-
Nonlinear ill-posed problem in low-dose dental cone-beam computed tomography
Authors:
Hyoung Suk Park,
Chang Min Hyun,
** Keun Seo
Abstract:
This paper describes the mathematical structure of the ill-posed nonlinear inverse problem of low-dose dental cone-beam computed tomography (CBCT) and explains the advantages of a deep learning-based approach to the reconstruction of computed tomography images over conventional regularization methods. This paper explains the underlying reasons why dental CBCT is more ill-posed than standard comput…
▽ More
This paper describes the mathematical structure of the ill-posed nonlinear inverse problem of low-dose dental cone-beam computed tomography (CBCT) and explains the advantages of a deep learning-based approach to the reconstruction of computed tomography images over conventional regularization methods. This paper explains the underlying reasons why dental CBCT is more ill-posed than standard computed tomography. Despite this severe ill-posedness, the demand for dental CBCT systems is rapidly growing because of their cost competitiveness and low radiation dose. We then describe the limitations of existing methods in the accurate restoration of the morphological structures of teeth using dental CBCT data severely damaged by metal implants. We further discuss the usefulness of panoramic images generated from CBCT data for accurate tooth segmentation. We also discuss the possibility of utilizing radiation-free intra-oral scan data as prior information in CBCT image reconstruction to compensate for the damage to data caused by metal implants.
△ Less
Submitted 2 March, 2023;
originally announced March 2023.
-
Automatic detection and segmentation of lumbar vertebra from X-ray images for compression fracture evaluation
Authors:
Kang Cheol Kim,
Hyun Cheol Cho,
Tae Jun Jang,
Jong Mun Choi,
** Keun Seo
Abstract:
For compression fracture detection and evaluation, an automatic X-ray image segmentation technique that combines deep-learning and level-set methods is proposed. Automatic segmentation is much more difficult for X-ray images than for CT or MRI images because they contain overlap** shadows of thoracoabdominal structures including lungs, bowel gases, and other bony structures such as ribs. Additio…
▽ More
For compression fracture detection and evaluation, an automatic X-ray image segmentation technique that combines deep-learning and level-set methods is proposed. Automatic segmentation is much more difficult for X-ray images than for CT or MRI images because they contain overlap** shadows of thoracoabdominal structures including lungs, bowel gases, and other bony structures such as ribs. Additional difficulties include unclear object boundaries, the complex shape of the vertebra, inter-patient variability, and variations in image contrast. Accordingly, a structured hierarchical segmentation method is presented that combines the advantages of two deep-learning methods. Pose-driven learning is used to selectively identify the five lumbar vertebra in an accurate and robust manner. With knowledge of the vertebral positions, M-net is employed to segment the individual vertebra. Finally, fine-tuning segmentation is applied by combining the level-set method with the previously obtained segmentation results. The performance of the proposed method was validated using clinical data, resulting in center position detection error of $25.35\pm10.86$ and a mean Dice similarity metric of $91.60\pm2.22\%$.
△ Less
Submitted 16 April, 2019;
originally announced April 2019.
-
Automatic evaluation of fetal head biometry from ultrasound images using machine learning
Authors:
Hwa Pyung Kim,
Sung Min Lee,
Ja-Young Kwon,
Ye** Park,
Kang Cheol Kim,
** Keun Seo
Abstract:
Ultrasound-based fetal biometric measurements, such as head circumference (HC) and biparietal diameter (BPD), are commonly used to evaluate the gestational age and diagnose fetal central nervous system (CNS) pathology. Since manual measurements are operator-dependent and time-consuming, there have been numerous researches on automated methods. However, existing automated methods still are not sati…
▽ More
Ultrasound-based fetal biometric measurements, such as head circumference (HC) and biparietal diameter (BPD), are commonly used to evaluate the gestational age and diagnose fetal central nervous system (CNS) pathology. Since manual measurements are operator-dependent and time-consuming, there have been numerous researches on automated methods. However, existing automated methods still are not satisfactory in terms of accuracy and reliability, owing to difficulties in dealing with various artifacts in ultrasound images. This paper focuses on fetal head biometry and develops a deep-learning-based method for estimating HC and BPD with a high degree of accuracy and reliability. The proposed method effectively identifies the head boundary by differentiating tissue image patterns with respect to the ultrasound propagation direction. The proposed method was trained with 102 labeled data set and tested to 70 ultrasound images. We achieved a success rate of 92.31% for HC and BPD estimations, and an accuracy of 87.14 % for the plane acceptance check.
△ Less
Submitted 18 August, 2018;
originally announced August 2018.
-
Deep learning for undersampled MRI reconstruction
Authors:
Chang Min Hyun,
Hwa Pyung Kim,
Sung Min Lee,
Sungchul Lee,
** Keun Seo
Abstract:
This paper presents a deep learning method for faster magnetic resonance imaging (MRI) by reducing k-space data with sub-Nyquist sampling strategies and provides a rationale for why the proposed approach works well. Uniform subsampling is used in the time-consuming phase-encoding direction to capture high-resolution image information, while permitting the image-folding problem dictated by the Pois…
▽ More
This paper presents a deep learning method for faster magnetic resonance imaging (MRI) by reducing k-space data with sub-Nyquist sampling strategies and provides a rationale for why the proposed approach works well. Uniform subsampling is used in the time-consuming phase-encoding direction to capture high-resolution image information, while permitting the image-folding problem dictated by the Poisson summation formula. To deal with the localization uncertainty due to image folding, very few low-frequency k-space data are added. Training the deep learning net involves input and output images that are pairs of Fourier transforms of the subsampled and fully sampled k-space data. Numerous experiments show the remarkable performance of the proposed method; only 29% of k-space data can generate images of high quality as effectively as standard MRI reconstruction with fully sampled data.
△ Less
Submitted 12 May, 2019; v1 submitted 8 September, 2017;
originally announced September 2017.
-
CT sinogram-consistency learning for metal-induced beam hardening correction
Authors:
Hyung Suk Park,
Sung Min Lee,
Hwa Pyung Kim,
** Keun Seo
Abstract:
This paper proposes a sinogram consistency learning method to deal with beam-hardening related artifacts in polychromatic computerized tomography (CT). The presence of highly attenuating materials in the scan field causes an inconsistent sinogram, that does not match the range space of the Radon transform. When the mismatched data are entered into the range space during CT reconstruction, streakin…
▽ More
This paper proposes a sinogram consistency learning method to deal with beam-hardening related artifacts in polychromatic computerized tomography (CT). The presence of highly attenuating materials in the scan field causes an inconsistent sinogram, that does not match the range space of the Radon transform. When the mismatched data are entered into the range space during CT reconstruction, streaking and shading artifacts are generated owing to the inherent nature of the inverse Radon transform. The proposed learning method aims to repair inconsistent sinograms by removing the primary metal-induced beam-hardening factors along the metal trace in the sinogram. Taking account of the fundamental difficulty in obtaining sufficient training data in a medical environment, the learning method is designed to use simulated training data and a patient-type specific learning model is used to simplify the learning process. The feasibility of the proposed method is investigated using a dataset, consisting of real CT scan of pelvises containing hip prostheses. The anatomical areas in training and test data are different, in order to demonstrate that the proposed method extracts the beam hardening features, selectively. The results show that our method successfully corrects sinogram inconsistency by extracting beam-hardening sources by means of deep learning. This paper proposed a deep learning method of sinogram correction for beam hardening reduction in CT for the first time. Conventional methods for beam hardening reduction are based on regularizations, and have the fundamental drawback of being not easily able to use manifold CT images, while a deep learning approach has the potential to do so.
△ Less
Submitted 12 January, 2018; v1 submitted 2 August, 2017;
originally announced August 2017.
-
Machine-learning-based nonlinear decomposition of CT images for metal artifact reduction
Authors:
Hyung Suk Park,
Sung Min Lee,
Hwa Pyung Kim,
** Keun Seo
Abstract:
Computed tomography (CT) images containing metallic objects commonly show severe streaking and shadow artifacts. Metal artifacts are caused by nonlinear beam-hardening effects combined with other factors such as scatter and Poisson noise. In this paper, we propose an implant-specific method that extracts beam-hardening artifacts from CT images without affecting the background image. We found that…
▽ More
Computed tomography (CT) images containing metallic objects commonly show severe streaking and shadow artifacts. Metal artifacts are caused by nonlinear beam-hardening effects combined with other factors such as scatter and Poisson noise. In this paper, we propose an implant-specific method that extracts beam-hardening artifacts from CT images without affecting the background image. We found that in cases where metal is inserted in the water (or tissue), the generated beam-hardening artifacts can be approximately extracted by subtracting artifacts generated exclusively by metals. We used a deep learning technique to train nonlinear representations of beam-hardening artifacts arising from metals, which appear as shadows and streaking artifacts. The proposed network is not designed to identify ground-truth CT images (i.e., the CT image before its corruption by metal artifacts). Consequently, these images are not required for training. The proposed method was tested on a dataset consisting of real CT scans of pelvises containing simulated hip prostheses. The results demonstrate that the proposed deep learning method successfully extracts both shadowing and streaking artifacts.
△ Less
Submitted 1 August, 2017;
originally announced August 2017.
-
Monotonicity-based Electrical Impedance Tomography for Lung Imaging
Authors:
Liangdong Zhou,
Bastian Harrach,
** Keun Seo
Abstract:
This paper presents a monotonicity-based spatiotemporal conductivity imaging method for continuous regional lung monitoring using electrical impedance tomography (EIT). The EIT data (i.e., the boundary current-voltage data) can be decomposed into pulmonary, cardiac and other parts using their different periodic natures. The time-differential current-voltage operator corresponding to the lung venti…
▽ More
This paper presents a monotonicity-based spatiotemporal conductivity imaging method for continuous regional lung monitoring using electrical impedance tomography (EIT). The EIT data (i.e., the boundary current-voltage data) can be decomposed into pulmonary, cardiac and other parts using their different periodic natures. The time-differential current-voltage operator corresponding to the lung ventilation can be viewed as either semi-positive or semi-negative definite owing to monotonic conductivity changes within the lung regions. We used this monotonicity constraints to improve the quality of lung EIT imaging. We tested the proposed methods in numerical simulations, phantom experiments and human experiments.
△ Less
Submitted 5 February, 2018; v1 submitted 7 February, 2017;
originally announced February 2017.
-
Dipole Incompatibility Related Artifacts in Quantitative Susceptibility Map**
Authors:
Liangdong Zhou,
Jae Kyu Choi,
Youngwook Kee,
Yi Wang,
** Keun Seo
Abstract:
Artifacts in quantitative susceptibility map** (QSM) are analyzed to establish an optimal design criterion for QSM inversion algorithms. The magnetic field data is decomposed into two parts, dipole compatible and incompatible parts. The dipole compatible part generates the desired non-streaking solution. The dipole incompatible part, including noise, discretization error, and anisotropy sources,…
▽ More
Artifacts in quantitative susceptibility map** (QSM) are analyzed to establish an optimal design criterion for QSM inversion algorithms. The magnetic field data is decomposed into two parts, dipole compatible and incompatible parts. The dipole compatible part generates the desired non-streaking solution. The dipole incompatible part, including noise, discretization error, and anisotropy sources, generates artifacts defined by a wave propagator with the B0 field direction as the time axis. Granular noise causes streaking and contiguous error causes both streaking and shadow artifacts. As an example, truncation-based QSM algorithms are inherently prone to streaking artifacts because of the deviation of the dipole kernel during truncation. Through numerical phantom and imaging experiments, several QSM methods, including a Bayesian regularization method and the k-space truncation methods, were compared to show that the Bayesian approach with a structural prior provides advantages in terms of both image quality and quantitative measures.
△ Less
Submitted 18 January, 2017;
originally announced January 2017.
-
Mathematical modeling of mechanical vibration assisted conductivity imaging
Authors:
Habib Ammari,
Eunjung Lee,
Hyeuknam Kwon,
** Keun Seo,
Eung Je Woo
Abstract:
This paper aims at mathematically modeling a new multi-physics conductivity imaging system incorporating mechanical vibrations simultaneously applied to an imaging object together with current injections. We perturb the internal conductivity distribution by applying time-harmonic mechanical vibrations on the boundary. This enhances the effects of any conductivity discontinuity on the induced inter…
▽ More
This paper aims at mathematically modeling a new multi-physics conductivity imaging system incorporating mechanical vibrations simultaneously applied to an imaging object together with current injections. We perturb the internal conductivity distribution by applying time-harmonic mechanical vibrations on the boundary. This enhances the effects of any conductivity discontinuity on the induced internal current density distribution. Unlike other conductivity contrast enhancing frameworks, it does not require a prior knowledge of a reference data. In this paper, we provide a mathematical framework for this novel imaging modality. As an application of the vibration-assisted impedance imaging framework, we propose a new breast image reconstruction method in electrical impedance tomography (EIT). As its another application, we investigate a conductivity anomaly detection problem and provide an efficient location search algorithm. We show both analytically and numerically that the applied mechanical vibration increases the data sensitivity to the conductivity contrast and enhances the quality of reconstructed images and anomaly detection results. For numerous applications in impedance imaging, the proposed multi-physics method opens a new difference imaging area called the vibration-difference imaging, which can augment the time-difference and also frequency-difference imaging methods for sensitivity improvements.
△ Less
Submitted 14 May, 2014;
originally announced May 2014.