-
Performance of a modular ton-scale pixel-readout liquid argon time projection chamber
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade
, et al. (1340 additional authors not shown)
Abstract:
The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmi…
▽ More
The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements, and provide comparisons to detector simulations.
△ Less
Submitted 5 March, 2024;
originally announced March 2024.
-
Do** Liquid Argon with Xenon in ProtoDUNE Single-Phase: Effects on Scintillation Light
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
H. Amar Es-sghir,
P. Amedo,
J. Anderson,
D. A. Andrade,
C. Andreopoulos
, et al. (1300 additional authors not shown)
Abstract:
Do** of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first do** test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUN…
▽ More
Do** of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first do** test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 770 t of total liquid argon mass with 410 t of fiducial mass. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of non-uniformities in light collection, caused by deployment of photon detectors only within the anode planes. Light collection was analysed as a function of the xenon concentration, by using the pre-existing photon detection system (PDS) of ProtoDUNE-SP and an additional smaller set-up installed specifically for this run. In this paper we first summarize our current understanding of the argon-xenon energy transfer process and the impact of the presence of nitrogen in argon with and without xenon dopant. We then describe the key elements of ProtoDUNE-SP and the injection method deployed. Two dedicated photon detectors were able to collect the light produced by xenon and the total light. The ratio of these components was measured to be about 0.65 as 18.8 ppm of xenon were injected. We performed studies of the collection efficiency as a function of the distance between tracks and light detectors, demonstrating enhanced uniformity of response for the anode-mounted PDS. We also show that xenon do** can substantially recover light losses due to contamination of the liquid argon by nitrogen.
△ Less
Submitted 9 February, 2024; v1 submitted 2 February, 2024;
originally announced February 2024.
-
The Mu2e crystal and SiPM calorimeter: construction status
Authors:
Nikolay Atanov,
Vladimir Baranov,
Leo Borrel,
Caterina Bloise,
Julian Budagov,
Sergio Ceravol,
Franco Cervelli,
Francesco Colao,
Marco Cordelli,
Giovanni Corradi,
Yuri Davydov,
Stefano Di Falco,
Eleonora Diociaiuti,
Simone Donati,
Bertrand Echenard,
Carlo Ferrari,
Ruben Gargiulo,
Antonio Gioiosa,
Simona Giovannella,
Valerio Giusti,
Vladimir Glagolev,
Francesco Grancagnolo,
Dariush Hampai,
Fabio Happacher,
David Hitlin
, et al. (15 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab searches for the neutrino-less conversion of a negative muon into an electron, with a distinctive signature of a mono-energetic electron with energy of 104.967 MeV. The calorimeter is made of two disks of pure CsI crystals, each read out by two custom large area UV-extended SiPMs. It plays a fundamental role in providing excellent particle identification capabilitie…
▽ More
The Mu2e experiment at Fermilab searches for the neutrino-less conversion of a negative muon into an electron, with a distinctive signature of a mono-energetic electron with energy of 104.967 MeV. The calorimeter is made of two disks of pure CsI crystals, each read out by two custom large area UV-extended SiPMs. It plays a fundamental role in providing excellent particle identification capabilities and an online trigger filter while improving the track reconstruction, requiring better than 10% energy and 500 ps timing resolutions for 100 MeV electrons. In this paper, we present the status of construction and the Quality Control (QC) performed on the produced crystals and photosensors, the development of the rad-hard electronics, and the most important results of the irradiation tests. Construction of the mechanics is also reported. Status and plans for the calorimeter assembly and its first commissioning are described.
△ Less
Submitted 28 January, 2024;
originally announced January 2024.
-
The DUNE Far Detector Vertical Drift Technology, Technical Design Report
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade,
C. Andreopoulos
, et al. (1304 additional authors not shown)
Abstract:
DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precisi…
▽ More
DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precision measurements of the PMNS matrix parameters, including the CP-violating phase. It will also stand ready to observe supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model.
The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines the many tens-of-kiloton fiducial mass necessary for rare event searches with the sub-centimeter spatial resolution required to image those events with high precision. The addition of a photon detection system enhances physics capabilities for all DUNE physics drivers and opens prospects for further physics explorations. Given its size, the far detector will be implemented as a set of modules, with LArTPC designs that differ from one another as newer technologies arise.
In the vertical drift LArTPC design, a horizontal cathode bisects the detector, creating two stacked drift volumes in which ionization charges drift towards anodes at either the top or bottom. The anodes are composed of perforated PCB layers with conductive strips, enabling reconstruction in 3D. Light-trap-style photon detection modules are placed both on the cryostat's side walls and on the central cathode where they are optically powered.
This Technical Design Report describes in detail the technical implementations of each subsystem of this LArTPC that, together with the other far detector modules and the near detector, will enable DUNE to achieve its physics goals.
△ Less
Submitted 5 December, 2023;
originally announced December 2023.
-
HIKE, High Intensity Kaon Experiments at the CERN SPS
Authors:
E. Cortina Gil,
J. Jerhot,
N. Lurkin,
T. Numao,
B. Velghe,
V. W. S. Wong,
D. Bryman,
L. Bician,
Z. Hives,
T. Husek,
K. Kampf,
M. Koval,
A. T. Akmete,
R. Aliberti,
V. Büscher,
L. Di Lella,
N. Doble,
L. Peruzzo,
M. Schott,
H. Wahl,
R. Wanke,
B. Döbrich,
L. Montalto,
D. Rinaldi,
F. Dettori
, et al. (154 additional authors not shown)
Abstract:
A timely and long-term programme of kaon decay measurements at a new level of precision is presented, leveraging the capabilities of the CERN Super Proton Synchrotron (SPS). The proposed programme is firmly anchored on the experience built up studying kaon decays at the SPS over the past four decades, and includes rare processes, CP violation, dark sectors, symmetry tests and other tests of the St…
▽ More
A timely and long-term programme of kaon decay measurements at a new level of precision is presented, leveraging the capabilities of the CERN Super Proton Synchrotron (SPS). The proposed programme is firmly anchored on the experience built up studying kaon decays at the SPS over the past four decades, and includes rare processes, CP violation, dark sectors, symmetry tests and other tests of the Standard Model. The experimental programme is based on a staged approach involving experiments with charged and neutral kaon beams, as well as operation in beam-dump mode. The various phases will rely on a common infrastructure and set of detectors.
△ Less
Submitted 29 November, 2022;
originally announced November 2022.
-
An automated QC Station for the Calibration of the Mu2e Calorimeter Readout Units
Authors:
E. Sanzani,
C. Bloise,
S. Ceravolo,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
S. Di Falco,
E. Diociaiuti,
S. Donati,
C. Ferrari,
R. Gargiulo,
A. Gioiosa,
S. Giovannella,
V. Giusti,
D. Hampai,
F. Happacher,
M. Martini,
S. Miscetti,
L. Morescalchi,
D. Paesani,
D. Pasciuto,
E. Pedreschi,
F. Raffaelli,
I. Sarra
, et al. (3 additional authors not shown)
Abstract:
The Mu2e calorimeter will employ Readout Units, each made of two Silicon Photomultipliers arrays and two Front End Electronics boards. To calibrate them, we have designed, assembled and put in operation an automated Quality Control (QC) station. Gain, collected charge and photon detection efficiency are evaluated for each unit. In this paper, the QC Station is presented, in its hardware and softwa…
▽ More
The Mu2e calorimeter will employ Readout Units, each made of two Silicon Photomultipliers arrays and two Front End Electronics boards. To calibrate them, we have designed, assembled and put in operation an automated Quality Control (QC) station. Gain, collected charge and photon detection efficiency are evaluated for each unit. In this paper, the QC Station is presented, in its hardware and software aspects, summarizing also the tests performed on the ROUs and the first measurement results.
△ Less
Submitted 26 September, 2022;
originally announced September 2022.
-
Trigger-DAQ and Slow Controls Systems in the Mu2e Experiment
Authors:
A. Gioiosa,
S. Donati,
E. Flumerfelt,
G. Horton-Smith,
L. Morescalchi,
V. O'Dell,
E. Pedreschi,
G. Pezzullo,
F. Spinella,
L. Uplegger,
R. A. Rivera
Abstract:
The muon campus program at Fermilab includes the Mu2e experiment that will search for a charged-lepton flavor violating processes where a negative muon converts into an electron in the field of an aluminum nucleus, improving by four orders of magnitude the search sensitivity reached so far. Mu2e's Trigger and Data Acquisition System (TDAQ) uses otsdaq as its solution. Developed at Fermilab, otsdaq…
▽ More
The muon campus program at Fermilab includes the Mu2e experiment that will search for a charged-lepton flavor violating processes where a negative muon converts into an electron in the field of an aluminum nucleus, improving by four orders of magnitude the search sensitivity reached so far. Mu2e's Trigger and Data Acquisition System (TDAQ) uses otsdaq as its solution. Developed at Fermilab, otsdaq uses the artdaq DAQ framework and art analysis framework, under the-hood, for event transfer, filtering, and processing. otsdaq is an online DAQ software suite with a focus on flexibility and scalability, while providing a multi-user, web-based, interface accessible through the Chrome or Firefox web browser. The detector Read Out Controller (ROC), from the tracker and calorimeter, stream out zero-suppressed data continuously to the Data Transfer Controller (DTC). Data is then read over the PCIe bus to a software filter algorithm that selects events which are finally combined with the data flux that comes froma Cosmic Ray Ve to System (CRV). A Detector Control System (DCS) for monitoring, controlling, alarming, and archiving has been developed using the Experimental Physics and Industrial Control System (EPICS) Open Source Platform. The DCS System has also been itegrated into otsdaq. The installation of the TDAQ and the DCS systems in the Mu2e building is planned for 2021-2022, and a prototype has been built at Fermilab's Feynman Computing Center. We report here on the developments and achievements of the integration of Mu2e's DCS system into the online otsdaq software.
△ Less
Submitted 30 October, 2020;
originally announced October 2020.
-
Mechanical Ventilator Milano (MVM): A Novel Mechanical Ventilator Designed for Mass Scale Production in Response to the COVID-19 Pandemic
Authors:
C. Galbiati,
A. Abba,
P. Agnes,
P. Amaudruz,
M. Arba,
F. Ardellier-Desages,
C. Badia,
G. Batignani,
G. Bellani,
G. Bianchi,
D. Bishop,
V. Bocci,
W. Bonivento,
B. Bottino,
M. Bouchard,
S. Brice,
G. Buccino,
S. Bussino,
A. Caminata,
A. Capra,
M. Caravati,
M. Carlini,
L. Carrozzi,
J. M. Cela,
B. Celano
, et al. (123 additional authors not shown)
Abstract:
Presented here is the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for rapid mass production in response to the COVID-19 pandemic to address the urgent shortage of intensive therapy ventilators in many countries, and the growing difficulty in procuring these devices through normal supply chains across borders. This ventilator is an electro-mechanical equ…
▽ More
Presented here is the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for rapid mass production in response to the COVID-19 pandemic to address the urgent shortage of intensive therapy ventilators in many countries, and the growing difficulty in procuring these devices through normal supply chains across borders. This ventilator is an electro-mechanical equivalent of the old and reliable Manley Ventilator, and is able to operate in both pressure-controlled and pressure-supported ventilation modes. MVM is optimized for the COVID-19 emergency, thanks to the collaboration with medical doctors in the front line. MVM is designed for large-scale production in a short amount of time and at a limited cost, as it relays on off-the-shelf components, readily available worldwide. Operation of the MVM requires only a source of compressed oxygen (or compressed medical air) and electrical power. Initial tests of a prototype device with a breathing simulator are also presented. Further tests and developments are underway. At this stage the MVM is not yet a certified medical device but certification is in progress.
△ Less
Submitted 10 April, 2020; v1 submitted 23 March, 2020;
originally announced March 2020.
-
Mu2e calorimeter readout system
Authors:
N. Atanov,
V. Baranov,
L. Baldini,
J. Budagov,
D. Caiulo,
F. Cei,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
Yu. I. Davydov,
F. D'Errico,
S. Di Falco,
E. Diociaiuti,
S. Donati,
R. Donghia,
B. Echenard,
S. Faetti,
S. Giovannella,
S. Giudici,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. G. Hitlin,
L. Lazzeri
, et al. (21 additional authors not shown)
Abstract:
The Mu2e electromagnetic calorimeter is made of two disks of un-doped parallelepiped CsI crystals readout by SiPM. There are 674 crystals in one disk and each crystal is readout by an array of two SiPM. The readout electronics is composed of two types of modules: 1) the front-end module hosts the sha** amplifier and the high voltage linear regulator; since one front-end module is interfaced to o…
▽ More
The Mu2e electromagnetic calorimeter is made of two disks of un-doped parallelepiped CsI crystals readout by SiPM. There are 674 crystals in one disk and each crystal is readout by an array of two SiPM. The readout electronics is composed of two types of modules: 1) the front-end module hosts the sha** amplifier and the high voltage linear regulator; since one front-end module is interfaced to one SiPM, a total of 2696 modules are needed for the entire calorimeter; 2) a waveform digitizer provides a further level of amplification and digitizes the SiPM signal at the sampling frequency of $200\ \text{M}\text{Hz}$ with 12-bits ADC resolution; since one board digitizes the data received from 20 SiPMs, a total of 136 boards are needed. The readout system operational conditions are hostile: ionization dose of $20\ \text{krads}$, neutron flux of $10^{12}\ \mathrm{n}(1\ \text{MeVeq})/\text{cm}^2$, magnetic field of $1\ \text{T}$ and in vacuum level of $10^{-4}\ \text{Torr}$. A description of the readout system and qualification tests is reported.
△ Less
Submitted 9 July, 2019;
originally announced July 2019.
-
The integrated low-level trigger and readout system of the CERN NA62 experiment
Authors:
R. Ammendola,
B. Angelucci,
M. Barbanera,
A. Biagioni,
V. Cerny,
B. Checcucci,
R. Fantechi,
F. Gonnella,
M. Koval,
M. Krivda,
G. Lamanna,
M. Lupi,
A. Lonardo,
A. Papi,
C. Parkinson,
E. Pedreschi,
P. Petrov,
R. Piandani,
J. Pinzino,
L. Pontisso,
M. Raggi,
D. Soldi,
M. S. Sozzi,
F. Spinella,
S. Venditti
, et al. (1 additional authors not shown)
Abstract:
The integrated low-level trigger and data acquisition (TDAQ) system of the NA62 experiment at CERN is described. The requirements of a large and fast data reduction in a high-rate environment for a medium-scale, distributed ensemble of many different sub-detectors led to the concept of a fully digital integrated system with good scaling capabilities. The NA62 TDAQ system is rather unique in allowi…
▽ More
The integrated low-level trigger and data acquisition (TDAQ) system of the NA62 experiment at CERN is described. The requirements of a large and fast data reduction in a high-rate environment for a medium-scale, distributed ensemble of many different sub-detectors led to the concept of a fully digital integrated system with good scaling capabilities. The NA62 TDAQ system is rather unique in allowing full flexibility on this scale, allowing in principle any information available from the detector to be used for triggering. The design concept, implementation and performances from the first years of running are illustrated.
△ Less
Submitted 25 March, 2019;
originally announced March 2019.
-
The Mu2e calorimeter: quality assurance of production crystals and SiPMs
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
D. Caiulo,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
Yu. I. Davydov,
S. Di Falco,
E. Diociaiuti,
S. Donati,
R. Donghia,
B. Echenard,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. G. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
P. Murat,
E. Pedreschi
, et al. (12 additional authors not shown)
Abstract:
The Mu2e calorimeter is composed of two disks each containing 1348 pure CsI crystals, each crystal read out by two arrays of 6x6 mm2 monolithic SiPMs. The experimental requirements have been translated in a series of technical specifications for both crystals and SiPMs. Quality assurance tests, on first crystal and then SiPM production batches, confirm the performances of preproduction samples pre…
▽ More
The Mu2e calorimeter is composed of two disks each containing 1348 pure CsI crystals, each crystal read out by two arrays of 6x6 mm2 monolithic SiPMs. The experimental requirements have been translated in a series of technical specifications for both crystals and SiPMs. Quality assurance tests, on first crystal and then SiPM production batches, confirm the performances of preproduction samples previously assembled in a calorimeter prototype and tested with an electron beam. The production yield is sufficient to allow the construction of a calorimeter of the required quality in the expected times.
△ Less
Submitted 19 December, 2018;
originally announced December 2018.
-
Search for $K^{+}\rightarrowπ^{+}ν\overlineν$ at NA62
Authors:
NA62 Collaboration,
G. Aglieri Rinella,
R. Aliberti,
F. Ambrosino,
R. Ammendola,
B. Angelucci,
A. Antonelli,
G. Anzivino,
R. Arcidiacono,
I. Azhinenko,
S. Balev,
M. Barbanera,
J. Bendotti,
A. Biagioni,
L. Bician,
C. Biino,
A. Bizzeti,
T. Blazek,
A. Blik,
B. Bloch-Devaux,
V. Bolotov,
V. Bonaiuto,
M. Boretto,
M. Bragadireanu,
D. Britton
, et al. (227 additional authors not shown)
Abstract:
$K^{+}\rightarrowπ^{+}ν\overlineν$ is one of the theoretically cleanest meson decay where to look for indirect effects of new physics complementary to LHC searches. The NA62 experiment at CERN SPS is designed to measure the branching ratio of this decay with 10\% precision. NA62 took data in pilot runs in 2014 and 2015 reaching the final designed beam intensity. The quality of 2015 data acquired,…
▽ More
$K^{+}\rightarrowπ^{+}ν\overlineν$ is one of the theoretically cleanest meson decay where to look for indirect effects of new physics complementary to LHC searches. The NA62 experiment at CERN SPS is designed to measure the branching ratio of this decay with 10\% precision. NA62 took data in pilot runs in 2014 and 2015 reaching the final designed beam intensity. The quality of 2015 data acquired, in view of the final measurement, will be presented.
△ Less
Submitted 24 July, 2018;
originally announced July 2018.
-
Quality Assurance on Un-Doped CsI Crystals for the Mu2e Experiment
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
Yu. I. Davydov,
V. Glagolev,
V. Tereshchenko,
Z. Usubov,
F. Cervelli,
S. Di Falco,
S. Donati,
L. Morescalchi,
E. Pedreschi,
G. Pezzullo,
F. Raffaelli,
F. Spinella,
F. Colao,
M. Cordelli,
G. Corradi,
E. Diociaiuti,
R. Donghia,
S. Giovannella,
F. Happacher,
M. Martini,
S. Miscetti,
M. Ricci
, et al. (12 additional authors not shown)
Abstract:
The Mu2e experiment is constructing a calorimeter consisting of 1,348 undoped CsI crystals in two disks. Each crystal has a dimension of 34 x 34 x 200 mm, and is readout by a large area silicon PMT array. A series of technical specifications was defined according to physics requirements. Preproduction CsI crystals were procured from three firms: Amcrys, Saint-Gobain and Shanghai Institute of Ceram…
▽ More
The Mu2e experiment is constructing a calorimeter consisting of 1,348 undoped CsI crystals in two disks. Each crystal has a dimension of 34 x 34 x 200 mm, and is readout by a large area silicon PMT array. A series of technical specifications was defined according to physics requirements. Preproduction CsI crystals were procured from three firms: Amcrys, Saint-Gobain and Shanghai Institute of Ceramics. We report the quality assurance on crystal's scintillation properties and their radiation hardness against ionization dose and neutrons. With a fast decay time of 30 ns and a light output of more than 100 p.e./MeV measured with a bi-alkali PMT, undoped CsI crystals provide a cost-effective solution for the Mu2e experiment.
△ Less
Submitted 21 February, 2018;
originally announced February 2018.
-
Design and status of the Mu2e crystal calorimeter
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
Yu. I. Davydov,
V. Glagolev,
V. Tereshchenko,
Z. Usubov,
F. Cervelli,
S. Di Falco,
S. Donati,
L. Morescalchi,
E. Pedreschi,
G. Pezzullo,
F. Raffaelli,
F. Spinella,
F. Colao,
M. Cordelli,
G. Corradi,
E. Diociaiuti,
R. Donghia,
S. Giovannella,
F. Happacher,
M. Martini,
S. Miscetti,
M. Ricci
, et al. (10 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab searches for the charged-lepton flavour violating (CLFV) conversion of a negative muon into an electron in the field of an aluminum nucleus, with a distinctive signature of a mono-energetic electron of energy slightly below the muon rest mass (104.967 MeV). The Mu2e goal is to improve by four orders of magnitude the search sensitivity with respect to the previous ex…
▽ More
The Mu2e experiment at Fermilab searches for the charged-lepton flavour violating (CLFV) conversion of a negative muon into an electron in the field of an aluminum nucleus, with a distinctive signature of a mono-energetic electron of energy slightly below the muon rest mass (104.967 MeV). The Mu2e goal is to improve by four orders of magnitude the search sensitivity with respect to the previous experiments. Any observation of a CLFV signal will be a clear indication of new physics. The Mu2e detector is composed of a tracker, an electro- magnetic calorimeter and an external veto for cosmic rays surrounding the solenoid. The calorimeter plays an important role in providing particle identification capabilities, a fast online trigger filter, a seed for track reconstruction while working in vacuum, in the presence of 1 T axial magnetic field and in an harsh radiation environment. The calorimeter requirements are to provide a large acceptance for 100 MeV electrons and reach at these energies: (a) a time resolution better than 0.5 ns; (b) an energy resolution < 10% and (c) a position resolution of 1 cm. The calorimeter design consists of two disks, each one made of 674 undoped CsI crystals read by two large area arrays of UV-extended SiPMs. We report here the construction and test of the Module-0 prototype. The Module-0 has been exposed to an electron beam in the energy range around 100 MeV at the Beam Test Facility in Frascati. Preliminary results of timing and energy resolution at normal incidence are shown. A discussion of the technical aspects of the calorimeter engineering is also reported in this paper.
△ Less
Submitted 18 February, 2018;
originally announced February 2018.
-
The Mu2e Calorimeter Final Technical Design Report
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
S. Ceravolo,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
E. Dane,
Y. Davydov,
S. Di Falco,
S. Donati,
E. Diociaiuti,
R. Donghia,
B. Echenard,
K. Flood,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi
, et al. (15 additional authors not shown)
Abstract:
Since the first version of the Mu2e TDR released at the beginning of 2015, the Mu2e Calorimeter system has undergone a long list of changes to arrive to its final design. These changes were primarily caused by two reasons: (i) the technology choice between the TDR proposed solution of BaF2 crystals readout with solar blind Avalanche Photodiodes (APDs) and the backup option of CsI crystals readout…
▽ More
Since the first version of the Mu2e TDR released at the beginning of 2015, the Mu2e Calorimeter system has undergone a long list of changes to arrive to its final design. These changes were primarily caused by two reasons: (i) the technology choice between the TDR proposed solution of BaF2 crystals readout with solar blind Avalanche Photodiodes (APDs) and the backup option of CsI crystals readout with Silicon Photomultipliers (SiPM) has been completed and (ii) the channels numbering, the mechanical system and the readout electronics were substantially modified while proceeding with engineering towards the final project. This document updates the description of the calorimeter system adding the most recent engineering drawings and tecnical progresses.
△ Less
Submitted 18 February, 2018;
originally announced February 2018.
-
Expression of Interest for Evolution of the Mu2e Experiment
Authors:
F. Abusalma,
D. Ambrose,
A. Artikov,
R. Bernstein,
G. C. Blazey,
C. Bloise,
S. Boi,
T. Bolton,
J. Bono,
R. Bonventre,
D. Bowring,
D. Brown,
D. Brown,
K. Byrum,
M. Campbell,
J. -F. Caron,
F. Cervelli,
D. Chokheli,
K. Ciampa,
R. Ciolini,
R. Coleman,
D. Cronin-Hennessy,
R. Culbertson,
M. A. Cummings,
A. Daniel
, et al. (103 additional authors not shown)
Abstract:
We propose an evolution of the Mu2e experiment, called Mu2e-II, that would leverage advances in detector technology and utilize the increased proton intensity provided by the Fermilab PIP-II upgrade to improve the sensitivity for neutrinoless muon-to-electron conversion by one order of magnitude beyond the Mu2e experiment, providing the deepest probe of charged lepton flavor violation in the fores…
▽ More
We propose an evolution of the Mu2e experiment, called Mu2e-II, that would leverage advances in detector technology and utilize the increased proton intensity provided by the Fermilab PIP-II upgrade to improve the sensitivity for neutrinoless muon-to-electron conversion by one order of magnitude beyond the Mu2e experiment, providing the deepest probe of charged lepton flavor violation in the foreseeable future. Mu2e-II will use as much of the Mu2e infrastructure as possible, providing, where required, improvements to the Mu2e apparatus to accommodate the increased beam intensity and cope with the accompanying increase in backgrounds.
△ Less
Submitted 7 February, 2018;
originally announced February 2018.
-
The Mu2e crystal calorimeter
Authors:
N. Atanov,
J. Budagov,
F. Cervelli,
F. Colao,
Y Davidov,
S. Di Falco,
E. Diociaiuti,
S. Donati,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
P. Murat,
E. Pedreschi,
G. Pezzullo,
F. Porter,
A. Saputi,
I. Sarra,
F. Spinella,
G. Tassielli
Abstract:
The Mu2e Experiment at Fermilab will search for coherent, neutrino-less conversion of negative muons into electrons in the field of an Aluminum nucleus, $μ^- + Al \to e^- +Al$. Data collection start is planned for the end of 2021.
The dynamics of such charged lepton flavour violating (CLFV) process is well modelled by a two-body decay, resulting in a mono-energetic electron with an energy slight…
▽ More
The Mu2e Experiment at Fermilab will search for coherent, neutrino-less conversion of negative muons into electrons in the field of an Aluminum nucleus, $μ^- + Al \to e^- +Al$. Data collection start is planned for the end of 2021.
The dynamics of such charged lepton flavour violating (CLFV) process is well modelled by a two-body decay, resulting in a mono-energetic electron with an energy slightly below the muon rest mass. If no events are observed in three years of running, Mu2e will set an upper limit on the ratio between the conversion and the capture rates
%\convrate of $\leq 6\ \times\ 10^{-17}$ (@ 90$\%$ C.L.). R$_{μe} = \frac{μ^- + A(Z,N) \to e^- +A(Z,N)}{μ^- + A(Z,N) \to ν_μ ^- +A(Z-1,N)} $ of $\leq 6\ \times\ 10^{-17}$ (@ 90$\%$ C.L.).
This will improve the current limit of four order of magnitudes with respect to the previous best experiment.
Mu2e complements and extends the current search for $μ\to e γ$ decay at MEG as well as the direct searches for new physics at the LHC. The observation of such CLFV process could be clear evidence for New Physics beyond the Standard Model. Given its sensitivity, Mu2e will be able to probe New Physics at a scale inaccessible to direct searches at either present or planned high energy colliders. To search for the muon conversion process, a very intense pulsed beam of negative muons ($\sim 10^{10} μ/$ sec) is stopped on an Aluminum target inside a very long solenoid where the detector is also located. The Mu2e detector is composed of a straw tube tracker and a CsI crystals electromagnetic calorimeter. An overview of the physics motivations for Mu2e, the current status of the experiment and the required performances and design details of the calorimeter are presented.
△ Less
Submitted 30 January, 2018;
originally announced January 2018.
-
Design, status and perspective of the Mu2e crystal calorimeter
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
F. Cervelli,
F. Colao,
E. Diociaiuti,
M. Cordelli,
G. Corradi,
E. Danè,
Yu. Davydov,
S. Donati,
R. Donghia,
S. Di Falco,
B. Echenard,
L. Morescalchi,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
P. Murat
, et al. (11 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab will search for the charged lepton flavor violating process of neutrino-less $μ\to e$ coherent conversion in the field of an aluminum nucleus. Mu2e will reach a single event sensitivity of about $2.5\cdot 10^{-17}$ that corresponds to four orders of magnitude improvements with respect to the current best limit. The detector system consists of a straw tube tracker an…
▽ More
The Mu2e experiment at Fermilab will search for the charged lepton flavor violating process of neutrino-less $μ\to e$ coherent conversion in the field of an aluminum nucleus. Mu2e will reach a single event sensitivity of about $2.5\cdot 10^{-17}$ that corresponds to four orders of magnitude improvements with respect to the current best limit. The detector system consists of a straw tube tracker and a crystal calorimeter made of undoped CsI coupled with Silicon Photomultipliers. The calorimeter was designed to be operable in a harsh environment where about 10 krad/year will be delivered in the hottest region and work in presence of 1 T magnetic field. The calorimeter role is to perform $μ$/e separation to suppress cosmic muons mimiking the signal, while providing a high level trigger and a seeding the track search in the tracker. In this paper we present the calorimeter design and the latest R$\&$D results.
△ Less
Submitted 18 April, 2018; v1 submitted 9 January, 2018;
originally announced January 2018.
-
The Mu2e undoped CsI crystal calorimeter
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
Yu. I. Davydov,
S. Di Falco,
E. Diociaiuti,
S. Donati,
R. Donghia,
B. Echenard,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. G. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
P. Murat,
E. Pedreschi,
G. Pezzullo
, et al. (10 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigg…
▽ More
The Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigger filter; c) an easier tracker track reconstruction. Two disks, located downstream of the tracker, contain 674 pure CsI crystals each. Each crystal is read out by two arrays of UV-extended SiPMs. The choice of the crystals and SiPMs has been finalized after a thorough test campaign. A first small scale prototype consisting of 51 crystals and 102 SiPM arrays has been exposed to an electron beam at the BTF (Beam Test Facility) in Frascati. Although the readout electronics were not the final, results show that the current design is able to meet the timing and energy resolution required by the Mu2e experiment.
△ Less
Submitted 22 February, 2018; v1 submitted 7 January, 2018;
originally announced January 2018.
-
Pre-Production and Quality Assurance of the Mu2e Calorimeter Silicon Photomultipliers
Authors:
M. Cordelli,
F. Cervelli,
E. Diociaiuti,
S. Donati,
R. Donghia,
S. Di Falco,
A. Ferrari,
S. Giovannella,
F. Happacher,
M. Martini,
L. Morescalchi,
S. Miscetti,
S. Muller,
E. Pedreschi,
G. Pezzullo,
I. Sarra,
F. Spinella
Abstract:
The Mu2e electromagnetic calorimeter has to provide precise information on energy, time and position for $\sim$100 MeV electrons. It is composed of 1348 un-doped CsI crystals, each coupled to two large area Silicon Photomultipliers (SiPMs). A modular and custom SiPM layout consisting of a 3$\times$2 array of 6$\times$6 mm$^2$ UV-extended monolithic SiPMs has been developed to fulfill the Mu2e calo…
▽ More
The Mu2e electromagnetic calorimeter has to provide precise information on energy, time and position for $\sim$100 MeV electrons. It is composed of 1348 un-doped CsI crystals, each coupled to two large area Silicon Photomultipliers (SiPMs). A modular and custom SiPM layout consisting of a 3$\times$2 array of 6$\times$6 mm$^2$ UV-extended monolithic SiPMs has been developed to fulfill the Mu2e calorimeter requirements and a pre-production of 150 prototypes has been procured by three international firms (Hamamatsu, SensL and Advansid). A detailed quality assurance process has been carried out on this first batch of photosensors: the breakdown voltage, the gain, the quenching time, the dark current and the Photon Detection Efficiency (PDE) have been determined for each monolithic cell of each SiPMs array. One sample for each vendor has been exposed to a neutron fluency up to $\sim$8.5~$\times$~10$^{11}$ 1 MeV (Si) eq. n/cm$^{2}$ and a linear increase of the dark current up to tens of mA has been observed. Others 5 samples for each vendor have undergone an accelerated aging in order to verify a Mean Time To Failure (MTTF) higher than $\sim$10$^{6}$ hours.
△ Less
Submitted 13 December, 2017;
originally announced December 2017.
-
Quality Assurance on a custom SiPMs array for the Mu2e experiment
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
Yu. I. Davydov,
V. Glagolev,
V. Tereshchenko,
Z. Usubov,
F. Cervelli,
S. Di Falco,
S. Donati,
L. Morescalchi,
E. Pedreschi,
G. Pezzullo,
F. Raffaelli,
F. Spinella,
F. Colao,
M. Cordelli,
G. Corradi,
E. Diociaiuti,
R. Donghia,
S. Giovannella,
F. Happacher,
M. Martini,
S. Miscetti,
M. Ricci
, et al. (10 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab will search for the coherent $μ\to e$ conversion on aluminum atoms. The detector system consists of a straw tube tracker and a crystal calorimeter. A pre-production of 150 Silicon Photomultiplier arrays for the Mu2e calorimeter has been procured. A detailed quality assur- ance has been carried out on each SiPM for the determination of its own operation voltage, gain…
▽ More
The Mu2e experiment at Fermilab will search for the coherent $μ\to e$ conversion on aluminum atoms. The detector system consists of a straw tube tracker and a crystal calorimeter. A pre-production of 150 Silicon Photomultiplier arrays for the Mu2e calorimeter has been procured. A detailed quality assur- ance has been carried out on each SiPM for the determination of its own operation voltage, gain, dark current and PDE. The measurement of the mean-time-to-failure for a small random sample of the pro-production group has been also completed as well as the determination of the dark current increase as a function of the ioninizing and non-ioninizing dose.
△ Less
Submitted 20 November, 2017;
originally announced November 2017.
-
Components Qualification for a Possible use in the Mu2e Calorimeter Waveform Digitizers
Authors:
S. Di Falco,
S. Donati,
L. Morescalchi,
E. Pedreschi,
G. Pezzullo,
F. Spinella
Abstract:
The Mu2e experiment at Fermilab searches for the charged flavor violating conversion of a muon into an electron in the Coulomb field of a nucleus. The detector consists of a straw tube tracker and a CSI crystal electromagnetic calorimeter, both housed in a superconducting solenoid. Both the front-end and the digital electronics, located inside the cryostat, will be operated in vacuum under a 1 T m…
▽ More
The Mu2e experiment at Fermilab searches for the charged flavor violating conversion of a muon into an electron in the Coulomb field of a nucleus. The detector consists of a straw tube tracker and a CSI crystal electromagnetic calorimeter, both housed in a superconducting solenoid. Both the front-end and the digital electronics, located inside the cryostat, will be operated in vacuum under a 1 T magnetic field, having to sustain the high flux of neutrons and ionizing particles coming from the muons stop** target. These harsh experimental conditions make the design of the calorimeter waveform digitizer quite challenging. All the selected commercial devices must be tested individually and qualified for radiation hardness and operation in high magnetic field. At the moment the expected particles flux and spectra at the digitizers location are not completely simulated and we are using initial rough estimates to select the components for the first prototype. We are gaining experience in the qualification procedures using the selected components but the choice will be frozen only when dose and neutron flux simulations will be completed. The experimental results of the first qualification campaign are presented.
△ Less
Submitted 5 October, 2017;
originally announced October 2017.
-
The calorimeter of the Mu2e experiment at Fermilab
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
E. Dané,
Yu. I. Davydov,
S. Di Falco,
E. Diociaiuti,
S. Donati,
R. Donghia,
B. Echenard,
K. Flood,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. G. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
P. Murat
, et al. (12 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab looks for Charged Lepton Flavor Violation (CLFV) improving by 4 orders of magnitude the current experimental sensitivity for the muon to electron conversion in a muonic atom. A positive signal could not be explained in the framework of the current Standard Model of particle interactions and therefore would be a clear indication of new physics. In 3 years of data tak…
▽ More
The Mu2e experiment at Fermilab looks for Charged Lepton Flavor Violation (CLFV) improving by 4 orders of magnitude the current experimental sensitivity for the muon to electron conversion in a muonic atom. A positive signal could not be explained in the framework of the current Standard Model of particle interactions and therefore would be a clear indication of new physics. In 3 years of data taking, Mu2e is expected to observe less than one background event mimicking the electron coming from muon conversion. Achieving such a level of background suppression requires a deep knowledge of the experimental apparatus: a straw tube tracker, measuring the electron momentum and time, a cosmic ray veto system rejecting most of cosmic ray background and a pure CsI crystal calorimeter, that will measure time of flight, energy and impact position of the converted electron. The calorimeter has to operate in a harsh radiation environment, in a 10-4 Torr vacuum and inside a 1 T magnetic field. The results of the first qualification tests of the calorimeter components are reported together with the energy and time performances expected from the simulation and measured in beam tests of a small scale prototype.
△ Less
Submitted 27 January, 2017;
originally announced January 2017.
-
Design and status of the Mu2e electromagnetic calorimeter
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
R. Carosi,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
E. Dane',
Yu. I. Davydov,
S. Di Falco,
S. Donati,
R. Donghia,
B. Echenard,
K. Flood,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. G. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
P. Murat
, et al. (11 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab aims at measuring the neutrinoless conversion of a negative muon into an electron and reach a single event sensitivity of 2.5x10^{-17} after three years of data taking. The monoenergetic electron produced in the final state, is detected by a high precision tracker and a crystal calorimeter, all embedded in a large superconducting solenoid (SD) surrounded by a cosmic…
▽ More
The Mu2e experiment at Fermilab aims at measuring the neutrinoless conversion of a negative muon into an electron and reach a single event sensitivity of 2.5x10^{-17} after three years of data taking. The monoenergetic electron produced in the final state, is detected by a high precision tracker and a crystal calorimeter, all embedded in a large superconducting solenoid (SD) surrounded by a cosmic ray veto system. The calorimeter is complementary to the tracker, allowing an independent trigger and powerful particle identification, while seeding the track reconstruction and contributing to remove background tracks mimicking the signal. In order to match these requirements, the calorimeter should have an energy resolution of O(5)% and a time resolution better than 500 ps at 100 MeV. The baseline solution is a calorimeter composed of two disks of BaF2 crystals read by UV extended, solar blind, Avalanche Photodiode (APDs), which are under development from a JPL, Caltech, RMD consortium. In this paper, the calorimeter design, the R&D studies carried out so far and the status of engineering are described. A backup alternative setup consisting of a pure CsI crystal matrix read by UV extended Hamamatsu MPPC's is also presented.
△ Less
Submitted 8 August, 2016;
originally announced August 2016.
-
Design, status and test of the Mu2e crystal calorimeter
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
R. Carosi,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
E. Danè,
Y. I. Davydov,
S. Di Falco,
S. Donati,
R. Donghia,
B. Echenard,
K. Flood,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. G. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
P. Murat
, et al. (11 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab searches for the charged-lepton flavor violating neutrino-less conversion of a negative muon into an electron in the field of a aluminum nucleus. The dynamic of such a process is well modeled by a two-body decay, resulting in a monoenergetic electron with an energy slightly below the muon rest mass (104.967 MeV). The calorimeter of this experiment plays an important…
▽ More
The Mu2e experiment at Fermilab searches for the charged-lepton flavor violating neutrino-less conversion of a negative muon into an electron in the field of a aluminum nucleus. The dynamic of such a process is well modeled by a two-body decay, resulting in a monoenergetic electron with an energy slightly below the muon rest mass (104.967 MeV). The calorimeter of this experiment plays an important role to provide excellent particle identification capabilities and an online trigger filter while aiding the track reconstruction capabilities. The baseline calorimeter configuration consists of two disks each made with about 700 undoped CsI crystals read out by two large area UV-extended Silicon Photomultipliers. These crystals match the requirements for stability of response, high resolution and radiation hardness. In this paper we present the final calorimeter design.
△ Less
Submitted 1 July, 2016; v1 submitted 17 June, 2016;
originally announced June 2016.
-
Mu2e Technical Design Report
Authors:
L. Bartoszek,
E. Barnes,
J. P. Miller,
J. Mott,
A. Palladino,
J. Quirk,
B. L. Roberts,
J. Crnkovic,
V. Polychronakos,
V. Tishchenko,
P. Yamin,
C. -h. Cheng,
B. Echenard,
K. Flood,
D. G. Hitlin,
J. H. Kim,
T. S. Miyashita,
F. C. Porter,
M. Röhrken,
J. Trevor,
R. -Y. Zhu,
E. Heckmaier,
T. I. Kang,
G. Lim,
W. Molzon
, et al. (238 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the L…
▽ More
The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe herein the preliminary design of the proposed Mu2e experiment. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2 approval.
△ Less
Submitted 16 March, 2015; v1 submitted 21 January, 2015;
originally announced January 2015.
-
The artificial retina for track reconstruction at the LHC crossing rate
Authors:
A. Abba,
F. Bedeschi,
M. Citterio,
F. Caponio,
A. Cusimano,
A. Geraci,
P. Marino,
M. J. Morello,
N. Neri,
G. Punzi,
A. Piucci,
L. Ristori,
F. Spinella,
S. Stracka,
D. Tonelli
Abstract:
We present the results of an R&D study for a specialized processor capable of precisely reconstructing events with hundreds of charged-particle tracks in pixel and silicon strip detectors at $40\,\rm MHz$, thus suitable for processing LHC events at the full crossing frequency. For this purpose we design and test a massively parallel pattern-recognition algorithm, inspired to the current understand…
▽ More
We present the results of an R&D study for a specialized processor capable of precisely reconstructing events with hundreds of charged-particle tracks in pixel and silicon strip detectors at $40\,\rm MHz$, thus suitable for processing LHC events at the full crossing frequency. For this purpose we design and test a massively parallel pattern-recognition algorithm, inspired to the current understanding of the mechanisms adopted by the primary visual cortex of mammals in the early stages of visual-information processing. The detailed geometry and charged-particle's activity of a large tracking detector are simulated and used to assess the performance of the artificial retina algorithm. We find that high-quality tracking in large detectors is possible with sub-microsecond latencies when the algorithm is implemented in modern, high-speed, high-bandwidth FPGA devices.
△ Less
Submitted 5 November, 2014;
originally announced November 2014.
-
First prototype of a silicon tracker using an artificial retina for fast track finding
Authors:
N. Neri,
A. Abba,
F. Caponio,
M. Citterio,
S. Coelli,
J. Fu,
A. Geraci,
M. Monti,
M. Petruzzo,
F. Bedeschi,
P. Marino,
M. J. Morello,
A. Piucci,
G. Punzi,
F. Spinella,
S. Stracka,
J. Walsh,
L. Ristori,
D. Tonelli
Abstract:
We report on the R\&D for a first prototype of a silicon tracker based on an alternative approach for fast track finding. The working principle is inspired from neurobiology, in particular by the processing of visual images by the brain as it happens in nature. It is based on extensive parallelisation of data distribution and pattern recognition. In this work we present the design of a practical d…
▽ More
We report on the R\&D for a first prototype of a silicon tracker based on an alternative approach for fast track finding. The working principle is inspired from neurobiology, in particular by the processing of visual images by the brain as it happens in nature. It is based on extensive parallelisation of data distribution and pattern recognition. In this work we present the design of a practical device that consists of a telescope based on single-sided silicon detectors; we describe the data acquisition system and the implementation of the track finding algorithms using available digital logic of commercial FPGA devices. Tracking performance and trigger capabilities of the device are discussed along with perspectives for future applications.
△ Less
Submitted 11 September, 2014;
originally announced September 2014.
-
The artificial retina processor for track reconstruction at the LHC crossing rate
Authors:
A. Abba,
F. Bedeschi,
M. Citterio,
F. Caponio,
A. Cusimano,
A. Geraci,
P. Marino,
M. J. Morello,
N. Neri,
G. Punzi,
A. Piucci,
L. Ristori,
F. Spinella,
S. Stracka,
D. Tonelli
Abstract:
We present results of an R&D study for a specialized processor capable of precisely reconstructing, in pixel detectors, hundreds of charged-particle tracks from high-energy collisions at 40 MHz rate. We apply a highly parallel pattern-recognition algorithm, inspired by studies of the processing of visual images by the brain as it happens in nature, and describe in detail an efficient hardware impl…
▽ More
We present results of an R&D study for a specialized processor capable of precisely reconstructing, in pixel detectors, hundreds of charged-particle tracks from high-energy collisions at 40 MHz rate. We apply a highly parallel pattern-recognition algorithm, inspired by studies of the processing of visual images by the brain as it happens in nature, and describe in detail an efficient hardware implementation in high-speed, high-bandwidth FPGA devices. This is the first detailed demonstration of reconstruction of offline-quality tracks at 40 MHz and makes the device suitable for processing Large Hadron Collider events at the full crossing frequency.
△ Less
Submitted 4 December, 2014; v1 submitted 4 September, 2014;
originally announced September 2014.
-
Simulation and performance of an artificial retina for 40 MHz track reconstruction
Authors:
A. Abba,
F. Bedeschi,
M. Citterio,
F. Caponio,
A. Cusimano,
A. Geraci,
P. Marino,
M. J. Morello,
N. Neri,
G. Punzi,
A. Piucci,
L. Ristori,
F. Spinella,
S. Stracka,
D. Tonelli
Abstract:
We present the results of a detailed simulation of the artificial retina pattern-recognition algorithm, designed to reconstruct events with hundreds of charged-particle tracks in pixel and silicon detectors at LHCb with LHC crossing frequency of $40\,\rm MHz$. Performances of the artificial retina algorithm are assessed using the official Monte Carlo samples of the LHCb experiment. We found perfor…
▽ More
We present the results of a detailed simulation of the artificial retina pattern-recognition algorithm, designed to reconstruct events with hundreds of charged-particle tracks in pixel and silicon detectors at LHCb with LHC crossing frequency of $40\,\rm MHz$. Performances of the artificial retina algorithm are assessed using the official Monte Carlo samples of the LHCb experiment. We found performances for the retina pattern-recognition algorithm comparable with the full LHCb reconstruction algorithm.
△ Less
Submitted 12 March, 2015; v1 submitted 2 September, 2014;
originally announced September 2014.
-
A high-resolution TDC-based board for a fully digital trigger and data acquisition system in the NA62 experiment at CERN
Authors:
Elena Pedreschi,
Bruno Angelucci,
Carlo Avanzini,
Stefano Galeotti,
Gianluca Lamanna,
Guido Magazzu,
Jacopo Pinzino,
Roberto Piandani,
Marco Sozzi,
Franco Spinella,
Stefano Venditti
Abstract:
A Time to Digital Converter (TDC) based system, to be used for most sub-detectors in the high-flux rare-decay experiment NA62 at CERN SPS, was built as part of the NA62 fully digital Trigger and Data AcQuisition system (TDAQ), in which the TDC Board (TDCB) and a general-purpose motherboard (TEL62) will play a fundamental role. While TDCBs, housing four High Performance Time to Digital Converters (…
▽ More
A Time to Digital Converter (TDC) based system, to be used for most sub-detectors in the high-flux rare-decay experiment NA62 at CERN SPS, was built as part of the NA62 fully digital Trigger and Data AcQuisition system (TDAQ), in which the TDC Board (TDCB) and a general-purpose motherboard (TEL62) will play a fundamental role. While TDCBs, housing four High Performance Time to Digital Converters (HPTDC), measure hit times from sub-detectors, the motherboard processes and stores them in a buffer, produces trigger primitives from different detectors and extracts only data related to the lowest trigger level decision, once this is taken on the basis of the trigger primitives themselves. The features of the TDCB board developed by the Pisa NA62 group are extensively discussed and performance data is presented in order to show its compliance with the experiment requirements.
△ Less
Submitted 9 July, 2014;
originally announced July 2014.
-
A Specialized Processor for Track Reconstruction at the LHC Crossing Rate
Authors:
A. Abba,
F. Bedeschi,
M. Citterio,
F. Caponio,
A. Cusimano,
A. Geraci,
P. Marino,
M. J. Morello,
N. Neri,
G. Punzi,
A. Piucci,
L. Ristori,
F. Spinella,
S. Stracka,
D. Tonelli
Abstract:
We present the results of an R&D study of a specialized processor capable of precisely reconstructing events with hundreds of charged-particle tracks in pixel detectors at 40 MHz, thus suitable for processing LHC events at the full crossing frequency. For this purpose we design and test a massively parallel pattern-recognition algorithm, inspired by studies of the processing of visual images by th…
▽ More
We present the results of an R&D study of a specialized processor capable of precisely reconstructing events with hundreds of charged-particle tracks in pixel detectors at 40 MHz, thus suitable for processing LHC events at the full crossing frequency. For this purpose we design and test a massively parallel pattern-recognition algorithm, inspired by studies of the processing of visual images by the brain as it happens in nature. We find that high-quality tracking in large detectors is possible with sub-$μ$s latencies when this algorithm is implemented in modern, high-speed, high-bandwidth FPGA devices. This opens a possibility of making track reconstruction happen transparently as part of the detector readout.
△ Less
Submitted 27 June, 2014;
originally announced June 2014.
-
Performance of the TOTEM Detectors at the LHC
Authors:
TOTEM Collaboration,
G. Antchev,
P. Aspell,
I. Atanassov,
V. Avati,
J. Baechler,
M. G. Bagliesi,
V. Berardi,
M. Berretti,
E. Bossini,
U. Bottigli,
M. Bozzo,
E. Brücken,
A. Buzzo,
F. S. Cafagna,
M. G. Catanesi,
R. Cecchi,
C. Covault,
M. Csanád,
T. Csörgő,
M. Deile,
M. Doubek,
K. Eggert,
V. Eremin,
F. Ferro
, et al. (57 additional authors not shown)
Abstract:
The TOTEM Experiment is designed to measure the total proton-proton cross-section with the luminosity-independent method and to study elastic and diffractive pp scattering at the LHC. To achieve optimum forward coverage for charged particles emitted by the pp collisions in the interaction point IP5, two tracking telescopes, T1 and T2, are installed on each side of the IP in the pseudorapidity regi…
▽ More
The TOTEM Experiment is designed to measure the total proton-proton cross-section with the luminosity-independent method and to study elastic and diffractive pp scattering at the LHC. To achieve optimum forward coverage for charged particles emitted by the pp collisions in the interaction point IP5, two tracking telescopes, T1 and T2, are installed on each side of the IP in the pseudorapidity region 3.1 < = |eta | < = 6.5, and special movable beam-pipe insertions - called Roman Pots (RP) - are placed at distances of +- 147 m and +- 220 m from IP5. This article describes in detail the working of the TOTEM detector to produce physics results in the first three years of operation and data taking at the LHC.
△ Less
Submitted 10 October, 2013;
originally announced October 2013.