Flattened photon beams, an obsolete feature in modern linear accelerators
Authors:
E. Ishmael Parsai,
Elahheh Salari,
Diana Shvydka,
Jui Wan
Abstract:
Background: With the advent of Intensity Modulated Radiotherapy (IMRT) and recently, Volumetric Modulated Arc Therapy (VMAT), treatment planning using Flattening Filter Free (FFF) beams can meet all of the energy requirements in radiation therapy clinics. Manufacturers of linear accelerators no longer need to install a flattening filter (FF) in gantry head. This study aims to provide evidence of t…
▽ More
Background: With the advent of Intensity Modulated Radiotherapy (IMRT) and recently, Volumetric Modulated Arc Therapy (VMAT), treatment planning using Flattening Filter Free (FFF) beams can meet all of the energy requirements in radiation therapy clinics. Manufacturers of linear accelerators no longer need to install a flattening filter (FF) in gantry head. This study aims to provide evidence of the superiority of FFF to FF through both dosimetric measurements and clinical treatment plans. Materials and Methods: A 50x50x50cm3 water phantom was created in the RayStation treatment planning system (TPS) for dosimetry comparisons. Flat beam profiles were generated using FFF beam through an optimization process for 10x10 to 30x30cm2 field sizes. Next, a comparison of treatment plans was made using 21 Head and Neck and 14 Lung/Mediastinum treatment sites using 6MV and 6MV-FFF beams. Results: Using FFF beams, profiles with flatness and symmetry identical to or better than those of the flattened beams were produced. At the very edge of the optimized plans for FFF beams, horns had the highest gamma index deviation <1.5% of the normalized dose. For clinical plans evaluated, most of the mean doses to organs_atrisk (OAR) volumes receiving 5% to 30% of the prescription dose were reduced with FFF beams. Conclusion: These results indicate the feasibility of delivering flat beams with FFF quality and producing treatment plans with equal or higher qualities in PTV coverage while achieving better sparing of OAR which will allow escalation of target dose if desired. Plus, removing FF will simplify the gantry head and reduces quality assurance and machine maintenance efforts.
△ Less
Submitted 9 September, 2023;
originally announced September 2023.
-
Predicting electronic stop** powers using stacking ensemble machine learning method
Authors:
Fatemeh Akbari,
Somayeh Taghizadeh,
Diana Shvydka,
Nicholas Niven Sperling,
E. Ishmael Parsai
Abstract:
Purpose: Accurate electronic stop** power data is crucial for calculating radiation-induced effects in various applications, from dosimetry and radiotherapy to particle physics. In this study, Stacking Ensemble Machine Learning (EML) algorithm was developed to predict electronic stop** power for any incident ion and target combination over a wide range of ion energies. For this purpose, five M…
▽ More
Purpose: Accurate electronic stop** power data is crucial for calculating radiation-induced effects in various applications, from dosimetry and radiotherapy to particle physics. In this study, Stacking Ensemble Machine Learning (EML) algorithm was developed to predict electronic stop** power for any incident ion and target combination over a wide range of ion energies. For this purpose, five ML models, namely BR, XGB, AdB, GB, and RF, were selected as base and meta learners to construct the final Stacking EML. Methods: 40,044 experimental measurements, from 1928 to the present, available on the International Atomic Energy Agency (IAEA) website were used to train machine learning (ML) algorithms. This database consists of 593 ion-target combinations across the energy range of 0.037 to 985 MeV. For model training, the eleven most important features were selected. The model evaluation was performed using several error metrics, including R-squared (R2), root-mean-squared-error (RMSE), mean-absolute-error (MAE), and mean-absolute-percentage-error (MAPE), on both the training and test datasets. Results: Based on model performance evaluation tests, a stack of eXtreme Gradient Boosting (XGB) and Random Forest (RF) via Bagging Regressor (BR) meta-learner had the highest lowest error margin. The value of R2=0.9985 indicated a near-ideal fit to all samples in the training data across the entire range of stop** powers. R2=0.9955 for predictions made by the model on the unseen test data suggested that the model accurately predicted the test data. Conclusions: The developed model resulted in highly accurate predictions for any ion-target combination across the whole particle energy spectrum. The associated model can serve as a universal tool to generate the stop** power data in a wide range of cases, regardless of the availability of experimental data or reliable theoretical equations.
△ Less
Submitted 30 July, 2022;
originally announced August 2022.
-
Electron backscattering for signal enhancement in a thin-film CdTe radiation detector
Authors:
Fatemeh Akbari,
Diana Shvydka
Abstract:
We investigated the possibility of augmenting the fluence of electrons traversing CdTe thin film and thus increasing the detected signal pursuing two venues: adding a high-Z metal layer to the back of the detector surface, and adding a top low-Z material to the detector layer to return its backscattered electrons. Copper (Cu) and lead (Pb) layers of varying thickness were investigated as potential…
▽ More
We investigated the possibility of augmenting the fluence of electrons traversing CdTe thin film and thus increasing the detected signal pursuing two venues: adding a high-Z metal layer to the back of the detector surface, and adding a top low-Z material to the detector layer to return its backscattered electrons. Copper (Cu) and lead (Pb) layers of varying thickness were investigated as potential metal back-reflectors, while PMMA was tried as the top cover in multilayer detector structures. The Monte Carlo (MC) radiation transport package MCNP5 was first used to model a basic multilayer structure under a Varian 6MV. It was then modified by the addition of Cu and Pb to analyze the extent of the signal enhancement and changes in secondary electron fluence spectra. Backscattering coefficients were then calculated using EGSnrc for electron sources. Analytical functions were established to represent the best-fitting curves to the simulation data. Finally, electron backscattering data were related to signal enhancement. It was found that adding a metal film below the sensitive volume of a detector increases the fraction of reflected electrons, especially in the low energy range, resulting in ~10% and 75% increased energy deposition using Cu and Pb, respectively. We also established a linear dependence between the energy deposition in the semiconductor layer and the fluence of backscattered electrons in the corresponding multilayer structure. The low-Z top layer in practically implemental thicknesses of tens of microns has a positive effect due to partial electron reflection back to the semiconductor layer. Signal enhancement in a thin-film CdTe radiation detector could be achieved using electron backscattering from metal reflectors. The methodology explored here warrants further studies to quantify achievable signal enhancement for various thin-film and other small sensitive volume detectors.
△ Less
Submitted 5 January, 2022;
originally announced January 2022.
-
Electrostatically accelerated tin whisker development under x- and gamma-rays
Authors:
Osama Oudat,
Vedheesha Arora,
E. Ishmael Parsai,
Victor G. Karpov,
Diana Shvydka
Abstract:
We observed the accelerated tin whisker development under non-destructive gamma-ray and x-ray irradiation and determined the characteristic range of radiation doses 20-30 KGy, for which that effect becomes significant. We were able to change the radiation induced whisker growth by electrically disconnecting some parts of our experimental setup thus demonstrating the electrostatic nature of the acc…
▽ More
We observed the accelerated tin whisker development under non-destructive gamma-ray and x-ray irradiation and determined the characteristic range of radiation doses 20-30 KGy, for which that effect becomes significant. We were able to change the radiation induced whisker growth by electrically disconnecting some parts of our experimental setup thus demonstrating the electrostatic nature of the accelerated whisker development. The observed acceleration factors make the ionizing radiation a potential non-destructive and readily implementable accelerated life testing tool.
△ Less
Submitted 31 May, 2020; v1 submitted 25 May, 2020;
originally announced May 2020.