Influence of mechanical deformations on the performance of a coaxial shield for a cryogenic current comparator
Authors:
Nicolas Marsic,
Wolfgang F. O. Müller,
Volker Tympel,
Thomas Stöhlker,
Max Stapelfeld,
Frank Schmidl,
Matthias Schmelz,
Vyacheslav Zakosarenko,
Ronny Stolz,
David Haider,
Thomas Sieber,
Marcus Schwickert,
Herbert De Gersem
Abstract:
This paper studies the impact of mechanical deformations on the performance of a coaxial-type cryogenic current comparator (CCC). Such deformations may become a concern as the size of the CCC increases (e.g. when used as a diagnostic device in a particle accelerator facility involving beamlines with a large diameter). In addition to static deformations, this paper also discusses the effect of mech…
▽ More
This paper studies the impact of mechanical deformations on the performance of a coaxial-type cryogenic current comparator (CCC). Such deformations may become a concern as the size of the CCC increases (e.g. when used as a diagnostic device in a particle accelerator facility involving beamlines with a large diameter). In addition to static deformations, this paper also discusses the effect of mechanical vibrations on the CCC performance.
△ Less
Submitted 21 November, 2022;
originally announced November 2022.
-
Numerical analysis of a folded superconducting coaxial shield for cryogenic current comparators
Authors:
Nicolas Marsic,
Wolfgang F. O. Müller,
Herbert De Gersem,
Matthias Schmelz,
Vyacheslav Zakosarenko,
Ronny Stolz,
Febin Kurian,
Thomas Sieber,
Marcus Schwickert
Abstract:
This paper presents a new shield configuration for cryogenic current comparators (CCCs), namely the folded coaxial geometry. An analytical model describing its shielding performance is first developed, and then validated by means of finite element simulations. Thanks to this model, the fundamental properties of the new shield are highlighted. Additionally, this paper compares the volumetric perfor…
▽ More
This paper presents a new shield configuration for cryogenic current comparators (CCCs), namely the folded coaxial geometry. An analytical model describing its shielding performance is first developed, and then validated by means of finite element simulations. Thanks to this model, the fundamental properties of the new shield are highlighted. Additionally, this paper compares the volumetric performance of the folded coaxial shield to the one of a ring shield, the latter being installed in many CCCs for measuring particle beam currents in accelerator facilities.
△ Less
Submitted 21 November, 2022;
originally announced November 2022.
-
The Cryogenic Storage Ring CSR
Authors:
Robert von Hahn,
Arno Becker,
Felix Berg,
Klaus Blaum,
Christian Breitenfeldt,
Hisham Fadil,
Florian Fellenberger,
Michael Froese,
Sebastian George,
Jürgen Göck,
Manfred Grieser,
Florian Grussie,
Elisabeth A. Guerin,
Oded Heber,
Philipp Herwig,
Jonas Karthein,
Claude Krantz,
Holger Kreckel,
Michael Lange,
Felix Laux,
Svenja Lohmann,
Sebastian Menk,
Christian Meyer,
Preeti M. Mishra,
Oldřich Novotný
, et al. (19 additional authors not shown)
Abstract:
An electrostatic cryogenic storage ring, CSR, for beams of anions and cations with up to 300 keV kinetic energy per unit charge has been designed, constructed and put into operation. With a circumference of 35 m, the ion-beam vacuum chambers and all beam optics are in a cryostat and cooled by a closed-cycle liquid helium system. At temperatures as low as (5.5 $\pm$ 1) K inside the ring, storage ti…
▽ More
An electrostatic cryogenic storage ring, CSR, for beams of anions and cations with up to 300 keV kinetic energy per unit charge has been designed, constructed and put into operation. With a circumference of 35 m, the ion-beam vacuum chambers and all beam optics are in a cryostat and cooled by a closed-cycle liquid helium system. At temperatures as low as (5.5 $\pm$ 1) K inside the ring, storage time constants of several minutes up to almost an hour were observed for atomic and molecular, anion and cation beams at an energy of 60 keV. The ion-beam intensity, energy-dependent closed-orbit shifts (dispersion) and the focusing properties of the machine were studied by a system of capacitive pickups. The Schottky-noise spectrum of the stored ions revealed a broadening of the momentum distribution on a time scale of 1000 s. Photodetachment of stored anions was used in the beam lifetime measurements. The detachment rate by anion collisions with residual-gas molecules was found to be extremely low. A residual-gas density below 140 cm$^{-3}$ is derived, equivalent to a room-temperature pressure below 10$^{-14}$ mbar. Fast atomic, molecular and cluster ion beams stored for long periods of time in a cryogenic environment will allow experiments on collision- and radiation-induced fragmentation processes of ions in known internal quantum states with merged and crossed photon and particle beams.
△ Less
Submitted 5 June, 2016;
originally announced June 2016.