-
A Point-of-Care Biosensor for Rapid Detection and Differentiation of COVID-19 Virus (SARS-CoV-2) and Influenza Virus Using Subwavelength Grating Micro-ring Resonator
Authors:
Shupeng Ning,
Hao-Chen Chang,
Kang-Chieh Fan,
Po-yu Hsiao,
Chenghao Feng,
Devan Shoemaker,
Ray T. Chen
Abstract:
In the context of continued spread of coronavirus disease 2019 (COVID-19) caused by SARS-CoV-2 and the emergence of new variants, the demand for rapid, accurate, and frequent detection is increasing. Besides, the new predominant strain, Omicron variant, manifests more similar clinical features to those of other common respiratory infections. The concurrent detection of multiple potential pathogens…
▽ More
In the context of continued spread of coronavirus disease 2019 (COVID-19) caused by SARS-CoV-2 and the emergence of new variants, the demand for rapid, accurate, and frequent detection is increasing. Besides, the new predominant strain, Omicron variant, manifests more similar clinical features to those of other common respiratory infections. The concurrent detection of multiple potential pathogens helps distinguish SARS-CoV-2 infection from other diseases with overlap** symptoms, which is significant for patients to receive tailored treatment and containing the outbreak. Here, we report a lab-on-a-chip biosensing platform for SARS-CoV-2 detection based on subwavelength grating micro-ring resonator. The sensing surface is functionalized by specific antibody against SARS-CoV-2 spike protein, which could produce redshifts of resonant peaks by antigen-antibody combination, thus achieving quantitative detection. Additionally, the sensor chip is integrated with a microfluidic chip with an anti-backflow Y-shaped structure that enables the concurrent detection of two analytes. In this study, we realized the detection and differentiation of COVID-19 and influenza A H1N1. Experimental results show that the limit of detection of our device reaches 100 fg/mL (1.31 fM) within 15 min detecting time, and cross-reactivity tests manifest the specificity of the optical diagnostic assay. Further, the integrated packaging and streamlined workflow facilitate its use for clinical applications. Thus, the biosensing platform offers a promising solution to achieve ultrasensitive, selective, multiplexed, and quantitative point-of-care detection of COVID-19.
△ Less
Submitted 11 January, 2023;
originally announced January 2023.
-
Ultra-Wide Bandgap Ga$_2$O$_3$-on-SiC MOSFETs
Authors:
Yiwen Song,
Arkka Bhattacharyya,
Anwarul Karim,
Daniel Shoemaker,
Hsien-Lien Huang,
Saurav Roy,
Craig McGray,
Jacob H. Leach,
**woo Hwang,
Sriram Krishnamoorthy,
Sukwon Choi
Abstract:
Ulta-wide bandgap semiconductors based on $β$-Ga$_2$O$_3$ offer the potential to achieve higher power switching performance, efficiency, and lower manufacturing cost than today's wide bandgap power semiconductors. However, the most critical challenge to the commercialization of Ga$_2$O$_3$ electronics is overheating, which impacts the device's performance and reliability. We fabricated a Ga$_2$O…
▽ More
Ulta-wide bandgap semiconductors based on $β$-Ga$_2$O$_3$ offer the potential to achieve higher power switching performance, efficiency, and lower manufacturing cost than today's wide bandgap power semiconductors. However, the most critical challenge to the commercialization of Ga$_2$O$_3$ electronics is overheating, which impacts the device's performance and reliability. We fabricated a Ga$_2$O$_3$/4H-SiC composite wafer using a fusion-bonding method. A low temperature ($\le$ 600 $^{\circ}$C) epitaxy and device processing approach based on low-temperature (LT) metalorganic vapor phase epitaxy is developed to grow a Ga$_2$O$_3$ epitaxial channel layer on the composite wafer and subsequently fabricate into Ga$_2$O$_3$ power MOSFETs. This LT approach is essential to preserve the structural integrity of the composite wafer. These LT-grown epitaxial Ga$_2$O$_3$ MOSFETs deliver high thermal performance (56% reduction in channel temperature), high voltage blocking capabilities up to 2.45 kV, and power figures of merit of $\sim$ 300 MW/cm$^2$, which is a record high for any heterogeneously integrated Ga$_2$O$_3$ devices reported to date. This work is the first realization of multi-kilovolt homoepitaxial Ga$_2$O$_3$ power MOSFETs fabricated on a composite substrate with high heat transfer performance which delivers state-of-the-art power density values while running much cooler than those on native substrates. Thermal characterization and modeling results reveal that a Ga$_2$O$_3$/diamond composite wafer with a reduced Ga$_2$O$_3$ thickness ($\sim$ 1 $μ$m) and thinner bonding interlayer ($<$ 10 nm) can reduce the device thermal impedance to a level lower than today's GaN-on-SiC power switches.
△ Less
Submitted 21 February, 2023; v1 submitted 13 October, 2022;
originally announced October 2022.
-
Towards Equitable, Diverse, and Inclusive Science Collaborations: The Multimessenger Diversity Network
Authors:
E. Bechtol,
K. Bechtol,
S. BenZvi,
C. Bleve,
D. Castro,
B. Cenko,
L. Corlies,
A. Furniss,
C. M. Hui,
D. Kaplan,
J. S. Key,
J. Madsen,
F. McNally,
M. McLaughlin,
R. Mukherjee,
R. Ojha,
J. Sanders,
M. Santander,
J. Schlieder,
D. H. Shoemaker,
S. Vigeland
Abstract:
The Multimessenger Diversity Network (MDN), formed in 2018, extends the basic principle of multimessenger astronomy -- that working collaboratively with different approaches enhances understanding and enables previously impossible discoveries -- to equity, diversity, and inclusion (EDI) in science research collaborations. With support from the National Science Foundation INCLUDES program, the MDN…
▽ More
The Multimessenger Diversity Network (MDN), formed in 2018, extends the basic principle of multimessenger astronomy -- that working collaboratively with different approaches enhances understanding and enables previously impossible discoveries -- to equity, diversity, and inclusion (EDI) in science research collaborations. With support from the National Science Foundation INCLUDES program, the MDN focuses on increasing EDI by sharing knowledge, experiences, training, and resources among representatives from multimessenger science collaborations. Representatives to the MDN become engagement leads in their collaboration, extending the reach of the community of practice. An overview of the MDN structure, lessons learned, and how to join are presented.
△ Less
Submitted 23 July, 2021;
originally announced July 2021.
-
130 mA/mm $β$-Ga$_2$O$_3$ MESFET with Low-Temperature MOVPE-Regrown Ohmic Contacts
Authors:
Arkka Bhattacharyya,
Saurav Roy,
Praneeth Ranga,
Daniel Shoemaker,
Yiwen Song,
James Spencer Lundh,
Sukwon Choi,
Sriram Krishnamoorthy
Abstract:
We report on the demonstration of metalorganic vapor phase epitaxy-regrown (MOVPE) ohmic contacts in an all MOVPE-grown $β$-Ga$_2$O$_3$ metal-semiconductor field effect transistor (MESFET). The low-temperature (600$^{\circ}$C) heavy (n$^{+}$) Si-doped regrown layers exhibit extremely high conductivity with sheet resistance of 73 $Ω$/$\square$ and record low metal/n$^{+}$-Ga$_2$O$_3$ contact resist…
▽ More
We report on the demonstration of metalorganic vapor phase epitaxy-regrown (MOVPE) ohmic contacts in an all MOVPE-grown $β$-Ga$_2$O$_3$ metal-semiconductor field effect transistor (MESFET). The low-temperature (600$^{\circ}$C) heavy (n$^{+}$) Si-doped regrown layers exhibit extremely high conductivity with sheet resistance of 73 $Ω$/$\square$ and record low metal/n$^{+}$-Ga$_2$O$_3$ contact resistance of 80 m$Ω$.mm and specific contact resistivity of 8.3$\times$10$^{-7}$ $Ω$.cm$^{2}$ were achieved. The fabricated MESFETs exhibit a maximum drain-to-source current of 130 mA/mm, a high I$_{ON}$/I$_{OFF}$ of $>$10$^{10}$ with a high power FOM of 25 MW/cm$^{2}$ were achieved without any field plates. Nanoparticle-assisted Raman thermometry, thermal modeling, and infrared thermography were performed to assess the device self-heating under the high current and power conditions. This demonstration shows the promise of MOVPE technique for the realization of high-performance lateral $β$-Ga$_2$O$_3$ devices and also highlights the need for device-level thermal management.
△ Less
Submitted 26 July, 2021; v1 submitted 7 March, 2021;
originally announced March 2021.
-
A Cryogenic Silicon Interferometer for Gravitational-wave Detection
Authors:
Rana X Adhikari,
Odylio Aguiar,
Koji Arai,
Bryan Barr,
Riccardo Bassiri,
Garilynn Billingsley,
Ross Birney,
David Blair,
Joseph Briggs,
Aidan F Brooks,
Daniel D Brown,
Huy-Tuong Cao,
Marcio Constancio,
Sam Cooper,
Thomas Corbitt,
Dennis Coyne,
Edward Daw,
Johannes Eichholz,
Martin Fejer,
Andreas Freise,
Valery Frolov,
Slawomir Gras,
Anna Green,
Hartmut Grote,
Eric K Gustafson
, et al. (86 additional authors not shown)
Abstract:
The detection of gravitational waves from compact binary mergers by LIGO has opened the era of gravitational wave astronomy, revealing a previously hidden side of the cosmos. To maximize the reach of the existing LIGO observatory facilities, we have designed a new instrument that will have 5 times the range of Advanced LIGO, or greater than 100 times the event rate. Observations with this new inst…
▽ More
The detection of gravitational waves from compact binary mergers by LIGO has opened the era of gravitational wave astronomy, revealing a previously hidden side of the cosmos. To maximize the reach of the existing LIGO observatory facilities, we have designed a new instrument that will have 5 times the range of Advanced LIGO, or greater than 100 times the event rate. Observations with this new instrument will make possible dramatic steps toward understanding the physics of the nearby universe, as well as observing the universe out to cosmological distances by the detection of binary black hole coalescences. This article presents the instrument design and a quantitative analysis of the anticipated noise floor.
△ Less
Submitted 9 June, 2020; v1 submitted 29 January, 2020;
originally announced January 2020.
-
Quantum correlation measurements in interferometric gravitational wave detectors
Authors:
D. V. Martynov,
V. V. Frolov,
S. Kandhasamy,
K. Izumi,
H. Miao,
N. Mavalvala,
E. D. Hall,
R. Lanza,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
C. Adams,
R. X. Adhikari,
S. B. Anderson,
A. Ananyeva,
S. Appert,
K. Arai,
S. M. Aston,
S. W. Ballmer,
D. Barker,
B. Barr,
L. Barsotti,
J. Bartlett,
I. Bartos,
J. C. Batch
, et al. (177 additional authors not shown)
Abstract:
Quantum fluctuations in the phase and amplitude quadratures of light set limitations on the sensitivity of modern optical instruments. The sensitivity of the interferometric gravitational wave detectors, such as the Advanced Laser Interferometer Gravitational wave Observatory (LIGO), is limited by quantum shot noise, quantum radiation pressure noise, and a set of classical noises. We show how the…
▽ More
Quantum fluctuations in the phase and amplitude quadratures of light set limitations on the sensitivity of modern optical instruments. The sensitivity of the interferometric gravitational wave detectors, such as the Advanced Laser Interferometer Gravitational wave Observatory (LIGO), is limited by quantum shot noise, quantum radiation pressure noise, and a set of classical noises. We show how the quantum properties of light can be used to distinguish these noises using correlation techniques. Particularly, in the first part of the paper we show estimations of the coating thermal noise and gas phase noise, hidden below the quantum shot noise in the Advanced LIGO sensitivity curve. We also make projections on the observatory sensitivity during the next science runs. In the second part of the paper we discuss the correlation technique that reveals the quantum radiation pressure noise from the background of classical noises and shot noise. We apply this technique to the Advanced LIGO data, collected during the first science run, and experimentally estimate the quantum correlations and quantum radiation pressure noise in the interferometer for the first time.
△ Less
Submitted 10 February, 2017;
originally announced February 2017.
-
The Sensitivity of the Advanced LIGO Detectors at the Beginning of Gravitational Wave Astronomy
Authors:
D. V. Martynov,
E. D. Hall,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
C. Adams,
R. X. Adhikari,
R. A. Anderson,
S. B. Anderson,
K. Arai,
M. A. Arain,
S. M. Aston,
L. Austin,
S. W. Ballmer,
M. Barbet,
D. Barker,
B. Barr,
L. Barsotti,
J. Bartlett,
M. A. Barton,
I. Bartos,
J. C. Batch,
A. S. Bell,
I. Belopolski,
J. Bergman
, et al. (239 additional authors not shown)
Abstract:
The Laser Interferometer Gravitational Wave Observatory (LIGO) consists of two widely separated 4 km laser interferometers designed to detect gravitational waves from distant astrophysical sources in the frequency range from 10 Hz to 10 kHz. The first observation run of the Advanced LIGO detectors started in September 2015 and ended in January 2016. A strain sensitivity of better than…
▽ More
The Laser Interferometer Gravitational Wave Observatory (LIGO) consists of two widely separated 4 km laser interferometers designed to detect gravitational waves from distant astrophysical sources in the frequency range from 10 Hz to 10 kHz. The first observation run of the Advanced LIGO detectors started in September 2015 and ended in January 2016. A strain sensitivity of better than $10^{-23}/\sqrt{\text{Hz}}$ was achieved around 100 Hz. Understanding both the fundamental and the technical noise sources was critical for increasing the observable volume in the universe. The average distance at which coalescing binary black hole systems with individual masses of 30 $M_\odot$ could be detected was 1.3 Gpc. Similarly, the range for binary neutron star inspirals was about 75 Mpc. With respect to the initial detectors, the observable volume of Universe increased respectively by a factor 69 and 43. These improvements allowed Advanced LIGO to detect the gravitational wave signal from the binary black hole coalescence, known as GW150914.
△ Less
Submitted 10 February, 2018; v1 submitted 1 April, 2016;
originally announced April 2016.
-
Calibration of the Advanced LIGO detectors for the discovery of the binary black-hole merger GW150914
Authors:
The LIGO Scientific Collaboration,
B. P. Abbott,
R. Abbott,
T. D. Abbott,
M. R. Abernathy,
K. Ackley,
C. Adams,
P. Addesso,
R. X. Adhikari,
V. B. Adya,
C. Affeldt,
N. Aggarwal,
O. D. Aguiar,
A. Ain,
P. Ajith,
B. Allen,
P. A. Altin,
D. V. Amariutei,
S. B. Anderson,
W. G. Anderson,
K. Arai,
M. C. Araya,
C. C. Arceneaux,
J. S. Areeda,
K. G. Arun
, et al. (702 additional authors not shown)
Abstract:
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detec…
▽ More
In Advanced LIGO, detection and astrophysical source parameter estimation of the binary black hole merger GW150914 requires a calibrated estimate of the gravitational-wave strain sensed by the detectors. Producing an estimate from each detector's differential arm length control loop readout signals requires applying time domain filters, which are designed from a frequency domain model of the detector's gravitational-wave response. The gravitational-wave response model is determined by the detector's opto-mechanical response and the properties of its feedback control system. The measurements used to validate the model and characterize its uncertainty are derived primarily from a dedicated photon radiation pressure actuator, with cross-checks provided by optical and radio frequency references. We describe how the gravitational-wave readout signal is calibrated into equivalent gravitational-wave-induced strain and how the statistical uncertainties and systematic errors are assessed. Detector data collected over 38 calendar days, from September 12 to October 20, 2015, contain the event GW150914 and approximately 16 of coincident data used to estimate the event false alarm probability. The calibration uncertainty is less than 10% in magnitude and 10 degrees in phase across the relevant frequency band 20 Hz to 1 kHz.
△ Less
Submitted 28 February, 2017; v1 submitted 11 February, 2016;
originally announced February 2016.
-
Seismic isolation of Advanced LIGO: Review of strategy, instrumentation and performance
Authors:
F. Matichard,
B. Lantz,
R. Mittleman,
K. Mason,
J. Kissel,
J. McIver,
B. Abbott,
R. Abbott,
S. Abbott,
E. Allwine,
S. Barnum,
J. Birch,
S. Biscans,
C. Celerier,
D. Clark,
D. Coyne,
D. DeBra,
R. DeRosa,
M. Evans,
S. Foley,
P. Fritschel,
J. A. Giaime,
C. Gray,
G. Grabeel,
J. Hanson
, et al. (27 additional authors not shown)
Abstract:
Isolating ground-based interferometric gravitational wave observatories from environmental disturbances is one of the great challenges of the advanced detector era. In order to directly observe gravitational waves, the detector components and test masses must be highly inertially decoupled from the ground motion not only to sense the faint strain of space-time induced by gravitational waves, but a…
▽ More
Isolating ground-based interferometric gravitational wave observatories from environmental disturbances is one of the great challenges of the advanced detector era. In order to directly observe gravitational waves, the detector components and test masses must be highly inertially decoupled from the ground motion not only to sense the faint strain of space-time induced by gravitational waves, but also to maintain the resonance of the very sensitive 4 km interferometers.
This article presents the seismic isolation instrumentation and strategy developed for Advanced LIGO interferometers. It reviews over a decade of research on active isolation in the context of gravitational wave detection, and presents the performance recently achieved with the Advanced LIGO observatory. Lastly, it discusses prospects for future developments in active seismic isolation and the anticipated benefits to astrophysical gravitational wave searches.
Beyond gravitational wave research, the goal of this article is to provide detailed isolation strategy guidelines for sensitive ground-based physics experiments that may benefit from similar levels of inertial isolation.
△ Less
Submitted 19 January, 2016; v1 submitted 22 February, 2015;
originally announced February 2015.
-
Advanced LIGO Two-Stage Twelve-Axis Vibration Isolation and Positioning Platform. Part 1: Design and Production Overview
Authors:
Fabrice Matichard,
Brian Lantz,
Kenneth Mason,
Richard Mittleman,
Benjamin Abbott,
Samuel Abbott,
Eric Allwine,
Samuel Barnum,
Jeremy Birch,
Sebastien Biscans,
Daniel Clark,
Dennis Coyne,
Dan DeBra,
Ryan DeRosa,
Stephany Foley,
Peter Fritschel,
Joseph A Giaime,
Corey Gray,
Gregory Grabeel,
Joe Hanson,
Michael Hillard,
Jeffrey Kissel,
Christopher Kucharczyk,
Adrien Le Roux,
Vincent Lhuillier
, et al. (15 additional authors not shown)
Abstract:
New generations of gravity wave detectors require unprecedented levels of vibration isolation. This paper presents the final design of the vibration isolation and positioning platform used in Advanced LIGO to support the interferometers core optics. This five-ton two-and-half-meter wide system operates in ultra-high vacuum. It features two stages of isolation mounted in series. The stages are imbr…
▽ More
New generations of gravity wave detectors require unprecedented levels of vibration isolation. This paper presents the final design of the vibration isolation and positioning platform used in Advanced LIGO to support the interferometers core optics. This five-ton two-and-half-meter wide system operates in ultra-high vacuum. It features two stages of isolation mounted in series. The stages are imbricated to reduce the overall height. Each stage provides isolation in all directions of translation and rotation. The system is instrumented with a unique combination of low noise relative and inertial sensors. The active control provides isolation from 0.1 Hz to 30 Hz. It brings the platform motion down to 10^(-11) m/Hz^(0.5) at 1 Hz. Active and passive isolation combine to bring the platform motion below 10^(-12) m/Hz^(0.5) at 10 Hz. The passive isolation lowers the motion below 10^(-13) m/Hz^(0.5) at 100 Hz. The paper describes how the platform has been engineered not only to meet the isolation requirements, but also to permit the construction, testing, and commissioning process of the fifteen units needed for Advanced LIGO observatories.
△ Less
Submitted 23 July, 2014;
originally announced July 2014.
-
Advanced LIGO Two-Stage Twelve-Axis Vibration Isolation and Positioning Platform. Part 2: Experimental Investigation and Tests Results
Authors:
Fabrice Matichard,
Brian Lantz,
Kenneth Mason,
Richard Mittleman,
Benjamin Abbott,
Samuel Abbott,
Eric Allwine,
Samuel Barnum,
Jeremy Birch,
Sebastien Biscans,
Daniel Clark,
Dennis Coyne,
Dan DeBra,
Ryan DeRosa,
Stephany Foley,
Peter Fritschel,
Joseph A Giaime,
Corey Gray,
Gregory Grabeel,
Joe Hanson,
Michael Hillard,
Jeffrey Kissel,
Christopher Kucharczyk,
Adrien Le Roux,
Vincent Lhuillier
, et al. (15 additional authors not shown)
Abstract:
This paper presents the results of the past seven years of experimental investigation and testing done on the two-stage twelve-axis vibration isolation platform for Advanced LIGO gravity waves observatories. This five-ton two-and-half-meter wide system supports more than a 1000 kg of very sensitive equipment. It provides positioning capability and seismic isolation in all directions of translation…
▽ More
This paper presents the results of the past seven years of experimental investigation and testing done on the two-stage twelve-axis vibration isolation platform for Advanced LIGO gravity waves observatories. This five-ton two-and-half-meter wide system supports more than a 1000 kg of very sensitive equipment. It provides positioning capability and seismic isolation in all directions of translation and rotation. To meet the very stringent requirements of Advanced LIGO, the system must provide more than three orders of magnitude of isolation over a very large bandwidth. It must bring the motion below 10^(-11) m/(Hz)^0.5 at 1 Hz and 10^(-12) m/(Hz)^0.5 at 10 Hz. A prototype of this system has been built in 2006. It has been extensively tested and analyzed during the following two years. This paper shows how the experimental results obtained with the prototype were used to engineer the final design. It highlights how the engineering solutions implemented not only improved the isolation performance but also greatly simplified the assembly, testing, and commissioning process. During the past two years, five units have been constructed, tested, installed and commissioned at each of the two LIGO observatories. Five other units are being built for an upcoming third observatory. The test results presented show that the system meets the motion requirements, and reach the sensor noise in the control bandwidth.
△ Less
Submitted 23 July, 2014;
originally announced July 2014.