-
HAITCH: A Framework for Distortion and Motion Correction in Fetal Multi-Shell Diffusion-Weighted MRI
Authors:
Haykel Snoussi,
Davood Karimi,
Onur Afacan,
Mustafa Utkur,
Ali Gholipour
Abstract:
Diffusion magnetic resonance imaging (dMRI) is pivotal for probing the microstructure of the rapidly-develo** fetal brain. However, fetal motion during scans and its interaction with magnetic field inhomogeneities result in artifacts and data scattering across spatial and angular domains. The effects of those artifacts are more pronounced in high-angular resolution fetal dMRI, where signal-to-no…
▽ More
Diffusion magnetic resonance imaging (dMRI) is pivotal for probing the microstructure of the rapidly-develo** fetal brain. However, fetal motion during scans and its interaction with magnetic field inhomogeneities result in artifacts and data scattering across spatial and angular domains. The effects of those artifacts are more pronounced in high-angular resolution fetal dMRI, where signal-to-noise ratio is very low. Those effects lead to biased estimates and compromise the consistency and reliability of dMRI analysis. This work presents HAITCH, the first and the only publicly available tool to correct and reconstruct multi-shell high-angular resolution fetal dMRI data. HAITCH offers several technical advances that include a blip-reversed dual-echo acquisition for dynamic distortion correction, advanced motion correction for model-free and robust reconstruction, optimized multi-shell design for enhanced information capture and increased tolerance to motion, and outlier detection for improved reconstruction fidelity. The framework is open-source, flexible, and can be used to process any type of fetal dMRI data including single-echo or single-shell acquisitions, but is most effective when used with multi-shell multi-echo fetal dMRI data that cannot be processed with any of the existing tools. Validation experiments on real fetal dMRI scans demonstrate significant improvements and accurate correction across diverse fetal ages and motion levels. HAITCH successfully removes artifacts and reconstructs high-fidelity fetal dMRI data suitable for advanced diffusion modeling, including fiber orientation distribution function estimation. These advancements pave the way for more reliable analysis of the fetal brain microstructure and tractography under challenging imaging conditions.
△ Less
Submitted 28 June, 2024;
originally announced June 2024.
-
Effectiveness of regional diffusion MRI measures in distinguishing multiple sclerosis abnormalities within the cervical spinal cord
Authors:
Haykel Snoussi,
Julien Cohen-Adad,
Benoit Combes,
Elise Bannier,
Slimane Tounekti,
Anne Kerbrat,
Christian Barillot,
Emmanuel Caruyer
Abstract:
Multiple sclerosis is an inflammatory disorder of the central nervous system. Quantitative MRI has huge potential to provide intrinsic and normative values of tissue properties useful for diagnosis, prognosis and ultimately clinical follow-up of this disease. However, there is a large discrepancy between the clinical observations and how the pathology is exhibited in MRI brain scans. Complementary…
▽ More
Multiple sclerosis is an inflammatory disorder of the central nervous system. Quantitative MRI has huge potential to provide intrinsic and normative values of tissue properties useful for diagnosis, prognosis and ultimately clinical follow-up of this disease. However, there is a large discrepancy between the clinical observations and how the pathology is exhibited in MRI brain scans. Complementary to brain imaging, the study of multiple sclerosis lesions in the spinal cord has recently gained interest as a potential marker for early physical impairment. Therefore, investigating how the spinal cord is damaged using quantitative imaging, in particular, diffusion MRI, becomes an acute challenge. In this work, we extract average diffusion MRI metrics per vertebral level from spinal cord data acquired from multiple clinical sites. The diffusion-based metrics involved are extracted from the diffusion tensor imaging and Ball-and-Stick models and quantified for every cervical vertebral level using a collection of image processing methods and an atlas-based approach. Then, we perform a statistical analysis study to characterize the feasibility of these metrics to detect lesions. Specifically, we study the usefulness of combining different metrics to improve the accuracy prediction score associated with the presence of multiple sclerosis lesions. We demonstrate the grade of sensitivity to underlying microstructure changes in MS patients of each metric. Ball-and-Stick provides novel information about the MS damage to tissue microstructure. In addition, we show that choosing a subset of metrics: [FA, RD, MD] and [FWW, MD, Stick-AD, RD], which bring complementary information, has significantly increased the prediction score of the presence of the MS lesion in the cervical spinal cord.
△ Less
Submitted 1 August, 2023; v1 submitted 9 August, 2021;
originally announced August 2021.
-
Evaluation of distortion correction methods in diffusion MRI of the spinal cord
Authors:
Haykel Snoussi,
Julien Cohen-Adad,
Olivier Commowick,
Benoit Combes,
Elise Bannier,
Soizic Leguy,
Anne Kerbrat,
Christian Barillot,
Emmanuel Caruyer
Abstract:
Background: Magnetic field inhomogeneities generate important geometric distortions in reconstructed echo-planar images. Various procedures were proposed for correcting these distortions on brain images; yet, few neuroimaging studies tailored and incorporated the use of these techniques in spinal cord diffusion MRI. Purpose: We present a comparative evaluation of distortion correction methods that…
▽ More
Background: Magnetic field inhomogeneities generate important geometric distortions in reconstructed echo-planar images. Various procedures were proposed for correcting these distortions on brain images; yet, few neuroimaging studies tailored and incorporated the use of these techniques in spinal cord diffusion MRI. Purpose: We present a comparative evaluation of distortion correction methods that use the reversed gradient polarity technique on spinal cord. We propose novel geometric metrics to measure the alignment of the reconstructed diffusion model with the apparent centerline of the spinal cord. Subjects: 95 subjects, among which 29 healthy controls and 66 multiple sclerosis patients. Assessment: Geometric distortions were corrected using 4 state-of-the-art methods. We measured the alignment of the principal direction of diffusion with the apparent centerline of the spine after correction and the correlation with the reference anatomical image. Results are computed per vertebral level, to evaluate the impact on different portions of the spine. Besides, subjective evaluation of the quality of the correction of healthy subjects images was performed by three expert raters. Results: As a result of distortion correction, the diffusion directions are better aligned locally with the centerline, in particular at both ends of the acquisition window. The cross-correlation with anatomical image is also improved by Hyperelastic Susceptibility Artefact Correction (HySCO) and block-matching. The subjective evaluation for HySCO is significantly better (p < 0.05) than for Block-Matching; TOPUP performs significantly worse than the three other methods. Conclusion: Correction based on HySCO provide best results among the selected methods.
△ Less
Submitted 9 August, 2021;
originally announced August 2021.
-
Reproducibility and Evolution of Diffusion MRI Measurements within the Cervical Spinal Cord in Multiple Sclerosis
Authors:
Haykel Snoussi,
Emmanuel Caruyer,
Benoit Combes,
Olivier Commowick,
Elise Bannier,
Anne Kerbrat,
Julien Cohen-Adad,
Christian Barillot
Abstract:
In Multiple Sclerosis (MS), there is a large discrepancy between the clinical observations and how the pathology is exhibited on brain images, this is known as the clinical-radiological paradox (CRP). One of the hypotheses is that the clinical deficit may be more related to the spinal cord damage than the number or location of lesions in the brain. Therefore, investigating how the spinal cord is d…
▽ More
In Multiple Sclerosis (MS), there is a large discrepancy between the clinical observations and how the pathology is exhibited on brain images, this is known as the clinical-radiological paradox (CRP). One of the hypotheses is that the clinical deficit may be more related to the spinal cord damage than the number or location of lesions in the brain. Therefore, investigating how the spinal cord is damaged becomes an acute challenge to better understand and overcome the CRP. Diffusion MRI is known to provide quantitative figures of neuronal degeneration and axonal loss, in the brain as well as in the spinal cord. In this paper, we propose to investigate how diffusion MRI metrics vary in the different cervical regions with the progression of the disease. We first study the reproducibility of diffusion MRI on healthy volunteers with a test-retest procedure using both standard diffusion tensor imaging (DTI) and multi-compartment Ball-and-Stick models. Then, based on the test re-test quantitative calibration, we provide quantitative figures of pathology evolution between M0 and M12 in the cervical spine on a set of 31 MS patients, exhibiting how the pathology damage spans in the cervical spinal cord.
△ Less
Submitted 8 August, 2021;
originally announced August 2021.
-
MCMC joint separation and segmentation of hidden Markov fields
Authors:
Hichem Snoussi,
Ali Mohammad-Djafari
Abstract:
In this contribution, we consider the problem of the blind separation of noisy instantaneously mixed images. The images are modelized by hidden Markov fields with unknown parameters. Given the observed images, we give a Bayesian formulation and we propose to solve the resulting data augmentation problem by implementing a Monte Carlo Markov Chain (MCMC) procedure. We separate the unknown variable…
▽ More
In this contribution, we consider the problem of the blind separation of noisy instantaneously mixed images. The images are modelized by hidden Markov fields with unknown parameters. Given the observed images, we give a Bayesian formulation and we propose to solve the resulting data augmentation problem by implementing a Monte Carlo Markov Chain (MCMC) procedure. We separate the unknown variables into two categories:
1. The parameters of interest which are the mixing matrix, the noise covariance and the parameters of the sources distributions. 2. The hidden variables which are the unobserved sources and the unobserved pixels classification labels.
The proposed algorithm provides in the stationary regime samples drawn from the posterior distributions of all the variables involved in the problem leading to a flexibility in the cost function choice.
We discuss and characterize some problems of non identifiability and degeneracies of the parameters likelihood and the behavior of the MCMC algorithm in this case.
Finally, we show the results for both synthetic and real data to illustrate the feasibility of the proposed solution. keywords: MCMC, blind source separation, hidden Markov fields, segmentation, Bayesian approach
△ Less
Submitted 12 November, 2002;
originally announced November 2002.
-
Bayesian source separation with mixture of Gaussians prior for sources and Gaussian prior for mixture coefficients
Authors:
Hichem Snoussi,
Ali Mohammad-Djafari
Abstract:
In this contribution, we present new algorithms to source separation for the case of noisy instantaneous linear mixture, within the Bayesian statistical framework. The source distribution prior is modeled by a mixture of Gaussians [Moulines97] and the mixing matrix elements distributions by a Gaussian [Djafari99a]. We model the mixture of Gaussians hierarchically by mean of hidden variables repr…
▽ More
In this contribution, we present new algorithms to source separation for the case of noisy instantaneous linear mixture, within the Bayesian statistical framework. The source distribution prior is modeled by a mixture of Gaussians [Moulines97] and the mixing matrix elements distributions by a Gaussian [Djafari99a]. We model the mixture of Gaussians hierarchically by mean of hidden variables representing the labels of the mixture. Then, we consider the joint a posteriori distribution of sources, mixing matrix elements, labels of the mixture and other parameters of the mixture with appropriate prior probability laws to eliminate degeneracy of the likelihood function of variance parameters and we propose two iterative algorithms to estimate jointly sources, mixing matrix and hyperparameters: Joint MAP (Maximum a posteriori) algorithm and penalized EM algorithm. The illustrative example is taken in [Macchi99] to compare with other algorithms proposed in literature. Keywords: Source separation, Gaussian mixture, classification, JMAP algorithm, Penalized EM algorithm.
△ Less
Submitted 6 November, 2001;
originally announced November 2001.
-
Penalized maximum likelihood for multivariate Gaussian mixture
Authors:
Hichem Snoussi,
Ali Mohammad-Djafari
Abstract:
In this paper, we first consider the parameter estimation of a multivariate random process distribution using multivariate Gaussian mixture law. The labels of the mixture are allowed to have a general probability law which gives the possibility to modelize a temporal structure of the process under study. We generalize the case of univariate Gaussian mixture in [Ridolfi99] to show that the likeli…
▽ More
In this paper, we first consider the parameter estimation of a multivariate random process distribution using multivariate Gaussian mixture law. The labels of the mixture are allowed to have a general probability law which gives the possibility to modelize a temporal structure of the process under study. We generalize the case of univariate Gaussian mixture in [Ridolfi99] to show that the likelihood is unbounded and goes to infinity when one of the covariance matrices approaches the boundary of singularity of the non negative definite matrices set. We characterize the parameter set of these singularities. As a solution to this degeneracy problem, we show that the penalization of the likelihood by an Inverse Wishart prior on covariance matrices results to a penalized or maximum a posteriori criterion which is bounded. Then, the existence of positive definite matrices optimizing this criterion can be guaranteed. We also show that with a modified EM procedure or with a Bayesian sampling scheme, we can constrain covariance matrices to belong to a particular subclass of covariance matrices. Finally, we study degeneracies in the source separation problem where the characterization of parameter singularity set is more complex. We show, however, that Inverse Wishart prior on covariance matrices eliminates the degeneracies in this case too.
△ Less
Submitted 2 November, 2001;
originally announced November 2001.