Map** the path to Cryogenic Atom Probe Tomography Analysis of biomolecules
Authors:
Eric V. Woods,
Tim M. Schwarz,
Mahander P. Singh,
Shuo Zhang,
Se-Ho Kim,
Ayman A. El-Zoka,
Lothar Gremer,
Dieter Willbold,
Ingrid McCarroll,
B. Gault
Abstract:
The understanding of protein structure, folding, and interaction with other proteins remains one of the grand challenges of modern biology. Tremendous progress has been made thanks to X-ray- or electron-based techniques that have provided atomic configurations of proteins, and their solvation shell. These techniques though require a large number of similar molecules to provide an average view, and…
▽ More
The understanding of protein structure, folding, and interaction with other proteins remains one of the grand challenges of modern biology. Tremendous progress has been made thanks to X-ray- or electron-based techniques that have provided atomic configurations of proteins, and their solvation shell. These techniques though require a large number of similar molecules to provide an average view, and lack detailed compositional information that might play a major role in the biochemical activity of these macromolecules. Based on its intrinsic performance and recent impact in materials science, atom probe tomography (APT) has been touted as a potential novel tool to analyse biological materials, including proteins. However, analysis of biomolecules in their native, hydrated state by APT have not yet been routinely achieved, and the technique's true capabilities remain to be demonstrated. Here, we present and discuss systematic analyses of individual amino-acids in frozen aqueous solutions on two different nanoporous metal supports across a wide range of analysis conditions. Using a ratio of the molecular ions of water as a descriptor for the conditions of electrostatic field, we study the fragmentation and behavior of those amino acids. We discuss the importance sample support, specimen preparation route, acquisition conditions and data analysis, to pave the way towards establishing guidelines for cryo-APT analysis of biomolecules.
△ Less
Submitted 19 April, 2024;
originally announced April 2024.
-
Nanoporous gold thin films as substrates to analyze liquids by cryo-atom probe tomography
Authors:
E. V. Woods,
A. Saksena,
A. A. El-Zoka,
L. T. Stephenson,
T. M. Schwarz,
M. P. Singh,
L. S. Aota,
S. -H. Kim,
J. Schneider,
B. Gault
Abstract:
Cryogenic atom probe tomography (cryo-APT) is being developed to enable nanoscale compositional analyses of frozen liquids. Yet, the availability of readily available substrates that allow for the fixation of liquids while providing sufficient strength to their interface, is still an issue. Here we propose the use of 1-2 microns thick binary alloy film of gold-silver (AuAg) sputtered onto flat sil…
▽ More
Cryogenic atom probe tomography (cryo-APT) is being developed to enable nanoscale compositional analyses of frozen liquids. Yet, the availability of readily available substrates that allow for the fixation of liquids while providing sufficient strength to their interface, is still an issue. Here we propose the use of 1-2 microns thick binary alloy film of gold-silver (AuAg) sputtered onto flat silicon, with sufficient adhesion without an additional layer. Through chemical dealloying, we successfully fabricate a nanoporous substrate, with open-pore structure, which is mounted on a microarray of Si posts by lift out in the focused-ion beam, allowing for cryogenic fixation of liquids. We present cryo-APT results obtained after cryogenic sharpening, vacuum cryo-transfer and analysis of pure water on top and inside the nanoporous film. We demonstrate that this new substrate has the requisite characteristics for facilitating cryo-APT of frozen liquids, with a relatively lower volume of precious metals. This complete workflow represents an improved approach for frozen liquid analysis, from preparation of the films to the successful fixation of the liquid in the porous network, to cryo-atom probe tomography.
△ Less
Submitted 22 November, 2023;
originally announced November 2023.
-
In-situ metallic coating of atom probe specimen for enhanced yield, performance, and increased field-of-view
Authors:
Tim M. Schwarz,
Eric Woods,
Mahander P. Singh,
Chanwon Jung,
Leonardo S. Aota,
Kyuseon Jang,
Mathias Krämer,
Se-Ho Kim,
Ingrid McCarroll,
Baptiste Gault
Abstract:
Atom probe tomography requires needle-shaped specimens with a diameter typically below 100 nm, making them both very fragile and reactive, and defects (notches at grain boundaries or precipitates) are known to affect the yield and data quality. The use of a conformal coating directly on the sharpened specimen has been proposed to increase yield and reduce background. However, to date, these coatin…
▽ More
Atom probe tomography requires needle-shaped specimens with a diameter typically below 100 nm, making them both very fragile and reactive, and defects (notches at grain boundaries or precipitates) are known to affect the yield and data quality. The use of a conformal coating directly on the sharpened specimen has been proposed to increase yield and reduce background. However, to date, these coatings have been applied ex-situ and mostly are not uniformly. Here, we report on the controlled focused ion beam in-situ deposition of a thin metal film on specimens immediately after specimen preparation. Different metallic targets e.g. Cr were attached to a micromanipulator via a conventional lift-out method and sputtered using the Ga or Xe ions. We showcase the many advantages of coating specimens from metallic to non-metallic materials. We have identified an increase in data quality and yield, an improvement of the mass resolution, as well as an increase in the effective field-of-view enabling visualization of the entire original specimen, including the complete surface oxide layer. The ease of implementation of the approach makes it very attractive for generalizing its use across a very wide range of atom probe analyses.
△ Less
Submitted 17 January, 2024; v1 submitted 14 September, 2023;
originally announced September 2023.
-
A versatile and reproducible cryo-sample preparation methodology for atom probe studies
Authors:
Eric V. Woods,
Mahander P. Singh,
Se-Ho Kim,
Tim M. Schwarz,
James O. Douglas,
Ayman El-Zoka,
Finn Giulani,
Baptiste Gault
Abstract:
Repeatable and reliable site-specific preparation of specimens for atom probe tomography (APT) at cryogenic temperatures has proven challenging. A generalized workflow is required for cryogenic-specimen preparation including lift-out via focused-ion beam and in-situ deposition of cap** layers, to strengthen specimens that will be exposed to high electric field and stresses during field evaporati…
▽ More
Repeatable and reliable site-specific preparation of specimens for atom probe tomography (APT) at cryogenic temperatures has proven challenging. A generalized workflow is required for cryogenic-specimen preparation including lift-out via focused-ion beam and in-situ deposition of cap** layers, to strengthen specimens that will be exposed to high electric field and stresses during field evaporation in APT, and protect them from environment during transfer into the atom probe. Here, we build on existing protocols, and showcase preparation and analysis of a variety of metals, oxides and supported frozen liquids and battery materials. We demonstrate reliable in-situ deposition of a metallic cap** layer that significantly improve the atom probe data quality for challenging material systems, particularly battery cathode materials which are subjected to delithiation during the atom probe analysis itself. Our workflow designed is versatile and transferable widely to other instruments.
△ Less
Submitted 31 March, 2023;
originally announced March 2023.
-
The modular Atom Probe Concept
Authors:
Patrick Stender,
Helena Solodenko,
Andreas Weigel,
Irdi Balla,
Tim Maximilian Schwarz,
Jonas Ott,
Manuel Roussell,
Rüya Duran,
Sebastian Eich,
Mohammad Al-Shakran,
Timo Jacob,
Guido Schmitz
Abstract:
Atomic probe tomography (APT), based on the work of Erwin Mueller, is able to generate three-dimensional chemical maps in atomic resolution. The required instruments for APT have evolved over the last 20 years from an experimental to an established method of materials analysis. Here, we describe the realization of a new instrument concept that allows the direct attachment of APT to a dual beam SEM…
▽ More
Atomic probe tomography (APT), based on the work of Erwin Mueller, is able to generate three-dimensional chemical maps in atomic resolution. The required instruments for APT have evolved over the last 20 years from an experimental to an established method of materials analysis. Here, we describe the realization of a new instrument concept that allows the direct attachment of APT to a dual beam SEM microscope with the main achievement of fast and direct sample transfer. New operational modes are enabled regarding sample geometry, alignment of tips and microelectrode. The instrument is optimized to handle cryo-samples at all stages of preparation and storage. The instrument comes with its own software for evaluation and reconstruction. The performance in terms of mass resolution, aperture angle, and detection efficiency is demonstrated with a few application examples.
△ Less
Submitted 7 May, 2021;
originally announced May 2021.