-
Recommendations and guidelines from the ISMRM Diffusion Study Group for preclinical diffusion MRI: Part 2 -- Ex vivo imaging
Authors:
Kurt G Schilling,
Francesco Grussu,
Andrada Ianus,
Brian Hansen,
Rachel L C Barrett,
Manisha Aggarwal,
Stijn Michielse,
Fatima Nasrallah,
Warda Syeda,
Nian Wang,
Jelle Veraart,
Alard Roebroeck,
Andrew F Bagdasarian,
Cornelius Eichner,
Farshid Sepehrband,
Jan Zimmermann,
Lucas Soustelle,
Christien Bowman,
Benjamin C Tendler,
Andreea Hertanu,
Ben Jeurissen,
Lucio Frydman,
Yohan van de Looij,
David Hike,
Jeff F Dunn
, et al. (31 additional authors not shown)
Abstract:
The value of preclinical diffusion MRI (dMRI) is substantial. While dMRI enables in vivo non-invasive characterization of tissue, ex vivo dMRI is increasingly being used to probe tissue microstructure and brain connectivity. Ex vivo dMRI has several experimental advantages including higher signal-to-noise ratio and spatial resolution compared to in vivo studies, and more advanced diffusion contras…
▽ More
The value of preclinical diffusion MRI (dMRI) is substantial. While dMRI enables in vivo non-invasive characterization of tissue, ex vivo dMRI is increasingly being used to probe tissue microstructure and brain connectivity. Ex vivo dMRI has several experimental advantages including higher signal-to-noise ratio and spatial resolution compared to in vivo studies, and more advanced diffusion contrasts for improved microstructure and connectivity characterization. Another major advantage is direct comparison with histological data as a crucial methodological validation. However, there are a number of considerations that must be made when performing ex vivo experiments. The steps from tissue preparation, image acquisition and processing, and interpretation of results are complex, with many decisions that not only differ dramatically from in vivo imaging, but ultimately affect what questions can be answered using the data. This work represents 'Part 2' of a series of recommendations and considerations for preclinical dMRI, where we focus on best practices for dMRI of ex vivo tissue. We first describe the value that ex vivo imaging adds to the field of dMRI, followed by general considerations and foundational knowledge that must be considered when designing experiments. We then give guidelines for ex vivo protocols, including tissue preparation, imaging sequences and data processing including pre-processing, model-fitting, and tractography. Finally, we provide an online resource which lists publicly available ex vivo dMRI datasets and dedicated software packages. In each section, we attempt to provide guidelines and recommendations, but also highlight areas for which no guidelines exist, and where future work should lie. An overarching goal herein is to enhance the rigor and reproducibility of ex vivo dMRI acquisitions and analyses, and thereby advance biomedical knowledge.
△ Less
Submitted 7 February, 2023; v1 submitted 27 September, 2022;
originally announced September 2022.
-
Recommendations and guidelines from the ISMRM Diffusion Study Group for preclinical diffusion MRI: Part 1 -- In vivo small-animal imaging
Authors:
Ileana O Jelescu,
Francesco Grussu,
Andrada Ianus,
Brian Hansen,
Rachel L C Barrett,
Manisha Aggarwal,
Stijn Michielse,
Fatima Nasrallah,
Warda Syeda,
Nian Wang,
Jelle Veraart,
Alard Roebroeck,
Andrew F Bagdasarian,
Cornelius Eichner,
Farshid Sepehrband,
Jan Zimmermann,
Lucas Soustelle,
Christien Bowman,
Benjamin C Tendler,
Andreea Hertanu,
Ben Jeurissen,
Marleen Verhoye,
Lucio Frydman,
Yohan van de Looij,
David Hike
, et al. (32 additional authors not shown)
Abstract:
The value of in vivo preclinical diffusion MRI (dMRI) is substantial. Small-animal dMRI has been used for methodological development and validation, characterizing the biological basis of diffusion phenomena, and comparative anatomy. Many of the influential works in this field were first performed in small animals or ex vivo samples. The steps from animal setup and monitoring, to acquisition, anal…
▽ More
The value of in vivo preclinical diffusion MRI (dMRI) is substantial. Small-animal dMRI has been used for methodological development and validation, characterizing the biological basis of diffusion phenomena, and comparative anatomy. Many of the influential works in this field were first performed in small animals or ex vivo samples. The steps from animal setup and monitoring, to acquisition, analysis, and interpretation are complex, with many decisions that may ultimately affect what questions can be answered using the data. This work aims to serve as a reference, presenting selected recommendations and guidelines from the diffusion community, on best practices for preclinical dMRI of in vivo animals. In each section, we also highlight areas for which no guidelines exist (and why), and where future work should focus. We first describe the value that small animal imaging adds to the field of dMRI, followed by general considerations and foundational knowledge that must be considered when designing experiments. We briefly describe differences in animal species and disease models and discuss how they are appropriate for different studies. We then give guidelines for in vivo acquisition protocols, including decisions on hardware, animal preparation, imaging sequences and data processing, including pre-processing, model-fitting, and tractography. Finally, we provide an online resource which lists publicly available preclinical dMRI datasets and software packages, to promote responsible and reproducible research. An overarching goal herein is to enhance the rigor and reproducibility of small animal dMRI acquisitions and analyses, and thereby advance biomedical knowledge.
△ Less
Submitted 21 April, 2023; v1 submitted 26 September, 2022;
originally announced September 2022.
-
Stable and high quality electron beams from staged laser and plasma wakefield accelerators
Authors:
F. M. Foerster,
A. Döpp,
F. Haberstroh,
K. v. Grafenstein,
D. Campbell,
Y. -Y. Chang,
S. Corde,
J. P. Couperus Cabadağ,
A. Debus,
M. F. Gilljohann,
A. F. Habib,
T. Heinemann,
B. Hidding,
A. Irman,
F. Irshad,
A. Knetsch,
O. Kononenko,
A. Martinez de la Ossa,
A. Nutter,
R. Pausch,
G. Schilling,
A. Schletter,
S. Schöbel,
U. Schramm,
E. Travac
, et al. (2 additional authors not shown)
Abstract:
We present experimental results on a plasma wakefield accelerator (PWFA) driven by high-current electron beams from a laser wakefield accelerator (LWFA). In this staged setup stable and high quality (low divergence and low energy spread) electron beams are generated at an optically-generated hydrodynamic shock in the PWFA. The energy stability of the beams produced by that arrangement in the PWFA…
▽ More
We present experimental results on a plasma wakefield accelerator (PWFA) driven by high-current electron beams from a laser wakefield accelerator (LWFA). In this staged setup stable and high quality (low divergence and low energy spread) electron beams are generated at an optically-generated hydrodynamic shock in the PWFA. The energy stability of the beams produced by that arrangement in the PWFA stage is comparable to both single-stage laser accelerators and plasma wakefield accelerators driven by conventional accelerators. Simulations support that the intrinsic insensitivity of PWFAs to driver energy fluctuations can be exploited to overcome stability limitations of state-of-the-art laser wakefield accelerators when adding a PWFA stage. Furthermore, we demonstrate the generation of electron bunches with energy spread and divergence superior to single-stage LW-FAs, resulting in bunches with dense phase space and an angular-spectral charge density beyond the initial drive beam parameters. These results unambiguously show that staged LWFA-PWFA can help to tailor the electron-beam quality for certain applications and to reduce the influence of fluctuating laser drivers on the electron-beam stability. This encourages further development of this new class of staged wakefield acceleration as a viable scheme towards compact, high-quality electron beam sources.
△ Less
Submitted 1 June, 2022;
originally announced June 2022.
-
Physics of nanocoulomb-class electron beams in laser-plasma wakefields
Authors:
J. Götzfried,
A. Döpp,
M. Gilljohann,
M. Foerster,
H. Ding,
S. Schindler,
G. Schilling,
A. Buck,
L. Veisz,
S. Karsch
Abstract:
Laser wakefield acceleration (LWFA) and its particle-driven counterpart, plasma wakefield acceleration (PWFA), are commonly treated as separate, though related branches of high-gradient plasma-based acceleration. However, novel proposed schemes are increasingly residing at the interface of both concepts where the understanding of their interplay becomes crucial. Here, we report on experiments cove…
▽ More
Laser wakefield acceleration (LWFA) and its particle-driven counterpart, plasma wakefield acceleration (PWFA), are commonly treated as separate, though related branches of high-gradient plasma-based acceleration. However, novel proposed schemes are increasingly residing at the interface of both concepts where the understanding of their interplay becomes crucial. Here, we report on experiments covering a wide range of parameters by using nanocoulomb-class quasi-monoenergetic electron beams from LWFA with a 100-TW-class laser. Based on a controlled electron injection, these beams reach record-level performance in terms of laser-to-beam energy transfer efficiency (up to 10%), spectral charge density (regularly exceeding 10 pC/MeV) and divergence (1 mrad full width at half maximum divergence). The impact of charge fluctuations on the energy spectra of electron bunches is assessed for different laser parameters, including a few-cycle laser, followed by a presentation of results on beam loading in LWFA with two electron bunches. This scenario is particularly promising to provide high-quality electron beams by using one of the bunches to either tailor the laser wakefield via beam loading or to drive its own, beam-dominated wakefield. We present experimental evidence for the latter, showing a varying acceleration of a low-energy witness beam with respect to the charge of a high-energy drive beam in a spatially separate gas target. With the increasing availability of petawatt-class lasers the access to this new regime of laser-plasma wakefield acceleration will be further facilitated, thus providing new paths towards low-emittance beam generation for future plasma-based colliders or light sources.
△ Less
Submitted 21 April, 2020;
originally announced April 2020.
-
Direct observation of plasma waves and dynamics induced by laser-accelerated electron beams
Authors:
M. F. Gilljohann,
H. Ding,
A. Döpp,
J. Goetzfried,
S. Schindler,
G. Schilling,
S. Corde,
A. Debus,
T. Heinemann,
B. Hidding,
S. M. Hooker,
A. Irman,
O. Kononenko,
T. Kurz,
A. Martinez de la Ossa,
U. Schramm,
S. Karsch
Abstract:
Plasma wakefield acceleration (PWFA) is a novel acceleration technique with promising prospects for both particle colliders and light sources. However, PWFA research has so far been limited to a few large-scale accelerator facilities world-wide. Here, we present first results on plasma wakefield generation using electron beams accelerated with a 100-TW-class Ti:Sa laser. Due to their ultrashort du…
▽ More
Plasma wakefield acceleration (PWFA) is a novel acceleration technique with promising prospects for both particle colliders and light sources. However, PWFA research has so far been limited to a few large-scale accelerator facilities world-wide. Here, we present first results on plasma wakefield generation using electron beams accelerated with a 100-TW-class Ti:Sa laser. Due to their ultrashort duration and high charge density, the laser-accelerated electron bunches are suitable to drive plasma waves at electron densities in the order of $10^{19}$ cm$^{-3}$. We capture the beam-induced plasma dynamics with femtosecond resolution using few-cycle optical probing and, in addition to the plasma wave itself, we observe a distinctive transverse ion motion in its trail. This previously unobserved phenomenon can be explained by the ponderomotive force of the plasma wave acting on the ions, resulting in a modulation of the plasma density over many picoseconds. Due to the scaling laws of plasma wakefield generation, results obtained at high plasma density using high-current laser-accelerated electron beams can be readily scaled to low-density systems. Laser-driven PWFA experiments can thus act as miniature models for their larger, conventional counterparts. Furthermore, our results pave the way towards a novel generation of laser-driven PWFA, which can potentially provide ultra-low emittance beams within a compact setup.
△ Less
Submitted 28 October, 2018;
originally announced October 2018.
-
I-BEAT: New ultrasonic method for single bunch measurement of ion energy distribution
Authors:
Daniel Haffa,
Rong Yang,
Jianhui Bin,
Sebastian Lehrack,
Florian-Emanuel Brack,
Hao Ding,
Franz Englbrecht,
Ying Gao,
Johannes Gebhard,
Max Gilljohann,
Johannes Götzfried,
Jens Hartmann,
Sebastian Herr,
Peter Hilz,
Stephan D. Kraft,
Christian Kreuzer,
Florian Kroll,
Florian H. Lindner,
Josefine Metzkes,
Tobias M. Ostermayr,
Enrico Ridente,
Thomas F. Rösch,
Gregor Schilling,
Hans-Peter Schlenvoigt,
Martin Speicher
, et al. (9 additional authors not shown)
Abstract:
The shape of a wave carries all information about the spatial and temporal structure of its source, given that the medium and its properties are known. Most modern imaging methods seek to utilize this nature of waves originating from Huygens' principle. We discuss the retrieval of the complete kinetic energy distribution from the acoustic trace that is recorded when a short ion bunch deposits its…
▽ More
The shape of a wave carries all information about the spatial and temporal structure of its source, given that the medium and its properties are known. Most modern imaging methods seek to utilize this nature of waves originating from Huygens' principle. We discuss the retrieval of the complete kinetic energy distribution from the acoustic trace that is recorded when a short ion bunch deposits its energy in water. This novel method, which we refer to as Ion-Bunch Energy Acoustic Tracing (I-BEAT), is a generalization of the ionoacoustic approach. Featuring compactness, simple operation, indestructibility and high dynamic ranges in energy and intensity, I-BEAT is a promising approach to meet the needs of petawatt-class laser-based ion accelerators. With its capability of completely monitoring a single, focused proton bunch with prompt readout it, is expected to have particular impact for experiments and applications using ultrashort ion bunches in high flux regimes. We demonstrate its functionality using it with two laser-driven ion sources for quantitative determination of the kinetic energy distribution of single, focused proton bunches.
△ Less
Submitted 7 September, 2018;
originally announced September 2018.