton,
K. Arisaka,
H. O. Back,
B. Baldin,
K. Biery,
G. Bonfini,
M. Bossa,
A. Brigatti,
J. Brodsky,
F. Budano,
L. Cadonati,
F. Calaprice,
N. Canci,
A. Candela,
H. Cao,
M. Cariello,
P. Cavalcante,
A. Chavarria,
A. Chepurnov,
A. G. Cocco,
L. Crippa,
D. D'Angelo
, et al. (121 additional authors not shown)
Abstract:
It is generally inferred from astronomical measurements that Dark Matter (DM) comprises approximately 27\% of the energy-density of the universe. If DM is a subatomic particle, a possible candidate is a Weakly Interacting Massive Particle (WIMP), and the DarkSide-50 (DS) experiment is a direct search for evidence of WIMP-nuclear collisions. DS is located underground at the Laboratori Nazionali del…
▽ More
It is generally inferred from astronomical measurements that Dark Matter (DM) comprises approximately 27\% of the energy-density of the universe. If DM is a subatomic particle, a possible candidate is a Weakly Interacting Massive Particle (WIMP), and the DarkSide-50 (DS) experiment is a direct search for evidence of WIMP-nuclear collisions. DS is located underground at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, and consists of three active, embedded components; an outer water veto (CTF), a liquid scintillator veto (LSV), and a liquid argon (LAr) time projection chamber (TPC). This paper describes the data acquisition and electronic systems of the DS detectors, designed to detect the residual ionization from such collisions.
△ Less
Submitted 22 January, 2015; v1 submitted 9 December, 2014;
originally announced December 2014.
-
First Results from the DarkSide-50 Dark Matter Experiment at Laboratori Nazionali del Gran Sasso
Authors:
P. Agnes,
T. Alexander,
A. Alton,
K. Arisaka,
H. O. Back,
B. Baldin,
K. Biery,
G. Bonfini,
M. Bossa,
A. Brigatti,
J. Brodsky,
F. Budano,
L. Cadonati,
F. Calaprice,
N. Canci,
A. Candela,
H. Cao,
M. Cariello,
P. Cavalcante,
A. Chavarria,
A. Chepurnov,
A. G. Cocco,
L. Crippa,
D. D'Angelo,
M. D'Incecco
, et al. (121 additional authors not shown)
Abstract:
We report the first results of DarkSide-50, a direct search for dark matter operating in the underground Laboratori Nazionali del Gran Sasso (LNGS) and searching for the rare nuclear recoils possibly induced by weakly interacting massive particles (WIMPs). The dark matter detector is a Liquid Argon Time Projection Chamber with a (46.4+-0.7) kg active mass, operated inside a 30 t organic liquid sci…
▽ More
We report the first results of DarkSide-50, a direct search for dark matter operating in the underground Laboratori Nazionali del Gran Sasso (LNGS) and searching for the rare nuclear recoils possibly induced by weakly interacting massive particles (WIMPs). The dark matter detector is a Liquid Argon Time Projection Chamber with a (46.4+-0.7) kg active mass, operated inside a 30 t organic liquid scintillator neutron veto, which is in turn installed at the center of a 1 kt water Cherenkov veto for the residual flux of cosmic rays. We report here the null results of a dark matter search for a (1422+-67) kg d exposure with an atmospheric argon fill. This is the most sensitive dark matter search performed with an argon target, corresponding to a 90% CL upper limit on the WIMP-nucleon spin-independent cross section of 6.1x10^-44 cm^2 for a WIMP mass of 100 GeV/c^2.
△ Less
Submitted 27 February, 2015; v1 submitted 2 October, 2014;
originally announced October 2014.