-
Measurement of material isotopics and atom number ratio with alpha-particle spectroscopy for the NIFFTE fission Time Projection Chamber actinide target
Authors:
M. Monterial,
K. T. Schmitt,
C. Prokop,
E. Leal-Cidoncha,
M. Anastasiou,
N. S. Bowden,
J. Bundgaard,
R. J. Casperson,
D. A. Cebra,
T. Classen,
D. H. Dongwi,
N. Fotiades,
J. Gearhart,
V. Geppert-Kleinrath,
U. Greife,
C. Hagmann,
M. Heffner,
D. Hensle,
D. Higgins,
L. D. Isenhower,
K. Kazkaz,
A. Kemnitz,
J. King,
J. L. Klay,
J. Latta
, et al. (15 additional authors not shown)
Abstract:
We present the results of a measurement of isotopic concentrations and atomic number ratio of a double-sided actinide target with alpha-spectroscopy and mass spectrometry. The double-sided actinide target, with primarily Pu-239 on one side and U-235 on the other, was used in the fission Time Projection Chamber (fissionTPC) for a measurement of the neutron-induced fission cross-section ratio betwee…
▽ More
We present the results of a measurement of isotopic concentrations and atomic number ratio of a double-sided actinide target with alpha-spectroscopy and mass spectrometry. The double-sided actinide target, with primarily Pu-239 on one side and U-235 on the other, was used in the fission Time Projection Chamber (fissionTPC) for a measurement of the neutron-induced fission cross-section ratio between the two isotopes. The measured atomic number ratio is intended to provide an absolute normalization of the measured fission cross-section ratio. The Pu-239/U-235 atom number ratio was measured with a combination of mass spectrometry and alpha-spectroscopy with a planar silicon detector with uncertainties of less than 1%.
△ Less
Submitted 9 July, 2021; v1 submitted 10 June, 2021;
originally announced June 2021.
-
1H(n,el) as a Cross Section Reference in a White Source Neutron Beam With the fissionTPC
Authors:
N. I. Walsh,
J. T. Barker,
N. S. Bowden,
K. J. Brewster,
R. J. Casperson,
T. Classen,
N. Fotiadis,
U. Greife,
E. Guardincerri,
C. Hagmann,
M. Heffner,
D. Hensle,
C. R. Hicks,
D. Higgins,
L. D. Isenhower,
A. Kemnitz,
K. J. Kiesling,
J. King,
J. L. Klay,
J. Latta,
W. Loveland,
J. A. Magee,
M. P. Mendenhall,
M. Monterial,
S. Mosby
, et al. (11 additional authors not shown)
Abstract:
We provide a quantitative description of a method to measure neutron-induced fission cross sections in ratio to elastic hydrogen scattering in a white-source neutron beam with the fission Time Projection Chamber. This detector has measured precision fission cross section ratios using actinide references such as $^{235}$U(n,f) and $^{238}$U(n,f). However, by employing a more precise reference such…
▽ More
We provide a quantitative description of a method to measure neutron-induced fission cross sections in ratio to elastic hydrogen scattering in a white-source neutron beam with the fission Time Projection Chamber. This detector has measured precision fission cross section ratios using actinide references such as $^{235}$U(n,f) and $^{238}$U(n,f). However, by employing a more precise reference such as the H(n,el) cross section there is the potential to further reduce the evaluation uncertainties of the measured cross sections. In principle the fissionTPC could provide a unique measurement by simultaneously measuring both fission fragments and proton recoils over a large solid angle. We investigate one method with a hydrogenous gas target and with the neutron energy determined by the proton recoil kinematics. This method enables the measurement to be performed in a white-source neutron beam and with the current configuration of the fissionTPC. We show that while such a measurement is feasible in the energy range of 0.5 MeV to $\sim$10 MeV, uncertainties on the proton detection efficiency and the neutron energy resolution do not allow us to preform a fission ratio measurement to the desired precision. Utilizing either a direct measurement of the neutron time-of-flight for the recoil proton or a mono-energetic neutron source or some combination of both would provide a path to a sub-percent precision measurement.
△ Less
Submitted 23 April, 2019;
originally announced April 2019.
-
Measurement of the normalized $^{238}$U(n,f)/$^{235}$U(n,f) cross section ratio from threshold to 30 MeV with the fission Time Projection Chamber
Authors:
R. J. Casperson,
D. M. Asner,
J. Baker,
R. G. Baker,
J. S. Barrett,
N. S. Bowden,
C. Brune,
J. Bundgaard,
E. Burgett,
D. A. Cebra,
T. Classen,
M. Cunningham,
J. Deaven,
D. L. Duke,
I. Ferguson,
J. Gearhart,
V. Geppert-Kleinrath,
U. Greife,
S. Grimes,
E. Guardincerri,
U. Hager,
C. Hagmann,
M. Heffner,
D. Hensle,
N. Hertel
, et al. (39 additional authors not shown)
Abstract:
The normalized $^{238}$U(n,f)/$^{235}$U(n,f) cross section ratio has been measured using the NIFFTE fission Time Projection Chamber from the reaction threshold to $30$~MeV. The fissionTPC is a two-volume MICROMEGAS time projection chamber that allows for full three-dimensional reconstruction of fission-fragment ionization profiles from neutron-induced fission. The measurement was performed at the…
▽ More
The normalized $^{238}$U(n,f)/$^{235}$U(n,f) cross section ratio has been measured using the NIFFTE fission Time Projection Chamber from the reaction threshold to $30$~MeV. The fissionTPC is a two-volume MICROMEGAS time projection chamber that allows for full three-dimensional reconstruction of fission-fragment ionization profiles from neutron-induced fission. The measurement was performed at the Los Alamos Neutron Science Center, where the neutron energy is determined from neutron time-of-flight. The $^{238}$U(n,f)/$^{235}$U(n,f) ratio reported here is the first cross section measurement made with the fissionTPC, and will provide new experimental data for evaluation of the $^{238}$U(n,f) cross section, an important standard used in neutron-flux measurements. Use of a development target in this work prevented the determination of an absolute normalization, to be addressed in future measurements. Instead, the measured cross section ratio has been normalized to ENDF/B-VIII.$β$5 at 14.5 MeV.
△ Less
Submitted 23 February, 2018;
originally announced February 2018.
-
Performance of a MICROMEGAS-based TPC in a high-energy neutron beam
Authors:
Lucas Snyder,
Brett Manning,
Nathaniel S. Bowden,
Jeremy Bundgaard,
Robert J. Casperson,
Daniel A. Cebra,
Timothy Classen,
Dana L. Duke,
Joshua Gearhart,
Uwe Greife,
Christian Hagmann,
Michael Heffner,
David Hensle,
Daniel Higgins,
Donald Isenhower,
Jonathan King,
Jennifer L. Klay,
Verena Geppert-Kleinrath,
Walter Loveland,
Joshua A. Magee,
Michael P. Mendenhall,
Samuele Sangiorgio,
Brandon Seilhan,
Kyle T. Schmitt,
Fredrik Tovesson
, et al. (5 additional authors not shown)
Abstract:
The MICROMEGAS (MICRO-MEsh GAseous Structure) charge amplification structure has found wide use in many detection applications, especially as a gain stage for the charge readout of Time Projection Chambers (TPCs). Here we report on the behavior of a MICROMEGAS TPC when operated in a high-energy (up to 800 MeV) neutron beam. It is found that neutron-induced reactions can cause discharges in some dr…
▽ More
The MICROMEGAS (MICRO-MEsh GAseous Structure) charge amplification structure has found wide use in many detection applications, especially as a gain stage for the charge readout of Time Projection Chambers (TPCs). Here we report on the behavior of a MICROMEGAS TPC when operated in a high-energy (up to 800 MeV) neutron beam. It is found that neutron-induced reactions can cause discharges in some drift gas mixtures that are stable in the absence of the neutron beam. The discharges result from recoil ions close to the MICROMEGAS that deposit high specific ionization density and have a limited diffusion time. For a binary drift gas, increasing the percentage of the molecular component (quench gas) relative to the noble component and operating at lower pressures generally improves stability.
△ Less
Submitted 4 December, 2017;
originally announced December 2017.
-
Tracking rare-isotope beams with microchannel plates
Authors:
A. M. Rogers,
A. Sanetullaev,
W. G. Lynch,
M. B. Tsang,
J. Lee,
D. Bazin,
D. Coupland,
V. Henzl,
D. Henzlova,
M. Kilburn,
M. S. Wallace,
M. Youngs,
F. Delaunay,
M. Famiano,
D. Shapira,
K. L. Jones,
K. T. Schmitt,
Z. Y. Sun
Abstract:
A system of two microchannel-plate detectors has been successfully implemented for tracking projectile-fragmentation beams. The detectors provide interaction positions, angles, and arrival times of ions at the reaction target. The current design is an adaptation of an assembly used for low-energy beams ($\sim$1.4 MeV/nucleon). In order to improve resolution in tracking high-energy heavy-ion beams,…
▽ More
A system of two microchannel-plate detectors has been successfully implemented for tracking projectile-fragmentation beams. The detectors provide interaction positions, angles, and arrival times of ions at the reaction target. The current design is an adaptation of an assembly used for low-energy beams ($\sim$1.4 MeV/nucleon). In order to improve resolution in tracking high-energy heavy-ion beams, the magnetic field strength between the secondary-electron accelerating foil and the microchannel plate had to be increased substantially. Results from an experiment using a 37-MeV/nucleon ${}^{56}$Ni beam show that the tracking system can achieve sub-nanosecond timing resolution and a position resolution of $\sim$1 mm for beam intensities up to $5\times10^{5}$ pps.
△ Less
Submitted 11 September, 2013;
originally announced September 2013.