-
Quantitative phase microscopies: accuracy comparison
Authors:
Patrick C. Chaumet,
Pierre Bon,
Guillaume Maire,
Anne Sentenac,
Guillaume Baffou
Abstract:
This article presents a thorough comparison of themain QPM techniques, focusing on their accuracy in terms of measurement precision and trueness. We focus on 8 techniques, namely digital holographic microscopy (DHM), cross-grating wavefront microscopy (CGM), which is based on QLSI (quadriwave lateral shearing interferometry), diffraction phase microscopy (DPM), differential phase-contrast (DPC) mi…
▽ More
This article presents a thorough comparison of themain QPM techniques, focusing on their accuracy in terms of measurement precision and trueness. We focus on 8 techniques, namely digital holographic microscopy (DHM), cross-grating wavefront microscopy (CGM), which is based on QLSI (quadriwave lateral shearing interferometry), diffraction phase microscopy (DPM), differential phase-contrast (DPC) microscopy, phase-shifting interferometry (PSI) imaging, Fourier phase microscopy (FPM), spatial light interference microscopy (SLIM), and transport-of-intensity equation (TIE) imaging. For this purpose, we used a home-made numerical toolbox based on discrete dipole approximation (IF-DDA). This toolbox is designed to compute the electromagnetic field at the sample plane of a microscope, irrespective of the object's complexity or the illumination conditions. We upgraded this toolbox to enable it to model any type of QPM, and to take into account shot noise. In a nutshell, the results show that DHM and PSI are inherently free from artefacts and rather suffer from coherent noise; In CGM, DPC, DPM and TIE, there is a trade off between precision and trueness, which can be balanced by varying one experimental parameter; FPM and SLIM suffer from inherent artefacts that cannot be discarded experimentally in most cases, making the techniques not quantitative especially for large objects covering a large part of the field of view, such as eukaryotic cells.
△ Less
Submitted 22 March, 2024; v1 submitted 18 March, 2024;
originally announced March 2024.
-
Super-resolution capacity of variance-based stochastic fluorescence microscopy
Authors:
Simon Labouesse,
Jérôme Idier,
Marc Allain,
Guillaume Giroussens,
Thomas Mangeat,
Anne Sentenac
Abstract:
Improving the resolution of fluorescence microscopy beyond the diffraction limit can be achievedby acquiring and processing multiple images of the sample under different illumination conditions.One of the simplest techniques, Random Illumination Microscopy (RIM), forms the super-resolvedimage from the variance of images obtained with random speckled illuminations. However, thevalidity of this proc…
▽ More
Improving the resolution of fluorescence microscopy beyond the diffraction limit can be achievedby acquiring and processing multiple images of the sample under different illumination conditions.One of the simplest techniques, Random Illumination Microscopy (RIM), forms the super-resolvedimage from the variance of images obtained with random speckled illuminations. However, thevalidity of this process has not been fully theorized. In this work, we characterize mathematicallythe sample information contained in the variance of diffraction-limited speckled images as a functionof the statistical properties of the illuminations. We show that an unambiguous two-fold resolutiongain is obtained when the speckle correlation length coincides with the width of the observationpoint spread function. Last, we analyze the difference between the variance-based techniques usingrandom speckled illuminations (as in RIM) and those obtained using random fluorophore activation(as in Super-resolution Optical Fluctuation Imaging, SOFI).
△ Less
Submitted 23 November, 2023;
originally announced November 2023.
-
Uniqueness of the Random Illumination Microscopy Variance Equation
Authors:
Simon Labouesse,
Jérôme Idier,
Anne Sentenac,
Thomas Mangeat
Abstract:
Recently, it has been shown theoretically that fluorescence microscopy using random illuminations (RIM) yields a doubled lateral resolution and an improved optical sectioning. Moreover, an algorithm called algoRIM, based on variance matching, has been successfully validated on numerous biological applications. Here, we propose a proof of uniqueness of the RIM variance equation, which corresponds t…
▽ More
Recently, it has been shown theoretically that fluorescence microscopy using random illuminations (RIM) yields a doubled lateral resolution and an improved optical sectioning. Moreover, an algorithm called algoRIM, based on variance matching, has been successfully validated on numerous biological applications. Here, we propose a proof of uniqueness of the RIM variance equation, which corresponds to a first theoretical validation of algoRIM.
△ Less
Submitted 11 February, 2021;
originally announced March 2021.
-
Inverse scattering for reflection intensity phase microscopy
Authors:
Alex Matlock,
Anne Sentenac,
Patrick C. Chaumet,
Ji Yi,
Lei Tian
Abstract:
Reflection phase imaging provides label-free, high-resolution characterization of biological samples, typically using interferometric-based techniques. Here, we investigate reflection phase microscopy from intensity-only measurements under diverse illumination. We evaluate the forward and inverse scattering model based on the first Born approximation for imaging scattering objects above a glass sl…
▽ More
Reflection phase imaging provides label-free, high-resolution characterization of biological samples, typically using interferometric-based techniques. Here, we investigate reflection phase microscopy from intensity-only measurements under diverse illumination. We evaluate the forward and inverse scattering model based on the first Born approximation for imaging scattering objects above a glass slide. Under this design, the measured field combines linear forward-scattering and height-dependent nonlinear back-scattering from the object that complicates object phase recovery. Using only the forward-scattering, we derive a linear inverse scattering model and evaluate this model's validity range in simulation and experiment using a standard reflection microscope modified with a programmable light source. Our method provides enhanced contrast of thin, weakly scattering samples that complement transmission techniques. This model provides a promising development for creating simplified intensity-based reflection quantitative phase imaging systems easily adoptable for biological research.
△ Less
Submitted 16 December, 2019;
originally announced December 2019.
-
Approached vectorial model for Fano resonances in guided mode resonance gratings
Authors:
Anne-Laure Fehrembach,
Boris Gralak,
Anne Sentenac
Abstract:
We propose a self-consistent vectorial method, based on a Green's function technique, to describe the Fano resonances that appear in guided mode resonance gratings. The model provides intuitive expressions of the reflectivity and transmittivity matrices of the structure, involving coupling integrals between the modes of a planar reference structure and radiative modes. These expressions are used t…
▽ More
We propose a self-consistent vectorial method, based on a Green's function technique, to describe the Fano resonances that appear in guided mode resonance gratings. The model provides intuitive expressions of the reflectivity and transmittivity matrices of the structure, involving coupling integrals between the modes of a planar reference structure and radiative modes. These expressions are used to derive a physical analysis in configurations where the effect of the incident polarization is not trivial. We provide numerical validations of our model. On a technical point of view, we show how the Green's tensor of our planar reference structure can be expressed as two scalar Green's functions, and how to deal with the singularity of the Green's tensor.
△ Less
Submitted 4 December, 2017; v1 submitted 15 November, 2017;
originally announced November 2017.
-
Joint reconstruction strategy for structured illumination microscopy with unknown illuminations
Authors:
Simon Labouesse,
Awoke Negash,
Jérôme Idier,
Sébastien Bourguignon,
Thomas Mangeat,
Penghuan Liu,
Anne Sentenac,
Marc Allain
Abstract:
The blind structured illumination microscopy (SIM) strategy proposed in (Mudry et al., 1992) is fully re-founded in this paper, unveiling the central role of the sparsity of the illumination patterns in the mechanism that drives super-resolution in the method. A numerical analysis shows that the resolving power of the method can be further enhanced with optimized one-photon or two-photon speckle i…
▽ More
The blind structured illumination microscopy (SIM) strategy proposed in (Mudry et al., 1992) is fully re-founded in this paper, unveiling the central role of the sparsity of the illumination patterns in the mechanism that drives super-resolution in the method. A numerical analysis shows that the resolving power of the method can be further enhanced with optimized one-photon or two-photon speckle illuminations. A much improved numerical implementation is provided for the reconstruction problem under the image positivity constraint. This algorithm rests on a new preconditioned proximal iteration faster than existing solutions, paving the way to 3D and real-time 2D reconstruction
△ Less
Submitted 20 February, 2017; v1 submitted 7 July, 2016;
originally announced July 2016.
-
Blind fluorescence structured illumination microscopy: A new reconstruction strategy
Authors:
S. Labouesse,
M. Allain,
J. Idier,
S. Bourguignon,
A. Negash,
P. Liu,
A. Sentenac
Abstract:
In this communication, a fast reconstruction algorithm is proposed for fluorescence \textit{blind} structured illumination microscopy (SIM) under the sample positivity constraint. This new algorithm is by far simpler and faster than existing solutions, paving the way to 3D and/or real-time 2D reconstruction.
In this communication, a fast reconstruction algorithm is proposed for fluorescence \textit{blind} structured illumination microscopy (SIM) under the sample positivity constraint. This new algorithm is by far simpler and faster than existing solutions, paving the way to 3D and/or real-time 2D reconstruction.
△ Less
Submitted 2 February, 2016; v1 submitted 28 January, 2016;
originally announced January 2016.
-
On the super-resolution capacity of imagers using unknown speckle illuminations
Authors:
Jérôme Idier,
Simon Labouesse,
Marc Allain,
Penghuan Liu,
Sébastien Bourguignon,
Anne Sentenac
Abstract:
Speckle based imaging consists of forming a super-resolved reconstruction of an unknown sample from low-resolution images obtained under random inhomogeneous illuminations (speckles). In a blind context where the illuminations are unknown, we study the intrinsic capacity of speckle-based imagers to recover spatial frequencies outside the frequency support of the data, with minimal assumptions abou…
▽ More
Speckle based imaging consists of forming a super-resolved reconstruction of an unknown sample from low-resolution images obtained under random inhomogeneous illuminations (speckles). In a blind context where the illuminations are unknown, we study the intrinsic capacity of speckle-based imagers to recover spatial frequencies outside the frequency support of the data, with minimal assumptions about the sample. We demonstrate that, under physically realistic conditions, the covariance of the data has a super-resolution power corresponding to the squared magnitude of the imager point spread function. This theoretical result is important for many practical imaging systems such as acoustic and electromagnetic tomographs, fluorescence and photoacoustic microscopes, or synthetic aperture radar imaging. A numerical validation is presented in the case of fluorescence microscopy.
△ Less
Submitted 9 November, 2017; v1 submitted 19 December, 2015;
originally announced December 2015.
-
Super-resolution photoacoustic fluctuation imaging with multiple speckle illumination
Authors:
Thomas Chaigne,
Jérôme Gateau,
Marc Allain,
Ori Katz,
Sylvain Gigan,
Anne Sentenac,
Emmanuel Bossy
Abstract:
In deep tissue photoacoustic imaging, the spatial resolution is inherently limited by acoustic diffraction. Moreover, as the ultrasound attenuation increases with frequency, resolution is often traded-off for penetration depth. Here we report on super-resolution photoacoustic imaging by use of multiple speckle illumination. Specifically, we show that the analysis of second-order fluctuations of th…
▽ More
In deep tissue photoacoustic imaging, the spatial resolution is inherently limited by acoustic diffraction. Moreover, as the ultrasound attenuation increases with frequency, resolution is often traded-off for penetration depth. Here we report on super-resolution photoacoustic imaging by use of multiple speckle illumination. Specifically, we show that the analysis of second-order fluctuations of the photoacoustic images combined with image deconvolution enables resolving optically absorbing structures beyond the acoustic diffraction limit. A resolution increase of almost a factor 2 is demonstrated experimentally. Our method introduces a new framework that could potentially lead to deep tissue photoacoustic imaging with sub-acoustic resolution.
△ Less
Submitted 6 August, 2015;
originally announced August 2015.