-
Error analysis of vertical test for CEPC 650 MHz superconducting radio-frequency cavity
Authors:
Lingxi Ye,
Peng Sha,
Zhenghui Mi,
Feisi He,
Jiyuan Zhai
Abstract:
Hundreds of 650 MHz superconducting radio-frequency (SRF) cavities with high intrinsic quality factor (Q0) and accelerating gradient (Eacc) will be adopted for Circular Electron Positron Collider (CEPC). The values of Q0 and Eacc are obtained during vertical test at 2.0 K. Hence, high accuracy of vertical test is essential for evaluating the performance of SRF cavity. The 650 MHz SRF cavities achi…
▽ More
Hundreds of 650 MHz superconducting radio-frequency (SRF) cavities with high intrinsic quality factor (Q0) and accelerating gradient (Eacc) will be adopted for Circular Electron Positron Collider (CEPC). The values of Q0 and Eacc are obtained during vertical test at 2.0 K. Hence, high accuracy of vertical test is essential for evaluating the performance of SRF cavity. The 650 MHz SRF cavities achieved very high Q0 (6E10) and Eacc (40 MV/m) during the vertical test. In our study, the error analysis of vertical test was conducted in the scalar case, in order to achieve high accuracy. The uncertainties of vertical test were obtained through calculation, which was approximately 3% for Eacc and less than 5% for Q0. This result was reasonable and acceptable.
△ Less
Submitted 9 June, 2024;
originally announced June 2024.
-
High Q and high gradient performance of the first medium-temperature baking 1.3 GHz cryomodule
Authors:
Jiyuan Zhai,
Weimin Pan,
Feisi He,
Rui Ge,
Zhenghui Mi,
Peng Sha,
Song **,
Ruixiong Han,
Qunyao Wang,
Haiying Lin,
Guangwei Wang,
Mei Li,
Min**g Sang,
Liangrui Sun,
Rui Ye,
Tongxian Zhao,
Shaopeng Li,
Keyu Zhu,
Baiqi Liu,
Xiaolong Wang,
Xiangchen Yang,
Xiaojuan Bian,
Xiangzhen Zhang,
Huizhou Ma,
Xuwen Dai
, et al. (14 additional authors not shown)
Abstract:
World's first 1.3 GHz cryomodule containing eight 9-cell superconducting radio-frequency (RF) cavities treated by medium-temperature furnace baking (mid-T bake) was developed, assembled and tested at IHEP for the Dalian Advanced Light Source (DALS) and CEPC R&D. The 9-cell cavities in the cryomodule achieved an unprecedented highest average Q0 of 3.8E10 at 16 MV/m and 3.6E10 at 21 MV/m in the hori…
▽ More
World's first 1.3 GHz cryomodule containing eight 9-cell superconducting radio-frequency (RF) cavities treated by medium-temperature furnace baking (mid-T bake) was developed, assembled and tested at IHEP for the Dalian Advanced Light Source (DALS) and CEPC R&D. The 9-cell cavities in the cryomodule achieved an unprecedented highest average Q0 of 3.8E10 at 16 MV/m and 3.6E10 at 21 MV/m in the horizontal test. The cryomodule can operate stably up to a total CW RF voltage greater than 191 MV, with an average cavity CW accelerating gradient of more than 23 MV/m. The results significantly exceed the specifications of CEPC, DALS and the other high repetition rate free electron laser facilities (LCLS-II, LCLS-II-HE, SHINE, S3FEL). There is evidence that the mid-T bake cavity may not require fast cool-down or long processing time in the cryomodule. This paper reviews the cryomodule performance and discusses some important issues in cryomodule assembly and testing.
△ Less
Submitted 2 December, 2023;
originally announced December 2023.
-
SRF Cavity Searches for Dark Photon Dark Matter: First Scan Results
Authors:
Zhenxing Tang,
Bo Wang,
Yifan Chen,
Yanjie Zeng,
Chunlong Li,
Yuting Yang,
Liwen Feng,
Peng Sha,
Zhenghui Mi,
Weimin Pan,
Tianzong Zhang,
Yirong **,
Jiankui Hao,
Lin Lin,
Fang Wang,
Huamu Xie,
Senlin Huang,
**g Shu
Abstract:
We present the first use of a tunable superconducting radio frequency cavity to perform a scan search for dark photon dark matter with novel data analysis strategies. We mechanically tuned the resonant frequency of a cavity embedded in the liquid helium with a temperature of $2$ K, scanning the dark photon mass over a frequency range of $1.37$ MHz centered at $1.3$ GHz. By exploiting the supercond…
▽ More
We present the first use of a tunable superconducting radio frequency cavity to perform a scan search for dark photon dark matter with novel data analysis strategies. We mechanically tuned the resonant frequency of a cavity embedded in the liquid helium with a temperature of $2$ K, scanning the dark photon mass over a frequency range of $1.37$ MHz centered at $1.3$ GHz. By exploiting the superconducting radio frequency cavity's considerably high quality factors of approximately $10^{10}$, our results demonstrate the most stringent constraints to date on a substantial portion of the exclusion parameter space, particularly concerning the kinetic mixing coefficient between dark photons and electromagnetic photons $ε$, yielding a value of $ε< 2.2 \times 10^{-16}$.
△ Less
Submitted 25 May, 2023; v1 submitted 16 May, 2023;
originally announced May 2023.
-
Design of new helium vessel and tuner for CEPC 650 MHz 2 cell cavity
Authors:
Z. H. Mi,
Z. Q. Li,
P. Sha,
J. Y. Zhai,
F. S. He,
Q. Ma,
B. Q. Liu,
X. Y. Zhang,
R. X. Han,
F. B. Meng,
H. J. Zheng
Abstract:
CEPC will use 650 MHz cavities for the collider. Each collider cryomodule contains six 650 MHz 2-cell cavities, which is totally new. Therefore, new helium vessel and tuner are designed for the 650 MHz 2-cell cavity. Also, a test cryomodule, which consists of two 650 MHz 2-cell cavities, has begun as the first step to the full scale cryomodule. This paper mainly focuses on the structure design of…
▽ More
CEPC will use 650 MHz cavities for the collider. Each collider cryomodule contains six 650 MHz 2-cell cavities, which is totally new. Therefore, new helium vessel and tuner are designed for the 650 MHz 2-cell cavity. Also, a test cryomodule, which consists of two 650 MHz 2-cell cavities, has begun as the first step to the full scale cryomodule. This paper mainly focuses on the structure design of Helium vessel and tuner for the 2-cell cavity.
△ Less
Submitted 7 January, 2023;
originally announced January 2023.
-
Parasitic modes suppression in CW cold tests of 1.3 GHz 9-cell high Q cavities at IHEP
Authors:
Zhenghui Mi,
Feisi He,
Weimin Pan,
Peng Sha,
Jiyuan Zhai,
Xuwen Dai,
Song **a,
Zhanjun Zhang,
Chao Dong,
Baiqi Liu,
Hui Zhao,
Rui Gea,
Jianbing Zhao,
Zhihui Mu,
Lei Du,
Liangrui Sun,
Liang Zhang,
Conglai Yang,
Xiaobing Zheng,
Haiying Lin,
Guangwei Wang,
Xiangcong He
Abstract:
The CW RF test of 1.3 GHz 9-cell cavity in liquid helium bath at 2 K is a very important key point in the cavity procurement. Some problems can be found through the test, according which to optimized and improve the process of cavity. Recently, Medium temperature (mid-T) furnace bake of 1.3 GHz 9-cell cavities have been carried out at IHEP. Through the proceed of mid-T bake, the quality factor of…
▽ More
The CW RF test of 1.3 GHz 9-cell cavity in liquid helium bath at 2 K is a very important key point in the cavity procurement. Some problems can be found through the test, according which to optimized and improve the process of cavity. Recently, Medium temperature (mid-T) furnace bake of 1.3 GHz 9-cell cavities have been carried out at IHEP. Through the proceed of mid-T bake, the quality factor of cavity has been greatly improved. While the excitation of the parasitic modes in the high Q cavities CW cold test has been encountered, which implies an error source for the cavity gradient and quality factor determination. In order to ensure the testing accuracy of superconducting cavity, we have improved the testing system. Finally, the parasitic mode is completely suppressed and the CW RF cold test of high Q cavity is guaranteed.
△ Less
Submitted 26 March, 2021;
originally announced March 2021.
-
Medium-temperature furnace bake of Superconducting Radio-Frequency cavities at IHEP
Authors:
Feisi He,
Weimin Pan,
Peng Sha,
Jiyuan Zhai,
Zhenghui Mi,
Xuwen Dai,
Song **,
Zhanjun Zhang,
Chao Dong,
Baiqi Liu,
Hui Zhao,
Rui Ge,
Jianbing Zhao,
Zhihui Mu,
Lei Du,
Liangrui Sun,
Liang Zhang,
Conglai Yang,
Xiaobing Zheng
Abstract:
Recently, heat treatment between 250 C and 500 C has been attempted to improve quality factor of superconducting radio-frequency cavities at FNAL and KEK. Experiments of such medium temperature (mid-T) bake with furnaces have also been carried out at IHEP. Firstly, eleven 1.3 GHz 1-cell cavities were treated with different temperatures at a small furnace. The average quality factor has reached 3.6…
▽ More
Recently, heat treatment between 250 C and 500 C has been attempted to improve quality factor of superconducting radio-frequency cavities at FNAL and KEK. Experiments of such medium temperature (mid-T) bake with furnaces have also been carried out at IHEP. Firstly, eleven 1.3 GHz 1-cell cavities were treated with different temperatures at a small furnace. The average quality factor has reached 3.6E10 when the gradient is 16 MV/m. Then, the recipe of mid-T furnace bake at 300 C for 3 hours has been applied to six 1.3 GHz 9-cell cavities at a new big furnace. The average quality factor has reached 3.8E10 when the gradient is 16 MV/m.
△ Less
Submitted 8 December, 2020;
originally announced December 2020.
-
Demonstration of electron cooling using a pulsed beam from an electrostatic electron cooler
Authors:
M. W. Bruker,
S. Benson,
A. Hutton,
K. Jordan,
T. Powers,
R. Rimmer,
T. Satogata,
A. Sy,
H. Wang,
S. Wang,
H. Zhang,
Y. Zhang,
F. Ma,
J. Li,
X. M. Ma,
L. J. Mao,
X. P. Sha,
M. T. Tang,
J. C. Yang,
X. D. Yang,
H. Zhao,
H. W. Zhao
Abstract:
Cooling of hadron beams is critically important in the next generation of hadron storage rings for delivery of unprecedented performance. One such application is the electron-ion collider presently under development in the US. The desire to develop electron coolers for operation at much higher energies than previously achieved necessitates the use of radio-frequency (RF) fields for acceleration as…
▽ More
Cooling of hadron beams is critically important in the next generation of hadron storage rings for delivery of unprecedented performance. One such application is the electron-ion collider presently under development in the US. The desire to develop electron coolers for operation at much higher energies than previously achieved necessitates the use of radio-frequency (RF) fields for acceleration as opposed to the conventional, electrostatic approach. While electron cooling is a mature technology at low energy utilizing a DC beam, RF acceleration requires the cooling beam to be bunched, thus extending the parameter space to an unexplored territory. It is important to experimentally demonstrate the feasibility of cooling with electron bunches and further investigate how the relative time structure of the two beams affects the cooling properties; thus, a set of four pulsed-beam cooling experiments was carried out by a collaboration of Jefferson Lab and Institute of Modern Physics (IMP).
The experiments have successfully demonstrated cooling with a beam of electron bunches in both the longitudinal and transverse directions for the first time. We have measured the effect of the electron bunch length and longitudinal ion focusing strength on the temporal evolution of the longitudinal and transverse ion beam profile and demonstrate that if the synchronization can be accurately maintained, the dynamics are not adversely affected by the change in time structure.
△ Less
Submitted 29 October, 2020;
originally announced October 2020.
-
Measuring mechanical anisotropy of the cornea with Brillouin microscopy
Authors:
Amira M. Eltony,
Peng Shao,
Seok-Hyun Yun
Abstract:
Load-bearing tissues are typically fortified by networks of protein fibers, often with preferential orientations. This fiber structure imparts the tissues with direction-dependent mechanical properties optimized to support specific external loads. To accurately model and predict tissues' mechanical response, it is essential to characterize the anisotropy on a microstructural scale. Previously, it…
▽ More
Load-bearing tissues are typically fortified by networks of protein fibers, often with preferential orientations. This fiber structure imparts the tissues with direction-dependent mechanical properties optimized to support specific external loads. To accurately model and predict tissues' mechanical response, it is essential to characterize the anisotropy on a microstructural scale. Previously, it has been difficult to measure the mechanical properties of intact tissues noninvasively. Here, we use Brillouin optical microscopy to visualize and quantify the anisotropic mechanical properties of corneal tissues at different length scales. We derive the stiffness tensor for a lamellar network of collagen fibrils and use angle-resolved Brillouin measurements to determine the longitudinal stiffness coefficients (longitudinal moduli) describing the ex vivo porcine cornea as a transverse isotropic material. Lastly, we observe significant mechanical anisotropy of the human cornea in vivo, highlighting the potential for clinical applications of off-axis Brillouin microscopy.
△ Less
Submitted 1 March, 2022; v1 submitted 9 March, 2020;
originally announced March 2020.
-
Spatially-resolved Brillouin spectroscopy reveals biomechanical changes in early ectatic corneal disease and post-crosslinking in vivo
Authors:
Peng Shao,
Amira M. Eltony,
Theo G. Seiler,
Behrouz Tavakol,
Roberto Pineda,
Tobias Koller,
Theo Seiler,
Seok-Hyun Yun
Abstract:
Mounting evidence connects the biomechanical properties of tissues to the development of eye diseases such as keratoconus, a common disease in which the cornea thins and bulges into a conical shape. However, measuring biomechanical changes in vivo with sufficient sensitivity for disease detection has proved challenging. Here, we present a first large-scale study (~200 subjects, including normal an…
▽ More
Mounting evidence connects the biomechanical properties of tissues to the development of eye diseases such as keratoconus, a common disease in which the cornea thins and bulges into a conical shape. However, measuring biomechanical changes in vivo with sufficient sensitivity for disease detection has proved challenging. Here, we present a first large-scale study (~200 subjects, including normal and keratoconus patients) using Brillouin light-scattering microscopy to measure longitudinal modulus in corneal tissues with high sensitivity and spatial resolution. Our results in vivo provide evidence of biomechanical inhomogeneity at the onset of keratoconus and suggest that biomechanical asymmetry between the left and right eyes may presage disease development. We additionally measure the stiffening effect of corneal crosslinking treatment in vivo for the first time. Our results demonstrate the promise of Brillouin microscopy for diagnosis and treatment of keratoconus, and potentially other diseases.
△ Less
Submitted 3 February, 2018;
originally announced February 2018.
-
Commissioning of te China-ADS injector-I testing facility
Authors:
Fang Yan,
Hui** Geng,
Cai Meng,
Yaliang Zhao,
Huafu Ouyang,
Shilun Pei,
Rong Liu,
Feisi He,
Tongming Huang,
Rui Ge,
Yanfeng Sui,
Qiang Ye,
** **g,
Fengli Long,
Jungang Li,
Quanling Peng,
Dizhou Guo,
Zusheng Zhou,
Haiyin Lin,
Xinpeng Ma,
Qunyao Wang,
Guangwei Wang,
Hua Shi,
Gang Wu,
Shengchang Wang
, et al. (36 additional authors not shown)
Abstract:
The 10 MeV accelerator-driven subcritical system (ADS) Injector-I test stand at Institute of High Energy Physics (IHEP) is a testing facility dedicated to demonstrate one of the two injector design schemes [Injector Scheme-I, which works at 325 MHz], for the ADS project in China. The Injector adopted a four vane copper structure RFQ with output energy of 3.2 MeV and a superconducting (SC) section…
▽ More
The 10 MeV accelerator-driven subcritical system (ADS) Injector-I test stand at Institute of High Energy Physics (IHEP) is a testing facility dedicated to demonstrate one of the two injector design schemes [Injector Scheme-I, which works at 325 MHz], for the ADS project in China. The Injector adopted a four vane copper structure RFQ with output energy of 3.2 MeV and a superconducting (SC) section accommodating fourteen \b{eta}g=0.12 single spoke cavities, fourteen SC solenoids and fourteen cold BPMs. The ion source was installed since April of 2014, periods of commissioning are regularly scheduled between installation phases of the rest of the injector. Continuous wave (CW) beam was shooting through the injector and 10 MeV CW proton beam with average beam current around 2 mA was obtained recently. This contribution describe the results achieved so far and the difficulties encountered in CW commissioning.
△ Less
Submitted 15 May, 2017;
originally announced May 2017.
-
High-extinction VIPA-based Brillouin spectroscopy of turbid biological media
Authors:
Antonio Fiore,
Jitao Zhang,
Peng Shao,
Seok Hyun Yun,
Giuliano Scarcelli
Abstract:
Brillouin microscopy has recently emerged as powerful technique to characterize the mechanical properties of biological tissue, cell and biomaterials. However, the potential of Brillouin microscopy is currently limited to transparent samples, because Brillouin spectrometers do not have sufficient spectral extinction to reject the predominant non-Brillouin scattered light of turbid media. To overco…
▽ More
Brillouin microscopy has recently emerged as powerful technique to characterize the mechanical properties of biological tissue, cell and biomaterials. However, the potential of Brillouin microscopy is currently limited to transparent samples, because Brillouin spectrometers do not have sufficient spectral extinction to reject the predominant non-Brillouin scattered light of turbid media. To overcome this issue, we developed a spectrometer composed of a two VIPA stages and a multi-pass Fabry-Perot interferometer. The Fabry-Perot etalon acts as an ultra-narrow band-pass filter for Brillouin light with high spectral extinction and low loss. We report background-free Brillouin spectra from Intralipid solutions and up to 100 microns deep within chicken muscle tissue.
△ Less
Submitted 17 April, 2016;
originally announced April 2016.
-
Structure and function of Enterotoxigenic Escherichia coli fimbriae from differing assembly pathways
Authors:
Narges Mortezaei,
Chelsea R. Epler,
Paul P. Shao,
Mariam Shirdel,
Bhupender Singh,
Annette McVeigh,
Bernt Eric Uhlin,
Stephen J. Savarino,
Magnus Andersson,
Esther Bullitt
Abstract:
Pathogenic enterotoxigenic Escherichia coli (ETEC) are the major bacterial cause of diarrhea in young children in develo** countries and in travelers, causing significant mortality in children. Adhesive fimbriae are a prime virulence factor for ETEC, initiating colonization of the small intestinal epithelium. Similar to other Gram-negative bacteria, ETEC express one or more diverse fimbriae, som…
▽ More
Pathogenic enterotoxigenic Escherichia coli (ETEC) are the major bacterial cause of diarrhea in young children in develo** countries and in travelers, causing significant mortality in children. Adhesive fimbriae are a prime virulence factor for ETEC, initiating colonization of the small intestinal epithelium. Similar to other Gram-negative bacteria, ETEC express one or more diverse fimbriae, some assembled by the chaperone-usher pathway and others by the alternate chaperone pathway. Here we elucidate structural and biophysical aspects and adaptations of each fimbrial type to its respective host niche. CS20 fimbriae are compared to CFA/I fimbriae, which are two ETEC fimbriae assembled via different pathways, and to Pfimbriae from uropathogenic E. coli. Many fimbriae unwind from their native helical filament to an extended linear conformation under force, thereby sustaining adhesion by reducing load at the point of contact between the bacterium and the target cell. CFA/I fimbriae require the least force to unwind, followed by CS20 fimbriae and then P-fimbriae, which require the highest unwinding force. We conclude from our electron microscopy reconstructions, modeling, and force spectroscopy data that the target niche plays a central role in the biophysical properties of fimbriae that are critical for bacterial pathophysiology.
△ Less
Submitted 6 November, 2014;
originally announced November 2014.
-
Design and test of frequency tuner for CAEP high power THz free-electron laser
Authors:
Zhenghui Mi,
Yi Sun,
Weimin Pan,
Haiying Lin,
Danyang Zhao,
Xiangyang Lu,
Shengwen Quan,
Xing Luo,
Ming Li,
Xingfan Yang,
Guangwei Wang,
Jian** Dai,
Zhongquan Li,
Qiang Ma,
Peng Sha
Abstract:
Peking University is develo** a 1.3 GHz superconducting accelerating section for China Academy of Engineering Physics (CAEP) high power THz free-electron laser. A compact fast/slow tuner has developed by Institute of High Energy Physics (IHEP) for the accelerating section, to control Lorentz detuning, beam loading effect, compensate for microphonics and liquid Helium pressure fluctuations. The t…
▽ More
Peking University is develo** a 1.3 GHz superconducting accelerating section for China Academy of Engineering Physics (CAEP) high power THz free-electron laser. A compact fast/slow tuner has developed by Institute of High Energy Physics (IHEP) for the accelerating section, to control Lorentz detuning, beam loading effect, compensate for microphonics and liquid Helium pressure fluctuations. The tuner design, warm test and cold test of the first prototype are presented.
△ Less
Submitted 14 April, 2014;
originally announced April 2014.
-
Design of a 325MHz Beta=0.12 superconducting single spoke cavity for China-ADS
Authors:
Han Li,
Jian** Dai,
Peng Sha,
Hong Huang,
Qunyao Wang,
juan Zhang,
Zhongyuan Yao,
Xiangyang Lu
Abstract:
Twelve superconducting single spoke cavities whose Beta is 0.12 (Spoke012) operating at 325MHz, are adopted in Injector I for China-ADS linac. This type of spoke cavity is believed to be one of the key challenges for its very low geometry Beta. So far, the prototype cavity has been designed, fabricated and tested successfully. The design work was finished by using CST-MWS and ANSYS software for th…
▽ More
Twelve superconducting single spoke cavities whose Beta is 0.12 (Spoke012) operating at 325MHz, are adopted in Injector I for China-ADS linac. This type of spoke cavity is believed to be one of the key challenges for its very low geometry Beta. So far, the prototype cavity has been designed, fabricated and tested successfully. The design work was finished by using CST-MWS and ANSYS software for the RF and mechanical properties optimization. This paper presents the details of the final design for Spoke012 prototype cavity.
△ Less
Submitted 5 October, 2013;
originally announced October 2013.