-
Metrology requirements for the integrated luminosity measurement at ILC
Authors:
Ivan Smiljanić,
Ivanka Božović,
Goran Kačarević,
Mirko Radulović,
Jasna Stevanović
Abstract:
Precision measurement of the integrated luminosity $\mathcal{L}$ at future Higgs factories, including ILC, is of crucial importance for the cross-section measurements, and in particular for the line-shape measurements at the Z-pole. Since there is no up-to-date estimate of the integrated luminosity uncertainties arising from metrology effects at ILC, here we review a feasibility of the targeted pr…
▽ More
Precision measurement of the integrated luminosity $\mathcal{L}$ at future Higgs factories, including ILC, is of crucial importance for the cross-section measurements, and in particular for the line-shape measurements at the Z-pole. Since there is no up-to-date estimate of the integrated luminosity uncertainties arising from metrology effects at ILC, here we review a feasibility of the targeted precision of $\mathcal{L}$ at foreseen ILC center-of-mass energies: 91.2 GeV, 250 GeV, 500 GeV and 1 TeV.
△ Less
Submitted 3 July, 2024;
originally announced July 2024.
-
Uncertainties from metrology in the integrated luminosity measurement with the updated design of a detector at CEPC
Authors:
Ivan Smiljanic,
Ivanka Bozovic,
Goran Kacarevic
Abstract:
In order to measure integrated luminosity with a required precision of $10^{-4}$ at the $Z^0$ pole, proposed CEPC $e^{+}e^{-}$ collider requires a luminometer, a specially designed calorimeter placed in the very forward region to identify Bhabha scattering at low polar angles. Usually, such a device is placed at the outgoing beams, to keep the spatial symmetries of the head-on collisions at accele…
▽ More
In order to measure integrated luminosity with a required precision of $10^{-4}$ at the $Z^0$ pole, proposed CEPC $e^{+}e^{-}$ collider requires a luminometer, a specially designed calorimeter placed in the very forward region to identify Bhabha scattering at low polar angles. Usually, such a device is placed at the outgoing beams, to keep the spatial symmetries of the head-on collisions at accelerators with a non-zero crossing angle. At CEPC it is currently proposed to place the luminometer on the z-axis. We review a feasibility of a measurement of the integrated luminosity at the $Z^{0}$ pole with the required precision, concerning the luminometer centered around the z-axis and the post-CDR beam properties.
△ Less
Submitted 3 July, 2024; v1 submitted 29 April, 2024;
originally announced April 2024.
-
Very forward calorimeters for future electron-positron colliders
Authors:
Ivan Smiljanic
Abstract:
Detectors at future $e^+e^-$ colliders need special calorimeters in the very forward region for a fast estimate and precise measurement of the luminosity, to improve the hermeticity and mask the central tracking detectors from backscattered particles. In our concept, two compact calorimeters are foreseen, LumiCal and BeamCal. Both are designed as sandwich calorimeters with very thin sensor planes…
▽ More
Detectors at future $e^+e^-$ colliders need special calorimeters in the very forward region for a fast estimate and precise measurement of the luminosity, to improve the hermeticity and mask the central tracking detectors from backscattered particles. In our concept, two compact calorimeters are foreseen, LumiCal and BeamCal. Both are designed as sandwich calorimeters with very thin sensor planes to keep the Molière radius small, facilitating such the measurement of electron showers in the presence of background. Silicon sensor prototypes and dedicated FE ASICs have been developed and produced. The ASICs match the timing and dynamic range requirements. In the recent beam tests, a multi-plane compact prototype was equipped with thin sensor planes fully assembled with the new readout electronics and installed in 1 mm gaps between tungsten plates of one radiation length thickness. The latest status of the calorimeter prototype development will be presented, including selected performance results, obtained in a 5 GeV electron beam at DESY, as well as the expected performance obtained from simulation.
△ Less
Submitted 11 January, 2023;
originally announced January 2023.
-
Measurement of the H to ZZ branching fraction at 350 GeV and 3 TeV CLIC
Authors:
N. Vukašinović,
I. Božović-Jelisavčić,
G. Kačarević,
M. Radulović,
J. Stevanović,
G. Milutinović-Dumbelović,
T. Agatonović-Jovin,
I. Smiljanić
Abstract:
In this paper we investigate the prospects for measuring the branching fraction of the Standard Model Higgs boson decay into a pair of $Z$ bosons at the future Compact Linear Collider (CLIC) at 350 GeV and 3 TeV centre-of-mass energies. Studies are performed using a detailed simulation of the detector for CLIC, taking into consideration all relevant physics and beam-induced background processes. I…
▽ More
In this paper we investigate the prospects for measuring the branching fraction of the Standard Model Higgs boson decay into a pair of $Z$ bosons at the future Compact Linear Collider (CLIC) at 350 GeV and 3 TeV centre-of-mass energies. Studies are performed using a detailed simulation of the detector for CLIC, taking into consideration all relevant physics and beam-induced background processes. It is shown that the product of the Higgs production cross-section and the branching fraction BR(${H\rightarrow\thinspace ZZ^\ast}$) can be measured with a relative statistical uncertainty of 20% (3.0%) at a centre-of-mass energy of 350 GeV (3 TeV) using semileptonic final states, assuming an integrated luminosity of 1 ab$^{-1}$ (5 ab$^{-1}$).
△ Less
Submitted 9 February, 2022;
originally announced February 2022.
-
MEASUREMENT OF THE HIGGS BRANCHING RATIO BR($H\rightarrowγγ$) AT 3 TeV CLIC
Authors:
G. Kacarevic,
I. Bozovic Jelisavcic,
N. Vukasinovic,
I. Smiljanic,
M. Radulovic,
J. Stevanovic,
T. Agatonovic Jovin,
G. Milutinovic Dumbelovic
Abstract:
In this paper we address the potential of a 3 TeV centre-of-mass energy Compact Linear Collider (CLIC) to measure the branching fraction of the Higgs boson decay to two photons, BR($H\rightarrowγγ$). Since photons are massless, the Higgs boson coupling to photons is realized through higher order processes involving heavy particles either from the Standard Model or beyond. Any deviation of the meas…
▽ More
In this paper we address the potential of a 3 TeV centre-of-mass energy Compact Linear Collider (CLIC) to measure the branching fraction of the Higgs boson decay to two photons, BR($H\rightarrowγγ$). Since photons are massless, the Higgs boson coupling to photons is realized through higher order processes involving heavy particles either from the Standard Model or beyond. Any deviation of the measured BR($H\rightarrowγγ$), and consequently of the Higgs coupling $g_{Hγγ}$ from the predictions of the Standard Model, may indicate New Physics. The Higgs decay to two photons is thus an interesting probe of the Higgs sector.
This study is performed using simulation of the detector for CLIC and by considering all relevant physics and beam-induced processes in a full reconstruction chain. It is shown that the product of the Higgs production cross-section in $W^+W^-$ fusion and BR($H\rightarrowγγ$) can be measured with a relative statistical uncertainty of 5.5\%, assuming the integrated luminosity of 5 ab$^{-1}$ and unpolarized beams.
△ Less
Submitted 10 January, 2022;
originally announced January 2022.
-
Integrated luminosity measurement at CEPC
Authors:
Ivan Smiljanić,
Ivanka Božović-Jelisavčić,
Goran Kačarević,
Nataša Vukašinović,
Tatjana Agatonović-Jovin,
Gordana Milutinović-Dumbelović,
Jasna Stevanović,
Mirko Radulović
Abstract:
The very forward region is one of the most challenging regions to instrument at a future $e^+e^-$ collider. At CEPC, machine-detector interface includes, among others, a calorimeter dedicated for precision measurement of the integrated luminosity at a permille level or better. Here we review a feasibility of such precision, from the point of view of luminometer mechanical precision and positioning…
▽ More
The very forward region is one of the most challenging regions to instrument at a future $e^+e^-$ collider. At CEPC, machine-detector interface includes, among others, a calorimeter dedicated for precision measurement of the integrated luminosity at a permille level or better. Here we review a feasibility of such precision, from the point of view of luminometer mechanical precision and positioning, beam-related requirements and physics background.A method of the effective center-of-mass determination from $e^+e^- \to μ^+μ^-$, initially proposed for FCC, is also discussed for the CEPC beams.
△ Less
Submitted 31 January, 2022; v1 submitted 13 May, 2021;
originally announced May 2021.
-
Systematic uncertainties in integrated luminosity measurement at CEPC
Authors:
Ivan Smiljanic,
Ivanka Bozovic Jelisavcic,
Goran Kacarevic,
Natasa Vukasinovic,
Ivana Vidakovic,
Vladimir Rekovic
Abstract:
The very forward region is one of the most challenging regions to instrument at a future $e^+e^-$ collider. At CEPC, machine-detector interface includes, among others, a calorimeter dedicated for precision measurement of the integrated luminosity at a per mill level or better. Here we review a feasibility of such precision, from the point of view systematic effects arising from luminometer mechani…
▽ More
The very forward region is one of the most challenging regions to instrument at a future $e^+e^-$ collider. At CEPC, machine-detector interface includes, among others, a calorimeter dedicated for precision measurement of the integrated luminosity at a per mill level or better. Here we review a feasibility of such precision, from the point of view systematic effects arising from luminometer mechanical precision and positioning, beam-related requirements and physics background from two-photon processes. The impact of the beam energy spread and its uncertainty on the integrated luminosity precision is also discussed, as well as the achievable beam energy spread precision with the post-CDR CEPC beams.
△ Less
Submitted 23 November, 2022; v1 submitted 28 October, 2020;
originally announced October 2020.
-
Beam-spread determination for luminosity measurement at CEPC
Authors:
Ivan Smiljanic,
Ivanka Bozovic-Jelisavcic,
Goran Kacarevic
Abstract:
Any asymmetry in energy of the colliding beams will lead to a longitudinal boost of the center-of-mass frame of colliding particles w.r.t. the laboratory frame and consequently to the counting loss in luminometer due to the loss of colinearity of Bhabha final states. At CEPC running at the Z0 pole, asymmetry in energy of the colliding beams should be known as well as 12.5% of the beam-spread, in o…
▽ More
Any asymmetry in energy of the colliding beams will lead to a longitudinal boost of the center-of-mass frame of colliding particles w.r.t. the laboratory frame and consequently to the counting loss in luminometer due to the loss of colinearity of Bhabha final states. At CEPC running at the Z0 pole, asymmetry in energy of the colliding beams should be known as well as 12.5% of the beam-spread, in order to control the uncertainty of Bhabha count at the level of 0.01%. Here we discuss the method, initially proposed for FCCee, to determine variation of the beam-spread from the measurement of the effective center-of-mass energy in $e^+e^- \to μ^+μ^-$ collisions.
△ Less
Submitted 10 February, 2020;
originally announced February 2020.
-
Measurement of shower development and its Molière radius with a four-plane LumiCal test set-up
Authors:
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
Y. Benhammou,
L. Bortko,
O. Borysov,
M. Borysova,
I. Bozovic-Jelisavcic,
G. Chelkov,
W. Daniluk,
D. Dannheim,
K. Elsener,
M. Firlej,
E. Firu,
T. Fiutowski,
V. Ghenescu,
M. Gostkin,
M. Hempel,
H. Henschel,
M. Idzik,
A. Ignatenko,
A. Ishikawa,
S. Kananov,
O. Karacheban,
W. Klempt
, et al. (35 additional authors not shown)
Abstract:
A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The objective of this beam test was to demonstrate a multi-plane tungsten/silicon operation, to study the development of the electromagnetic shower and to compare it with MC simulations. The Molière radius has been determined t…
▽ More
A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The objective of this beam test was to demonstrate a multi-plane tungsten/silicon operation, to study the development of the electromagnetic shower and to compare it with MC simulations. The Molière radius has been determined to be 24.0 +/- 0.6 (stat.) +/- 1.5 (syst.) mm using a parametrization of the shower shape. Very good agreement was found between data and a detailed Geant4 simulation.
△ Less
Submitted 12 March, 2018; v1 submitted 10 May, 2017;
originally announced May 2017.
-
ECFA Detector R&D Panel, Review Report
Authors:
The FCAL Collaboration,
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
J. Aguilar,
E. Alvarez,
P. Bambade,
L. Bortko,
I. Bozovic-Jelisavcic,
E. Castro,
G. Chelkov,
C. Coca,
W. Daniluk,
A. Dragone,
L. Dumitru,
K. Elsener,
I. Emeliantchik,
E. Firu,
J. Fischer,
T. Fiutowski,
V. Ghenescu,
M. Gostkin,
G. Grzelak,
G. Haller,
H. Henschel
, et al. (46 additional authors not shown)
Abstract:
Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 10$^{-3}$ at the ILC and 10$^{-2}$ at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The in…
▽ More
Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 10$^{-3}$ at the ILC and 10$^{-2}$ at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The intensity and the spatial shape of these depositions will provide a fast luminosity estimate, as well as determination of beam parameters. The sensors of this calorimeter must be radiation-hard. Both devices will improve the e.m. hermeticity of the detector in the search for new particles. Finely segmented and very compact electromagnetic calorimeters will match these requirements. Due to the high occupancy, fast front-end electronics will be needed. Monte Carlo studies were performed to investigate the impact of beam-beam interactions and physics background processes on the luminosity measurement, and of beamstrahlung on the performance of BeamCal, as well as to optimise the design of both calorimeters. Dedicated sensors, front-end and ADC ASICs have been designed for the ILC and prototypes are available. Prototypes of sensor planes fully assembled with readout electronics have been studied in electron beams.
△ Less
Submitted 19 November, 2014; v1 submitted 18 November, 2014;
originally announced November 2014.
-
Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector
Authors:
The FCAL Collaboration,
H. Abramowicz,
A. Abusleme,
K. Afanaciev,
J. Aguilar,
E. Alvarez,
D. Avila,
Y. Benhammou,
L. Bortko,
O. Borysov,
M. Bergholz,
I. Bozovic-Jelisavcic,
E. Castro,
G. Chelkov,
C. Coca,
W. Daniluk,
L. Dumitru,
K. Elsener,
V. Fadeyev,
M. Firlej,
E. Firu,
T. Fiutowski,
V. Ghenescu,
M. Gostkin,
H. Henschel
, et al. (44 additional authors not shown)
Abstract:
Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sens…
▽ More
Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sensor are presented. A deconvolution method is successfully applied, and a comparison of the measured shower shape as a function of the absorber depth with a Monte-Carlo simulation is given.
△ Less
Submitted 1 June, 2015; v1 submitted 17 November, 2014;
originally announced November 2014.
-
Precision luminosity measurement at ILC
Authors:
I. Bozovic-Jelisavcic,
S. Lukic,
M. Pandurovic,
I. Smiljanic
Abstract:
In these proceedings a novel approach to deal with the beam-induced effects in luminosity measurement is presented. Based on the relativistic kinematics of the collision frame of the Bhabha process, the beam-beam related uncertainties can be reduced to the permille level independently of a precision with which the beam parameters are known. Specific event selection combined with the corrective met…
▽ More
In these proceedings a novel approach to deal with the beam-induced effects in luminosity measurement is presented. Based on the relativistic kinematics of the collision frame of the Bhabha process, the beam-beam related uncertainties can be reduced to the permille level independently of a precision with which the beam parameters are known. Specific event selection combined with the corrective methods we introduce, leads to the systematic uncertainty from the beam-induced effects to be at a few permille level in the peak region above the 80% of the nominal centre-of-mass energies at ILC.
△ Less
Submitted 28 March, 2014;
originally announced March 2014.
-
Luminosity measurement at ILC
Authors:
I. Bozovic-Jelisavcic,
S. Lukic,
G. Milutinovic Dumbelovic,
M. Pandurovic,
I. Smiljanic
Abstract:
In this paper we describe a method of luminosity measurement at the future linear collider ILC that estimates and corrects for the impact of the dominant sources of systematic uncertainty originating from the beam-induced effects and the background from physics processes. Based on the relativistic kinematics of the collision frame of the Bhabha process, the beam-beam related uncertainty is reduced…
▽ More
In this paper we describe a method of luminosity measurement at the future linear collider ILC that estimates and corrects for the impact of the dominant sources of systematic uncertainty originating from the beam-induced effects and the background from physics processes. Based on the relativistic kinematics of the collision frame of the Bhabha process, the beam-beam related uncertainty is reduced to a permille independently of the precision with which the beam parameters are known. With the specific event selection, different from the isolation cuts based on topology of the signal used at LEP, combined with the corrective methods we introduce, the overall systematic uncertainty in the peak region above 80% of the nominal center-of-mass energy meets the physics requirements to be at the few permille level at all ILC energies.
△ Less
Submitted 21 August, 2013; v1 submitted 15 April, 2013;
originally announced April 2013.
-
Correction of beam-beam effects in luminosity measurement at ILC
Authors:
Strahinja Lukić,
Ivan Smiljanić
Abstract:
Three methods for handling beam-beam effects in luminosity measurement at ILC are tested and evaluated in this work. The first method represents an optimization of the LEP-type asymmetric selection cuts that reduce the counting biases. The second method uses the experimentally reconstructed shape of the $\sqrt{s'}$ spectrum to determine the Beamstrahlung component of the bias. The last, recently p…
▽ More
Three methods for handling beam-beam effects in luminosity measurement at ILC are tested and evaluated in this work. The first method represents an optimization of the LEP-type asymmetric selection cuts that reduce the counting biases. The second method uses the experimentally reconstructed shape of the $\sqrt{s'}$ spectrum to determine the Beamstrahlung component of the bias. The last, recently proposed, collision-frame method relies on the reconstruction of the collision-frame velocity to define the selection function in the collision frame both in experiment and in theory. Thus the luminosity expression is insensitive to the difference between the CM frame of the collision and the lab frame. The collision-frame method is independent of the knowledge of the beam parameters, and it allows an accurate reconstruction of the luminosity spectrum above 80 % of the nominal CM energy. However, it gives no precise infromation about luminosity below 80 % of the nominal CM energy. The compatibility of diverse selection cuts for background reduction with the collision-frame method is addressed.
△ Less
Submitted 4 March, 2013; v1 submitted 29 November, 2012;
originally announced November 2012.
-
Forward Instrumentation for ILC Detectors
Authors:
Halina Abramowicz,
Angel Abusleme,
Konstantin Afanaciev,
Jonathan Aguilar,
Prasoon Ambalathankandy,
Philip Bambade,
Matthias Bergholz,
Ivanka Bozovic-Jelisavcic,
Elena Castro,
Georgy Chelkov,
Cornelia Coca,
Witold Daniluk,
Angelo Dragone,
Laurentiu Dumitru,
Konrad Elsener,
Igor Emeliantchik,
Tomasz Fiutowski,
Mikhail Gostkin,
Christian Grah,
Grzegorz Grzelak,
Gunter Haller,
Hans Henschel,
Alexandr Ignatenko,
Marek Idzik,
Kazutoshi Ito
, et al. (33 additional authors not shown)
Abstract:
Two special calorimeters are foreseen for the instrumentation of the very forward region of the ILC detector, a luminometer designed to measure the rate of low angle Bhabha scattering events with a precision better than 10-3 and a low polar angle calorimeter, adjacent to the beam-pipe. The latter will be hit by a large amount of beamstrahlung remnants. The amount and shape of these depositions wil…
▽ More
Two special calorimeters are foreseen for the instrumentation of the very forward region of the ILC detector, a luminometer designed to measure the rate of low angle Bhabha scattering events with a precision better than 10-3 and a low polar angle calorimeter, adjacent to the beam-pipe. The latter will be hit by a large amount of beamstrahlung remnants. The amount and shape of these depositions will allow a fast luminosity estimate and the determination of beam parameters. The sensors of this calorimeter must be radiation hard. Both devices will improve the hermeticity of the detector in the search for new particles. Finely segmented and very compact calorimeters will match the requirements. Due to the high occupancy fast front-end electronics is needed. The design of the calorimeters developed and optimised with Monte Carlo simulations is presented. Sensors and readout electronics ASICs have been designed and prototypes are available. Results on the performance of these major components are summarised.
△ Less
Submitted 3 November, 2010; v1 submitted 13 September, 2010;
originally announced September 2010.
-
Luminosity Measurement at ILC
Authors:
I. Bozovic-Jelisavcic,
H. Abramowicz,
P. Bambade,
T. Jovin,
M. Pandurovic,
B. Pawlik,
C. Rimbault,
I. Sadeh,
I. Smiljanic
Abstract:
More than twenty institutes join the FCAL Collaboration in study of design of the very forward region of a detector for ILC and CLIC. Of particular importance is an accurate luminosity measurement to the level of 10-3, a requirement driven by the potential for precision physics at a future linear collider. In this paper, the method for luminosity measurement, requirements on luminometer and its in…
▽ More
More than twenty institutes join the FCAL Collaboration in study of design of the very forward region of a detector for ILC and CLIC. Of particular importance is an accurate luminosity measurement to the level of 10-3, a requirement driven by the potential for precision physics at a future linear collider. In this paper, the method for luminosity measurement, requirements on luminometer and its integration in the forward region are presented. The impact of several effects contributing to the systematic uncertainty of luminosity measurement is given.
△ Less
Submitted 13 June, 2010;
originally announced June 2010.