Laser cooling of positronium
Authors:
K. Shu,
Y. Tajima,
R. Uozumi,
N. Miyamoto,
S. Shiraishi,
T. Kobayashi,
A. Ishida,
K. Yamada,
R. W. Gladen,
T. Namba,
S. Asai,
K. Wada,
I. Mochizuki,
T. Hyodo,
K. Ito,
K. Michishio,
B. E. O'Rourke,
N. Oshima,
K. Yoshioka
Abstract:
When laser radiation is skilfully applied, atoms and molecules can be cooled allowing precise measurements and control of quantum systems. This is essential in fundamental studies of physics as well as practical applications such as precision spectroscopy, quantum-statistical-property manifesting ultracold gases, and quantum computing. In laser cooling, repeated cycles of laser photon absorption a…
▽ More
When laser radiation is skilfully applied, atoms and molecules can be cooled allowing precise measurements and control of quantum systems. This is essential in fundamental studies of physics as well as practical applications such as precision spectroscopy, quantum-statistical-property manifesting ultracold gases, and quantum computing. In laser cooling, repeated cycles of laser photon absorption and direction-independent spontaneous emission can slow atoms and molecules to otherwise unattainable velocities. Simple systems can provide a rigorous testing ground for fundamental theories of physics; one such system is the purely leptonic positronium, an exotic atom of an electron and its antiparticle, the positron. However, the cooling of positronium has hitherto remained unrealised. Here, we demonstrate laser cooling of positronium. A novel laser system of a train of broadband pulses with successively increasing central frequencies was used to overcome major challenges presented by the short lifetime of positronium and the significant Doppler broadening and recoil as a consequence of its very light mass. One-dimensional chirp cooling of the dilute positronium gas in a counter-propagating configuration gave a final velocity distribution corresponding to approximately 1 K in a short time of 100 ns. This study on a pure leptonic system is a major step in the field of low-temperature fundamental physics of antimatter, and is complementary to the laser cooling of antihydrogen, a hadron-containing exotic atom. Progress in this field is vital in elucidating the origin of the matter-antimatter asymmetry in the universe. The application of laser cooling to positronium may afford a unique opportunity to rigorously test bound-state quantum electrodynamics. Moreover, laser cooling of positronium is key to the realisation of Bose-Einstein condensation in this matter-antimatter system.
△ Less
Submitted 15 October, 2023; v1 submitted 12 October, 2023;
originally announced October 2023.
Measurement of Dispersion of a Clinical Proton Therapy Beam
Authors:
Satomi Shiraishi,
Michael G. Herman,
Keith M. Furutani
Abstract:
Purpose: To measure dispersion of a clinical proton therapy beam.
Methods and Materials: The proton center at our institution uses a Hitachi PROBEAT V synchrotron that delivers beams with energies ranging from 70 to 230 MeV to five treatment rooms, four of which have gantries and one fixed beam. For this study, the magnetic field strengths of all optics in the transport line were varied to measu…
▽ More
Purpose: To measure dispersion of a clinical proton therapy beam.
Methods and Materials: The proton center at our institution uses a Hitachi PROBEAT V synchrotron that delivers beams with energies ranging from 70 to 230 MeV to five treatment rooms, four of which have gantries and one fixed beam. For this study, the magnetic field strengths of all optics in the transport line were varied to measure the dispersion of 230 MeV beams in each of the four gantry rooms. Beam position was measured using the Spot Position Monitor (SPM), a multi-wire proportional counter (MWPC) in the nozzle approximately 0.5 meters upstream of the treatment isocenter. Measured beam positions as a function of momentum offset were fitted to a linear function to extract dispersion. In one gantry, dispersions for 70 and 140 MeV beams were also measured. Because spot position is continuously monitored during treatments and a position deviation will abort the beam delivery, the dispersion at the spot position monitor was used to set an upper limit of range uncertainty originating from momentum deviation. When dispersion was approximately zero, dose rate measurements were used to set an upper limit of momentum deviation that could reach the patient.
Results: Dispersion was 0.45 m, 0.48 m and 0.30 m for 70 MeV, 140 MeV, and 230 MeV beams in a gantry, respectively, corresponding to 0.3 mm, 1.0 mm and 3.5 mm maximum range uncertainty during treatments. For 230 MeV beams, dispersion ranged from 0 to 0.73 m across the four gantries, corresponding to the upper limits of range uncertainty due to momentum deviation of 1.4 to 6.2 mm (0.4 to 1.9% in fractional range uncertainty).
Conclusions: The measured dispersion was both energy- and gantry-dependent and ranged from 0 to 0.73 m.
△ Less
Submitted 30 April, 2018;
originally announced May 2018.