-
Direct Detection Constraints on Dark Photons with CDEX-10 Experiment at the China **** Underground Laboratory
Authors:
Z. She,
L. P. Jia,
Q. Yue,
H. Ma,
K. J. Kang,
Y. J. Li,
M. Agartioglu,
H. P. An,
J. P. Chang,
J. H. Chen,
Y. H. Chen,
J. P. Cheng,
W. H. Dai,
Z. Deng,
X. P. Geng,
H. Gong,
P. Gu,
Q. J. Guo,
X. Y. Guo,
L. He,
S. M. He,
H. T. He,
J. W. Hu,
T. C. Huang,
H. X. Huang
, et al. (59 additional authors not shown)
Abstract:
We report constraints on the dark photon effective kinetic mixing parameter ($κ$) with data taken from two ${p}$-type point-contact germanium detectors of the CDEX-10 experiment at the China **** Underground Laboratory. The 90\% confidence level upper limits on $κ$ of solar dark photon from 205.4 kg-day exposure are derived, probing new parameter space with masses (${m_V}$) from 10 to 300 eV/…
▽ More
We report constraints on the dark photon effective kinetic mixing parameter ($κ$) with data taken from two ${p}$-type point-contact germanium detectors of the CDEX-10 experiment at the China **** Underground Laboratory. The 90\% confidence level upper limits on $κ$ of solar dark photon from 205.4 kg-day exposure are derived, probing new parameter space with masses (${m_V}$) from 10 to 300 eV/${c^2}$ in direct detection experiments. Considering dark photon as the cosmological dark matter, limits at 90\% confidence level with ${m_V}$ from 0.1 to 4.0 keV/${c^2}$ are set from 449.6 kg-day data, with a minimum of ${\rm{κ=1.3 \times 10^{-15}}}$ at ${\rm{m_V=200\ eV/c^2}}$.
△ Less
Submitted 18 March, 2020; v1 submitted 29 October, 2019;
originally announced October 2019.
-
Performances of a prototype point-contact germanium detector immersed in liquid nitrogen for light dark matter search
Authors:
H. Jiang,
L. T. Yang,
Q. Yue,
K. J. Kang,
J. P. Cheng,
Y. J. Li,
H. T. Wong,
M. Agartioglu,
H. P. An,
J. P. Chang,
J. H. Chen,
Y. H. Chen,
Z. Deng,
Q. Du,
H. Gong,
L. He,
J. W. Hu,
Q. D. Hu,
H. X. Huang,
L. P. Jia,
H. B. Li,
H. Li,
J. M. Li,
J. Li,
X. Li
, et al. (48 additional authors not shown)
Abstract:
The CDEX-10 experiment searches for light weakly-interacting massive particles, a form of dark matter, at the China **** underground laboratory, where approximately 10 kg of germanium detectors are arranged in an array and immersed in liquid nitrogen. Herein, we report on the experimental apparatus, detector characterization, and spectrum analysis of one prototype detector. Owing to the higher…
▽ More
The CDEX-10 experiment searches for light weakly-interacting massive particles, a form of dark matter, at the China **** underground laboratory, where approximately 10 kg of germanium detectors are arranged in an array and immersed in liquid nitrogen. Herein, we report on the experimental apparatus, detector characterization, and spectrum analysis of one prototype detector. Owing to the higher rise-time resolution of the CDEX-10 prototype detector as compared with CDEX-1B, we identified the origin of an observed category of extremely fast events. For data analysis of the CDEX-10 prototype, we introduced and applied an improved bulk/surface event discrimination method. The results of the new method were compared to those of the CDEX-1B spectrum. Both sets of results showed good consistency in the 0--12 keVee energy range, except for the 8.0 keV K-shell X-ray peak from the external copper.
△ Less
Submitted 20 October, 2018;
originally announced October 2018.
-
Limits on Light Weakly Interacting Massive Particles from the First 102.8 kg ${\times}$ day Data of the CDEX-10 Experiment
Authors:
H. Jiang,
L. P. Jia,
Q. Yue,
K. J. Kang,
J. P. Cheng,
Y. J. Li,
H. T. Wong,
M. Agartioglu,
H. P. An,
J. P. Chang,
J. H. Chen,
Y. H. Chen,
Z. Deng,
Q. Du,
H. Gong,
L. He,
J. W. Hu,
Q. D. Hu,
H. X. Huang,
H. B. Li,
H. Li,
J. M. Li,
J. Li,
X. Li,
X. Q. Li
, et al. (48 additional authors not shown)
Abstract:
We report the first results of a light weakly interacting massive particles (WIMPs) search from the CDEX-10 experiment with a 10 kg germanium detector array immersed in liquid nitrogen at the China **** Underground Laboratory with a physics data size of 102.8 kg day. At an analysis threshold of 160 eVee, improved limits of 8 $\times 10^{-42}$ and 3 $\times 10^{-36}$ cm$^{2}$ at a 90\% confidenc…
▽ More
We report the first results of a light weakly interacting massive particles (WIMPs) search from the CDEX-10 experiment with a 10 kg germanium detector array immersed in liquid nitrogen at the China **** Underground Laboratory with a physics data size of 102.8 kg day. At an analysis threshold of 160 eVee, improved limits of 8 $\times 10^{-42}$ and 3 $\times 10^{-36}$ cm$^{2}$ at a 90\% confidence level on spin-independent and spin-dependent WIMP-nucleon cross sections, respectively, at a WIMP mass ($m_χ$) of 5 GeV/${c}^2$ are achieved. The lower reach of $m_χ$ is extended to 2 GeV/${c}^2$.
△ Less
Submitted 26 June, 2018; v1 submitted 25 February, 2018;
originally announced February 2018.
-
Limits on light WIMPs with a 1 kg-scale germanium detector at 160 eVee physics threshold at the China **** Underground Laboratory
Authors:
L. T. Yang,
H. B. Li,
Q. Yue,
K. J. Kang,
J. P. Cheng,
Y. J. Li,
H. T. Wong,
M. Aǧartioǧlu,
H. P. An,
J. P. Chang,
J. H. Chen,
Y. H. Chen,
Z. Deng,
Q. Du,
H. Gong,
L. He,
J. W. Hu,
Q. D. Hu,
H. X. Huang,
L. P. Jia,
H. Jiang,
H. Li,
J. M. Li,
J. Li,
X. Li
, et al. (43 additional authors not shown)
Abstract:
We report results of a search for light weakly interacting massive particle (WIMP) dark matter from the CDEX-1 experiment at the China **** Underground Laboratory (CJPL). Constraints on WIMP-nucleon spin-independent (SI) and spin-dependent (SD) couplings are derived with a physics threshold of 160 eVee, from an exposure of 737.1 kg-days. The SI and SD limits extend the lower reach of light WIMP…
▽ More
We report results of a search for light weakly interacting massive particle (WIMP) dark matter from the CDEX-1 experiment at the China **** Underground Laboratory (CJPL). Constraints on WIMP-nucleon spin-independent (SI) and spin-dependent (SD) couplings are derived with a physics threshold of 160 eVee, from an exposure of 737.1 kg-days. The SI and SD limits extend the lower reach of light WIMPs to 2 GeV and improve over our earlier bounds at WIMP mass less than 6 GeV.
△ Less
Submitted 26 June, 2018; v1 submitted 18 October, 2017;
originally announced October 2017.
-
The Large Enriched Germanium Experiment for Neutrinoless Double Beta Decay (LEGEND)
Authors:
LEGEND Collaboration,
N. Abgrall,
A. Abramov,
N. Abrosimov,
I. Abt,
M. Agostini,
M. Agartioglu,
A. Ajjaq,
S. I. Alvis,
F. T. Avignone III,
X. Bai,
M. Balata,
I. Barabanov,
A. S. Barabash,
P. J. Barton,
L. Baudis,
L. Bezrukov,
T. Bode,
A. Bolozdynya,
D. Borowicz,
A. Boston,
H. Boston,
S. T. P. Boyd,
R. Breier,
V. Brudanin
, et al. (208 additional authors not shown)
Abstract:
The observation of neutrinoless double-beta decay (0$νββ$) would show that lepton number is violated, reveal that neutrinos are Majorana particles, and provide information on neutrino mass. A discovery-capable experiment covering the inverted ordering region, with effective Majorana neutrino masses of 15 - 50 meV, will require a tonne-scale experiment with excellent energy resolution and extremely…
▽ More
The observation of neutrinoless double-beta decay (0$νββ$) would show that lepton number is violated, reveal that neutrinos are Majorana particles, and provide information on neutrino mass. A discovery-capable experiment covering the inverted ordering region, with effective Majorana neutrino masses of 15 - 50 meV, will require a tonne-scale experiment with excellent energy resolution and extremely low backgrounds, at the level of $\sim$0.1 count /(FWHM$\cdot$t$\cdot$yr) in the region of the signal. The current generation $^{76}$Ge experiments GERDA and the MAJORANA DEMONSTRATOR utilizing high purity Germanium detectors with an intrinsic energy resolution of 0.12%, have achieved the lowest backgrounds by over an order of magnitude in the 0$νββ$ signal region of all 0$νββ$ experiments. Building on this success, the LEGEND collaboration has been formed to pursue a tonne-scale $^{76}$Ge experiment. The collaboration aims to develop a phased 0$νββ$ experimental program with discovery potential at a half-life approaching or at $10^{28}$ years, using existing resources as appropriate to expedite physics results.
△ Less
Submitted 6 September, 2017;
originally announced September 2017.
-
Bulk and Surface Event Identification in p-type Germanium Detectors
Authors:
L. T. Yang,
H. B. Li,
H. T. Wong,
M. Agartioglu,
J. H. Chen,
L. P. Jia,
H. Jiang,
J. Li,
F. K. Lin,
S. T. Lin,
S. K. Liu,
J. L. Ma,
B. Sevda,
V. Sharma,
L. Singh,
M. K. Singh,
M. K. Singh,
A. K. Soma,
A. Sonay,
S. W. Yang,
L. Wang,
Q. Wang,
Q. Yue,
W. Zhao
Abstract:
The p-type point-contact germanium detectors have been adopted for light dark matter WIMP searches and the studies of low energy neutrino physics. These detectors exhibit anomalous behavior to events located at the surface layer. The previous spectral shape method to identify these surface events from the bulk signals relies on spectral shape assumptions and the use of external calibration sources…
▽ More
The p-type point-contact germanium detectors have been adopted for light dark matter WIMP searches and the studies of low energy neutrino physics. These detectors exhibit anomalous behavior to events located at the surface layer. The previous spectral shape method to identify these surface events from the bulk signals relies on spectral shape assumptions and the use of external calibration sources. We report an improved method in separating them by taking the ratios among different categories of in situ event samples as calibration sources. Data from CDEX-1 and TEXONO experiments are re-examined using the ratio method. Results are shown to be consistent with the spectral shape method.
△ Less
Submitted 8 January, 2018; v1 submitted 10 November, 2016;
originally announced November 2016.
-
Characterization and Performance of Germanium Detectors with sub-keV Sensitivities for Neutrino and Dark Matter Experiments
Authors:
The TEXONO Collaboration,
A. K. Soma,
M. K. Singh,
L. Singh,
G. Kiran Kumar,
F. K. Lin,
Q. Du,
H. Jiang,
S. K. Liu,
J. L. Ma,
V. Sharma,
L. Wang,
Y. C. Wu,
L. T. Yang,
W. Zhao,
M. Agartioglu,
G. Asryan,
Y. Y. Chang,
J. H. Chen,
Y. C. Chuang,
M. Deniz,
C. L. Hsu,
Y. H. Hsu,
T. R. Huang,
L. P. Jia
, et al. (24 additional authors not shown)
Abstract:
Germanium ionization detectors with sensitivities as low as 100 eVee (electron-equivalent energy) open new windows for studies on neutrino and dark matter physics. The relevant physics subjects are summarized. The detectors have to measure physics signals whose amplitude is comparable to that of pedestal electronic noise. To fully exploit this new detector technique, various experimental issues in…
▽ More
Germanium ionization detectors with sensitivities as low as 100 eVee (electron-equivalent energy) open new windows for studies on neutrino and dark matter physics. The relevant physics subjects are summarized. The detectors have to measure physics signals whose amplitude is comparable to that of pedestal electronic noise. To fully exploit this new detector technique, various experimental issues including quenching factors, energy reconstruction and calibration, signal triggering and selection as well as evaluation of their associated efficiencies have to be attended. The efforts and results of a research program to address these challenges are presented.
△ Less
Submitted 1 September, 2016; v1 submitted 18 November, 2014;
originally announced November 2014.