Skip to main content

Showing 1–13 of 13 results for author: Schury, P

Searching in archive physics. Search in all archives.
.
  1. arXiv:2311.07103  [pdf, other

    physics.ins-det nucl-ex

    Particle Identification at VAMOS++ with Machine Learning Techniques

    Authors: Y. Cho, Y. H. Kim, S. Choi, J. Park, S. Bae, K. I. Hahn, Y. Son, A. Navin, A. Lemasson, M. Rejmund, D. Ramos, D. Ackermann, A. Utepov, C. Fourgeres, J. C. Thomas, J. Goupil, G. Fremont, G. de France, Y. X. Watanabe, Y. Hirayama, S. Jeong, T. Niwase, H. Miyatake, P. Schury, M. Rosenbusch , et al. (23 additional authors not shown)

    Abstract: Multi-nucleon transfer reaction between 136Xe beam and 198Pt target was performed using the VAMOS++ spectrometer at GANIL to study the structure of n-rich nuclei around N=126. Unambiguous charge state identification was obtained by combining two supervised machine learning methods, deep neural network (DNN) and positional correction using a gradient-boosting decision tree (GBDT). The new method re… ▽ More

    Submitted 14 November, 2023; v1 submitted 13 November, 2023; originally announced November 2023.

    Journal ref: Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, Volume 541, August 2023, Pages 240-242

  2. arXiv:2209.12649  [pdf

    physics.ins-det nucl-ex

    Design report of the KISS-II facility for exploring the origin of uranium

    Authors: Takamichi Aoki, Yoshikazu Hirayama, Hironobu Ishiyama, SunChan Jeong, Sota Kimura, Yasuhiro Makida, Hiroari Miyatake, Momo Mukai, Shunji Nishimura, Katsuhisa Nishio, Toshitaka Niwase, Tatsuhiko Ogawa, Hiroki Okuno, Marco Rosenbusch, Peter Schury, Yutaka Watanabe, Michiharu Wada

    Abstract: One of the critical longstanding issues in nuclear physics is the origin of the heavy elements such as platinum and uranium. The r-process hypothesis is generally supported as the process through which heavy elements are formed via explosive rapid neutron capture. Many of the nuclei involved in heavy-element synthesis are unidentified, short-lived, neutron-rich nuclei, and experimental data on the… ▽ More

    Submitted 7 November, 2022; v1 submitted 22 September, 2022; originally announced September 2022.

    Comments: Editors: Yutaka Watanabe and Yoshikazu Hirayama

    Report number: KEK report 2022-2

  3. arXiv:2110.11507  [pdf, ps, other

    physics.ins-det nucl-ex

    The new MRTOF mass spectrograph following the ZeroDegree spectrometer at RIKEN's RIBF facility

    Authors: M. Rosenbusch, M. Wada, S. Chen, A. Takamine, S. Iimura, D. Hou, W. Xian, S. Yan, P. Schury, Y. Hirayama, Y. Ito, H. Ishiyama, S. Kimura, T. Kojima, J. Lee, J. Liu, S. Michimasa, H. Miyatake, M. Mukai, J. Y. Moon, S. Nishimura, S. Naimi, T. Niwase, T. Sonoda, Y. X. Watanabe , et al. (1 additional authors not shown)

    Abstract: A newly assembled multi-reflection time-of-flight mass spectrograph (MRTOF-MS) at RIKEN's RIBF facility became operational for the first time in spring 2020; further modifications and performance tests using stable ions were completed in early 2021. By using a pulsed-drift-tube technique to modify the ions' kinetic energy in a wide range, we directly characterize the dispersion function of the sys… ▽ More

    Submitted 2 November, 2022; v1 submitted 22 October, 2021; originally announced October 2021.

    Comments: 13 pages, 11 figures

  4. arXiv:2007.02688  [pdf, other

    physics.ins-det nucl-ex

    Reduction of contaminants originating from primary beam by improving the beam stoppers in GARIS-II

    Authors: Sota Kimura, Daiya Kaji, Yuta Ito, Hiroari Miyatake, Kouji Morimoto, Peter Schury, Michiharu Wada

    Abstract: Two independent beam stoppers have been developed for improving the beam separation of the gas-filled recoil ion separator GARIS-II. Performance evaluation of these supplemental beam stoppers was performed by using the 208Pb (18O,3n)223Th reaction. A160-fold enhancement of the signal-to-noise ratio at the GARIS-II focal plane was observed.

    Submitted 24 December, 2020; v1 submitted 2 July, 2020; originally announced July 2020.

    Comments: 4 pages, 4 figures

  5. arXiv:1910.10494  [pdf, ps, other

    physics.ins-det nucl-ex

    Accurately accounting for effects on times-of-flight caused by finite field-transition times during the ejection of ions from a storage trap: A study for TOF and MRTOF mass spectrometry

    Authors: M. Rosenbusch, P. Schury, M. Wada, S. Iimura, Y. Ito, H. Wollnik

    Abstract: In applied forms of time-of-flight mass spectrometry utilizing ion storage devices prior to an analysis device, a non instantaneous electric ejection pulse applied in the region of ion storage is used to accelerate ions into the time-of-flight analyzer. The calculated mass value of the ions from the time-of-flight is dependent on the duration of the field transition up to full strength. For novel… ▽ More

    Submitted 27 April, 2020; v1 submitted 22 October, 2019; originally announced October 2019.

    Comments: 14 pages, 9 figures

  6. arXiv:1904.11589  [pdf, ps, other

    physics.ins-det nucl-ex

    Development of an "$α$-ToF" detector for correlated measurement of atomic masses and decay properties

    Authors: T. Niwase, M. Wada, P. Schury, H. Haba, S. Ishizawa, Y. Ito, D. Kaji, S. Kimura, H. Miyatake, K. Morimoto, K. Morita, M. Rosenbusch, H. Wollnik, T. Shanley, Y. Benari

    Abstract: We have developed a novel detector, referred to as an "$α$-ToF detector", for correlated measurements of atomic masses and decay properties of low-yield, short-lived radioactive isotopes using a multi-reflection time-of-flight mass spectrograph. By correlating measured time-of-flight signals with decay events, it will be possible to suppress background events and obtain accurate, high-precision ma… ▽ More

    Submitted 23 April, 2019; originally announced April 2019.

    Comments: 6pages, 10 figures

  7. arXiv:1904.09726  [pdf, other

    physics.ins-det

    An inexpensive biasing system for use in electrostatic steering of ions

    Authors: P. Schury, M. Wada

    Abstract: We introduce a design for an electronic device capable of superposing 8 bias voltages up to $\pm$48V on a voltage of up to 1.5~kV. Such a device has been implemented to provide biasing of a beam steerer-shifter system for use in aligning an ion beam with the optical axis of a multi-reflection time-of-flight mass spectrograph. The device features a 16-bit digital interface both to set and to monito… ▽ More

    Submitted 22 April, 2019; originally announced April 2019.

    Comments: 4 pages, 6 figures, electronics development

  8. arXiv:1904.09596  [pdf, other

    physics.ins-det nucl-ex

    High-stability, high-voltage power supplies for use with multi-reflection time-of-flight mass spectrographs

    Authors: P. Schury, M. Wada, H. Wollnik J-Y. Moon, T. Hashimoto, M. Rosenbusch

    Abstract: Achieving the highest possible mass resolving power in a multi-reflection time-of-flight mass spectrometer requires very high-stability power supplies. To this end, we have developed a programmable high-voltage power supply that can achieve long-term stability on the order of parts-per-million. Herein we present the design of the stable high-voltage system and bench-top stability measurements up t… ▽ More

    Submitted 8 December, 2019; v1 submitted 21 April, 2019; originally announced April 2019.

    Comments: 10 pages, 12 figures, Report of electronics development

  9. arXiv:1805.07023  [pdf, other

    physics.ins-det nucl-ex

    Improving wide-band mass measurements in a multi-reflection time-of-flight mass spectrograph by usage of a concomitant measurement scheme

    Authors: P. Schury, Y. Ito, M. Rosenbusch, H. Miyatake, M. Wada, H. Wollnik

    Abstract: We introduce a new concomitant referencing mode for operating a multi-reflection time-of-flight mass spectrograph (MRTOF-MS), wherein the reference and analyte ions are interleaved on a cycle by cycle bases. Using this mode, we demonstrate an improved technique for performing wide bandwidth mass measurements via MRTOF-MS. This new technique offers a simplified analysis and high-accuracy.

    Submitted 17 May, 2018; originally announced May 2018.

    Comments: 8 pages, 6 figures, follow-up for DOI:10.1016/j.ijms.2013.11.005

  10. arXiv:1310.2077  [pdf, ps, other

    nucl-ex physics.ins-det

    Wide-band mass measurements with a multi-reflection time-of-flight mass spectrograph

    Authors: P. Schury, Y. Ito, M. Wada, H. Wollnik

    Abstract: We characterize the mass bandwidth of the a multi-reflection time-of-flight mass spectrograph, showing both the functional and useful mass bandwidth. We then demonstrate the use of a multi-reflection time-of-flight mass spectrograph to perform mass measurements in mass bands much wider than the mass bandwidth.

    Submitted 14 November, 2013; v1 submitted 8 October, 2013; originally announced October 2013.

    Comments: 8 pages, 9 figures

  11. arXiv:1309.0384  [pdf, other

    physics.ins-det nucl-ex physics.atom-ph

    A novel ion cooling trap for multi-reflection time-of-flight mass spectrograph

    Authors: Y. Ito, P. Schury, M. Wada, S. Naimi, C. Smorra, T. Sonoda, H. Mita, A. Takamine, K. Okada, A. Ozawa, H. Wollnik

    Abstract: A radiofrequency quadrupole ion trap system for use with a multi-reflection time-of-flight mass spectrograph (MRTOF) for short-lived nuclei has been developed. The trap system consists of two different parts, an asymmetric taper trap and a flat trap. The ions are cooled to a sufficient small bunch for precise mass measurement with MRTOF in only 2 ms cooling time in the flat trap, then orthogonally… ▽ More

    Submitted 2 September, 2013; originally announced September 2013.

    Comments: 6 pages

  12. arXiv:1211.1448  [pdf, other

    nucl-ex physics.atom-ph

    An rf-carpet electrospray ion source to provide isobaric mass calibrants for trans-uranium elements

    Authors: S. Naimi, S. Nakamura, Y. Ito, H. Mita, K. Okada, A. Ozawa, P. Schury, T. Sonoda, A. Takamine, M. Wada, H. Wollnik

    Abstract: For trans-uranium elements, stable atomic isobars do not exist. In order to provide isobaric reference ions for the mass measurement of trans-uranium elements, an electrospray ion source (ESI) was combined with an rf-carpet to collect molecular ions efficiently. The rf-carpet allows for simplification of the pum** system to transport ions from the ESI to a precision mass analyzer. Molecular ions… ▽ More

    Submitted 16 December, 2012; v1 submitted 6 November, 2012; originally announced November 2012.

  13. arXiv:1210.6483  [pdf, ps, other

    physics.ins-det nucl-ex

    Development of a resonant laser ionization gas cell for high-energy, short-lived nuclei

    Authors: T. Sonoda, M. Wada, H. Tomita, C. Sakamoto, T. Takatsuka, T. Furukawa, H. Iimura, Y. Ito, T. Kubo, Y. Matsuo, H. Mita, S. Naimi, S. Nakamura, T. Noto, P. Schury, T. Shinozuka, T. Wakui, H. Miyatake, S. Jeong, H. Ishiyama, Y. X. Watanabe, Y. Hirayama, K. Okada, A. Takamine

    Abstract: A new laser ion source configuration based on resonant photoionization in a gas cell has been developed at RIBF RIKEN. This system is intended for the future PArasitic RI-beam production by Laser Ion-Source (PALIS) project which will be installed at RIKEN's fragment separator, BigRIPS. A novel implementation of differential pum**, in combination with a sextupole ion beam guide (SPIG), has been d… ▽ More

    Submitted 24 October, 2012; originally announced October 2012.