-
Light Dark Matter Constraints from SuperCDMS HVeV Detectors Operated Underground with an Anticoincidence Event Selection
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. Alonso-González,
D. W. P. Amaral,
J. Anczarski,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
C. Bathurst,
R. Bhattacharyya,
A. J. Biffl,
P. L. Brink,
M. Buchanan,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
J. -H. Chen
, et al. (115 additional authors not shown)
Abstract:
This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g-days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/$c^2$, as well as upper limits on dark photon k…
▽ More
This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g-days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/$c^2$, as well as upper limits on dark photon kinetic mixing and axion-like particle axioelectric coupling for masses between 1.2 and 23.3 eV/$c^2$. Compared to an earlier HVeV search, sensitivity was improved as a result of an increased overburden of 225 meters of water equivalent, an anticoincidence event selection, and better pile-up rejection. In the case of dark-matter-electron scattering via a heavy mediator, an improvement by up to a factor of 25 in cross-section sensitivity was achieved.
△ Less
Submitted 10 July, 2024;
originally announced July 2024.
-
The Design, Implementation, and Performance of the LZ Calibration Systems
Authors:
J. Aalbers,
D. S. Akerib,
A. K. Al Musalhi,
F. Alder,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
A. Baker,
S. Balashov,
J. Bang,
E. E. Barillier,
J. W. Bargemann,
K. Beattie,
T. Benson,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
E. Bishop,
G. M. Blockinger,
B. Boxer
, et al. (179 additional authors not shown)
Abstract:
LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low e…
▽ More
LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low energy nuclear recoils. Surrounding the TPC, two veto detectors immersed in an ultra-pure water tank enable reducing background events to enhance the discovery potential. Intricate calibration systems are purposely designed to precisely understand the responses of these three detector volumes to various types of particle interactions and to demonstrate LZ's ability to discriminate between signals and backgrounds. In this paper, we present a comprehensive discussion of the key features, requirements, and performance of the LZ calibration systems, which play a crucial role in enabling LZ's WIMP-search and its broad science program. The thorough description of these calibration systems, with an emphasis on their novel aspects, is valuable for future calibration efforts in direct dark matter and other rare-event search experiments.
△ Less
Submitted 20 June, 2024; v1 submitted 2 May, 2024;
originally announced June 2024.
-
The Data Acquisition System of the LZ Dark Matter Detector: FADR
Authors:
J. Aalbers,
D. S. Akerib,
A. K. Al Musalhi,
F. Alder,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
A. Baker,
S. Balashov,
J. Bang,
E. E. Barillier,
J. W. Bargemann,
K. Beattie,
T. Benson,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
E. Bishop,
G. M. Blockinger,
B. Boxer
, et al. (190 additional authors not shown)
Abstract:
The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals.…
▽ More
The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals. This information is used to determine if the digitized waveforms should be preserved for offline analysis.
The system is designed around the Kintex-7 FPGA. In addition to digitizing the PMT signals and providing basic event selection in real time, the flexibility provided by the use of FPGAs allows us to monitor the performance of the detector and the DAQ in parallel to normal data acquisition.
The hardware and software/firmware of this FPGA-based Architecture for Data acquisition and Realtime monitoring (FADR) are discussed and performance measurements are described.
△ Less
Submitted 23 May, 2024;
originally announced May 2024.
-
First measurement of the nuclear-recoil ionization yield in silicon at 100 eV
Authors:
M. F. Albakry,
I. Alkhatib,
D. Alonso,
D. W. P. Amaral,
P. An,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
P. S. Barbeau,
C. Bathurst,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott
, et al. (115 additional authors not shown)
Abstract:
We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4\,keV down to 100\,eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100\,eV. These results call for furthe…
▽ More
We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4\,keV down to 100\,eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100\,eV. These results call for further investigation of the ionization yield theory and a comprehensive determination of the detector response function at energies below the keV scale.
△ Less
Submitted 3 March, 2023;
originally announced March 2023.
-
Background Determination for the LUX-ZEPLIN (LZ) Dark Matter Experiment
Authors:
J. Aalbers,
D. S. Akerib,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
A. Baker,
J. Bang,
J. W. Bargemann,
A. Baxter,
K. Beattie,
P. Beltrame,
E. P. Bernard,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
G. M. Blockinger,
B. Boxer
, et al. (178 additional authors not shown)
Abstract:
The LUX-ZEPLIN experiment recently reported limits on WIMP-nucleus interactions from its initial science run, down to $9.2\times10^{-48}$ cm$^2$ for the spin-independent interaction of a 36 GeV/c$^2$ WIMP at 90% confidence level. In this paper, we present a comprehensive analysis of the backgrounds important for this result and for other upcoming physics analyses, including neutrinoless double-bet…
▽ More
The LUX-ZEPLIN experiment recently reported limits on WIMP-nucleus interactions from its initial science run, down to $9.2\times10^{-48}$ cm$^2$ for the spin-independent interaction of a 36 GeV/c$^2$ WIMP at 90% confidence level. In this paper, we present a comprehensive analysis of the backgrounds important for this result and for other upcoming physics analyses, including neutrinoless double-beta decay searches and effective field theory interpretations of LUX-ZEPLIN data. We confirm that the in-situ determinations of bulk and fixed radioactive backgrounds are consistent with expectations from the ex-situ assays. The observed background rate after WIMP search criteria were applied was $(6.3\pm0.5)\times10^{-5}$ events/keV$_{ee}$/kg/day in the low-energy region, approximately 60 times lower than the equivalent rate reported by the LUX experiment.
△ Less
Submitted 17 July, 2023; v1 submitted 30 November, 2022;
originally announced November 2022.
-
Radon Emanation Techniques and Measurements for LZ
Authors:
N. I. Chott,
R. W. Schnee
Abstract:
Radon emanation was projected to account for $>50$% of the electron recoil background in the WIMP region of interest for the LUX-ZEPLIN (LZ) experiment. To mitigate the amount of radon inside the detector volume, materials with inherently low radioactivity content were selected for LZ construction through an extensive screening campaign. The SD Mines radon emanation system was one of four emanatio…
▽ More
Radon emanation was projected to account for $>50$% of the electron recoil background in the WIMP region of interest for the LUX-ZEPLIN (LZ) experiment. To mitigate the amount of radon inside the detector volume, materials with inherently low radioactivity content were selected for LZ construction through an extensive screening campaign. The SD Mines radon emanation system was one of four emanation facilities utilized to screen materials during construction of LZ. SD Mines also employed a portable radon collection system for equipment too large or delicate to move to a radon emanation facility. This portable system was used to assay the Inner Cryostat Vessel in-situ at various stages of detector construction, resulting in the inference that the titanium cryostat is the source of significant radon emanation. Assays of a $^{228}$Th source confirmed that its $^{222}$Rn emanation is low enough for it to be used, and that 14% of the $^{220}$Rn emanates from the source at room temperature.
△ Less
Submitted 21 November, 2022;
originally announced November 2022.
-
Supporting Capabilities For Underground Facilities
Authors:
Alvine Kamaha,
Brianna Mount,
Richard Schnee
Abstract:
The 2021 particle physics community study, known as "Snowmass 2021", has brought together particle physicists around the world to create a unified vision for the field over the next decade. One of the areas of focus is the Underground Facilities (UF) frontier, which addresses underground infrastructure and the scientific programs and goals of underground-based experiments. To this effect, the UF S…
▽ More
The 2021 particle physics community study, known as "Snowmass 2021", has brought together particle physicists around the world to create a unified vision for the field over the next decade. One of the areas of focus is the Underground Facilities (UF) frontier, which addresses underground infrastructure and the scientific programs and goals of underground-based experiments. To this effect, the UF Supporting Capabilities topical group created two surveys for the community to identify potential gaps between the supporting capabilities of facilities and those needed by current and future experiments. Capabilities surveyed are discussed in this report and include underground cleanroom space size and specifications, radon-reduced space needs and availability, the assay need and other underground space needs as well timeline for future experiments. Results indicate that future, larger experiments will increasingly require underground assembly in larger, cleaner cleanrooms, often with better radon-reduction systems and increased monitoring capability for ambient contaminants. Most assay needs may be met by existing worldwide capabilities with organized cooperation between facilities and experiments. Improved assay sensitivity is needed for assays of bulk and surface radioactivity for some materials for some experiments, and would be highly beneficial for radon emanation.
△ Less
Submitted 15 September, 2022;
originally announced September 2022.
-
Investigating the sources of low-energy events in a SuperCDMS-HVeV detector
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley
, et al. (104 additional authors not shown)
Abstract:
Recent experiments searching for sub-GeV/$c^2$ dark matter have observed event excesses close to their respective energy thresholds. Although specific to the individual technologies, the measured excess event rates have been consistently reported at or below event energies of a few-hundred eV, or with charges of a few electron-hole pairs. In the present work, we operated a 1-gram silicon SuperCDMS…
▽ More
Recent experiments searching for sub-GeV/$c^2$ dark matter have observed event excesses close to their respective energy thresholds. Although specific to the individual technologies, the measured excess event rates have been consistently reported at or below event energies of a few-hundred eV, or with charges of a few electron-hole pairs. In the present work, we operated a 1-gram silicon SuperCDMS-HVeV detector at three voltages across the crystal (0 V, 60 V and 100 V). The 0 V data show an excess of events in the tens of eV region. Despite this event excess, we demonstrate the ability to set a competitive exclusion limit on the spin-independent dark matter--nucleon elastic scattering cross section for dark matter masses of $\mathcal{O}(100)$ MeV/$c^2$, enabled by operation of the detector at 0 V potential and achievement of a very low $\mathcal{O}(10)$ eV threshold for nuclear recoils. Comparing the data acquired at 0 V, 60 V and 100 V potentials across the crystal, we investigated possible sources of the unexpected events observed at low energy. The data indicate that the dominant contribution to the excess is consistent with a hypothesized luminescence from the printed circuit boards used in the detector holder.
△ Less
Submitted 11 October, 2022; v1 submitted 17 April, 2022;
originally announced April 2022.
-
A Strategy for Low-Mass Dark Matter Searches with Cryogenic Detectors in the SuperCDMS SNOLAB Facility
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeno,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley
, et al. (103 additional authors not shown)
Abstract:
The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-ba…
▽ More
The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-based scenarios are forecasted to probe many square decades of unexplored dark matter parameter space below 5 GeV/c$^2$, covering over 6 decades in mass: 1-100 eV/c$^2$ for dark photons and axion-like particles, 1-100 MeV/c$^2$ for dark-photon-coupled light dark matter, and 0.05-5 GeV/c$^2$ for nucleon-coupled dark matter. They will reach the neutrino fog in the 0.5-5 GeV/c$^2$ mass range and test a variety of benchmark models and sharp targets. The novel directions involve greater departures from current SuperCDMS technology but promise even greater reach in the long run, and their development must begin now for them to be available in a timely fashion.
The experienced-based upgrade scenarios rely mainly on dramatic improvements in detector performance based on demonstrated scaling laws and reasonable extrapolations of current performance. Importantly, these improvements in detector performance obviate significant reductions in background levels beyond current expectations for the SuperCDMS SNOLAB experiment. Given that the dominant limiting backgrounds for SuperCDMS SNOLAB are cosmogenically created radioisotopes in the detectors, likely amenable only to isotopic purification and an underground detector life-cycle from before crystal growth to detector testing, the potential cost and time savings are enormous and the necessary improvements much easier to prototype.
△ Less
Submitted 1 April, 2023; v1 submitted 16 March, 2022;
originally announced March 2022.
-
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
Authors:
J. Aalbers,
K. Abe,
V. Aerne,
F. Agostini,
S. Ahmed Maouloud,
D. S. Akerib,
D. Yu. Akimov,
J. Akshat,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
L. Althueser,
C. S. Amarasinghe,
F. D. Amaro,
A. Ames,
T. J. Anderson,
B. Andrieu,
N. Angelides,
E. Angelino,
J. Angevaare,
V. C. Antochi,
D. Antón Martin,
B. Antunovic,
E. Aprile,
H. M. Araújo
, et al. (572 additional authors not shown)
Abstract:
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut…
▽ More
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector.
△ Less
Submitted 4 March, 2022;
originally announced March 2022.
-
Ionization yield measurement in a germanium CDMSlite detector using photo-neutron sources
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen
, et al. (104 additional authors not shown)
Abstract:
Two photo-neutron sources, $^{88}$Y$^{9}$Be and $^{124}$Sb$^{9}$Be, have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. This work evaluates the yield for nuclear recoil energies between 1 keV and 7 keV at a temperature of $\sim$ 50 mK. We use a Geant4 simulation to model the neutron spectrum assuming a charge yie…
▽ More
Two photo-neutron sources, $^{88}$Y$^{9}$Be and $^{124}$Sb$^{9}$Be, have been used to investigate the ionization yield of nuclear recoils in the CDMSlite germanium detectors by the SuperCDMS collaboration. This work evaluates the yield for nuclear recoil energies between 1 keV and 7 keV at a temperature of $\sim$ 50 mK. We use a Geant4 simulation to model the neutron spectrum assuming a charge yield model that is a generalization of the standard Lindhard model and consists of two energy dependent parameters. We perform a likelihood analysis using the simulated neutron spectrum, modeled background, and experimental data to obtain the best fit values of the yield model. The ionization yield between recoil energies of 1 keV and 7 keV is shown to be significantly lower than predicted by the standard Lindhard model for germanium. There is a general lack of agreement among different experiments using a variety of techniques studying the low-energy range of the nuclear recoil yield, which is most critical for interpretation of direct dark matter searches. This suggests complexity in the physical process that many direct detection experiments use to model their primary signal detection mechanism and highlights the need for further studies to clarify underlying systematic effects that have not been well understood up to this point.
△ Less
Submitted 27 June, 2022; v1 submitted 14 February, 2022;
originally announced February 2022.
-
Projected sensitivity of the LUX-ZEPLIN (LZ) experiment to the two-neutrino and neutrinoless double beta decays of $^{134}$Xe
Authors:
The LUX-ZEPLIN,
Collaboration,
:,
D. S. Akerib,
A. K. Al Musalhi,
S. K. Alsum,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araujo,
J. E. Armstrong,
M. Arthurs,
X. Bai,
J. Balajthy,
S. Balashov,
J. Bang,
J. W. Bargemann,
D. Bauer,
A. Baxter,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
A. Bhatti,
A. Biekert
, et al. (172 additional authors not shown)
Abstract:
The projected sensitivity of the LUX-ZEPLIN (LZ) experiment to two-neutrino and neutrinoless double beta decay of $^{134}$Xe is presented. LZ is a 10-tonne xenon time projection chamber optimized for the detection of dark matter particles, that is expected to start operating in 2021 at Sanford Underground Research Facility, USA. Its large mass of natural xenon provides an exceptional opportunity t…
▽ More
The projected sensitivity of the LUX-ZEPLIN (LZ) experiment to two-neutrino and neutrinoless double beta decay of $^{134}$Xe is presented. LZ is a 10-tonne xenon time projection chamber optimized for the detection of dark matter particles, that is expected to start operating in 2021 at Sanford Underground Research Facility, USA. Its large mass of natural xenon provides an exceptional opportunity to search for the double beta decay of $^{134}$Xe, for which xenon detectors enriched in $^{136}$Xe are less effective. For the two-neutrino decay mode, LZ is predicted to exclude values of the half-life up to 1.7$\times$10$^{24}$ years at 90% confidence level (CL), and has a three-sigma observation potential of 8.7$\times$10$^{23}$ years, approaching the predictions of nuclear models. For the neutrinoless decay mode LZ, is projected to exclude values of the half-life up to 7.3$\times$10$^{24}$ years at 90% CL.
△ Less
Submitted 22 November, 2021; v1 submitted 26 April, 2021;
originally announced April 2021.
-
Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals
Authors:
D. S. Akerib,
A. K. Al Musalhi,
S. K. Alsum,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
X. Bai,
J. Balajthy,
S. Balashov,
J. Bang,
J. W. Bargemann,
D. Bauer,
A. Baxter,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
G. M. Blockinger
, et al. (162 additional authors not shown)
Abstract:
Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matt…
▽ More
Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matter and astrophysical neutrinos, which will be applicable to other liquid xenon detectors. The energy threshold is determined by the number of detected S1 photons; typically, these must be recorded in three or more photomultiplier channels to avoid dark count coincidences that mimic real signals. To lower this threshold: a) we take advantage of the double photoelectron emission effect, whereby a single vacuum ultraviolet photon has a $\sim20\%$ probability of ejecting two photoelectrons from a photomultiplier tube photocathode; and b) we drop the requirement of an S1 signal altogether, and use only the ionization signal, which can be detected more efficiently. For both techniques we develop signal and background models for the nominal exposure, and explore accompanying systematic effects, including the dependence on the free electron lifetime in the liquid xenon. When incorporating double photoelectron signals, we predict a factor of $\sim 4$ sensitivity improvement to the dark matter-nucleon scattering cross-section at $2.5$ GeV/c$^2$, and a factor of $\sim1.6$ increase in the solar $^8$B neutrino detection rate. Drop** the S1 requirement may allow sensitivity gains of two orders of magnitude in both cases. Finally, we apply these techniques to even lower masses by taking into account the atomic Migdal effect; this could lower the dark matter particle mass threshold to $80$ MeV/c$^2$.
△ Less
Submitted 21 January, 2021;
originally announced January 2021.
-
Constraints on Lightly Ionizing Particles from CDMSlite
Authors:
SuperCDMS Collaboration,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen
, et al. (93 additional authors not shown)
Abstract:
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved efficient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits calculated using the optimum interval method on the v…
▽ More
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved efficient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits calculated using the optimum interval method on the vertical intensity of cosmogenically-produced LIPs with an electric charge smaller than $e/(3\times10^5$), as well as the strongest limits for charge $\leq e/160$, with a minimum vertical intensity of $1.36\times10^{-7}$\,cm$^{-2}$s$^{-1}$sr$^{-1}$ at charge $e/160$. These results apply over a wide range of LIP masses (5\,MeV/$c^2$ to 100\,TeV/$c^2$) and cover a wide range of $βγ$ values (0.1 -- $10^6$), thus excluding non-relativistic LIPs with $βγ$ as small as 0.1 for the first time.
△ Less
Submitted 19 February, 2022; v1 submitted 18 November, 2020;
originally announced November 2020.
-
Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground
Authors:
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen
, et al. (99 additional authors not shown)
Abstract:
We present limits on spin-independent dark matter-nucleon interactions using a $10.6$ $\mathrm{g}$ Si athermal phonon detector with a baseline energy resolution of $σ_E=3.86 \pm 0.04$ $(\mathrm{stat.})^{+0.19}_{-0.00}$ $(\mathrm{syst.})$ $\mathrm{eV}$. This exclusion analysis sets the most stringent dark matter-nucleon scattering cross-section limits achieved by a cryogenic detector for dark matte…
▽ More
We present limits on spin-independent dark matter-nucleon interactions using a $10.6$ $\mathrm{g}$ Si athermal phonon detector with a baseline energy resolution of $σ_E=3.86 \pm 0.04$ $(\mathrm{stat.})^{+0.19}_{-0.00}$ $(\mathrm{syst.})$ $\mathrm{eV}$. This exclusion analysis sets the most stringent dark matter-nucleon scattering cross-section limits achieved by a cryogenic detector for dark matter particle masses from $93$ to $140$ $\mathrm{MeV}/c^2$, with a raw exposure of $9.9$ $\mathrm{g}\cdot\mathrm{d}$ acquired at an above-ground facility. This work illustrates the scientific potential of detectors with athermal phonon sensors with eV-scale energy resolution for future dark matter searches.
△ Less
Submitted 12 October, 2021; v1 submitted 21 July, 2020;
originally announced July 2020.
-
The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs
Authors:
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
S. Aviles,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame,
J. Bensinger
, et al. (365 additional authors not shown)
Abstract:
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherent…
▽ More
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherently low radioactivity content. The LZ collaboration performed an extensive radioassay campaign over a period of six years to inform material selection for construction and provide an input to the experimental background model against which any possible signal excess may be evaluated. The campaign and its results are described in this paper. We present assays of dust and radon daughters depositing on the surface of components as well as cleanliness controls necessary to maintain background expectations through detector construction and assembly. Finally, examples from the campaign to highlight fixed contaminant radioassays for the LZ photomultiplier tubes, quality control and quality assurance procedures through fabrication, radon emanation measurements of major sub-systems, and bespoke detector systems to assay scintillator are presented.
△ Less
Submitted 28 February, 2022; v1 submitted 3 June, 2020;
originally announced June 2020.
-
Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector
Authors:
SuperCDMS Collaboration,
D. W. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
R. Chen,
N. Chott,
J. Cooley
, et al. (94 additional authors not shown)
Abstract:
This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a…
▽ More
This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 gram-days of exposure acquired in an above-ground laboratory. With charge carrier trap** and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section $\barσ_{e}$ is constrained for dark matter masses from 0.5--$10^{4} $MeV$/c^{2}$; in the mass range from 1.2--50 eV$/c^{2}$ the dark photon kinetic mixing parameter $\varepsilon$ and the axioelectric coupling constant $g_{ae}$ are constrained. The minimum 90% confidence-level upper limits within the above mentioned mass ranges are $\barσ_{e}\,=\,8.7\times10^{-34}$ cm$^{2}$, $\varepsilon\,=\,3.3\times10^{-14}$, and $g_{ae}\,=\,1.0\times10^{-9}$.
△ Less
Submitted 29 January, 2021; v1 submitted 28 May, 2020;
originally announced May 2020.
-
Removal of $^{210}$Pb by Etch of Crystalline Detector Sidewalls
Authors:
Joseph Street,
Rupak Mahapatra,
Eric Morrison,
Mark Platt,
Richard Schnee
Abstract:
A potential source of dominant backgrounds for many rare-event searches or screening detectors is from radon daughters, specifically $^{210}$Pb, deposited on detector surfaces, often during detector fabrication. Performing a late-stage etch is challenging because it may damage the detector. This paper describes a late-stage etching technique that reduces surface $^{210}$Pb and $^{210}$Po by…
▽ More
A potential source of dominant backgrounds for many rare-event searches or screening detectors is from radon daughters, specifically $^{210}$Pb, deposited on detector surfaces, often during detector fabrication. Performing a late-stage etch is challenging because it may damage the detector. This paper describes a late-stage etching technique that reduces surface $^{210}$Pb and $^{210}$Po by $>99\times$ at 90% C.L.
△ Less
Submitted 1 May, 2020;
originally announced May 2020.
-
Simulations of Events for the LUX-ZEPLIN (LZ) Dark Matter Experiment
Authors:
The LUX-ZEPLIN Collaboration,
:,
D. S. Akerib,
C. W. Akerlof,
A. Alqahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
X. Bai,
J. Balajthy,
S. Balashov,
J. Bang,
D. Bauer,
A. Baxter,
J. Bensinger,
E. P. Bernard,
A. Bernstein,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
K. E. Boast
, et al. (173 additional authors not shown)
Abstract:
The LUX-ZEPLIN dark matter search aims to achieve a sensitivity to the WIMP-nucleon spin-independent cross-section down to (1--2)$\times10^{-12}$\,pb at a WIMP mass of 40 GeV/$c^2$. This paper describes the simulations framework that, along with radioactivity measurements, was used to support this projection, and also to provide mock data for validating reconstruction and analysis software. Of par…
▽ More
The LUX-ZEPLIN dark matter search aims to achieve a sensitivity to the WIMP-nucleon spin-independent cross-section down to (1--2)$\times10^{-12}$\,pb at a WIMP mass of 40 GeV/$c^2$. This paper describes the simulations framework that, along with radioactivity measurements, was used to support this projection, and also to provide mock data for validating reconstruction and analysis software. Of particular note are the event generators, which allow us to model the background radiation, and the detector response physics used in the production of raw signals, which can be converted into digitized waveforms similar to data from the operational detector. Inclusion of the detector response allows us to process simulated data using the same analysis routines as developed to process the experimental data.
△ Less
Submitted 23 June, 2020; v1 submitted 25 January, 2020;
originally announced January 2020.
-
The LUX-ZEPLIN (LZ) Experiment
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
J. Barthel,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame
, et al. (357 additional authors not shown)
Abstract:
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient n…
▽ More
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient neutron capture and tagging. LZ is located in the Davis Cavern at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. We describe the major subsystems of the experiment and its key design features and requirements.
△ Less
Submitted 3 November, 2019; v1 submitted 20 October, 2019;
originally announced October 2019.
-
Measurement of the Gamma Ray Background in the Davis Cavern at the Sanford Underground Research Facility
Authors:
D. S. Akerib,
C. W. Akerlof,
S. K. Alsum,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
X. Bai,
J. Balajthy,
S. Balashov,
A. Baxter,
E. P. Bernard,
A. Biekert,
T. P. Biesiadzinski,
K. E. Boast,
B. Boxer,
P. Brás,
J. H. Buckley,
V. V. Bugaev,
S. Burdin,
J. K. Busenitz,
C. Carels,
D. L. Carlsmith,
M. C. Carmona-Benitez,
M. Cascella
, et al. (142 additional authors not shown)
Abstract:
Deep underground environments are ideal for low background searches due to the attenuation of cosmic rays by passage through the earth. However, they are affected by backgrounds from $γ$-rays emitted by $^{40}$K and the $^{238}$U and $^{232}$Th decay chains in the surrounding rock. The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a liquid xenon TPC located with…
▽ More
Deep underground environments are ideal for low background searches due to the attenuation of cosmic rays by passage through the earth. However, they are affected by backgrounds from $γ$-rays emitted by $^{40}$K and the $^{238}$U and $^{232}$Th decay chains in the surrounding rock. The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a liquid xenon TPC located within the Davis campus at the Sanford Underground Research Facility, Lead, South Dakota, at the 4,850-foot level. In order to characterise the cavern background, in-situ $γ$-ray measurements were taken with a sodium iodide detector in various locations and with lead shielding. The integral count rates (0--3300~keV) varied from 596~Hz to 1355~Hz for unshielded measurements, corresponding to a total flux in the cavern of $1.9\pm0.4$~$γ~$cm$^{-2}$s$^{-1}$. The resulting activity in the walls of the cavern can be characterised as $220\pm60$~Bq/kg of $^{40}$K, $29\pm15$~Bq/kg of $^{238}$U, and $13\pm3$~Bq/kg of $^{232}$Th.
△ Less
Submitted 14 November, 2019; v1 submitted 3 April, 2019;
originally announced April 2019.
-
Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood Fit
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
S. Banik,
D. Barker,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
J. Cooley,
B. Cornell,
P. Cushman,
F. De Brienne,
T. Doughty
, et al. (78 additional authors not shown)
Abstract:
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than…
▽ More
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than was used for the two previous CDMSlite data sets. This analysis includes a data "salting" method to protect against bias, improved noise discrimination, background modeling, and the use of profile likelihood methods to search for a dark matter signal in the presence of backgrounds. We achieve an energy threshold of 70 eV and significantly improve the sensitivity for dark matter particles with masses between 2.5 and 10 GeV/c$^2$ compared to previous analyses. We set an upper limit on the dark matter-nucleon scattering cross section in germanium of 5.4$\times$10$^{-42}$ cm$^2$ at 5 GeV/c$^2$, a factor of $\sim$2.5 improvement over the previous CDMSlite result.
△ Less
Submitted 2 January, 2021; v1 submitted 27 August, 2018;
originally announced August 2018.
-
Production Rate Measurement of Tritium and Other Cosmogenic Isotopes in Germanium with CDMSlite
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
D. Barker,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
J. Cooley,
B. Cornell,
P. Cushman,
T. Doughty,
E. Fascione,
E. Figueroa-Feliciano,
C. W. Fink
, et al. (73 additional authors not shown)
Abstract:
Future direct searches for low-mass dark matter particles with germanium detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds from radioactive isotopes activated by cosmogenic radiation inside the germanium. There are limited experimental data available to constrain production rates and a large spread of theoretical predictions. We examine the calculation of expected prod…
▽ More
Future direct searches for low-mass dark matter particles with germanium detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds from radioactive isotopes activated by cosmogenic radiation inside the germanium. There are limited experimental data available to constrain production rates and a large spread of theoretical predictions. We examine the calculation of expected production rates, and analyze data from the second run of the CDMS low ionization threshold experiment (CDMSlite) to estimate the rates for several isotopes. We model the measured CDMSlite spectrum and fit for contributions from tritium and other isotopes. Using the knowledge of the detector history, these results are converted to cosmogenic production rates at sea level. The production rates in atoms/(kg$\cdot$day) are 74$\pm$9 for $^3$H, 1.5$\pm$0.7 for $^{55}$Fe, 17$\pm$5 for $^{65}$Zn, and 30$\pm$18 for $^{68}$Ge.
△ Less
Submitted 16 August, 2019; v1 submitted 19 June, 2018;
originally announced June 2018.
-
Energy Loss Due to Defect Formation from $^{206}$Pb Recoils in SuperCDMS Germanium Detectors
Authors:
Robert Agnese,
Taylor Aralis,
Tsuguo Aramaki,
Isaac Arnquist,
Elham Azadbakht,
William Baker,
Samir Banik,
D'Ann Barker,
Dan Bauer,
Thomas Binder,
Michael Bowles,
Paul Brink,
Ray Bunker,
Blas Cabrera,
Robert Calkins,
Concetta Cartaro,
David Cerdeno,
Yen-Yung Chang,
Jodi Cooley,
Brett Cornell,
Priscilla Cushman,
Philippe Di Stefano,
Todd Doughty,
Eleanor Fascione,
Tali Figueroa
, et al. (72 additional authors not shown)
Abstract:
The Super Cryogenic Dark Matter Search experiment (SuperCDMS) at the Soudan Underground Laboratory studied energy loss associated with Frenkel defect formation in germanium crystals at mK temperatures using in situ $^{210}$Pb sources. We examine the spectrum of $^{206}$Pb nuclear recoils near its expected 103 keV endpoint energy and determine an energy loss of $\left(6.08\pm0.18\right)$ %, which w…
▽ More
The Super Cryogenic Dark Matter Search experiment (SuperCDMS) at the Soudan Underground Laboratory studied energy loss associated with Frenkel defect formation in germanium crystals at mK temperatures using in situ $^{210}$Pb sources. We examine the spectrum of $^{206}$Pb nuclear recoils near its expected 103 keV endpoint energy and determine an energy loss of $\left(6.08\pm0.18\right)$ %, which we attribute to defect formation. From this result and using TRIM simulations, we extract the first experimentally determined average displacement threshold energy of $\left(19.7^{+0.6}_{-0.5}\right)$ eV for germanium. This has implications for the analysis thresholds of future germanium-based dark matter searches.
△ Less
Submitted 16 April, 2019; v1 submitted 24 May, 2018;
originally announced May 2018.
-
First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive Detector
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
S. Banik,
D. Barker,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
Y. -Y. Chang,
J. Cooley,
B. Cornell,
P. Cushman,
P. C. F. Di Stefano,
T. Doughty,
E. Fascione
, et al. (77 additional authors not shown)
Abstract:
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensit…
▽ More
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensitivity to dark photons competitive with other leading approaches but using substantially less exposure (0.49 gram days). These results demonstrate the scientific potential of phonon-mediated semiconductor detectors that are sensitive to single electronic excitations.
△ Less
Submitted 22 December, 2020; v1 submitted 27 April, 2018;
originally announced April 2018.
-
Nuclear-recoil energy scale in CDMS II silicon dark-matter detectors
Authors:
R. Agnese,
A. J. Anderson,
T. Aramaki,
W. Baker,
D. Balakishiyeva,
S. Banik,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
T. Binder,
A. Borgland,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
H. Chagani,
Y. -Y. Chang,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman
, et al. (84 additional authors not shown)
Abstract:
The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absol…
▽ More
The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absolute energy scale for nuclear recoils is necessary to interpret results correctly. The energy scale can be determined in CDMS II silicon detectors using neutrons incident from a broad-spectrum $^{252}$Cf source, taking advantage of a prominent resonance in the neutron elastic scattering cross section of silicon at a recoil (neutron) energy near 20 (182) keV. Results indicate that the phonon collection efficiency for nuclear recoils is $4.8^{+0.7}_{-0.9}$% lower than for electron recoils of the same energy. Comparisons of the ionization signals for nuclear recoils to those measured previously by other groups at higher electric fields indicate that the ionization collection efficiency for CDMS II silicon detectors operated at $\sim$4 V/cm is consistent with 100% for nuclear recoils below 20 keV and gradually decreases for larger energies to $\sim$75% at 100 keV. The impact of these measurements on previously published CDMS II silicon results is small.
△ Less
Submitted 27 July, 2018; v1 submitted 7 March, 2018;
originally announced March 2018.
-
Projected WIMP sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment
Authors:
D. S. Akerib,
C. W. Akerlof,
S. K. Alsum,
H. M. Araújo,
M. Arthurs,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
D. Bauer,
J. Belle,
P. Beltrame,
T. Benson,
E. P. Bernard,
T. P. Biesiadzinski,
K. E. Boast,
B. Boxer,
P. Brás,
J. H. Buckley,
V. V. Bugaev,
S. Burdin,
J. K. Busenitz,
C. Carels,
D. L. Carlsmith,
B. Carlson
, et al. (153 additional authors not shown)
Abstract:
LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector with an active mass of 7~tonnes, LZ will search primarily for low-energy interactions with Weakly Interacting Massive Particles (WIMPs), which are hypothesized to make up…
▽ More
LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector with an active mass of 7~tonnes, LZ will search primarily for low-energy interactions with Weakly Interacting Massive Particles (WIMPs), which are hypothesized to make up the dark matter in our galactic halo. In this paper, the projected WIMP sensitivity of LZ is presented based on the latest background estimates and simulations of the detector.
For a 1000~live day run using a 5.6~tonne fiducial mass, LZ is projected to exclude at 90\% confidence level spin-independent WIMP-nucleon cross sections above $1.4 \times 10^{-48}$~cm$^{2}$ for a 40~$\mathrm{GeV}/c^{2}$ mass WIMP. Additionally, a $5σ$ discovery potential is projected reaching cross sections below the exclusion limits of recent experiments. For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of $2.3 \times 10^{-43}$~cm$^{2}$ ($7.1 \times 10^{-42}$~cm$^{2}$) for a 40~$\mathrm{GeV}/c^{2}$ mass WIMP is expected. With underground installation well underway, LZ is on track for commissioning at SURF in 2020.
△ Less
Submitted 2 December, 2019; v1 submitted 16 February, 2018;
originally announced February 2018.
-
Radon Mitigation for the SuperCDMS SNOLAB Dark Matter Experiment
Authors:
J. Street,
R. Bunker,
E. H. Miller,
R. W. Schnee,
S. Snyder,
J. So
Abstract:
A potential background for the SuperCDMS SNOLAB dark matter experiment is from radon daughters that have plated out onto detector surfaces. To reach desired backgrounds, understanding plate-out rates during detector fabrication as well as mitigating radon in surrounding air is critical. A radon mitigated cleanroom planned at SNOLAB builds upon a system commissioned at the South Dakota School of Mi…
▽ More
A potential background for the SuperCDMS SNOLAB dark matter experiment is from radon daughters that have plated out onto detector surfaces. To reach desired backgrounds, understanding plate-out rates during detector fabrication as well as mitigating radon in surrounding air is critical. A radon mitigated cleanroom planned at SNOLAB builds upon a system commissioned at the South Dakota School of Mines & Technology (SD Mines). The ultra-low radon cleanroom at SD Mines has air supplied by a vacuum-swing-adsorption radon mitigation system that has achieved $>$1000$\times$ reduction for a cleanroom activity consistent with zero and $<0.067\,$Bq$\,$m$^{-3}$ at 90% confidence. Our simulation of this system, validated against calibration data, provides opportunity for increased understanding and optimization for this and future systems.
△ Less
Submitted 28 August, 2017;
originally announced August 2017.
-
Radon Daughter Plate-out onto Teflon
Authors:
Eric S. Morrison,
Eric H. Miller,
Therese Frels,
Richard W. Schnee,
Joseph Street
Abstract:
Radiopure materials for detector components in rare event searches may be contaminated after manufacturing with long-lived $^{210}$Pb produced by the decay of atmospheric radon. Charged radon daughters deposited on the surface or implanted in the bulk of detector materials have the potential to cause noticeable backgrounds within dark matter regions of interest. Understanding the mechanics governi…
▽ More
Radiopure materials for detector components in rare event searches may be contaminated after manufacturing with long-lived $^{210}$Pb produced by the decay of atmospheric radon. Charged radon daughters deposited on the surface or implanted in the bulk of detector materials have the potential to cause noticeable backgrounds within dark matter regions of interest. Understanding the mechanics governing these background signals is therefore a paramount concern in dark matter experiments in order to distinguish a real signal from internal detector backgrounds. Teflon ($i.e.$ PTFE) is a specific material of interest because it makes up the walls of the inner detector of many liquid noble detectors such as the LUX-ZEPLIN experiment. The rate of radon daughter plate-out onto Teflon can be orders of magnitude larger than the plate-out rate onto other materials. Mitigation of plate-out onto Teflon and steel by proximity to other materials is demonstrated.
△ Less
Submitted 28 August, 2017;
originally announced August 2017.
-
Constraining Radon Backgrounds in LZ
Authors:
E. H. Miller,
J. Busenitz,
T. K. Edberg,
C. Ghag,
C. Hall,
R. Leonard,
K. Lesko,
X. Liu,
Yue Meng,
A. Piepke,
R. W. Schnee
Abstract:
The LZ dark matter detector, like many other rare-event searches, will suffer from backgrounds due to the radioactive decay of radon daughters. In order to achieve its science goals, the concentration of radon within the xenon should not exceed $2μ$Bq/kg, or 20 mBq total within its 10 tonnes. The LZ collaboration is in the midst of a program to screen all significant components in contact with the…
▽ More
The LZ dark matter detector, like many other rare-event searches, will suffer from backgrounds due to the radioactive decay of radon daughters. In order to achieve its science goals, the concentration of radon within the xenon should not exceed $2μ$Bq/kg, or 20 mBq total within its 10 tonnes. The LZ collaboration is in the midst of a program to screen all significant components in contact with the xenon. The four institutions involved in this effort have begun sharing two cross-calibration sources to ensure consistent measurement results across multiple distinct devices. We present here five preliminary screening results, some mitigation strategies that will reduce the amount of radon produced by the most problematic components, and a summary of the current estimate of radon emanation throughout the detector. This best estimate totals $<17.3$ mBq, sufficiently low to meet the detector's science goals.
△ Less
Submitted 28 August, 2017;
originally announced August 2017.
-
Low-Mass Dark Matter Search with CDMSlite
Authors:
SuperCDMS Collaboration,
R. Agnese,
A. J. Anderson,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
W. Baker,
D. Balakishiyeva,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
Y. Chang,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell
, et al. (83 additional authors not shown)
Abstract:
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias voltage is…
▽ More
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias voltage is applied to amplify the phonon signals produced by drifting charges. This paper presents studies of the experimental noise and its effect on the achievable energy threshold, which is demonstrated to be as low as 56 eV$_{\text{ee}}$ (electron equivalent energy). The detector-biasing configuration is described in detail, with analysis corrections for voltage variations to the level of a few percent. Detailed studies of the electric-field geometry, and the resulting successful development of a fiducial parameter, eliminate poorly measured events, yielding an energy resolution ranging from ${\sim}$9 eV$_{\text{ee}}$ at 0 keV to 101 eV$_{\text{ee}}$ at ${\sim}$10 eV$_{\text{ee}}$. New results are derived for astrophysical uncertainties relevant to the WIMP-search limits, specifically examining how they are affected by variations in the most probable WIMP velocity and the Galactic escape velocity. These variations become more important for WIMP masses below 10 GeV/$c^2$. Finally, new limits on spin-dependent low-mass WIMP-nucleon interactions are derived, with new parameter space excluded for WIMP masses $\lesssim$3 GeV/$c^2$
△ Less
Submitted 18 January, 2018; v1 submitted 6 July, 2017;
originally announced July 2017.
-
LUX-ZEPLIN (LZ) Technical Design Report
Authors:
B. J. Mount,
S. Hans,
R. Rosero,
M. Yeh,
C. Chan,
R. J. Gaitskell,
D. Q. Huang,
J. Makkinje,
D. C. Malling,
M. Pangilinan,
C. A. Rhyne,
W. C. Taylor,
J. R. Verbus,
Y. D. Kim,
H. S. Lee,
J. Lee,
D. S. Leonard,
J. Li,
J. Belle,
A. Cottle,
W. H. Lippincott,
D. J. Markley,
T. J. Martin,
M. Sarychev,
T. E. Tope
, et al. (237 additional authors not shown)
Abstract:
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
△ Less
Submitted 27 March, 2017;
originally announced March 2017.
-
Identification of Radiopure Titanium for the LZ Dark Matter Experiment and Future Rare Event Searches
Authors:
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
S. K. Alsum,
H. M. Araújo,
I. J. Arnquist,
M. Arthurs,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
M. J. Barry,
J. Belle,
P. Beltrame,
T. Benson,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
K. E. Boast,
A. Bolozdynya,
B. Boxer,
R. Bramante,
P. Brás,
J. H. Buckley,
V. V. Bugaev
, et al. (180 additional authors not shown)
Abstract:
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volume demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals,…
▽ More
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volume demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals, the determination of factors limiting radiopure production, and the selection of titanium for construction of the LZ cryostat and other detector components. This titanium has been measured with activities of $^{238}$U$_{e}$~$<$1.6~mBq/kg, $^{238}$U$_{l}$~$<$0.09~mBq/kg, $^{232}$Th$_{e}$~$=0.28\pm 0.03$~mBq/kg, $^{232}$Th$_{l}$~$=0.25\pm 0.02$~mBq/kg, $^{40}$K~$<$0.54~mBq/kg, and $^{60}$Co~$<$0.02~mBq/kg (68\% CL). Such low intrinsic activities, which are some of the lowest ever reported for titanium, enable its use for future dark matter and other rare event searches. Monte Carlo simulations have been performed to assess the expected background contribution from the LZ cryostat with this radioactivity. In 1,000 days of WIMP search exposure of a 5.6-tonne fiducial mass, the cryostat will contribute only a mean background of $0.160\pm0.001$(stat)$\pm0.030$(sys) counts.
△ Less
Submitted 26 September, 2017; v1 submitted 8 February, 2017;
originally announced February 2017.
-
Projected Sensitivity of the SuperCDMS SNOLAB experiment
Authors:
R. Agnese,
A. J. Anderson,
T. Aramaki,
I. Arnquist,
W. Baker,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
A. Borgland,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeño,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty
, et al. (71 additional authors not shown)
Abstract:
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$ for a dark matter particle…
▽ More
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$ for a dark matter particle mass of 1 GeV/c$^2$, and with capacity to continue exploration to both smaller masses and better sensitivities. The phonon sensitivity of the HV detectors will be sufficient to detect nuclear recoils from sub-GeV dark matter. A detailed calibration of the detector response to low energy recoils will be needed to optimize running conditions of the HV detectors and to interpret their data for dark matter searches. Low-activity shielding, and the depth of SNOLAB, will reduce most backgrounds, but cosmogenically produced $^{3}$H and naturally occurring $^{32}$Si will be present in the detectors at some level. Even if these backgrounds are x10 higher than expected, the science reach of the HV detectors would be over three orders of magnitude beyond current results for a dark matter mass of 1 GeV/c$^2$. The iZIP detectors are relatively insensitive to variations in detector response and backgrounds, and will provide better sensitivity for dark matter particle masses (> 5 GeV/c$^2$). The mix of detector types (HV and iZIP), and targets (germanium and silicon), planned for the experiment, as well as flexibility in how the detectors are operated, will allow us to maximize the low-mass reach, and understand the backgrounds that the experiment will encounter. Upgrades to the experiment, perhaps with a variety of ultra-low-background cryogenic detectors, will extend dark matter sensitivity down to the "neutrino floor", where coherent scatters of solar neutrinos become a limiting background.
△ Less
Submitted 30 September, 2016;
originally announced October 2016.
-
LUX-ZEPLIN (LZ) Conceptual Design Report
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
S. K. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
M. J. Barry,
P. Bauer,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
K. E. Boast,
A. I. Bolozdynya,
E. M. Boulton,
R. Bramante,
J. H. Buckley,
V. V. Bugaev,
R. Bunker,
S. Burdin,
J. K. Busenitz
, et al. (170 additional authors not shown)
Abstract:
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive exp…
▽ More
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive experiment for WIMPs in this mass region by the end of the decade. This report describes in detail the design of the LZ technical systems. Expected backgrounds are quantified and the performance of the experiment is presented. The LZ detector will be located at the Sanford Underground Research Facility in South Dakota. The organization of the LZ Project and a summary of the expected cost and current schedule are given.
△ Less
Submitted 23 September, 2015; v1 submitted 9 September, 2015;
originally announced September 2015.
-
WIMP-Search Results from the Second CDMSlite Run
Authors:
SuperCDMS Collaboration,
R. Agnese,
A. J. Anderson,
T. Aramaki,
M. Asai,
W. Baker,
D. Balakishiyeva,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman,
M. Daal
, et al. (65 additional authors not shown)
Abstract:
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg days, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization…
▽ More
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg days, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization cut reduces backgrounds below those previously reported by CDMSlite. New parameter space for the WIMP-nucleon spin-independent cross section is excluded for WIMP masses between 1.6 and 5.5 GeV/$c^2$.
△ Less
Submitted 9 March, 2016; v1 submitted 8 September, 2015;
originally announced September 2015.
-
Construction and Measurements of an Improved Vacuum-Swing-Adsorption Radon-Mitigation System
Authors:
J. Street,
R. Bunker,
C. Dunagan,
X. Loose,
R. W. Schnee,
M. Stark,
K. Sundarnath,
D. Tronstad
Abstract:
In order to reduce backgrounds from radon-daughter plate-out onto detector surfaces, an ultra-low-radon cleanroom is being commissioned at the South Dakota School of Mines and Technology. An improved vacuum-swing-adsorption radon mitigation system and cleanroom build upon a previous design implemented at Syracuse University that achieved radon levels of $\sim$0.2$\,$Bq$\,$m$^{-3}$. This improved s…
▽ More
In order to reduce backgrounds from radon-daughter plate-out onto detector surfaces, an ultra-low-radon cleanroom is being commissioned at the South Dakota School of Mines and Technology. An improved vacuum-swing-adsorption radon mitigation system and cleanroom build upon a previous design implemented at Syracuse University that achieved radon levels of $\sim$0.2$\,$Bq$\,$m$^{-3}$. This improved system will employ a better pump and larger carbon beds feeding a redesigned cleanroom with an internal HVAC unit and aged water for humidification. With the rebuilt (original) radon mitigation system, the new low-radon cleanroom has already achieved a $>$$\,$300$\times$ reduction from an input activity of $58.6\pm0.7$$\,$Bq$\,$m$^{-3}$ to a cleanroom activity of $0.13\pm0.06$$\,$Bq$\,$m$^{-3}$.
△ Less
Submitted 2 June, 2015;
originally announced June 2015.
-
Maximum Likelihood Analysis of Low Energy CDMS II Germanium Data
Authors:
SuperCDMS Collaboration,
R. Agnese,
A. J. Anderson,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty,
L. Esteban
, et al. (62 additional authors not shown)
Abstract:
We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search (CDMS~II) experiment using a maximum likelihood analysis. A background model is constructed using GEANT4 to simulate the surface-event background from $^{210}$Pb decay-chain events, while using independent calibration data to model the gamma background…
▽ More
We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search (CDMS~II) experiment using a maximum likelihood analysis. A background model is constructed using GEANT4 to simulate the surface-event background from $^{210}$Pb decay-chain events, while using independent calibration data to model the gamma background. Fitting this background model to the data results in no statistically significant WIMP component. In addition, we perform fits using an analytic ad hoc background model proposed by Collar and Fields, who claimed to find a large excess of signal-like events in our data. We confirm the strong preference for a signal hypothesis in their analysis under these assumptions, but excesses are observed in both single- and multiple-scatter events, which implies the signal is not caused by WIMPs, but rather reflects the inadequacy of their background model.
△ Less
Submitted 3 October, 2014;
originally announced October 2014.
-
First direct limits on Lightly Ionizing Particles with electric charge less than $e/6$
Authors:
R. Agnese,
A. J. Anderson,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty,
L. Esteban,
S. Fallows
, et al. (60 additional authors not shown)
Abstract:
While the Standard Model of particle physics does not include free particles with fractional charge, experimental searches have not ruled out their existence. We report results from the Cryogenic Dark Matter Search (CDMS II) experiment that give the first direct-detection limits for cosmogenically-produced relativistic particles with electric charge lower than $e$/6. A search for tracks in the six…
▽ More
While the Standard Model of particle physics does not include free particles with fractional charge, experimental searches have not ruled out their existence. We report results from the Cryogenic Dark Matter Search (CDMS II) experiment that give the first direct-detection limits for cosmogenically-produced relativistic particles with electric charge lower than $e$/6. A search for tracks in the six stacked detectors of each of two of the CDMS II towers found no candidates, thereby excluding new parameter space for particles with electric charges between $e$/6 and $e$/200.
△ Less
Submitted 3 February, 2015; v1 submitted 10 September, 2014;
originally announced September 2014.
-
Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques
Authors:
M. Akashi-Ronquest,
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
M. Bodmer,
M. G. Boulay,
B. Broerman,
B. Buck,
A. Butcher,
B. Cai,
T. Caldwell,
M. Chen,
Y. Chen,
B. Cleveland,
K. Coakley,
K. Dering,
F. A. Duncan,
J. A. Formaggio,
R. Gagnon,
D. Gastler,
F. Giuliani,
M. Gold,
V. V. Golovko,
P. Gorel,
K. Graham
, et al. (57 additional authors not shown)
Abstract:
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We…
▽ More
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We describe a Bayesian technique that can identify the times of individual photoelectrons in a sampled PMT waveform without deconvolution, even when pileup is present. To demonstrate the technique, we apply it to the general problem of particle identification in single-phase liquid argon dark matter detectors. Using the output of the Bayesian photoelectron counting algorithm described in this paper, we construct several test statistics for rejection of backgrounds for dark matter searches in argon. Compared to simpler methods based on either observed charge or peak finding, the photoelectron counting technique improves both energy resolution and particle identification of low energy events in calibration data from the DEAP-1 detector and simulation of the larger MiniCLEAN dark matter detector.
△ Less
Submitted 12 December, 2014; v1 submitted 8 August, 2014;
originally announced August 2014.
-
Removal of long-lived $^{222}$Rn daughters by electropolishing thin layers of stainless steel
Authors:
R. W. Schnee,
M. A. Bowles,
R. Bunker,
K. McCabe,
J. White,
P. Cushman,
M. Pepin,
V. E. Guiseppe
Abstract:
Long-lived alpha and beta emitters in the $^{222}$Rn decay chain on detector surfaces may be the limiting background in many experiments attempting to detect dark matter or neutrinoless double-beta decay. Removal of tens of microns of material via electropolishing has been shown to be effective at removing radon daughters implanted into material surfaces. Some applications, however, require the re…
▽ More
Long-lived alpha and beta emitters in the $^{222}$Rn decay chain on detector surfaces may be the limiting background in many experiments attempting to detect dark matter or neutrinoless double-beta decay. Removal of tens of microns of material via electropolishing has been shown to be effective at removing radon daughters implanted into material surfaces. Some applications, however, require the removal of uniform and significantly smaller thicknesses. Here, we demonstrate that electropolishing < 1 $μ$m from stainless-steel plates reduces the contamination efficiently, by a factor > 100. Examination of electropolished wires with a scanning electron microscope confirms that the thickness removed is reproducible and reasonably uniform. Together, these tests demonstrate the effectiveness of removal of radon daughters for a proposed low-radiation, multi-wire proportional chamber (the BetaCage), without compromising the screener's energy resolution. More generally, electropolishing thin layers of stainless steel may effectively remove radon daughters without compromising precision-machined parts.
△ Less
Submitted 23 April, 2014;
originally announced April 2014.
-
Construction and measurements of a vacuum-swing-adsorption radon-mitigation system
Authors:
R. W. Schnee,
R. Bunker,
G. Ghulam,
D. Jardin,
M. Kos,
A. S. Tenney
Abstract:
Long-lived alpha and beta emitters in the $^{222}$Rn decay chain on (and near) detector surfaces may be the limiting background in many experiments attempting to detect dark matter or neutrinoless double-beta decay, and in screening detectors. In order to reduce backgrounds from radon-daughter plate-out onto the wires of the BetaCage during its assembly, an ultra-low-radon cleanroom is being commi…
▽ More
Long-lived alpha and beta emitters in the $^{222}$Rn decay chain on (and near) detector surfaces may be the limiting background in many experiments attempting to detect dark matter or neutrinoless double-beta decay, and in screening detectors. In order to reduce backgrounds from radon-daughter plate-out onto the wires of the BetaCage during its assembly, an ultra-low-radon cleanroom is being commissioned at Syracuse University using a vacuum-swing-adsorption radon-mitigation system. The radon filter shows ~20$\times$ reduction at its output, from 7.47$\pm$0.56 to 0.37$\pm$0.12 Bq/m$^3$, and the cleanroom radon activity meets project requirements, with a lowest achieved value consistent with that of the filter, and levels consistently < 2 Bq/m$^3$.
△ Less
Submitted 23 April, 2014;
originally announced April 2014.
-
The BetaCage, an ultra-sensitive screener for surface contamination
Authors:
R. Bunker,
Z. Ahmed,
M. A. Bowles,
S. R. Golwala,
D. R. Grant,
M. Kos,
R. H. Nelson,
R. W. Schnee,
A. Rider,
B. Wang,
A. Zahn
Abstract:
Material screening for identifying low-energy electron emitters and alpha-decaying isotopes is now a prerequisite for rare-event searches (e.g., dark-matter direct detection and neutrinoless double-beta decay) for which surface radiocontamination has become an increasingly important background. The BetaCage, a gaseous neon time-projection chamber, is a proposed ultra-sensitive (and nondestructive)…
▽ More
Material screening for identifying low-energy electron emitters and alpha-decaying isotopes is now a prerequisite for rare-event searches (e.g., dark-matter direct detection and neutrinoless double-beta decay) for which surface radiocontamination has become an increasingly important background. The BetaCage, a gaseous neon time-projection chamber, is a proposed ultra-sensitive (and nondestructive) screener for alpha- and beta-emitting surface contaminants to which existing screening facilities are insufficiently sensitive. Sensitivity goals are 0.1 betas per keV-m$^2$-day and 0.1 alphas per m$^2$-day, with the former limited by Compton scattering of photons in the screening samples and (thanks to tracking) the latter expected to be signal-limited; radioassays and simulations indicate backgrounds from detector materials and radon daughters should be subdominant. We report on details of the background simulations and detector design that provide the discrimination, shielding, and radiopurity necessary to reach our sensitivity goals for a chamber with a 95$\times$95 cm$^2$ sample area positioned below a 40 cm drift region and monitored by crisscrossed anode and cathode planes consisting of 151 wires each.
△ Less
Submitted 23 April, 2014;
originally announced April 2014.
-
Update on the MiniCLEAN Dark Matter Experiment
Authors:
K. Rielage,
M. Akashi-Ronquest,
M. Bodmer,
R. Bourque,
B. Buck,
A. Butcher,
T. Caldwell,
Y. Chen,
K. Coakley,
E. Flores,
J. A. Formaggio,
D. Gastler,
F. Giuliani,
M. Gold,
E. Grace,
J. Griego,
N. Guerrero,
V. Guiseppe,
R. Henning,
A. Hime,
S. Jaditz,
C. Kachulis,
E. Kearns,
J. Kelsey,
J. R. Klein
, et al. (21 additional authors not shown)
Abstract:
The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of o…
▽ More
The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of order 50 to 100 tonnes. The liquid cryogen is interchangeable between argon and neon to study the A$^{2}$ dependence of the potential signal and examine backgrounds. MiniCLEAN utilizes a unique modular design with spherical geometry to maximize the light yield using cold photomultiplier tubes in a single-phase detector. Pulse shape discrimination techniques are used to separate nuclear recoil signals from electron recoil backgrounds. MiniCLEAN will be spiked with additional $^{39}$Ar to demonstrate the effective reach of the pulse shape discrimination capability. Assembly of the experiment is underway at SNOLAB and an update on the project is given.
△ Less
Submitted 19 March, 2014;
originally announced March 2014.
-
Search for Low-Mass WIMPs with SuperCDMS
Authors:
R. Agnese,
A. J. Anderson,
M. Asai,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Beaty,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
M. Cherry,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
D. DeVaney
, et al. (70 additional authors not shown)
Abstract:
We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region blinded. Eleven events were observed after unblinding. We set an upper limit on the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2. This result is i…
▽ More
We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region blinded. Eleven events were observed after unblinding. We set an upper limit on the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2. This result is in tension with WIMP interpretations of recent experiments and probes new parameter space for WIMP-nucleon scattering for WIMP masses < 6 GeV/c2.
△ Less
Submitted 12 March, 2014; v1 submitted 28 February, 2014;
originally announced February 2014.
-
Low Background Materials and Assay - A Supplement to the Cosmic Frontier CF1 Summary
Authors:
J. Cooley,
P. Cushman,
E. W. Hoppe,
J. L. Orrell,
R. W. Schnee
Abstract:
This White Paper provides a supplement to the Snowmass Summary from CF1 (Cosmic Frontier WIMP Direct Detection). It was largely prepared during the August 2013 Community Planning Meeting and relies on information gathered from the larger dark matter community. It is a more detailed answer to the CF1 Charge: "Identify the common infrastructure required to meet the scientific and technical goals of…
▽ More
This White Paper provides a supplement to the Snowmass Summary from CF1 (Cosmic Frontier WIMP Direct Detection). It was largely prepared during the August 2013 Community Planning Meeting and relies on information gathered from the larger dark matter community. It is a more detailed answer to the CF1 Charge: "Identify the common infrastructure required to meet the scientific and technical goals of dark matter direct detection." The community as a whole recognizes that sensitive searches for WIMPs require identification, quantification, and procurement of radiopure materials. The lack of sufficient resources in this area is a major project risk for future experiments and can limit scientific reach
△ Less
Submitted 15 November, 2013; v1 submitted 13 November, 2013;
originally announced November 2013.
-
Snowmass CF1 Summary: WIMP Dark Matter Direct Detection
Authors:
P. Cushman,
C. Galbiati,
D. N. McKinsey,
H. Robertson,
T. M. P. Tait,
D. Bauer,
A. Borgland,
B. Cabrera,
F. Calaprice,
J. Cooley,
T. Empl,
R. Essig,
E. Figueroa-Feliciano,
R. Gaitskell,
S. Golwala,
J. Hall,
R. Hill,
A. Hime,
E. Hoppe,
L. Hsu,
E. Hungerford,
R. Jacobsen,
M. Kelsey,
R. F. Lang,
W. H. Lippincott
, et al. (24 additional authors not shown)
Abstract:
As part of the Snowmass process, the Cosmic Frontier WIMP Direct Detection subgroup (CF1) has drawn on input from the Cosmic Frontier and the broader Particle Physics community to produce this document. The charge to CF1 was (a) to summarize the current status and projected sensitivity of WIMP direct detection experiments worldwide, (b) motivate WIMP dark matter searches over a broad parameter spa…
▽ More
As part of the Snowmass process, the Cosmic Frontier WIMP Direct Detection subgroup (CF1) has drawn on input from the Cosmic Frontier and the broader Particle Physics community to produce this document. The charge to CF1 was (a) to summarize the current status and projected sensitivity of WIMP direct detection experiments worldwide, (b) motivate WIMP dark matter searches over a broad parameter space by examining a spectrum of WIMP models, (c) establish a community consensus on the type of experimental program required to explore that parameter space, and (d) identify the common infrastructure required to practically meet those goals.
△ Less
Submitted 3 November, 2013; v1 submitted 30 October, 2013;
originally announced October 2013.
-
CDMSlite: A Search for Low-Mass WIMPs using Voltage-Assisted Calorimetric Ionization Detection in the SuperCDMS Experiment
Authors:
R. Agnese,
A. J. Anderson,
M. Asai,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty,
L. Esteban,
S. Fallows
, et al. (55 additional authors not shown)
Abstract:
SuperCDMS is an experiment designed to directly detect Weakly Interacting Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in the Universe. In this paper, we present WIMP-search results using a calorimetric technique we call CDMSlite, which relies on voltage- assisted Luke-Neganov amplification of the ionization energy deposited by particle interactions. The data were coll…
▽ More
SuperCDMS is an experiment designed to directly detect Weakly Interacting Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in the Universe. In this paper, we present WIMP-search results using a calorimetric technique we call CDMSlite, which relies on voltage- assisted Luke-Neganov amplification of the ionization energy deposited by particle interactions. The data were collected with a single 0.6 kg germanium detector running for 10 live days at the Soudan Underground Laboratory. A low energy threshold of 170 eVee (electron equivalent) was obtained, which allows us to constrain new WIMP-nucleon spin-independent parameter space for WIMP masses below 6 GeV/c2.
△ Less
Submitted 20 December, 2013; v1 submitted 12 September, 2013;
originally announced September 2013.
-
A prototype low-background multiwire proportional chamber for measuring alphas and low-energy betas
Authors:
Z. Ahmed,
M. A. Bowles,
R. Bunker,
S. R. Golwala,
D. R. Grant,
M. Kos,
R. H. Nelson,
A. Rider,
R. W. Schnee,
D. Sotolongo,
B. Wang,
A. Zahn
Abstract:
A prototype multiwire proportional chamber (MWPC) was developed to demonstrate the feasibility of constructing a radiopure time projection chamber with MWPC track readout to assay materials for alpha- and beta-emitting surface contaminants for future rare-event-search experiments as well as other scientific fields. The design features and assembly techniques described here are motivated by the pos…
▽ More
A prototype multiwire proportional chamber (MWPC) was developed to demonstrate the feasibility of constructing a radiopure time projection chamber with MWPC track readout to assay materials for alpha- and beta-emitting surface contaminants for future rare-event-search experiments as well as other scientific fields. The design features and assembly techniques described here are motivated by the position and energy resolution required to reconstruct alpha and beta tracks while efficiently rejecting backgrounds. Results from a test setup using an $^{55}$Fe x-ray source indicate excellent operational stability and a near-ideal energy resolution of 15.8% FWHM at 5.89 keV and a gas gain of $\sim$10$^{4}$.
△ Less
Submitted 24 November, 2013; v1 submitted 23 July, 2013;
originally announced July 2013.
-
Demonstration of Surface Electron Rejection with Interleaved Germanium Detectors for Dark Matter Searches
Authors:
R. Agnese,
A. J. Anderson,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
A. Borgland,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
M. Cherry,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
E. Do Couto E Silva,
T. Doughty,
L. Esteban,
S. Fallows,
E. Figueroa-Feliciano
, et al. (66 additional authors not shown)
Abstract:
The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction, providing excellent discrimination between electron and nuclear recoils, and between surface and interior events. Surface event rejection capabilities were teste…
▽ More
The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction, providing excellent discrimination between electron and nuclear recoils, and between surface and interior events. Surface event rejection capabilities were tested with two $^{210}$Pb sources producing $\sim$130 beta decays/hr. In $\sim$800 live hours, no events leaked into the 8--115 keV signal region, giving upper limit leakage fraction $1.7 \times 10^{-5}$ at 90% C.L., corresponding to $< 0.6$ surface event background in the future 200-kg SuperCDMS SNOLAB experiment.
△ Less
Submitted 4 October, 2013; v1 submitted 10 May, 2013;
originally announced May 2013.