-
Phase and contrast moiré signatures in two-dimensional cone beam interferometry
Authors:
D. Sarenac,
G. Gorbet,
Charles W. Clark,
D. G. Cory,
H. Ekinci,
M. E. Henderson,
M. G. Huber,
D. Hussey,
C. Kapahi,
P. A. Kienzle,
Y. Kim,
M. A. Long,
J. D. Parker,
T. Shinohara,
F. Song,
D. A. Pushin
Abstract:
Neutron interferometry has played a distinctive role in fundamental science and characterization of materials. Moiré neutron interferometers are candidate next-generation instruments: they offer microscopy-like magnification of the signal, enabling direct camera recording of interference patterns across the full neutron wavelength spectrum. Here we demonstrate the extension of phase-grating moiré…
▽ More
Neutron interferometry has played a distinctive role in fundamental science and characterization of materials. Moiré neutron interferometers are candidate next-generation instruments: they offer microscopy-like magnification of the signal, enabling direct camera recording of interference patterns across the full neutron wavelength spectrum. Here we demonstrate the extension of phase-grating moiré interferometry to two-dimensional geometries. Our fork-dislocation phase gratings reveal phase singularities in the moiré pattern, and we explore orthogonal moiré patterns with two-dimensional phase-gratings. Our measurements of phase topologies and gravitationally induced phase shifts are in good agreement with theory. These techniques can be implemented in existing neutron instruments to advance interferometric analyses of emerging materials and precision measurements of fundamental constants.
△ Less
Submitted 3 November, 2023;
originally announced November 2023.
-
Cone beam neutron interferometry: from modeling to applications
Authors:
D. Sarenac,
G. Gorbet,
C. Kapahi,
Charles W. Clark,
D. G. Cory,
H. Ekinci,
S. Fangzhou,
M. E. Henderson,
M. G. Huber,
D. Hussey,
P. A. Kienzle,
R. Serrat,
J. D. Parker,
T. Shinohara,
D. A. Pushin
Abstract:
Phase-grating moire interferometers (PGMIs) have emerged as promising candidates for the next generation of neutron interferometry, enabling the use of a polychromatic beam and manifesting interference patterns that can be directly imaged by existing neutron cameras. However, the modeling of the various PGMI configurations is limited to cumbersome numerical calculations and backward propagation mo…
▽ More
Phase-grating moire interferometers (PGMIs) have emerged as promising candidates for the next generation of neutron interferometry, enabling the use of a polychromatic beam and manifesting interference patterns that can be directly imaged by existing neutron cameras. However, the modeling of the various PGMI configurations is limited to cumbersome numerical calculations and backward propagation models which often do not enable one to explore the setup parameters. Here we generalize the Fresnel scaling theorem to introduce a k-space model for PGMI setups illuminated by a cone beam, thus enabling an intuitive forward propagation model for a wide range of parameters. The interference manifested by a PGMI is shown to be a special case of the Talbot effect, and the optimal fringe visibility is shown to occur at the moire location of the Talbot distances. We derive analytical expressions for the contrast and the propagating intensity profiles in various conditions, and analyze the behaviour of the dark-field imaging signal when considering sample characterization. The model's predictions are compared to experimental measurements and good agreement is found between them. Lastly, we propose and experimentally verify a method to recover contrast at typically inaccessible PGMI autocorrelation lengths. The presented work provides a toolbox for analyzing and understanding existing PGMI setups and their future applications, for example extensions to two-dimensional PGMIs and characterization of samples with non-trivial structures.
△ Less
Submitted 4 September, 2023;
originally announced September 2023.
-
The Brain Tumor Segmentation (BraTS) Challenge 2023: Glioma Segmentation in Sub-Saharan Africa Patient Population (BraTS-Africa)
Authors:
Maruf Adewole,
Jeffrey D. Rudie,
Anu Gbadamosi,
Oluyemisi Toyobo,
Confidence Raymond,
Dong Zhang,
Olubukola Omidiji,
Rachel Akinola,
Mohammad Abba Suwaid,
Adaobi Emegoakor,
Nancy Ojo,
Kenneth Aguh,
Chinasa Kalaiwo,
Gabriel Babatunde,
Afolabi Ogunleye,
Yewande Gbadamosi,
Kator Iorpagher,
Evan Calabrese,
Mariam Aboian,
Marius Linguraru,
Jake Albrecht,
Benedikt Wiestler,
Florian Kofler,
Anastasia Janas,
Dominic LaBella
, et al. (26 additional authors not shown)
Abstract:
Gliomas are the most common type of primary brain tumors. Although gliomas are relatively rare, they are among the deadliest types of cancer, with a survival rate of less than 2 years after diagnosis. Gliomas are challenging to diagnose, hard to treat and inherently resistant to conventional therapy. Years of extensive research to improve diagnosis and treatment of gliomas have decreased mortality…
▽ More
Gliomas are the most common type of primary brain tumors. Although gliomas are relatively rare, they are among the deadliest types of cancer, with a survival rate of less than 2 years after diagnosis. Gliomas are challenging to diagnose, hard to treat and inherently resistant to conventional therapy. Years of extensive research to improve diagnosis and treatment of gliomas have decreased mortality rates across the Global North, while chances of survival among individuals in low- and middle-income countries (LMICs) remain unchanged and are significantly worse in Sub-Saharan Africa (SSA) populations. Long-term survival with glioma is associated with the identification of appropriate pathological features on brain MRI and confirmation by histopathology. Since 2012, the Brain Tumor Segmentation (BraTS) Challenge have evaluated state-of-the-art machine learning methods to detect, characterize, and classify gliomas. However, it is unclear if the state-of-the-art methods can be widely implemented in SSA given the extensive use of lower-quality MRI technology, which produces poor image contrast and resolution and more importantly, the propensity for late presentation of disease at advanced stages as well as the unique characteristics of gliomas in SSA (i.e., suspected higher rates of gliomatosis cerebri). Thus, the BraTS-Africa Challenge provides a unique opportunity to include brain MRI glioma cases from SSA in global efforts through the BraTS Challenge to develop and evaluate computer-aided-diagnostic (CAD) methods for the detection and characterization of glioma in resource-limited settings, where the potential for CAD tools to transform healthcare are more likely.
△ Less
Submitted 30 May, 2023;
originally announced May 2023.
-
Development and application of a $^3$He Neutron Spin Filter at J-PARC
Authors:
T. Okudaira,
T. Oku,
T. Ino,
H. Hayashida,
H. Kira,
K. Sakai,
K. Hiroi,
S. Takahashi,
K. Aizawa,
H. Endo,
S. Endo,
M. Hino,
K. Hirota,
T. Honda,
K. Ikeda,
K. Kakurai,
W. Kambara,
M. Kitaguchi,
T. Oda,
H. Ohshita,
T. Otomo,
H. M. Shimizu,
T. Shinohara,
J. Suzuki,
T. Yamamoto
Abstract:
We are develo** a neutron polarizer with polarized $^3$He gas, referred to as a $^3$He spin filter, based on the Spin Exchange Optical Pum** (SEOP) for polarized neutron scattering experiments at Materials and Life Science Experimental Facility (MLF) of Japan Proton Accelerator Research Complex (J-PARC). A $^3$He gas-filling station was constructed at J-PARC, and several $^3$He cells with long…
▽ More
We are develo** a neutron polarizer with polarized $^3$He gas, referred to as a $^3$He spin filter, based on the Spin Exchange Optical Pum** (SEOP) for polarized neutron scattering experiments at Materials and Life Science Experimental Facility (MLF) of Japan Proton Accelerator Research Complex (J-PARC). A $^3$He gas-filling station was constructed at J-PARC, and several $^3$He cells with long spin relaxation times have been fabricated using the gas-filling station. A laboratory has been prepared in the MLF beam hall for polarizing $^3$He cells, and compact pum** systems with laser powers of 30~W and 110~W, which can be installed onto a neutron beamline, have been developed. A $^3$He polarization of 85% was achieved at a neutron beamline by using the pum** system with the 110~W laser. Recently, the first user experiment utilizing the $^3$He spin filter was conducted, and there have been several more since then. The development and utilization of $^3$He spin filters at MLF of J-PARC are reported.
△ Less
Submitted 29 May, 2020;
originally announced May 2020.
-
Tomographic Reconstruction of Triaxial Strain Fields from Bragg-Edge Neutron Imaging
Authors:
J. N. Hendriks,
A. W. T. Gregg,
R. R. Jackson,
C. M. Wensrich,
A. Wills,
A. S. Tremsin,
T. Shinohara,
V. Luzin,
O. Kirstein
Abstract:
This paper presents a proof-of-concept demonstration of triaxial strain tomography from Bragg-edge neutron imaging within a three-dimensional sample. Bragg-edge neutron transmission can provide high-resolution images of the average through thickness strain within a polycrystalline material. This poses an associated rich tomography problem which seeks to reconstruct the full triaxial strain field f…
▽ More
This paper presents a proof-of-concept demonstration of triaxial strain tomography from Bragg-edge neutron imaging within a three-dimensional sample. Bragg-edge neutron transmission can provide high-resolution images of the average through thickness strain within a polycrystalline material. This poses an associated rich tomography problem which seeks to reconstruct the full triaxial strain field from these images. The presented demonstration is an important step towards solving this problem, and towards a technique capable of studying the residual strain and stress within engineering components. A Gaussian process based approach is used that ensures the reconstruction satisfies equilibrium and known boundary conditions. This approach is demonstrated experimentally on a non-trivial steel sample with use of the RADEN instrument at the Japan Proton Accelerator Research Complex. Validation of the reconstruction is provided by comparison with conventional strain scans from the KOWARI constant-wavelength strain diffractometer at the Australian Nuclear Science and Technology Organisation and simulations via finite element analysis.
△ Less
Submitted 28 November, 2019; v1 submitted 20 June, 2019;
originally announced June 2019.
-
Tomographic Reconstruction of Two-Dimensional Residual Strain Fields from Bragg-Edge Neutron Imaging
Authors:
Alexander Gregg,
Johannes Hendriks,
Christopher Wensrich,
Adrian Wills,
Anton Tremsin,
Vladimir Luzin,
Takenao Shinohara,
Oliver Kirstein,
Michael Meylan,
Erich Kisi
Abstract:
Bragg-edge strain imaging from energy-resolved neutron transmission measurements poses an interesting tomography problem. The solution to this problem will allow the reconstruction of detailed triaxial stress and strain distributions within polycrystalline solids from sets of Bragg-edge strain images. Work over the last decade has provided some solutions for a limited number of special cases. In t…
▽ More
Bragg-edge strain imaging from energy-resolved neutron transmission measurements poses an interesting tomography problem. The solution to this problem will allow the reconstruction of detailed triaxial stress and strain distributions within polycrystalline solids from sets of Bragg-edge strain images. Work over the last decade has provided some solutions for a limited number of special cases. In this paper, we provide a general approach to reconstruction of an arbitrary system based on a least squares process constrained by equilibrium. This approach is developed in two- dimensions before being demonstrated experimentally on two samples using the RADEN instrument at the J-PARC spallation neutron source in Japan. Validation of the resulting reconstructions is provided through a comparison to conventional constant wavelength strain measurements carried out on the KOWARI engineering diffractometer within ANSTO in Australia. The paper concludes with a discussion on the range of problems to be addressed in a three-dimensional implementation.
△ Less
Submitted 19 August, 2018;
originally announced August 2018.
-
Development of energy-resolved neutron imaging detectors at RADEN
Authors:
Joseph Don Parker,
Masahide Harada,
Hirotoshi Hayashida,
Kosuke Hiroi,
Tetsuya Kai,
Yoshihiro Matsumoto,
Takeshi Nakatani,
Kenichi Oikawa,
Mariko Segawa,
Takenao Shinohara,
Yuhua Su,
Atsushi Takada,
Taito Takemura,
Tomoyuki Taniguchi,
Toru Tanimori,
Yoshiaki Kiyanagi
Abstract:
Energy-resolved neutron imaging at a pulsed source utilizes the energy-dependent neutron transmission measured via time-of-flight to extract quantitative information about the internal microstructure of an object. At the RADEN instrument at J-PARC in Japan, we use cutting-edge detectors employing micro-pattern detectors or fast Li-glass scintillators and fast, all-digital data acquisition to perfo…
▽ More
Energy-resolved neutron imaging at a pulsed source utilizes the energy-dependent neutron transmission measured via time-of-flight to extract quantitative information about the internal microstructure of an object. At the RADEN instrument at J-PARC in Japan, we use cutting-edge detectors employing micro-pattern detectors or fast Li-glass scintillators and fast, all-digital data acquisition to perform such measurements, while continuing their development toward better utilization of the intense neutron source. In particular, for the Micro-Pixel Chamber based Neutron Imaging Detector (μNID), a micro-pattern detector with a 400 μm pitch and employing 3He for neutron conversion, we have successfully improved the spatial resolution from 200 to 100 μm, increased the detection efficiency from 18 to 26% for thermal neutrons, and increased the maximum count rate from 0.4 to 1 Mcps. We are also testing a new readout element with a 215 μm pitch for further improved spatial resolution, and a μNID with boron-based neutron converter for increased rate performance.
△ Less
Submitted 25 June, 2018;
originally announced June 2018.
-
Bragg-Edge Elastic Strain Tomography for in situ Systems from Energy-Resolved Neutron Transmission Imaging
Authors:
J. N. Hendriks,
A. W. T. Gregg,
C. M. Wensrich,
A. S. Tremsin,
T. Shinohara,
M. Meylan,
E. H. Kisi,
V. Luzin,
O. Kirsten
Abstract:
Technological developments in high resolution time-of-flight neutron detectors have raised the prospect of tomographic reconstruction of elastic strain fields from Bragg-edge strain images. This approach holds the potential to provide a unique window into the full triaxial stress field within solid samples. While general tomographic reconstruction from these images has been shown to be ill-posed,…
▽ More
Technological developments in high resolution time-of-flight neutron detectors have raised the prospect of tomographic reconstruction of elastic strain fields from Bragg-edge strain images. This approach holds the potential to provide a unique window into the full triaxial stress field within solid samples. While general tomographic reconstruction from these images has been shown to be ill-posed, an injective link between measurements and boundary deformations exists for systems subject to in situ applied loads in the absence of residual stress. Recent work has provided an algorithm to achieve tomographic reconstruction for this class of mechanical system. This letter details an experimental proof-of-concept for this algorithm involving the full reconstruction of a biaxial strain field within a non-trivial steel sample. This work was carried out on the RADEN energy resolved neutron imaging instrument within the Japan Proton Accelerator Research Complex, with validation through Digital Image Correlation and constant wavelength neutron strain scans.
△ Less
Submitted 7 July, 2019; v1 submitted 11 August, 2017;
originally announced August 2017.
-
Time-of-Flight Three Dimensional Neutron Diffraction in Transmission Mode for Map** Crystal Grain Structures
Authors:
Alberto Cereser,
Markus Strobl,
Stephen Hall,
Axel Steuwer,
Ryoji Kiyanagi,
Anton Tremsin,
Erik Bergbäck Knudsen,
Takenao Shinohara,
Peter Willendrup,
Alice Bastos da Silva Fanta,
Srinivasan Iyengar,
Peter Mahler Larsen,
Takayasu Hanashima,
Taketo Moyoshi,
Peter M. Kadletz,
Philip Krooß,
Thomas Niendorf,
Morten Sales,
Wolfgang W. Schmahl,
Søren Schmidt
Abstract:
The physical properties of polycrystalline materials depend on their microstructure, which is the nano-to-centimeter-scale arrangement of phases and defects in their interior. Such microstructure depends on the shape, crystallographic phase and orientation, and interfacing of the grains constituting the material. This article presents a new non-destructive 3D technique to study bulk samples with s…
▽ More
The physical properties of polycrystalline materials depend on their microstructure, which is the nano-to-centimeter-scale arrangement of phases and defects in their interior. Such microstructure depends on the shape, crystallographic phase and orientation, and interfacing of the grains constituting the material. This article presents a new non-destructive 3D technique to study bulk samples with sizes in the cm range with a resolution of hundred micrometers: time-of-flight three-dimensional neutron diffraction (ToF 3DND). Compared to existing analogous X-ray diffraction techniques, ToF 3DND enables studies of samples that can be both larger in size and made of heavier elements. Moreover, ToF 3DND facilitates the use of complicated sample environments. The basic ToF 3DND setup, utilizing an imaging detector with high spatial and temporal resolution, can easily be implemented at a time-of-flight neutron beamline. The technique was developed and tested with data collected at the Materials and Life Science Experimental Facility of the Japan Proton Accelerator Complex (J-PARC) for an iron sample. We successfully reconstructed the shape of 108 grains and developed an indexing procedure. The reconstruction algorithms have been validated by reconstructing two stacked Co-Ni-Ga single crystals and by comparison with a grain map obtained by post-mortem electron backscatter diffraction (EBSD).
△ Less
Submitted 20 April, 2017;
originally announced April 2017.
-
Three Dimensional Polarimetric Neutron Tomography of Magnetic Fields
Authors:
Morten Sales,
Markus Strobl,
Takenao Shinohara,
Anton Tremsin,
Luise Theil Kuhn,
William R. B. Lionheart,
Naeem M. Desai,
Anders Bjorholm Dahl,
Søren Schmidt
Abstract:
Through the use of Time-of-Flight Three Dimensional Polarimetric Neutron Tomography (ToF 3DPNT) we have for the first time successfully demonstrated a technique capable of measuring and reconstructing three dimensional magnetic field strengths and directions unobtrusively and non-destructively with the potential to probe the interior of bulk samples which is not amenable otherwise.
Using a pione…
▽ More
Through the use of Time-of-Flight Three Dimensional Polarimetric Neutron Tomography (ToF 3DPNT) we have for the first time successfully demonstrated a technique capable of measuring and reconstructing three dimensional magnetic field strengths and directions unobtrusively and non-destructively with the potential to probe the interior of bulk samples which is not amenable otherwise.
Using a pioneering polarimetric set-up for ToF neutron instrumentation in combination with a newly developed tailored reconstruction algorithm, the magnetic field generated by a current carrying solenoid has been measured and reconstructed, thereby providing the proof-of-principle of a technique able to reveal hitherto unobtainable information on the magnetic fields in the bulk of materials and devices, due to a high degree of penetration into many materials, including metals, and the sensitivity of neutron polarisation to magnetic fields. The technique puts the potential of the ToF time structure of pulsed neutron sources to full use in order to optimise the recorded information quality and reduce measurement time.
△ Less
Submitted 2 February, 2018; v1 submitted 17 April, 2017;
originally announced April 2017.
-
Broadband Neutron Interferometer
Authors:
Dmitry A. Pushin,
Dusan Sarenac,
Dan Hussey,
Houxun Miao,
Muhammad Arif,
David G. Cory,
Michael G. Huber,
David Jacobson,
Jacob LaManna,
Joseph D. Parker,
Taken Shinohara,
Wakana Ueno,
Han Wen
Abstract:
We demonstrate a two phase-grating, multi-beam neutron interferometer by using a modified Ronchi setup in a far-field regime. The functionality of the interferometer is based on the universal \moire effect that was recently implemented for X-ray phase-contrast imaging in the far-field regime. Interference fringes were achieved with monochromatic, bichromatic, and polychromatic neutron beams; for b…
▽ More
We demonstrate a two phase-grating, multi-beam neutron interferometer by using a modified Ronchi setup in a far-field regime. The functionality of the interferometer is based on the universal \moire effect that was recently implemented for X-ray phase-contrast imaging in the far-field regime. Interference fringes were achieved with monochromatic, bichromatic, and polychromatic neutron beams; for both continuous and pulsed beams. This far-field neutron interferometry allows for the utilization of the full neutron flux for precise measurements of potential gradients, and expands neutron phase-contrast imaging techniques to more intense polycromatic neutron beams.
△ Less
Submitted 9 June, 2016;
originally announced June 2016.
-
Development of a Time-resolved Neutron Imaging Detector Based on the μPIC Micro-Pixel Chamber
Authors:
Joseph D Parker,
Masahide Harada,
Kaori Hattori,
Satoru Iwaki,
Shigeto Kabuki,
Yuji Kishimoto,
Hidetoshi Kubo,
Shunsuke Kurosawa,
Yoshihiro Matsuoka,
Kentaro Miuchi,
Tetsuya Mizumoto,
Hironobu Nishimura,
Takayuki Oku,
Tatsuya Sawano,
Takenao Shinohara,
Jun-ichi Suzuki,
Atsushi Takada,
Toru Tanimori,
Kazuki Ueno,
Masahiro Ikeno,
Manobu Tanaka,
Tomohisa Uchida
Abstract:
We have developed a prototype time-resolved neutron imaging detector employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data acquisition system. Our detector system combines 100μm-level spatial and sub-μs time resolutions with a low gamma sensitivity of less than 10^-12 and high data rates, making it well suited for…
▽ More
We have developed a prototype time-resolved neutron imaging detector employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data acquisition system. Our detector system combines 100μm-level spatial and sub-μs time resolutions with a low gamma sensitivity of less than 10^-12 and high data rates, making it well suited for applications in neutron radiography at high-intensity, pulsed neutron sources. In the present paper, we introduce the detector system and present several test measurements performed at NOBORU (BL10), J-PARC to demonstrate the capabilities of our prototype. We also discuss future improvements to the spatial resolution and rate performance.
△ Less
Submitted 20 May, 2013;
originally announced May 2013.
-
Spatial resolution of a μPIC-based neutron imaging detector
Authors:
Joseph D. Parker,
Masahide Harada,
Kaori Hattori,
Satoru Iwaki,
Shigeto Kabuki,
Yuji Kishimoto,
Hidetoshi Kubo,
Shunsuke Kurosawa,
Yoshihiro Matsuoka,
Kentaro Miuchi,
Tetsuya Mizumoto,
Hironobu Nishimura,
Takayuki Oku,
Tatsuya Sawano,
Takenao Shinohara,
Jun-ichi Suzuki,
Atsushi Takada,
Toru Tanimori,
Kazuki Ueno
Abstract:
We present a detailed study of the spatial resolution of our time-resolved neutron imaging detector utilizing a new neutron position reconstruction method that improves both spatial resolution and event reconstruction efficiency. Our prototype detector system, employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data…
▽ More
We present a detailed study of the spatial resolution of our time-resolved neutron imaging detector utilizing a new neutron position reconstruction method that improves both spatial resolution and event reconstruction efficiency. Our prototype detector system, employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data acquisition system, combines 100μm-level spatial and sub-μs time resolutions with excellent gamma rejection and high data rates, making it well suited for applications in neutron radiography at high-intensity, pulsed neutron sources. From data taken at the Materials and Life Science Experimental Facility within the Japan Proton Accelerator Research Complex (J-PARC), the spatial resolution was found to be approximately Gaussian with a sigma of 103.48 +/- 0.77 μm (after correcting for beam divergence). This is a significant improvement over that achievable with our previous reconstruction method (334 +/- 13 μm), and compares well with conventional neutron imaging detectors and with other high-rate detectors currently under development. Further, a detector simulation indicates that a spatial resolution of less than 60 μm may be possible with optimization of the gas characteristics and μPIC structure. We also present an example of imaging combined with neutron resonance absorption spectroscopy.
△ Less
Submitted 16 May, 2013;
originally announced May 2013.
-
Neutron imaging detector based on the muPIC micro-pixel chamber
Authors:
J. D. Parker,
K. Hattori,
H. Fujioka,
M. Harada,
S. Iwaki,
S. Kabuki,
Y. Kishimoto,
H. Kubo,
S. Kurosawa,
K. Miuchi,
T. Nagae,
H. Nishimura,
T. Oku,
T. Sawano,
T. Shinohara,
J. Suzuki,
A. Takada,
T. Tanimori,
K. Ueno
Abstract:
We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in neutron radiography at high-intensity neutron sources. The prototype system, with an active area of 10cm x 10cm and operated at a gas pressure of 2 atm, measur…
▽ More
We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in neutron radiography at high-intensity neutron sources. The prototype system, with an active area of 10cm x 10cm and operated at a gas pressure of 2 atm, measures both the energy deposition (via time-over-threshold) and 3-dimensional track of each neutron-induced event, allowing the reconstruction of the neutron interaction point with improved accuracy. Using a simple position reconstruction algorithm, a spatial resolution of 349 +/- 36 microns was achieved, with further improvement expected. The detailed tracking allows strong rejection of background gamma-rays, resulting in an effective gamma sensitivity of 10^-12 or less, coupled with stable, robust neutron identification. The detector also features a time resolution of 0.6 microseconds.
△ Less
Submitted 26 September, 2012;
originally announced September 2012.