-
Fluorescence Imaging of Individual Ions and Molecules in Pressurized Noble Gases for Barium Tagging in $^{136}$Xe
Authors:
NEXT Collaboration,
N. Byrnes,
E. Dey,
F. W. Foss,
B. J. P. Jones,
R. Madigan,
A. McDonald,
R. L. Miller,
K. E. Navarro,
L. R. Norman,
D. R. Nygren,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
F. Auria-Luna,
S. Ayet,
C. D. R. Azevedo,
J. E. Barcelon,
K. Bailey,
F. Ballester,
M. del Barrio-Torregrosa
, et al. (90 additional authors not shown)
Abstract:
The imaging of individual Ba$^{2+}$ ions in high pressure xenon gas is one possible way to attain background-free sensitivity to neutrinoless double beta decay and hence establish the Majorana nature of the neutrino. In this paper we demonstrate selective single Ba$^{2+}$ ion imaging inside a high-pressure xenon gas environment. Ba$^{2+}$ ions chelated with molecular chemosensors are resolved at t…
▽ More
The imaging of individual Ba$^{2+}$ ions in high pressure xenon gas is one possible way to attain background-free sensitivity to neutrinoless double beta decay and hence establish the Majorana nature of the neutrino. In this paper we demonstrate selective single Ba$^{2+}$ ion imaging inside a high-pressure xenon gas environment. Ba$^{2+}$ ions chelated with molecular chemosensors are resolved at the gas-solid interface using a diffraction-limited imaging system with scan area of 1$\times$1~cm$^2$ located inside 10~bar of xenon gas. This new form of microscopy represents an important enabling step in the development of barium tagging for neutrinoless double beta decay searches in $^{136}$Xe, as well as a new tool for studying the photophysics of fluorescent molecules and chemosensors at the solid-gas interface.
△ Less
Submitted 20 May, 2024;
originally announced June 2024.
-
Cryogenic cesium iodide as a potential PET material
Authors:
S. R. Soleti,
A. Castillo,
M. del Barrio-Torregrosa,
C. Echeverria,
M. Seemann,
D. Zerzion,
J. J. Gómez Cadenas
Abstract:
Total-body PET (TB-PET) scanners, with axial lengths exceeding 1 meter, provide significantly higher sensitivity than conventional PET scanners due to their greater acceptance of gamma pairs. However, this increased sensitivity often comes from gamma rays detected at oblique angles, leading to substantial multiple scattering along the patient's body. Additionally, the cost of TB-PET scanners scale…
▽ More
Total-body PET (TB-PET) scanners, with axial lengths exceeding 1 meter, provide significantly higher sensitivity than conventional PET scanners due to their greater acceptance of gamma pairs. However, this increased sensitivity often comes from gamma rays detected at oblique angles, leading to substantial multiple scattering along the patient's body. Additionally, the cost of TB-PET scanners scales with their extended detector length, often costing 5 to 10 times more than conventional scanners. Therefore, optimizing TB-PET performance requires crystals that enhance energy resolution and control costs.
Cesium iodide (CsI), though historically less favored for PET due to its lower stop** power and light yield compared to crystals like LYSO, shows remarkable improvement when operated at cryogenic temperatures ($\sim$100 K). Under these conditions, CsI light yield rises dramatically to about 100 photons/keV, providing excellent energy resolution and good coincidence time resolution at a lower cost - typically 3 to 5 times cheaper than other crystals at parity of radiation length.
In our study, cryogenic CsI crystals achieved an energy resolution better than 7% FWHM at 511 keV and a coincidence time resolution of less than 2 ns. These results demonstrate the potential of cryogenic CsI as a cost-effective, high-performance material for TB-PET scanners.
△ Less
Submitted 19 June, 2024;
originally announced June 2024.
-
Measurement of Energy Resolution with the NEXT-White Silicon Photomultipliers
Authors:
T. Contreras,
B. Palmeiro,
H. Almazán,
A. Para,
G. Martínez-Lema,
R. Guenette,
C. Adams,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
F. Auria-Luna,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
M. del Barrio-Torregrosa,
A. Bayo,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
A. Brodolin,
N. Byrnes,
S. Cárcel,
A. Castillo
, et al. (85 additional authors not shown)
Abstract:
The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and silicon photomultipliers (SiPMs) to extract topology information. This analysis uses $^{83m}\text{Kr}$ data from the NEXT-White detector to measure and understand th…
▽ More
The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and silicon photomultipliers (SiPMs) to extract topology information. This analysis uses $^{83m}\text{Kr}$ data from the NEXT-White detector to measure and understand the energy resolution that can be obtained with the SiPMs, rather than with PMTs. The energy resolution obtained of (10.9 $\pm$ 0.6) $\%$, full-width half-maximum, is slightly larger than predicted based on the photon statistics resulting from very low light detection coverage of the SiPM plane in the NEXT-White detector. The difference in the predicted and measured resolution is attributed to poor corrections, which are expected to be improved with larger statistics. Furthermore, the noise of the SiPMs is shown to not be a dominant factor in the energy resolution and may be negligible when noise subtraction is applied appropriately, for high-energy events or larger SiPM coverage detectors. These results, which are extrapolated to estimate the response of large coverage SiPM planes, are promising for the development of future, SiPM-only, readout planes that can offer imaging and achieve similar energy resolution to that previously demonstrated with PMTs.
△ Less
Submitted 30 May, 2024;
originally announced May 2024.
-
Design, characterization and installation of the NEXT-100 cathode and electroluminescence regions
Authors:
NEXT Collaboration,
K. Mistry,
L. Rogers,
B. J. P. Jones,
B. Munson,
L. Norman,
C. Adams,
H. Almazán,
V. Álvarez,
B. Aparicio,
A. I. Aranburu,
L. Arazi,
I. J. Arnquist,
F. Auria-Luna,
S. Ayet,
C. D. R. Azevedo,
K. Bailey,
F. Ballester,
M. del Barrio-Torregrosa,
A. Bayo,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
A. Brodolin,
N. Byrnes,
S. Cárcel
, et al. (85 additional authors not shown)
Abstract:
NEXT-100 is currently being constructed at the Laboratorio Subterráneo de Canfranc in the Spanish Pyrenees and will search for neutrinoless double beta decay using a high-pressure gaseous time projection chamber (TPC) with 100 kg of xenon. Charge amplification is carried out via electroluminescence (EL) which is the process of accelerating electrons in a high electric field region causing secondar…
▽ More
NEXT-100 is currently being constructed at the Laboratorio Subterráneo de Canfranc in the Spanish Pyrenees and will search for neutrinoless double beta decay using a high-pressure gaseous time projection chamber (TPC) with 100 kg of xenon. Charge amplification is carried out via electroluminescence (EL) which is the process of accelerating electrons in a high electric field region causing secondary scintillation of the medium proportional to the initial charge. The NEXT-100 EL and cathode regions are made from tensioned hexagonal meshes of 1 m diameter. This paper describes the design, characterization, and installation of these parts for NEXT-100. Simulations of the electric field are performed to model the drift and amplification of ionization electrons produced in the detector under various EL region alignments and rotations. Measurements of the electrostatic breakdown voltage in air characterize performance under high voltage conditions and identify breakdown points. The electrostatic deflection of the mesh is quantified and fit to a first-principles mechanical model. Measurements were performed with both a standalone test EL region and with the NEXT-100 EL region before its installation in the detector. Finally, we describe the parts as installed in NEXT-100, following their deployment in Summer 2023.
△ Less
Submitted 21 December, 2023; v1 submitted 6 November, 2023;
originally announced November 2023.
-
Sub-millimetre wave range-Doppler radar as a diagnostic tool for gas-solids systems -- solids concentration measurements
Authors:
Marlene Bonmann,
Diana Carolina Guío-Pérez,
Tomas Bryllert,
David Pallarès,
Martin Seemann,
Filip Johnsson,
Jan Stake
Abstract:
Current non-intrusive measurement techniques for characterising the solids flow in gas-solids suspensions are limited by the low temporal or low spatial resolution of the sample volume, or in the case of optical methods, by a short range of sight. In this work, a sub-millimetre wave range-Doppler radar is developed and validated for non-intrusive sensing of solids concentrations in a gas-solids pa…
▽ More
Current non-intrusive measurement techniques for characterising the solids flow in gas-solids suspensions are limited by the low temporal or low spatial resolution of the sample volume, or in the case of optical methods, by a short range of sight. In this work, a sub-millimetre wave range-Doppler radar is developed and validated for non-intrusive sensing of solids concentrations in a gas-solids particle system with known characteristics. The radar system combines favourable features, such as the ability to see through at optical frequencies opaque materials, to measure the local solids velocity and the reflected radar power with a spatial resolution of a few cubic centimetres over distances of a few metres. This paper introduces a method to relate the received radar signal power to the solids volumetric concentrations (cv) of different particulate materials. The experimental set-up provides a steady stream of free-falling solids that consist of glass spheres, bronze spheres or natural sand grains with known particle size distributions and with particle diameters in the range of 50-300 $μ$m. Thus, the values of cv found using the radar measurements are validated using the values of cv retrieved from closure of the mass balance derived from the measured mass flow rate of the solids stream and the solids velocity. The results show that the radar system provides reliable measurements of cv, with a mean relative error of approximately 25% for all the tested materials, particle sizes and mass flow rates, yielding values of cv ranging from 0.2x10$^{-4}$ m$^{3}$/ m$^{3}$ up to 40x10$^{-4}$ m$^{3}$/ m$^{3}$ and solids velocities within the range of 0-4.5 m/s. This demonstrates the ability of the radar technology to diagnose the solids flow in gas-solids suspensions using a unique combination of penetration length, accuracy, and spatial and velocity resolution.
△ Less
Submitted 4 October, 2022;
originally announced October 2022.