-
Electromagnetically induced transparency based Rydberg-atom sensor for quantum voltage measurements
Authors:
Christopher L. Holloway,
Nikunjkumar Prajapati,
John Kitching,
Jeffery A. Sherman,
Carson Teale,
Alain Rufenacht,
Alexandra B. Artusio-Glimpse,
Matthew T. Simons,
Amy K. Robinson,
Eric B. Norrgard
Abstract:
We investigate the Stark shift in Rydberg rubidium atoms through electromagnetically induced transparency for the measurement of direct current (dc) and 60~Hz alternating current (ac) voltages. This technique has direct applications to atom-based measurements of dc and ac voltage and the calibration of voltage instrumentation. We present experimental results for different atomic states that allow…
▽ More
We investigate the Stark shift in Rydberg rubidium atoms through electromagnetically induced transparency for the measurement of direct current (dc) and 60~Hz alternating current (ac) voltages. This technique has direct applications to atom-based measurements of dc and ac voltage and the calibration of voltage instrumentation. We present experimental results for different atomic states that allow for dc and ac voltage measurements ranging from 0~V to 12~V. A Rydberg atom-based voltage standard could become an alternative calibration method with more favorable size, weight, power consumption, and cost compared to the more precise Josephson voltage standard. In this study, we also demonstrate how the voltage measurements can be utilized to determine the atomic polarizability for the Rydberg states. The Rydberg atom-based voltage measurement technology would become a complimentary method for dissemination of the voltage scale directly to the end user.
△ Less
Submitted 22 October, 2021; v1 submitted 5 October, 2021;
originally announced October 2021.
-
Optical Atomic Clock Comparison through Turbulent Air
Authors:
Martha I. Bodine,
Jean-Daniel Deschênes,
Isaac H. Khader,
William C. Swann,
Holly Leopardi,
Kyle Beloy,
Tobias Bothwell,
Samuel M. Brewer,
Sarah L. Bromley,
Jwo-Sy Chen,
Scott A. Diddams,
Robert J. Fasano,
Tara M. Fortier,
Youssef S. Hassan,
David B. Hume,
Dhruv Kedar,
Colin J. Kennedy,
Amanda Koepke,
David R. Leibrandt,
Andrew D. Ludlow,
William F. McGrew,
William R. Milner,
Daniele Nicolodi,
Eric Oelker,
Thomas E. Parker
, et al. (10 additional authors not shown)
Abstract:
We use frequency comb-based optical two-way time-frequency transfer (O-TWTFT) to measure the optical frequency ratio of state-of-the-art ytterbium and strontium optical atomic clocks separated by a 1.5 km open-air link. Our free-space measurement is compared to a simultaneous measurement acquired via a noise-cancelled fiber link. Despite non-stationary, ps-level time-of-flight variations in the fr…
▽ More
We use frequency comb-based optical two-way time-frequency transfer (O-TWTFT) to measure the optical frequency ratio of state-of-the-art ytterbium and strontium optical atomic clocks separated by a 1.5 km open-air link. Our free-space measurement is compared to a simultaneous measurement acquired via a noise-cancelled fiber link. Despite non-stationary, ps-level time-of-flight variations in the free-space link, ratio measurements obtained from the two links, averaged over 30.5 hours across six days, agree to $6\times10^{-19}$, showing that O-TWTFT can support free-space atomic clock comparisons below the $10^{-18}$ level.
△ Less
Submitted 11 September, 2020; v1 submitted 1 June, 2020;
originally announced June 2020.
-
Frequency Ratio Measurements with 18-digit Accuracy Using a Network of Optical Clocks
Authors:
Boulder Atomic Clock Optical Network,
Collaboration,
:,
Kyle Beloy,
Martha I. Bodine,
Tobias Bothwell,
Samuel M. Brewer,
Sarah L. Bromley,
Jwo-Sy Chen,
Jean-Daniel Deschênes,
Scott A. Diddams,
Robert J. Fasano,
Tara M. Fortier,
Youssef S. Hassan,
David B. Hume,
Dhruv Kedar,
Colin J. Kennedy,
Isaac Khader,
Amanda Koepke,
David R. Leibrandt,
Holly Leopardi,
Andrew D. Ludlow,
William F. McGrew,
William R. Milner,
Nathan R. Newbury
, et al. (13 additional authors not shown)
Abstract:
Atomic clocks occupy a unique position in measurement science, exhibiting higher accuracy than any other measurement standard and underpinning six out of seven base units in the SI system. By exploiting higher resonance frequencies, optical atomic clocks now achieve greater stability and lower frequency uncertainty than existing primary standards. Here, we report frequency ratios of the $^{27}$Al…
▽ More
Atomic clocks occupy a unique position in measurement science, exhibiting higher accuracy than any other measurement standard and underpinning six out of seven base units in the SI system. By exploiting higher resonance frequencies, optical atomic clocks now achieve greater stability and lower frequency uncertainty than existing primary standards. Here, we report frequency ratios of the $^{27}$Al$^+$, $^{171}$Yb and $^{87}$Sr optical clocks in Boulder, Colorado, measured across an optical network spanned by both fiber and free-space links. These ratios have been evaluated with measurement uncertainties between $6\times10^{-18}$ and $8\times10^{-18}$, making them the most accurate reported measurements of frequency ratios to date. This represents a critical step towards redefinition of the SI second and future applications such as relativistic geodesy and tests of fundamental physics.
△ Less
Submitted 29 May, 2020;
originally announced May 2020.
-
Coherent Optical Clock Down-Conversion for Microwave Frequencies with 10-18 Instability
Authors:
Takuma Nakamura,
Josue Davila-Rodriguez,
Holly Leopardi,
Jeff A. Sherman,
Tara M. Fortier,
Xiaojun Xie,
Joe C. Campbell,
William F. McGrew,
Xiaogang Zhang,
Youssef S. Hassan,
Daniele Nicolodi,
Kyle Beloy,
Andrew D. Ludlow,
Scott A. Diddams,
Franklyn Quinlan
Abstract:
Optical atomic clocks are poised to redefine the SI second, thanks to stability and accuracy more than one hundred times better than the current microwave atomic clock standard. However, the best optical clocks have not seen their performance transferred to the electronic domain, where radar, navigation, communications, and fundamental research rely on less stable microwave sources. By comparing t…
▽ More
Optical atomic clocks are poised to redefine the SI second, thanks to stability and accuracy more than one hundred times better than the current microwave atomic clock standard. However, the best optical clocks have not seen their performance transferred to the electronic domain, where radar, navigation, communications, and fundamental research rely on less stable microwave sources. By comparing two independent optical-to-electronic signal generators, we demonstrate a 10 GHz microwave signal with phase that exactly tracks that of the optical clock phase from which it is derived, yielding an absolute fractional frequency instability of 1*10-18 in the electronic domain. Such faithful reproduction of the optical clock phase expands the opportunities for optical clocks both technologically and scientifically for time-dissemination, navigation, and long-baseline interferometric imaging.
△ Less
Submitted 9 March, 2020; v1 submitted 5 March, 2020;
originally announced March 2020.
-
Demonstration of a time scale based on a stable optical carrier
Authors:
William R. Milner,
John M. Robinson,
Colin J. Kennedy,
Tobias Bothwell,
Dhruv Kedar,
Dan G. Matei,
Thomas Legero,
Uwe Sterr,
Fritz Riehle,
Holly Leopardi,
Tara M. Fortier,
Jeffrey A. Sherman,
Judah Levine,
Jian Yao,
Jun Ye,
Eric Oelker
Abstract:
We demonstrate a time scale based on a phase stable optical carrier that accumulates an estimated time error of $48\pm94$ ps over 34 days of operation. This all-optical time scale is formed with a cryogenic silicon cavity exhibiting improved long-term stability and an accurate $^{87}$Sr lattice clock. We show that this new time scale architecture outperforms existing microwave time scales, even wh…
▽ More
We demonstrate a time scale based on a phase stable optical carrier that accumulates an estimated time error of $48\pm94$ ps over 34 days of operation. This all-optical time scale is formed with a cryogenic silicon cavity exhibiting improved long-term stability and an accurate $^{87}$Sr lattice clock. We show that this new time scale architecture outperforms existing microwave time scales, even when they are steered to optical frequency standards. Our analysis indicates that this time scale is capable of reaching a stability below $1\times10^{-17}$ after a few months of averaging, making timekee** at the $10^{-18}$ level a realistic prospect.
△ Less
Submitted 6 July, 2019;
originally announced July 2019.
-
Optical-Clock-Based Time Scale
Authors:
Jian Yao,
Jeff A. Sherman,
Tara Fortier,
Holly Leopardi,
Thomas Parker,
William McGrew,
Xiaogang Zhang,
Daniele Nicolodi,
Robert Fasano,
Stefan Schäffer,
Kyle Beloy,
Joshua Savory,
Stefania Romisch,
Chris Oates,
Scott Diddams,
Andrew Ludlow,
Judah Levine
Abstract:
A time scale is a procedure for accurately and continuously marking the passage of time. It is exemplified by Coordinated Universal Time (UTC), and provides the backbone for critical navigation tools such as the Global Positioning System (GPS). Present time scales employ microwave atomic clocks, whose attributes can be combined and averaged in a manner such that the composite is more stable, accur…
▽ More
A time scale is a procedure for accurately and continuously marking the passage of time. It is exemplified by Coordinated Universal Time (UTC), and provides the backbone for critical navigation tools such as the Global Positioning System (GPS). Present time scales employ microwave atomic clocks, whose attributes can be combined and averaged in a manner such that the composite is more stable, accurate, and reliable than the output of any individual clock. Over the past decade, clocks operating at optical frequencies have been introduced which are orders of magnitude more stable than any microwave clock. However, in spite of their great potential, these optical clocks cannot be operated continuously, which makes their use in a time scale problematic. In this paper, we report the development of a hybrid microwave-optical time scale, which only requires the optical clock to run intermittently while relying upon the ensemble of microwave clocks to serve as the flywheel oscillator. The benefit of using clock ensemble as the flywheel oscillator, instead of a single clock, can be understood by the Dick-effect limit. This time scale demonstrates for the first time sub-nanosecond accuracy for a few months, attaining a fractional frequency uncertainty of 1.45*10-16 at 30 days and reaching the 10-17 decade at 50 days, with respect to UTC. This time scale significantly improves the accuracy in timekee** and could change the existing time-scale architectures.
△ Less
Submitted 10 April, 2019; v1 submitted 18 February, 2019;
originally announced February 2019.
-
Towards Adoption of an Optical Second: Verifying Optical Clocks at the SI Limit
Authors:
W. F. McGrew,
X. Zhang,
H. Leopardi,
R. J. Fasano,
D. Nicolodi,
K. Beloy,
J. Yao,
J. A. Sherman,
S. A. Schäffer,
J. Savory,
R. C. Brown,
S. Römisch,
C. W. Oates,
T. E. Parker,
T. M. Fortier,
A. D. Ludlow
Abstract:
The pursuit of ever more precise measures of time and frequency is likely to lead to the eventual redefinition of the second in terms of an optical atomic transition. To ensure continuity with the current definition, based on a microwave transition between hyperfine levels in ground-state $^{133}$Cs, it is necessary to measure the absolute frequency of candidate standards, which is done by compari…
▽ More
The pursuit of ever more precise measures of time and frequency is likely to lead to the eventual redefinition of the second in terms of an optical atomic transition. To ensure continuity with the current definition, based on a microwave transition between hyperfine levels in ground-state $^{133}$Cs, it is necessary to measure the absolute frequency of candidate standards, which is done by comparing against a primary cesium reference. A key verification of this process can be achieved by performing a loop closure$-$comparing frequency ratios derived from absolute frequency measurements against ratios determined from direct optical comparisons. We measure the $^1$S$_0\!\rightarrow^3$P$_0$ transition of $^{171}$Yb by comparing the clock frequency to an international frequency standard with the aid of a maser ensemble serving as a flywheel oscillator. Our measurements consist of 79 separate runs spanning eight months, and we determine the absolute frequency to be 518 295 836 590 863.71(11) Hz, the uncertainty of which is equivalent to a fractional frequency of $2.1\times10^{-16}$. This absolute frequency measurement, the most accurate reported for any transition, allows us to close the Cs-Yb-Sr-Cs frequency measurement loop at an uncertainty of $<$3$\times10^{-16}$, limited by the current realization of the SI second. We use these measurements to tighten the constraints on variation of the electron-to-proton mass ratio, $μ=m_e/m_p$. Incorporating our measurements with the entire record of Yb and Sr absolute frequency measurements, we infer a coupling coefficient to gravitational potential of $k_\mathrmμ=(-1.9\pm 9.4)\times10^{-7}$ and a drift with respect to time of $\frac{\dotμ}μ=(5.3 \pm 6.5)\times10^{-17}/$yr.
△ Less
Submitted 14 November, 2018;
originally announced November 2018.
-
Ultra-stable optical clock with two cold-atom ensembles
Authors:
M. Schioppo,
R. C. Brown,
W. F. McGrew,
N. Hinkley,
R. J. Fasano,
K. Beloy,
T. H. Yoon,
G. Milani,
D. Nicolodi,
J. A. Sherman,
N. B. Phillips,
C. W. Oates,
A. D. Ludlow
Abstract:
Atomic clocks based on optical transitions are the most stable, and therefore precise, timekeepers available. These clocks operate by alternating intervals of atomic interrogation with dead time required for quantum state preparation and readout. This non-continuous interrogation of the atom system results in the Dick effect, an aliasing of frequency noise of the laser interrogating the atomic tra…
▽ More
Atomic clocks based on optical transitions are the most stable, and therefore precise, timekeepers available. These clocks operate by alternating intervals of atomic interrogation with dead time required for quantum state preparation and readout. This non-continuous interrogation of the atom system results in the Dick effect, an aliasing of frequency noise of the laser interrogating the atomic transition. Despite recent advances in optical clock stability achieved by improving laser coherence, the Dick effect has continually limited optical clock performance. Here we implement a robust solution to overcome this limitation: a zero-dead-time optical clock based on the interleaved interrogation of two cold-atom ensembles. This clock exhibits vanishingly small Dick noise, thereby achieving an unprecedented fractional frequency instability of $6 \times 10^{-17} / \sqrtτ$ for an averaging time $τ$ in seconds. We also consider alternate dual-atom-ensemble schemes to extend laser coherence and reduce the standard quantum limit of clock stability, achieving a spectroscopy line quality factor $Q> 4 \times 10^{15}$.
△ Less
Submitted 22 July, 2016;
originally announced July 2016.
-
Oscillator metrology with software defined radio
Authors:
Jeff A. Sherman,
Robert Jördens
Abstract:
Analog electrical elements such as mixers, filters, transfer oscillators, isolating buffers, dividers, and even transmission lines contribute technical noise and unwanted environmental coupling in time and frequency measurements. Software defined radio (SDR) techniques replace many of these analog components with digital signal processing (DSP) on rapidly sampled signals. We demonstrate that, gene…
▽ More
Analog electrical elements such as mixers, filters, transfer oscillators, isolating buffers, dividers, and even transmission lines contribute technical noise and unwanted environmental coupling in time and frequency measurements. Software defined radio (SDR) techniques replace many of these analog components with digital signal processing (DSP) on rapidly sampled signals. We demonstrate that, generically, commercially available multi-channel SDRs are capable of time and frequency metrology, outperforming purpose-built devices by as much as an order-of-magnitude. For example, for signals at 10 MHz and 6 GHz, we observe SDR time deviation noise floors of about 20 fs and 1 fs, respectively, in under 10 ms of averaging. Examining the other complex signal component, we find a relative amplitude measurement instability of 3e-7 at 5 MHz. We discuss the scalability of a SDR-based system for simultaneous measurement of many clocks. SDR's frequency agility allows for comparison of oscillators at widely different frequencies. We demonstrate a novel and extreme example with optical clock frequencies differing by many terahertz: using a femtosecond-laser frequency comb and SDR, we show femtosecond-level time comparisons of ultra-stable lasers with zero measurement dead-time.
△ Less
Submitted 11 May, 2016;
originally announced May 2016.
-
An atomic clock with $1\times 10^{-18}$ room-temperature blackbody Stark uncertainty
Authors:
K. Beloy,
N. Hinkley,
N. B. Phillips,
J. A. Sherman,
M. Schioppo,
J. Lehman,
A. Feldman,
L. M. Hanssen,
C. W. Oates,
A. D. Ludlow
Abstract:
The Stark shift due to blackbody radiation (BBR) is the key factor limiting the performance of many atomic frequency standards, with the BBR environment inside the clock apparatus being difficult to characterize at a high level of precision. Here we demonstrate an in-vacuum radiation shield that furnishes a uniform, well-characterized BBR environment for the atoms in an ytterbium optical lattice c…
▽ More
The Stark shift due to blackbody radiation (BBR) is the key factor limiting the performance of many atomic frequency standards, with the BBR environment inside the clock apparatus being difficult to characterize at a high level of precision. Here we demonstrate an in-vacuum radiation shield that furnishes a uniform, well-characterized BBR environment for the atoms in an ytterbium optical lattice clock. Operated at room temperature, this shield enables specification of the BBR environment to a corresponding fractional clock uncertainty contribution of $5.5 \times 10^{-19}$. Combined with uncertainty in the atomic response, the total uncertainty of the BBR Stark shift is now $1\times10^{-18}$. Further operation of the shield at elevated temperatures enables a direct measure of the BBR shift temperature dependence and demonstrates consistency between our evaluated BBR environment and the expected atomic response.
△ Less
Submitted 2 December, 2014;
originally announced December 2014.
-
Experimental recovery of a qubit from partial collapse
Authors:
J. A. Sherman,
M. J. Curtis,
D. J. Szwer,
D. T. C. Allcock,
G. Imreh,
D. M. Lucas,
A. M. Steane
Abstract:
We describe and implement a method to restore the state of a single qubit, in principle perfectly, after it has partially collapsed. The method resembles the classical Hahn spin-echo, but works on a wider class of relaxation processes, in which the quantum state partially leaves the computational Hilbert space. It is not guaranteed to work every time, but successful outcomes are heralded. We demon…
▽ More
We describe and implement a method to restore the state of a single qubit, in principle perfectly, after it has partially collapsed. The method resembles the classical Hahn spin-echo, but works on a wider class of relaxation processes, in which the quantum state partially leaves the computational Hilbert space. It is not guaranteed to work every time, but successful outcomes are heralded. We demonstrate using a single trapped ion better performance from this recovery method than can be obtained employing projection and post-selection alone. The demonstration features a novel qubit implementation that permits both partial collapse and coherent manipulations with high fidelity.
△ Less
Submitted 28 October, 2013; v1 submitted 29 July, 2013;
originally announced July 2013.
-
An atomic clock with $10^{-18}$ instability
Authors:
N. Hinkley,
J. A. Sherman,
N. B. Phillips,
M. Schioppo,
N. D. Lemke,
K. Beloy,
M. Pizzocaro,
C. W. Oates,
A. D. Ludlow
Abstract:
Atomic clocks have been transformational in science and technology, leading to innovations such as global positioning, advanced communications, and tests of fundamental constant variation. Next-generation optical atomic clocks can extend the capability of these timekeepers, where researchers have long aspired toward measurement precision at 1 part in $\bm{10^{18}}$. This milestone will enable a se…
▽ More
Atomic clocks have been transformational in science and technology, leading to innovations such as global positioning, advanced communications, and tests of fundamental constant variation. Next-generation optical atomic clocks can extend the capability of these timekeepers, where researchers have long aspired toward measurement precision at 1 part in $\bm{10^{18}}$. This milestone will enable a second revolution of new timing applications such as relativistic geodesy, enhanced Earth- and space-based navigation and telescopy, and new tests on physics beyond the Standard Model. Here, we describe the development and operation of two optical lattice clocks, both utilizing spin-polarized, ultracold atomic ytterbium. A measurement comparing these systems demonstrates an unprecedented atomic clock instability of $\bm{1.6\times 10^{-18}}$ after only $\bm{7}$ hours of averaging.
△ Less
Submitted 24 May, 2013;
originally announced May 2013.
-
Determination of the 5d6s 3D1 state lifetime and blackbody radiation clock shift in Yb
Authors:
K. Beloy,
J. A. Sherman,
N. D. Lemke,
N. Hinkley,
C. W. Oates,
A. D. Ludlow
Abstract:
The Stark shift of the ytterbium optical clock transition due to room temperature blackbody radiation is dominated by a static Stark effect, which was recently measured to high accuracy [J. A. Sherman et al., Phys. Rev. Lett. 108, 153002 (2012)]. However, room temperature operation of the clock at 10^{-18} inaccuracy requires a dynamic correction to this static approximation. This dynamic correcti…
▽ More
The Stark shift of the ytterbium optical clock transition due to room temperature blackbody radiation is dominated by a static Stark effect, which was recently measured to high accuracy [J. A. Sherman et al., Phys. Rev. Lett. 108, 153002 (2012)]. However, room temperature operation of the clock at 10^{-18} inaccuracy requires a dynamic correction to this static approximation. This dynamic correction largely depends on a single electric dipole matrix element for which theoretically and experimentally derived values disagree significantly. We determine this important matrix element by two independent methods, which yield consistent values. Along with precise radiative lifetimes of 6s6p 3P1 and 5d6s 3D1, we report the clock's blackbody radiation shift to 0.05% precision.
△ Less
Submitted 2 August, 2012;
originally announced August 2012.
-
Coherent Excitation of the 6S1/2 to 5D3/2 Electric Quadrupole Transition in 138Ba+
Authors:
Adam Kleczewski,
Matthew Hoffman,
J. A. Sherman,
Eric Magnuson,
Boris B. Blinov,
E. N. Fortson
Abstract:
The electric dipole-forbidden, quadrupole 6S1/2 <-> 5D3/2 transition in Ba+ near 2051 nm, with a natural linewidth of 13 mHz, is attractive for potential observation of parity non-conservation, and also as a clock transition for a barium ion optical frequency standard. This transition also offers a direct means of populating the metastable 5D3/2 state to measure the nuclear magnetic octupole momen…
▽ More
The electric dipole-forbidden, quadrupole 6S1/2 <-> 5D3/2 transition in Ba+ near 2051 nm, with a natural linewidth of 13 mHz, is attractive for potential observation of parity non-conservation, and also as a clock transition for a barium ion optical frequency standard. This transition also offers a direct means of populating the metastable 5D3/2 state to measure the nuclear magnetic octupole moment in the odd barium isotopes. Light from a diode-pumped, solid state Tm,Ho:YLF laser operating at 2051 nm is used to coherently drive this transition between resolved Zeeman levels in a single trapped 138Ba+ ion. The frequency of the laser is stabilized to a high finesse Fabry Perot cavity at 1025 nm after being frequency doubled. Rabi oscillations on this transition indicate a laser-ion coherence time of 3 ms, most likely limited by ambient magnetic field fluctuations.
△ Less
Submitted 8 March, 2012;
originally announced March 2012.
-
High accuracy measure of atomic polarizability in an optical lattice clock
Authors:
J. A. Sherman,
N. D. Lemke,
N. Hinkley,
M. Pizzocaro,
R. W. Fox,
A. D. Ludlow,
C. W. Oates
Abstract:
Despite being a canonical example of quantum mechanical perturbation theory, as well as one of the earliest observed spectroscopic shifts, the Stark effect contributes the largest source of uncertainty in a modern optical atomic clock through blackbody radiation. By employing an ultracold, trapped atomic ensemble and high stability optical clock, we characterize the quadratic Stark effect with unp…
▽ More
Despite being a canonical example of quantum mechanical perturbation theory, as well as one of the earliest observed spectroscopic shifts, the Stark effect contributes the largest source of uncertainty in a modern optical atomic clock through blackbody radiation. By employing an ultracold, trapped atomic ensemble and high stability optical clock, we characterize the quadratic Stark effect with unprecedented precision. We report the ytterbium optical clock's sensitivity to electric fields (such as blackbody radiation) as the differential static polarizability of the ground and excited clock levels: 36.2612(7) kHz (kV/cm)^{-2}. The clock's fractional uncertainty due to room temperature blackbody radiation is reduced an order of magnitude to 3 \times 10^{-17}.
△ Less
Submitted 12 December, 2011;
originally announced December 2011.
-
Stability limits of an optical frequency standard based on free Ca atoms
Authors:
J. A. Sherman,
C. W. Oates
Abstract:
We have quantified a short term instability budget for an optical frequency standard based on cold, freely expanding calcium atoms. Such systems are the subject of renewed interest due to their high frequency stability and relative technical simplicity compared to trapped atom optical clocks. By filtering the clock laser light at 657 nm through a high finesse cavity, we observe a slight reduction…
▽ More
We have quantified a short term instability budget for an optical frequency standard based on cold, freely expanding calcium atoms. Such systems are the subject of renewed interest due to their high frequency stability and relative technical simplicity compared to trapped atom optical clocks. By filtering the clock laser light at 657 nm through a high finesse cavity, we observe a slight reduction in the optical Dick effect caused by aliased local oscillator noise. The ultimately limiting technical noise is measured using a technique that does not rely on a second clock or fs-comb.
△ Less
Submitted 16 August, 2011;
originally announced August 2011.
-
Cold collision shift cancelation and inelastic scattering in a Yb optical lattice clock
Authors:
A. D. Ludlow,
N. D. Lemke,
J. A. Sherman,
C. W. Oates,
G. Quemener,
J. von Stecher,
A. M. Rey
Abstract:
Recently, p-wave cold collisions were shown to dominate the density-dependent shift of the clock transition frequency in a 171Yb optical lattice clock. Here we demonstrate that by operating such a system at the proper excitation fraction, the cold collision shift is canceled below the 5x10^{-18} fractional frequency level. We report inelastic two-body loss rates for 3P0-3P0 and 1S0-3P0 scattering.…
▽ More
Recently, p-wave cold collisions were shown to dominate the density-dependent shift of the clock transition frequency in a 171Yb optical lattice clock. Here we demonstrate that by operating such a system at the proper excitation fraction, the cold collision shift is canceled below the 5x10^{-18} fractional frequency level. We report inelastic two-body loss rates for 3P0-3P0 and 1S0-3P0 scattering. We also measure interaction shifts in an unpolarized atomic sample. Collision measurements for this spin-1/2 171Yb system are relevant for high performance optical clocks as well as strongly-interacting systems for quantum information and quantum simulation applications.
△ Less
Submitted 10 August, 2011; v1 submitted 5 August, 2011;
originally announced August 2011.
-
p-Wave cold collisions in an optical lattice clock
Authors:
N. D. Lemke,
J. von Stecher,
J. A. Sherman,
A. M. Rey,
C. W. Oates,
A. D. Ludlow
Abstract:
We study ultracold collisions in fermionic ytterbium by precisely measuring the energy shifts they impart on the atom's internal clock states. Exploiting Fermi statistics, we uncover p-wave collisions, in both weakly and strongly interacting regimes. With the higher density afforded by two-dimensional lattice confinement, we demonstrate that strong interactions can lead to a novel suppression of t…
▽ More
We study ultracold collisions in fermionic ytterbium by precisely measuring the energy shifts they impart on the atom's internal clock states. Exploiting Fermi statistics, we uncover p-wave collisions, in both weakly and strongly interacting regimes. With the higher density afforded by two-dimensional lattice confinement, we demonstrate that strong interactions can lead to a novel suppression of this collision shift. In addition to reducing the systematic errors of lattice clocks, this work has application to quantum information and quantum simulation with alkaline-earth atoms.
△ Less
Submitted 22 June, 2011; v1 submitted 10 May, 2011;
originally announced May 2011.
-
Making optical atomic clocks more stable with $10^{-16}$ level laser stabilization
Authors:
Y. Y. Jiang,
A. D. Ludlow,
N. D. Lemke,
R. W. Fox,
J. A. Sherman,
L. -S. Ma,
C. W. Oates
Abstract:
The superb precision of an atomic clock is derived from its stability. Atomic clocks based on optical (rather than microwave) frequencies are attractive because of their potential for high stability, which scales with operational frequency. Nevertheless, optical clocks have not yet realized this vast potential, due in large part to limitations of the laser used to excite the atomic resonance. To a…
▽ More
The superb precision of an atomic clock is derived from its stability. Atomic clocks based on optical (rather than microwave) frequencies are attractive because of their potential for high stability, which scales with operational frequency. Nevertheless, optical clocks have not yet realized this vast potential, due in large part to limitations of the laser used to excite the atomic resonance. To address this problem, we demonstrate a cavity-stabilized laser system with a reduced thermal noise floor, exhibiting a fractional frequency instability of $2 \times 10^{-16}$. We use this laser as a stable optical source in a Yb optical lattice clock to resolve an ultranarrow 1 Hz transition linewidth. With the stable laser source and the signal to noise ratio (S/N) afforded by the Yb optical clock, we dramatically reduce key stability limitations of the clock, and make measurements consistent with a clock instability of $5 \times 10^{-16} / \sqrtτ$.
△ Less
Submitted 6 January, 2011;
originally announced January 2011.
-
Implementation of a symmetric surface electrode ion trap with field compensation using a modulated Raman effect
Authors:
D. T. C. Allcock,
J. A. Sherman,
D. N. Stacey,
A. H. Burrell,
M. J. Curtis,
G. Imreh,
N. M. Linke,
D. J. Szwer,
S. C. Webster,
A. M. Steane,
D. M. Lucas
Abstract:
We describe the fabrication and characterization of a new surface-electrode Paul ion trap designed for experiments in scalable quantum information processing with Ca+. A notable feature is a symmetric electrode pattern which allows rotation of the normal modes of ion motion, yielding efficient Doppler cooling with a single beam parallel to the planar surface. We propose and implement a technique…
▽ More
We describe the fabrication and characterization of a new surface-electrode Paul ion trap designed for experiments in scalable quantum information processing with Ca+. A notable feature is a symmetric electrode pattern which allows rotation of the normal modes of ion motion, yielding efficient Doppler cooling with a single beam parallel to the planar surface. We propose and implement a technique for micromotion compensation in all directions using an infrared repumper laser beam directed into the trap plane. Finally, we employ an alternate repum** scheme that increases ion fluorescence and simplifies heating rate measurements obtained by time-resolved ion fluorescence during Doppler cooling.
△ Less
Submitted 15 November, 2009; v1 submitted 17 September, 2009;
originally announced September 2009.
-
Single barium ion spectroscopy: light shifts, hyperfine structure, and progress on an optical frequency standard and atomic parity violation
Authors:
Jeff A. Sherman
Abstract:
Single trapped ions are ideal systems in which to test atomic physics at high precision: they are effectively isolated atoms held at rest and largely free from perturbing interactions. This thesis describes several projects developed to study the structure of singly-ionized barium and more fundamental physics.
First, we describe a spin-dependent "electron-shelving" scheme that allows us to per…
▽ More
Single trapped ions are ideal systems in which to test atomic physics at high precision: they are effectively isolated atoms held at rest and largely free from perturbing interactions. This thesis describes several projects developed to study the structure of singly-ionized barium and more fundamental physics.
First, we describe a spin-dependent "electron-shelving" scheme that allows us to perform single ion electron spin resonance experiments in both the ground 6S_{1/2} and metastable 5D_{3/2} states at precision levels of 10^{-5}. We employ this technique to measure the ratio of off-resonant light shifts (or ac-Stark effect) in these states to a precision of 10^{-3} at two different wavelengths. These results constitute a new high precision test of heavy-atom atomic theory. Such experimental tests in Ba+ are in high demand since knowledge of key dipole matrix elements is currently limited to about 5%. Ba+ has recently been the subject of theoretical interest towards a test of atomic parity violation for which knowledge of dipole matrix elements is an important prerequisite. We summarize this parity violation experimental concept and describe new ideas. (continued...)
△ Less
Submitted 1 July, 2009;
originally announced July 2009.
-
Precision measurement of light shifts at two off-resonant wavelengths in a single trapped Ba+ ion and determination of atomic dipole matrix elements
Authors:
J. A. Sherman,
A. Andalkar,
W. Nagourney,
E. N. Fortson
Abstract:
We define and measure the ratio (R) of the vector ac-Stark effect (or light shift) in the 6S_1/2 and 5D_3/2 states of a single trapped barium ion to 0.2% accuracy at two different off-resonant wavelengths. We earlier found R = -11.494(13) at 514.531nm and now report the value at 1111.68nm, R = +0.4176(8). These observations together yield a value of the <5D||er||4F> matrix element, previously un…
▽ More
We define and measure the ratio (R) of the vector ac-Stark effect (or light shift) in the 6S_1/2 and 5D_3/2 states of a single trapped barium ion to 0.2% accuracy at two different off-resonant wavelengths. We earlier found R = -11.494(13) at 514.531nm and now report the value at 1111.68nm, R = +0.4176(8). These observations together yield a value of the <5D||er||4F> matrix element, previously unknown in the literature. Also, comparison of our results with an ab initio calculation of dynamic polarizability would yield a new test of atomic theory and improve the understanding of atomic structure needed to interpret a proposed atomic parity violation experiment.
△ Less
Submitted 13 August, 2008;
originally announced August 2008.
-
Progress on indium and barium single ion optical frequency standards
Authors:
Jeff A. Sherman,
William Trimble,
Steven Metz,
Warren Nagourney,
Norval Fortson
Abstract:
We report progress on 115In+ and 137Ba+ single ion optical frequency standards using all solid-state sources. Both are free from quadrupole field shifts and together enable a search for drift in fundamental constants.
We report progress on 115In+ and 137Ba+ single ion optical frequency standards using all solid-state sources. Both are free from quadrupole field shifts and together enable a search for drift in fundamental constants.
△ Less
Submitted 1 April, 2005; v1 submitted 1 April, 2005;
originally announced April 2005.
-
Precision measurement of light shifts in a single trapped Ba$^+$ ion
Authors:
J. A. Sherman,
T. W. Koerber,
A. Markhotok,
W. Nagourney,
E. N. Fortson
Abstract:
Using a single trapped barium ion we have developed an rf spectroscopy technique to measure the ratio of the off-resonant vector ac Stark effect (or light shift) in the 6S_{1/2} and 5D_{3/2} states to 0.1% precision. We find R = Delta_S / Delta_D = -11.494(13) at 514.531 nm where Delta_{S,D} are the light shifts of the m = +/- 1/2 splittings due to circularly polarized light. Comparison of this…
▽ More
Using a single trapped barium ion we have developed an rf spectroscopy technique to measure the ratio of the off-resonant vector ac Stark effect (or light shift) in the 6S_{1/2} and 5D_{3/2} states to 0.1% precision. We find R = Delta_S / Delta_D = -11.494(13) at 514.531 nm where Delta_{S,D} are the light shifts of the m = +/- 1/2 splittings due to circularly polarized light. Comparison of this result with an ab initio calculation of R would yield a new test of atomic theory. By appropriately choosing an off-resonant light shift wavelength one can emphasize the contribution of one or a few dipole matrix elements and precisely determine their values.
△ Less
Submitted 22 February, 2005;
originally announced February 2005.