-
Ultra-stable 3D-printed precision voltage divider for calibrations and experiments
Authors:
Stephan Passon,
Kristian König,
Florian Schilling,
Bernhard Maaß,
Johann Meisner,
Wilfried Nörtershäuser
Abstract:
This paper presents the concept of an ultra-stable, thermally independent precision voltage divider tailored for direct current (DC) voltages up to 60 kV. Key features of this voltage divider include minimal voltage dependence, excellent stability, and resistance to external temperature variations. The innovative approach involves its fabrication using 3D printing technology, allowing easy replica…
▽ More
This paper presents the concept of an ultra-stable, thermally independent precision voltage divider tailored for direct current (DC) voltages up to 60 kV. Key features of this voltage divider include minimal voltage dependence, excellent stability, and resistance to external temperature variations. The innovative approach involves its fabrication using 3D printing technology, allowing easy replication by project partners. This precision voltage divider leverages commercially available precision resistors, drawing upon successful outcomes from the FutureEnergy 19ENG02 and HVDC ENG07 Projects. In these experiments, which involve ion acceleration and laser probing of electronic transitions, voltage dividers are integrated into setups such as COALA (TU Darmstadt), BECOLA (Michigan State University), COLLAPS (CERN/ISOLDE), and ATLANTIS (Argonne National Laboratory). Monitoring the applied acceleration potential, these dividers allow one to consider and counteract long-term drifts and thereby improving measurement accuracy.
△ Less
Submitted 9 July, 2024;
originally announced July 2024.
-
Current Methods for Hyperpolarized [1-13C]pyruvate MRI Human Studies
Authors:
Peder EZ Larson,
Jenna ML Bernard,
James A Bankson,
Nikolaj Bøgh,
Robert A Bok,
Albert P. Chen,
Charles H Cunningham,
Jeremy Gordon,
Jan-Bernd Hövener,
Christoffer Laustsen,
Dirk Mayer,
Mary A McLean,
Franz Schilling,
James Slater,
Jean-Luc Vanderheyden,
Cornelius von Morze,
Daniel B Vigneron,
Duan Xu,
the HP 13C MRI Consensus Group
Abstract:
MRI with hyperpolarized (HP) 13C agents, also known as HP 13C MRI, can measure processes such as localized metabolism that is altered in numerous cancers, liver, heart, kidney diseases, and more. It has been translated into human studies during the past 10 years, with recent rapid growth in studies largely based on increasing availability of hyperpolarized agent preparation methods suitable for us…
▽ More
MRI with hyperpolarized (HP) 13C agents, also known as HP 13C MRI, can measure processes such as localized metabolism that is altered in numerous cancers, liver, heart, kidney diseases, and more. It has been translated into human studies during the past 10 years, with recent rapid growth in studies largely based on increasing availability of hyperpolarized agent preparation methods suitable for use in humans. This paper aims to capture the current successful practices for HP MRI human studies with [1-13C]pyruvate - by far the most commonly used agent, which sits at a key metabolic junction in glycolysis. The paper is divided into four major topic areas: (1) HP 13C-pyruvate preparation, (2) MRI system setup and calibrations, (3) data acquisition and image reconstruction, and (4) data analysis and quantification. In each area, we identified the key components for a successful study, summarized both published studies and current practices, and discuss evidence gaps, strengths, and limitations. This paper is the output of the HP 13C MRI Consensus Group as well as the ISMRM Hyperpolarized Media MR and Hyperpolarized Methods & Equipment study groups. It further aims to provide a comprehensive reference for future consensus building as the field continues to advance human studies with this metabolic imaging modality.
△ Less
Submitted 22 November, 2023; v1 submitted 7 September, 2023;
originally announced September 2023.
-
Metrology for Inductive Charging of Electric Vehicles (MICEV)
Authors:
M. Zucca,
O. Bottauscio,
S. Harmon,
R. Guilizzoni,
F. Schilling,
M. Schmidt,
P. Ankarson,
T. Bergsten,
K. Tammi,
P. Sainio,
J. B. Romero,
E. L. Puyal,
L. Pichon,
F. Freschi,
V. Cirimele,
P. Bauer,
J. Dong,
A. Maffucci,
S. Ventre,
N. Femia,
G. Di Capua,
N. Kuster,
I. Liorni
Abstract:
The European Union funded project MICEV aims at improving the traceability of electrical and magnetic measurement at charging stations and to better assess the safety of this technology with respect to human exposure. The paper describes some limits of the instrumentation used for electrical measurements in the charging stations, and briefly presents two new calibration facilities for magnetic fie…
▽ More
The European Union funded project MICEV aims at improving the traceability of electrical and magnetic measurement at charging stations and to better assess the safety of this technology with respect to human exposure. The paper describes some limits of the instrumentation used for electrical measurements in the charging stations, and briefly presents two new calibration facilities for magnetic field meters and electric power meters. Modeling approaches for the efficiency and human exposure assessment are proposed. In the latter case, electromagnetic computational codes have been combined with dosimetric computational codes making use of highly detailed human anatomical phantoms in order to establish human exposure modeling real charging stations. Detailed results are presented for light vehicles where, according to our calculations, the concern towards human exposure is limited. Currently, the project has reached half way point (about 18 months) and will end in August 2020.
△ Less
Submitted 29 August, 2019;
originally announced August 2019.
-
The precise determination of mass through the oscillations of a very high-Q superconductor oscillating system
Authors:
Osvaldo F. Schilling
Abstract:
The present paper is based upon the fact that if an object is part of a highly stable oscillating system, it is possible to obtain an extremely precise measure for its mass in terms of the energy trapped in this resonance. The subject is timely since there is great interest in Metrology on the establishment of a new electronic standard for the kilogram. Our contribution to such effort includes bot…
▽ More
The present paper is based upon the fact that if an object is part of a highly stable oscillating system, it is possible to obtain an extremely precise measure for its mass in terms of the energy trapped in this resonance. The subject is timely since there is great interest in Metrology on the establishment of a new electronic standard for the kilogram. Our contribution to such effort includes both the proposal of an alternative definition for mass in terms of energy, as well as the description of a realistic experimental system in which this definition might actually be applied. The setup consists of an oscillating type-II superconducting loop (the SEO system) subjected to the gravity and magnetic fields. The system is shown to be able to reach a dynamic equilibrium by trap** energy up to the point it levitates against the surrounding magnetic and gravitational fields, behaving as an extremely high-Q spring-load system. The proposed energy-mass equation applied to the electromechanical oscillating system eventually produces a new experimental relation between mass and standardized constants.
△ Less
Submitted 29 August, 2013;
originally announced September 2013.
-
A Comparison between two methods for the measurement of the Planck constant h, the watt balance and the superconductor electromechanical oscillator methods
Authors:
Osvaldo F. Schilling
Abstract:
The purpose of this note is to make a brief analysis of the physical principles upon which two methods for relating the mass of an object to fundamental physical constants are based. The two methods are, namely, the watt balance method, and a still untested experimental technique based upon a superconductor electromechanical oscillator. We show that both these methods are governed by similar equ…
▽ More
The purpose of this note is to make a brief analysis of the physical principles upon which two methods for relating the mass of an object to fundamental physical constants are based. The two methods are, namely, the watt balance method, and a still untested experimental technique based upon a superconductor electromechanical oscillator. We show that both these methods are governed by similar equations.
△ Less
Submitted 13 August, 2009;
originally announced August 2009.
-
Application of Conformal Map** to the determination of Magnetic Moment Distributions in typical Antidot Film Nanostructures
Authors:
Osvaldo F. Schilling
Abstract:
There has been an increasing technological interest on magnetic thin films containing antidot arrays of hexagonal or square symmetry. Part of this interest is related to the possibility of domain formation and pinning at the antidots boundaries. In this paper, we develop a method for the calculation of the magnetic moment distribution for such arrays which concentrates on the immediate vicinity…
▽ More
There has been an increasing technological interest on magnetic thin films containing antidot arrays of hexagonal or square symmetry. Part of this interest is related to the possibility of domain formation and pinning at the antidots boundaries. In this paper, we develop a method for the calculation of the magnetic moment distribution for such arrays which concentrates on the immediate vicinity of each antidot. For each antidot distribution (square or hexagonal) a suitable system of coordinates is defined to exploit the shape of the unit-cells of the overall nanostructure. The Landau-Lifshitz-Gilbert-Brown equations that govern the distribution of moments are rewritten in terms of these coordinates. The equilibrium moments orientation is calculated for each position in a Cartesian grid defined for these new coordinate systems, and then a conformal transformation is applied to insert the moment vectors into the actual unit-cell. The resulting vector maps display quite clearly regions of different moment orientation around the antidots, which can be associated with nanoscale domains. These results are similar to the ones obtained by other authors[1-4] using the NIST oommf method.
△ Less
Submitted 2 December, 2008;
originally announced December 2008.
-
Track Based Alignment in CMS
Authors:
Frank-Peter Schilling
Abstract:
The strategy for track based alignment of the CMS tracking and muon detectors is presented. After an overview over the used data samples, the general alignment strategy is presented, with a focus of the procedures envisaged at the start of data taking in 2008. The three currently used alignment algorithms are discussed and first results on their application to the CMS tracker are presented, as w…
▽ More
The strategy for track based alignment of the CMS tracking and muon detectors is presented. After an overview over the used data samples, the general alignment strategy is presented, with a focus of the procedures envisaged at the start of data taking in 2008. The three currently used alignment algorithms are discussed and first results on their application to the CMS tracker are presented, as well as studies on the alignment of the Muon detector with tracks.
△ Less
Submitted 21 September, 2007;
originally announced September 2007.
-
The design of a very high-Q superconductor electromechanical clock
Authors:
Osvaldo F. Schilling
Abstract:
We discuss theoretically the properties of an electromechanical oscillator whose operation is based upon the cyclic, quasi-conservative conversion between gravitational potential, kinetic, and magnetic energies. The system consists of a strong-pinning type-II superconductor square loop subjected to a constant external force and to magnetic fields. The loop oscillates in the upright position at a f…
▽ More
We discuss theoretically the properties of an electromechanical oscillator whose operation is based upon the cyclic, quasi-conservative conversion between gravitational potential, kinetic, and magnetic energies. The system consists of a strong-pinning type-II superconductor square loop subjected to a constant external force and to magnetic fields. The loop oscillates in the upright position at a frequency that can be tuned in the range 10-1000 Hz, and has induced in it a rectified electrical current. The emphasis of this paper is on the evaluation of the major remaining source of losses in the oscillations. We argue that such losses should be associated with the viscous vibration of pinned flux lines in the superconductor Nb-Ti wire, provided the oscillator is kept close to zero Kelvin, under high-vacuum, and the magnetic field is sufficiently uniform. We discuss how other different sources of loss would become negligible for such operational conditions, so that a very high quality factor Q exceeding 10^(10) might in principle be reached by the oscillator. The prospective utilization of such oscillator as a low-frequency high-Q clock is analyzed.Since publication the ideas in this paper have been explored both by the author and elsewhere, in applications covering Metrology, quantum systems, and gravimetry.
△ Less
Submitted 23 July, 2018; v1 submitted 19 May, 2007;
originally announced May 2007.
-
Track Reconstruction and Alignment with the CMS Silicon Tracker
Authors:
F. -P. Schilling
Abstract:
This report presents recent results on track reconstruction and alignment with the silicon tracker of the CMS experiment at the LHC, obtained with a full detector simulation. After an overview of the layout of the tracker and its material budget, the baseline algorithm for track reconstruction is discussed. The performance of the track reconstruction and its dependence on misalignment is shown.…
▽ More
This report presents recent results on track reconstruction and alignment with the silicon tracker of the CMS experiment at the LHC, obtained with a full detector simulation. After an overview of the layout of the tracker and its material budget, the baseline algorithm for track reconstruction is discussed. The performance of the track reconstruction and its dependence on misalignment is shown. The concept for alignment of the CMS tracker, using a laser alignment system as well as three different track-based alignment algorithms, is presented.
△ Less
Submitted 1 October, 2006;
originally announced October 2006.
-
The Ideal Electromechanical Oscillator System
Authors:
Osvaldo F. Schilling
Abstract:
Oscillators and rotators are among the most important physical systems. For centuries the only known rotating systems that actually reached the limits of the ideal situation of undamped periodical motion were the planets in their orbits. Physics had to develop quantum mechanics to discover new systems that actually behaved like ideal, undamped, oscillators or rotators. However, all examples of t…
▽ More
Oscillators and rotators are among the most important physical systems. For centuries the only known rotating systems that actually reached the limits of the ideal situation of undamped periodical motion were the planets in their orbits. Physics had to develop quantum mechanics to discover new systems that actually behaved like ideal, undamped, oscillators or rotators. However, all examples of this latter systems occur in atomic or molecular scale. The objective of the present letter is to show how the limit of ideal oscillating motion can be challenged by a man-made system. We demonstrate how a simple model electromechanical system consisting of a superconducting coil and a magnet can be made to display both mechanical and electrical undamped oscillations for certain experimental conditions. The effect might readily be attainable with the existing materials technologies and we discuss the conditions to circumvent energy losses. The result is a lossless system that might generate hundreds of Ampere of rectified electrical current by means of the periodical conversion between gravitational potential, kinetic, and magnetic energies.
△ Less
Submitted 25 October, 2003;
originally announced October 2003.
-
Electric energy by direct conversion from gravitational energy: a gift from superconductivity
Authors:
Osvaldo F. Schilling
Abstract:
We theoretically demonstrate that electromagnetic energy can be obtained by direct, lossless, conversion from gravitational and kinetic energies. For this purpose we discuss the properties of an electromechanical system which consists of a superconducting coil submitted to a constant external force and to magnetic fields. The coil oscillates and has induced in it a rectified electrical current w…
▽ More
We theoretically demonstrate that electromagnetic energy can be obtained by direct, lossless, conversion from gravitational and kinetic energies. For this purpose we discuss the properties of an electromechanical system which consists of a superconducting coil submitted to a constant external force and to magnetic fields. The coil oscillates and has induced in it a rectified electrical current whose magnitude may reach hundreds of Ampere. There is no need for an external electrical power source for the system to start out and it can be kept working continuously if linked to large capacitors. We extensively discuss the issue of energy dissipation in superconductors and show that the losses for such a system can be made extremely small for certain operational conditions, so that by reaching and kee** resonance the system main application should be in magnetic energy storage and transmission.
△ Less
Submitted 1 September, 2003;
originally announced September 2003.