-
Roadmap on Deep Learning for Microscopy
Authors:
Giovanni Volpe,
Carolina Wählby,
Lei Tian,
Michael Hecht,
Artur Yakimovich,
Kristina Monakhova,
Laura Waller,
Ivo F. Sbalzarini,
Christopher A. Metzler,
Mingyang Xie,
Kevin Zhang,
Isaac C. D. Lenton,
Halina Rubinsztein-Dunlop,
Daniel Brunner,
Bijie Bai,
Aydogan Ozcan,
Daniel Midtvedt,
Hao Wang,
Nataša Sladoje,
Joakim Lindblad,
Jason T. Smith,
Marien Ochoa,
Margarida Barroso,
Xavier Intes,
Tong Qiu
, et al. (50 additional authors not shown)
Abstract:
Through digital imaging, microscopy has evolved from primarily being a means for visual observation of life at the micro- and nano-scale, to a quantitative tool with ever-increasing resolution and throughput. Artificial intelligence, deep neural networks, and machine learning are all niche terms describing computational methods that have gained a pivotal role in microscopy-based research over the…
▽ More
Through digital imaging, microscopy has evolved from primarily being a means for visual observation of life at the micro- and nano-scale, to a quantitative tool with ever-increasing resolution and throughput. Artificial intelligence, deep neural networks, and machine learning are all niche terms describing computational methods that have gained a pivotal role in microscopy-based research over the past decade. This Roadmap is written collectively by prominent researchers and encompasses selected aspects of how machine learning is applied to microscopy image data, with the aim of gaining scientific knowledge by improved image quality, automated detection, segmentation, classification and tracking of objects, and efficient merging of information from multiple imaging modalities. We aim to give the reader an overview of the key developments and an understanding of possibilities and limitations of machine learning for microscopy. It will be of interest to a wide cross-disciplinary audience in the physical sciences and life sciences.
△ Less
Submitted 7 March, 2023;
originally announced March 2023.
-
Precision Measurement of the Specific Activity of $^{39}$Ar in Atmospheric Argon with the DEAP-3600 Detector
Authors:
P. Adhikari,
R. Ajaj,
M. Alpízar-Venegas,
P. -A. Amaudruz,
J. Anstey,
G. R. Araujo,
D. J. Auty,
M. Baldwin,
M. Batygov,
B. Beltran,
H. Benmansour,
C. E. Bina,
J. Bonatt,
W. Bonivento,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
M. Cadeddu,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
M. Chen,
Y. Chen
, et al. (125 additional authors not shown)
Abstract:
The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoi…
▽ More
The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoils and is well-suited to measure the decay of $^{39}$Ar. With 167 live-days of data, the measured specific activity at the time of atmospheric extraction is [0.964 $\pm$ 0.001 (stat) $\pm$ 0.024 (sys)] Bq/kg$_{\rm atmAr}$ which is consistent with results from other experiments. A cross-check analysis using different event selection criteria provides a consistent result.
△ Less
Submitted 10 October, 2023; v1 submitted 27 February, 2023;
originally announced February 2023.
-
Deep learning in biomedical optics
Authors:
Lei Tian,
Brady Hunt,
Muyinatu A. Lediju Bell,
Ji Yi,
Jason T. Smith,
Marien Ochoa,
Xavier Intes,
Nicholas J. Durr
Abstract:
This article reviews deep learning applications in biomedical optics with a particular emphasis on image formation. The review is organized by imaging domains within biomedical optics and includes microscopy, fluorescence lifetime imaging, in vivo microscopy, widefield endoscopy, optical coherence tomography, photoacoustic imaging, diffuse tomography, and functional optical brain imaging. For each…
▽ More
This article reviews deep learning applications in biomedical optics with a particular emphasis on image formation. The review is organized by imaging domains within biomedical optics and includes microscopy, fluorescence lifetime imaging, in vivo microscopy, widefield endoscopy, optical coherence tomography, photoacoustic imaging, diffuse tomography, and functional optical brain imaging. For each of these domains, we summarize how deep learning has been applied and highlight methods by which deep learning can enable new capabilities for optics in medicine. Challenges and opportunities to improve translation and adoption of deep learning in biomedical optics are also summarized.
△ Less
Submitted 23 May, 2021;
originally announced May 2021.
-
Pulseshape discrimination against low-energy Ar-39 beta decays in liquid argon with 4.5 tonne-years of DEAP-3600 data
Authors:
The DEAP Collaboration,
P. Adhikari,
R. Ajaj,
M. Alpízar-Venegas,
P. -A. Amaudruz,
D. J. Auty,
M. Batygov,
B. Beltran,
H. Benmansour,
C. E. Bina,
J. Bonatt,
W. Bonivento,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
M. Cadeddu,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
M. Chen,
Y. Chen,
B. T. Cleveland,
J. M. Corning
, et al. (104 additional authors not shown)
Abstract:
The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from $^{39}$Ar beta decays and is suppressed using pulseshape discrimination (PSD).
We use two types of PSD algorithm: the prompt-fraction, which considers the fraction of the scintillation signal in a narrow and a wide time window ar…
▽ More
The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from $^{39}$Ar beta decays and is suppressed using pulseshape discrimination (PSD).
We use two types of PSD algorithm: the prompt-fraction, which considers the fraction of the scintillation signal in a narrow and a wide time window around the event peak, and the log-likelihood-ratio, which compares the observed photon arrival times to a signal and a background model. We furthermore use two algorithms to determine the number of photons detected at a given time: (1) simply dividing the charge of each PMT pulse by the charge of a single photoelectron, and (2) a likelihood analysis that considers the probability to detect a certain number of photons at a given time, based on a model for the scintillation pulseshape and for afterpulsing in the light detectors.
The prompt-fraction performs approximately as well as the log-likelihood-ratio PSD algorithm if the photon detection times are not biased by detector effects. We explain this result using a model for the information carried by scintillation photons as a function of the time when they are detected.
△ Less
Submitted 6 April, 2021; v1 submitted 22 March, 2021;
originally announced March 2021.
-
Mechanical Ventilator Milano (MVM): A Novel Mechanical Ventilator Designed for Mass Scale Production in Response to the COVID-19 Pandemic
Authors:
C. Galbiati,
A. Abba,
P. Agnes,
P. Amaudruz,
M. Arba,
F. Ardellier-Desages,
C. Badia,
G. Batignani,
G. Bellani,
G. Bianchi,
D. Bishop,
V. Bocci,
W. Bonivento,
B. Bottino,
M. Bouchard,
S. Brice,
G. Buccino,
S. Bussino,
A. Caminata,
A. Capra,
M. Caravati,
M. Carlini,
L. Carrozzi,
J. M. Cela,
B. Celano
, et al. (123 additional authors not shown)
Abstract:
Presented here is the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for rapid mass production in response to the COVID-19 pandemic to address the urgent shortage of intensive therapy ventilators in many countries, and the growing difficulty in procuring these devices through normal supply chains across borders. This ventilator is an electro-mechanical equ…
▽ More
Presented here is the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for rapid mass production in response to the COVID-19 pandemic to address the urgent shortage of intensive therapy ventilators in many countries, and the growing difficulty in procuring these devices through normal supply chains across borders. This ventilator is an electro-mechanical equivalent of the old and reliable Manley Ventilator, and is able to operate in both pressure-controlled and pressure-supported ventilation modes. MVM is optimized for the COVID-19 emergency, thanks to the collaboration with medical doctors in the front line. MVM is designed for large-scale production in a short amount of time and at a limited cost, as it relays on off-the-shelf components, readily available worldwide. Operation of the MVM requires only a source of compressed oxygen (or compressed medical air) and electrical power. Initial tests of a prototype device with a breathing simulator are also presented. Further tests and developments are underway. At this stage the MVM is not yet a certified medical device but certification is in progress.
△ Less
Submitted 10 April, 2020; v1 submitted 23 March, 2020;
originally announced March 2020.
-
The liquid-argon scintillation pulseshape in DEAP-3600
Authors:
The DEAP collaboration,
P. Adhikari,
R. Ajaj,
G. R. Araujoand M. Batygov,
B. Beltran,
C. E. Bina,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
A. Butcher,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
Y. Chen,
B. T. Cleveland,
J. M. Corning,
S. J. Daughertyand K. Dering,
L. Doria,
F. A. Duncan andM. Dunford,
A. Erlandson,
N. Fatemighomi,
G. Fiorillo,
A. Flower,
R. J. Ford,
R. Gagnon
, et al. (76 additional authors not shown)
Abstract:
DEAP-3600 is a liquid-argon scintillation detector looking for dark matter. Scintillation events in the liquid argon (LAr) are registered by 255 photomultiplier tubes (PMTs), and pulseshape discrimination (PSD) is used to suppress electromagnetic background events. The excellent PSD performance of LAr makes it a viable target for dark matter searches, and the LAr scintillation pulseshape discussed…
▽ More
DEAP-3600 is a liquid-argon scintillation detector looking for dark matter. Scintillation events in the liquid argon (LAr) are registered by 255 photomultiplier tubes (PMTs), and pulseshape discrimination (PSD) is used to suppress electromagnetic background events. The excellent PSD performance of LAr makes it a viable target for dark matter searches, and the LAr scintillation pulseshape discussed here is the basis of PSD.
The observed pulseshape is a combination of LAr scintillation physics with detector effects. We present a model for the pulseshape of electromagnetic background events in the energy region of interest for dark matter searches. The model is composed of a) LAr scintillation physics, including the so-called intermediate component, b) the time response of the TPB wavelength shifter, including delayed TPB emission at $\mathcal O$(ms) time-scales, and c) PMT response.
TPB is the wavelength shifter of choice in most LAr detectors. We find that approximately 10\% of the intensity of the wavelength-shifted light is in a long-lived state of TPB. This causes light from an event to spill into subsequent events to an extent not usually accounted for in the design and data analysis of LAr-based detectors.
△ Less
Submitted 8 June, 2020; v1 submitted 27 January, 2020;
originally announced January 2020.
-
In-situ characterization of the Hamamatsu R5912-HQE photomultiplier tubes used in the DEAP-3600 experiment
Authors:
DEAP Collaboration,
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
C. E. Bina,
D. Bishop,
J. Bonatt,
G. Boorman,
M. G. Boulay,
B. Broerman,
T. Bromwich,
J. F. Bueno,
A. Butcher,
B. Cai,
S. Chan,
M. Chen,
R. Chouinard,
S. Churchwell,
B. T. Cleveland,
D. Cranshaw,
K. Dering,
S. Dittmeier,
F. A. Duncan,
M. Dunford,
A. Erlandson
, et al. (77 additional authors not shown)
Abstract:
The Hamamatsu R5912-HQE photomultiplier-tube (PMT) is a novel high-quantum efficiency PMT. It is currently used in the DEAP-3600 dark matter detector and is of significant interest for future dark matter and neutrino experiments where high signal yields are needed.
We report on the methods developed for in-situ characterization and monitoring of DEAP's 255 R5912-HQE PMTs. This includes a detaile…
▽ More
The Hamamatsu R5912-HQE photomultiplier-tube (PMT) is a novel high-quantum efficiency PMT. It is currently used in the DEAP-3600 dark matter detector and is of significant interest for future dark matter and neutrino experiments where high signal yields are needed.
We report on the methods developed for in-situ characterization and monitoring of DEAP's 255 R5912-HQE PMTs. This includes a detailed discussion of typical measured single-photoelectron charge distributions, correlated noise (afterpulsing), dark noise, double, and late pulsing characteristics. The characterization is performed during the detector commissioning phase using laser light injected through a light diffusing sphere and during normal detector operation using LED light injected through optical fibres.
△ Less
Submitted 29 January, 2019; v1 submitted 29 May, 2017;
originally announced May 2017.
-
Measurement and simulation of the muon-induced neutron yield in lead
Authors:
L. Reichhart,
A. Lindote,
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. Bewick,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
V. Francis,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. A. Kudryavtsev,
V. N. Lebedenko,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. St J. Murphy
, et al. (14 additional authors not shown)
Abstract:
A measurement is presented of the neutron production rate in lead by high energy cosmic-ray muons at a depth of 2850 m water equivalent (w.e.) and a mean muon energy of 260 GeV. The measurement exploits the delayed coincidences between muons and the radiative capture of induced neutrons in a highly segmented tonne scale plastic scintillator detector. Detailed Monte Carlo simulations reproduce well…
▽ More
A measurement is presented of the neutron production rate in lead by high energy cosmic-ray muons at a depth of 2850 m water equivalent (w.e.) and a mean muon energy of 260 GeV. The measurement exploits the delayed coincidences between muons and the radiative capture of induced neutrons in a highly segmented tonne scale plastic scintillator detector. Detailed Monte Carlo simulations reproduce well the measured capture times and multiplicities and, within the dynamic range of the instrumentation, the spectrum of energy deposits. By comparing measurements with simulations of neutron capture rates a neutron yield in lead of (5.78^{+0.21}_{-0.28}) x 10^{-3} neutrons/muon/(g/cm^{2}) has been obtained. Absolute agreement between simulation and data is of order 25%. Consequences for deep underground rare event searches are discussed.
△ Less
Submitted 4 November, 2013; v1 submitted 18 February, 2013;
originally announced February 2013.
-
Position Reconstruction in a Dual Phase Xenon Scintillation Detector
Authors:
V. N. Solovov,
V. A. Belov,
D. Yu. Akimov,
H. M. Araújo,
E. J. Barnes,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Lüscher,
P. Majewski,
A. St J. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha
, et al. (11 additional authors not shown)
Abstract:
We studied the application of statistical reconstruction algorithms, namely maximum likelihood and least squares methods, to the problem of event reconstruction in a dual phase liquid xenon detector. An iterative method was developed for in-situ reconstruction of the PMT light response functions from calibration data taken with an uncollimated gamma-ray source. Using the techniques described, the…
▽ More
We studied the application of statistical reconstruction algorithms, namely maximum likelihood and least squares methods, to the problem of event reconstruction in a dual phase liquid xenon detector. An iterative method was developed for in-situ reconstruction of the PMT light response functions from calibration data taken with an uncollimated gamma-ray source. Using the techniques described, the performance of the ZEPLIN-III dark matter detector was studied for 122 keV gamma-rays. For the inner part of the detector (R<100 mm), spatial resolutions of 13 mm and 1.6 mm FWHM were measured in the horizontal plane for primary and secondary scintillation, respectively. An energy resolution of 8.1% FWHM was achieved at that energy. The possibility of using this technique for improving performance and reducing cost of scintillation cameras for medical applications is currently under study.
△ Less
Submitted 26 September, 2012; v1 submitted 7 December, 2011;
originally announced December 2011.
-
Performance data from the ZEPLIN-III second science run
Authors:
P. Majewski,
V. N. Solovov,
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
A. St J. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha
, et al. (10 additional authors not shown)
Abstract:
ZEPLIN-III is a two-phase xenon direct dark matter experiment located at the Boulby Mine (UK). After its first science run in 2008 it was upgraded with: an array of low background photomultipliers, a new anti-coincidence detector system with plastic scintillator and an improved calibration system. After 319 days of data taking the second science run ended in May 2011. In this paper we describe the…
▽ More
ZEPLIN-III is a two-phase xenon direct dark matter experiment located at the Boulby Mine (UK). After its first science run in 2008 it was upgraded with: an array of low background photomultipliers, a new anti-coincidence detector system with plastic scintillator and an improved calibration system. After 319 days of data taking the second science run ended in May 2011. In this paper we describe the instrument performance with emphasis on the position and energy reconstruction algorithm and summarise the final science results.
△ Less
Submitted 30 November, 2011;
originally announced December 2011.
-
Single electron emission in two-phase xenon with application to the detection of coherent neutrino-nucleus scattering
Authors:
E. Santos,
B. Edwards,
V. Chepel,
H. M. Araujo,
D. Yu. Akimov,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
A. Currie,
L. DeViveiros,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. StJ. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha
, et al. (12 additional authors not shown)
Abstract:
We present an experimental study of single electron emission in ZEPLIN-III, a two-phase xenon experiment built to search for dark matter WIMPs, and discuss applications enabled by the excellent signal-to-noise ratio achieved in detecting this signature. Firstly, we demonstrate a practical method for precise measurement of the free electron lifetime in liquid xenon during normal operation of these…
▽ More
We present an experimental study of single electron emission in ZEPLIN-III, a two-phase xenon experiment built to search for dark matter WIMPs, and discuss applications enabled by the excellent signal-to-noise ratio achieved in detecting this signature. Firstly, we demonstrate a practical method for precise measurement of the free electron lifetime in liquid xenon during normal operation of these detectors. Then, using a realistic detector response model and backgrounds, we assess the feasibility of deploying such an instrument for measuring coherent neutrino-nucleus elastic scattering using the ionisation channel in the few-electron regime. We conclude that it should be possible to measure this elusive neutrino signature above an ionisation threshold of $\sim$3 electrons both at a stopped pion source and at a nuclear reactor. Detectable signal rates are larger in the reactor case, but the triggered measurement and harder recoil energy spectrum afforded by the accelerator source enable lower overall background and fiducialisation of the active volume.
△ Less
Submitted 13 October, 2011;
originally announced October 2011.
-
ZE3RA: The ZEPLIN-III Reduction and Analysis Package
Authors:
F. Neves,
D. Yu. Akimov,
H. M. Araújo,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
V. Chepel,
A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Lüscher,
P. Majewski,
A. St J. Murphy,
S. M. Paling,
J. Pinto da Cunha,
R. Preece
, et al. (12 additional authors not shown)
Abstract:
ZE3RA is the software package responsible for processing the raw data from the ZEPLIN-III dark matter experiment and its reduction into a set of parameters used in all subsequent analyses. The detector is a liquid xenon time projection chamber with scintillation and electroluminescence signals read out by an array of 31 photomultipliers. The dual range 62-channel data stream is optimised for the d…
▽ More
ZE3RA is the software package responsible for processing the raw data from the ZEPLIN-III dark matter experiment and its reduction into a set of parameters used in all subsequent analyses. The detector is a liquid xenon time projection chamber with scintillation and electroluminescence signals read out by an array of 31 photomultipliers. The dual range 62-channel data stream is optimised for the detection of scintillation pulses down to a single photoelectron and of ionisation signals as small as those produced by single electrons. We discuss in particular several strategies related to data filtering, pulse finding and pulse clustering which are tuned to recover the best electron/nuclear recoil discrimination near the detection threshold, where most dark matter elastic scattering signatures are expected. The software was designed assuming only minimal knowledge of the physics underlying the detection principle, allowing an unbiased analysis of the experimental results and easy extension to other detectors with similar requirements.
△ Less
Submitted 4 June, 2011;
originally announced June 2011.
-
Nuclear recoil scintillation and ionisation yields in liquid xenon from ZEPLIN-III data
Authors:
M. Horn,
V. A. Belov,
D. Yu. Akimov,
H. M. Araújo,
E. J. Barnes,
A. A. Burenkov,
V. Chepel,
A. Currie,
B. Edwards,
C. Ghag,
A. Hollingsworth,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Lüscher,
P. Majewski,
A. StJ. Murphy,
F. Neves,
S. M. Paling,
J. Pinto da Cunha,
R. Preece,
J. J. Quenby
, et al. (11 additional authors not shown)
Abstract:
Scintillation and ionisation yields for nuclear recoils in liquid xenon above 10 keVnr (nuclear recoil energy) are deduced from data acquired using broadband Am-Be neutron sources. The nuclear recoil data from several exposures to two sources were compared to detailed simulations. Energy-dependent scintillation and ionisation yields giving acceptable fits to the data were derived. Efficiency and r…
▽ More
Scintillation and ionisation yields for nuclear recoils in liquid xenon above 10 keVnr (nuclear recoil energy) are deduced from data acquired using broadband Am-Be neutron sources. The nuclear recoil data from several exposures to two sources were compared to detailed simulations. Energy-dependent scintillation and ionisation yields giving acceptable fits to the data were derived. Efficiency and resolution effects are treated using a light collection Monte Carlo, measured photomultiplier response profiles and hardware trigger studies. A gradual fall in scintillation yield below ~40 keVnr is found, together with a rising ionisation yield; both are in good agreement with the latest independent measurements. The analysis method is applied to both the most recent ZEPLIN-III data, acquired with a significantly upgraded detector and a precision-calibrated Am-Be source, as well as to the earlier data from the first run in 2008. A new method for deriving the recoil scintillation yield, which includes sub-threshold S1 events, is also presented which confirms the main analysis.
△ Less
Submitted 17 October, 2011; v1 submitted 3 June, 2011;
originally announced June 2011.
-
Radioactivity Backgrounds in ZEPLIN-III
Authors:
H. M. Araujo,
D. Yu. Akimov,
E. J. Barnes,
V. A. Belov,
A. Bewick,
A. A. Burenkov,
V. Chepel. A. Currie,
L. DeViveiros,
B. Edwards,
C. Ghag,
A. Hollingsworth,
M. Horn,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
P. Majewski,
A. StJ. Murphy. F. Neves,
S. M. Paling,
J. Pinto da Cunha,
R. Preece,
J. J. Quenby
, et al. (10 additional authors not shown)
Abstract:
We examine electron and nuclear recoil backgrounds from radioactivity in the ZEPLIN-III dark matter experiment at Boulby. The rate of low-energy electron recoils in the liquid xenon WIMP target is 0.75$\pm$0.05 events/kg/day/keV, which represents a 20-fold improvement over the rate observed during the first science run. Energy and spatial distributions agree with those predicted by component-level…
▽ More
We examine electron and nuclear recoil backgrounds from radioactivity in the ZEPLIN-III dark matter experiment at Boulby. The rate of low-energy electron recoils in the liquid xenon WIMP target is 0.75$\pm$0.05 events/kg/day/keV, which represents a 20-fold improvement over the rate observed during the first science run. Energy and spatial distributions agree with those predicted by component-level Monte Carlo simulations propagating the effects of the radiological contamination measured for materials employed in the experiment. Neutron elastic scattering is predicted to yield 3.05$\pm$0.5 nuclear recoils with energy 5-50 keV per year, which translates to an expectation of 0.4 events in a 1-year dataset in anti-coincidence with the veto detector for realistic signal acceptance. Less obvious background sources are discussed, especially in the context of future experiments. These include contamination of scintillation pulses with Cherenkov light from Compton electrons and from $β$ activity internal to photomultipliers, which can increase the size and lower the apparent time constant of the scintillation response. Another challenge is posed by multiple-scatter $γ$-rays with one or more vertices in regions that yield no ionisation. If the discrimination power achieved in the first run can be replicated, ZEPLIN-III should reach a sensitivity of $\sim 1 \times 10^{-8}$ pb$\cdot$year to the scalar WIMP-nucleon elastic cross-section, as originally conceived.
△ Less
Submitted 12 August, 2011; v1 submitted 18 April, 2011;
originally announced April 2011.
-
Calibration of Photomultiplier Arrays
Authors:
F. Neves,
V. Chepel,
D. Yu. Akimov,
H. M. Araujo,
E. J. Barnes,
V. A. Belov,
A. A. Burenkov,
A. Currie,
B. Edwards,
C. Ghag,
M. Horn,
A. J. Hughes,
G. E. Kalmus,
A. S. Kobyakin,
A. G. Kovalenko,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
K. Lyons,
P. Majewski,
A. StJ. Murphy,
J. Pinto da Cunha,
R. Preece,
J. J. Quenby
, et al. (9 additional authors not shown)
Abstract:
A method is described that allows calibration and assessment of the linearity of response of an array of photomultiplier tubes. The method does not require knowledge of the photomultiplier single photoelectron response model and uses science data directly, thus eliminating the need for dedicated data sets. In this manner all photomultiplier working conditions (e.g. temperature, external fields,…
▽ More
A method is described that allows calibration and assessment of the linearity of response of an array of photomultiplier tubes. The method does not require knowledge of the photomultiplier single photoelectron response model and uses science data directly, thus eliminating the need for dedicated data sets. In this manner all photomultiplier working conditions (e.g. temperature, external fields, etc) are exactly matched between calibration and science acquisitions. This is of particular importance in low background experiments such as ZEPLIN-III, where methods involving the use of external light sources for calibration are severely constrained.
△ Less
Submitted 15 May, 2009;
originally announced May 2009.
-
Measurement of single electron emission in two-phase xenon
Authors:
B. Edwards,
H. M. Araujo,
V. Chepel,
D. Cline,
T. Durkin,
J. Gao,
C. Ghag,
E. V. Korolkova,
V. N. Lebedenko,
A. Lindote,
M. I. Lopes,
R. Luscher,
A. St. J. Murphy,
F. Neves,
W. Ooi,
J. Pinto da Cunha,
R. M. Preece,
G. Salinas,
C. Silva,
V. N. Solovov,
N. J. T. Smith,
P. F. Smith,
T. J. Sumner,
C. Thorne,
R. J. Walker
, et al. (3 additional authors not shown)
Abstract:
We present the first measurements of the electroluminescence response to the emission of single electrons in a two-phase noble gas detector. Single ionization electrons generated in liquid xenon are detected in a thin gas layer during the 31-day background run of the ZEPLIN-II experiment, a two-phase xenon detector for WIMP dark matter searches. Both the pressure dependence and magnitude of the…
▽ More
We present the first measurements of the electroluminescence response to the emission of single electrons in a two-phase noble gas detector. Single ionization electrons generated in liquid xenon are detected in a thin gas layer during the 31-day background run of the ZEPLIN-II experiment, a two-phase xenon detector for WIMP dark matter searches. Both the pressure dependence and magnitude of the single-electron response are in agreement with previous measurements of electroluminescence yield in xenon. We discuss different photoionization processes as possible cause for the sample of single electrons studied in this work. This observation may have implications for the design and operation of future large-scale two-phase systems.
△ Less
Submitted 6 August, 2007;
originally announced August 2007.
-
Track Reconstruction and Performance of DRIFT Directional Dark Matter Detectors using Alpha Particles
Authors:
S. Burgos,
J. Forbes,
C. Ghag,
M. Gold,
V. A. Kudryavtsev,
T. B. Lawson,
D. Loomba,
P. Majewski,
J. E. McMillan,
D. Muna,
A. StJ. Murphy,
G. G. Nicklin,
S. M. Paling,
A. Petkov,
S. J. S. Plank,
M. Robinson,
N. Sanghi,
N. J. T. Smith,
D. P. Snowden-Ifft,
N. J. C. Spooner,
T. J. Sumner,
J. Turk,
T. Tziaferi
Abstract:
First results are presented from an analysis of data from the DRIFT-IIa and DRIFT-IIb directional dark matter detectors at Boulby Mine in which alpha particle tracks were reconstructed and used to characterise detector performance--an important step towards optimising directional technology. The drift velocity in DRIFT-IIa was [59.3 +/- 0.2 (stat) +/- 7.5 (sys)] m/s based on an analysis of natur…
▽ More
First results are presented from an analysis of data from the DRIFT-IIa and DRIFT-IIb directional dark matter detectors at Boulby Mine in which alpha particle tracks were reconstructed and used to characterise detector performance--an important step towards optimising directional technology. The drift velocity in DRIFT-IIa was [59.3 +/- 0.2 (stat) +/- 7.5 (sys)] m/s based on an analysis of naturally-occurring alpha-emitting background. The drift velocity in DRIFT-IIb was [57 +/- 1 (stat) +/- 3 (sys)] m/s determined by the analysis of alpha particle tracks from a Po-210 source. 3D range reconstruction and energy spectra were used to identify alpha particles from the decay of Rn-222, Po-218, Rn-220 and Po-216. This study found that (22 +/- 2)% of Po-218 progeny (from Rn-222 decay) are produced with no net charge in 40 Torr CS2. For Po-216 progeny (from Rn-220 decay) the uncharged fraction is (100 +0 -35)%.
△ Less
Submitted 12 July, 2007;
originally announced July 2007.