arXiv:0810.0445 [pdf, ps, other]
New gas mixtures suitable for rare event detection using a Micromegas-TPC detector
Abstract: The aim of the presented work was to develop further techniques based on a Micromegas-TPC, in order to reach a high gas gain with good energy resolution, and to search for gas mixtures suitable for rare event detection. This paper focuses on xenon, which is convenient for the search of neutrinoless double beta decay in 136 Xe. Conversely, a small admixture of xenon to CF 4 can reduce attachment… ▽ More
Submitted 29 December, 2008; v1 submitted 2 October, 2008; originally announced October 2008.
Comments: 14 pages, 8 figures, article, revised version with improved figures, text modifications, accepted for publication by JINST
Journal ref: JINST 4:P01001,2009
-
arXiv:0709.4524 [pdf, ps, other]
Systematic study of trace radioactive impurities in candidate construction materials for EXO-200
Abstract: The Enriched Xenon Observatory (EXO) will search for double beta decays of 136Xe. We report the results of a systematic study of trace concentrations of radioactive impurities in a wide range of raw materials and finished parts considered for use in the construction of EXO-200, the first stage of the EXO experimental program. Analysis techniques employed, and described here, include direct gamma… ▽ More
Submitted 4 August, 2008; v1 submitted 28 September, 2007; originally announced September 2007.
Comments: 32 pages, 6 figures. Expanded introduction, added missing table entry. Accepted for publication in Nucl. Instrum. Meth. A
Journal ref: Nucl.Instrum.Meth.A591:490-509,2008
-
A linear RFQ ion trap for the Enriched Xenon Observatory
Abstract: The design, construction, and performance of a linear radio-frequency ion trap (RFQ) intended for use in the Enriched Xenon Observatory (EXO) are described. EXO aims to detect the neutrinoless double-beta decay of $^{136}$Xe to $^{136}$Ba. To suppress possible backgrounds EXO will complement the measurement of decay energy and, to some extent, topology of candidate events in a Xe filled detector… ▽ More
Submitted 12 April, 2007; originally announced April 2007.
Comments: 18 pages, pdflatex, submitted to NIM A
Journal ref: Nucl.Instrum.Meth.A578:399-408,2007
-
Observation of single collisionally cooled trapped ions in a buffer gas
Abstract: Individual Ba ions are trapped in a gas-filled linear ion trap and observed with a high signal-to-noise ratio by resonance fluorescence. Single-ion storage times of ~5 min (~1 min) are achieved using He (Ar) as a buffer gas at pressures in the range 8e-5 - 4e-3 torr. Trap dynamics in buffer gases are experimentally studied in the simple case of single ions. In particular, the cooling effects of… ▽ More
Submitted 5 July, 2007; v1 submitted 14 February, 2007; originally announced February 2007.
Comments: 5 pages, 4 figures, accepted for publication in Phys. Rev. A. Minor text and figure changes
-
A liquid xenon ionization chamber in an all-fluoropolymer vessel
Abstract: A novel technique has been developed to build vessels for liquid xenon ionization detectors entirely out of ultra-clean fluoropolymer. We describe the advantages in terms of low radioactivity contamination, provide some details of the construction techniques, and show the energy resolution achieved with a prototype all-fluoropolymer ionization detector.
Submitted 19 November, 2006; originally announced November 2006.
Comments: 12 pages, 9 figures
Journal ref: Nucl.Instrum.Meth.A578:409-420,2007