A probabilistic deep learning model of inter-fraction anatomical variations in radiotherapy
Authors:
Oscar Pastor-Serrano,
Steven Habraken,
Mischa Hoogeman,
Danny Lathouwers,
Dennis Schaart,
Yusuke Nomura,
Lei Xing,
Zoltán Perkó
Abstract:
In radiotherapy, the internal movement of organs between treatment sessions causes errors in the final radiation dose delivery. Motion models can be used to simulate motion patterns and assess anatomical robustness before delivery. Traditionally, such models are based on principal component analysis (PCA) and are either patient-specific (requiring several scans per patient) or population-based, ap…
▽ More
In radiotherapy, the internal movement of organs between treatment sessions causes errors in the final radiation dose delivery. Motion models can be used to simulate motion patterns and assess anatomical robustness before delivery. Traditionally, such models are based on principal component analysis (PCA) and are either patient-specific (requiring several scans per patient) or population-based, applying the same deformations to all patients. We present a hybrid approach which, based on population data, allows to predict patient-specific inter-fraction variations for an individual patient. We propose a deep learning probabilistic framework that generates deformation vector fields (DVFs) war** a patient's planning computed tomography (CT) into possible patient-specific anatomies. This daily anatomy model (DAM) uses few random variables capturing groups of correlated movements. Given a new planning CT, DAM estimates the joint distribution over the variables, with each sample from the distribution corresponding to a different deformation. We train our model using dataset of 312 CT pairs from 38 prostate cancer patients. For 2 additional patients (22 CTs), we compute the contour overlap between real and generated images, and compare the sampled and ground truth distributions of volume and center of mass changes. With a DICE score of 0.86 and a distance between prostate contours of 1.09 mm, DAM matches and improves upon PCA-based models. The distribution overlap further indicates that DAM's sampled movements match the range and frequency of clinically observed daily changes on repeat CTs. Conditioned only on a planning CT and contours of a new patient without any pre-processing, DAM can accurately predict CTs seen during following treatment sessions, which can be used for anatomically robust treatment planning and robustness evaluation against inter-fraction anatomical changes.
△ Less
Submitted 20 September, 2022;
originally announced September 2022.
-
A platform for high performance photon correlation measurements
Authors:
Iman Esmaeil Zadeh,
Johannes W. N. Los,
Ronan B. M. Gourgues,
** Chang,
Ali W. Elshaari,
Julien Zichi,
Yuri J. van Staaden,
Jeroen Swens,
Nima Kalhor,
Antonio Guardiani,
Yun Meng,
Kai Zou,
Sergiy Dobrovolskiy,
Andreas W. Fognini,
Dennis R. Schaart,
Dan Dalacu,
Philip J. Poole,
Michael E. Reimer,
Xiaolong Hu,
Silvania F. Pereira,
Val Zwiller,
Sander N. Dorenbos
Abstract:
A broad range of scientific and industrial disciplines require precise optical measurements at very low light levels. Single-photon detectors combining high efficiency and high time resolution are pivotal in such experiments. By using relatively thick films of NbTiN (8-11\,nm) and improving the pattern fidelity of the nano-structure of the superconducting nanowire single-photon detectors (SNSPD),…
▽ More
A broad range of scientific and industrial disciplines require precise optical measurements at very low light levels. Single-photon detectors combining high efficiency and high time resolution are pivotal in such experiments. By using relatively thick films of NbTiN (8-11\,nm) and improving the pattern fidelity of the nano-structure of the superconducting nanowire single-photon detectors (SNSPD), we fabricated devices demonstrating superior performance over all previously reported detectors in the combination of efficiency and time resolution. Our findings prove that small variations in the nanowire width, in the order of a few nanometers, can lead to a significant penalty on their temporal response. Addressing these issues, we consistently achieved high time resolution (best device 7.7\,ps, other devices $\sim$10-16\,ps) simultaneously with high system detection efficiencies ($80-90\%$) in the wavelength range of 780-1000\,nm, as well as in the telecom bands (1310-1550\,nm). The use of thicker films allowed us to fabricate large-area multi-pixel devices with homogeneous pixel performance. We first fabricated and characterized a $100\times100\, μm^2$ 16-pixel detector and showed there was little variation among individual pixels. Additionally, to showcase the power of our platform, we fabricated and characterized 4-pixel multimode fiber-coupled detectors and carried out photon correlation experiments on a nanowire quantum dot resulting in $g^2(0)$ values lower than 0.04. The multi-pixel detectors alleviate the need for beamsplitters and can be used for higher order correlations with promising prospects not only in the field of quantum optics, but also in bio-imaging applications, such as fluorescence microscopy and positron emission tomography.
△ Less
Submitted 22 March, 2020;
originally announced March 2020.
-
A High Count-Rate and Depth-of-Interaction Resolving Single Layered One-Side Readout Pixelated Scintillator Crystal Array for PET Applications
Authors:
J. M. C. Brown,
S. E. Brunner,
D. R. Schaart
Abstract:
Organ-specific, targeted Field-of-View (FoV) Positron Emission Tomography (PET)/Magnetic Resonance Imaging (MRI) inserts are viable solutions for a number of imaging tasks where whole-body PET/MRI systems lack the necessary sensitivity and resolution. To meet the required PET detector performance of these systems, high count-rates and effective spatial resolutions on the order of a few mm, a novel…
▽ More
Organ-specific, targeted Field-of-View (FoV) Positron Emission Tomography (PET)/Magnetic Resonance Imaging (MRI) inserts are viable solutions for a number of imaging tasks where whole-body PET/MRI systems lack the necessary sensitivity and resolution. To meet the required PET detector performance of these systems, high count-rates and effective spatial resolutions on the order of a few mm, a novel two-axis patterned reflector foil pixelated scintillator crystal array design is developed and its proof-of-concept illustrated in-silico with the Monte Carlo radiation transport modelling toolkit Geant4. It is shown that the crystal surface roughness and phased open reflector cross-section patterns could be optimised to maximise either the PET radiation detector's effective spatial resolution, or count rate before event pile up. In addition, it was illustrated that these two parameters had minimal impact on the energy and time resolution of the proposed PET radiation detector design. Finally, it is shown that a PET radiation detector with balance performance could be constructed using ground crystals and phased open reflector cross-section pattern corresponding to the middle of the tested range.
△ Less
Submitted 18 September, 2019; v1 submitted 27 May, 2019;
originally announced May 2019.
-
GATE : a simulation toolkit for PET and SPECT
Authors:
S. Jan,
G. Santin,
D. Strul,
S. Staelens,
K. Assie,
D. Autret,
S. Avner,
R. Barbier,
M. Bardies,
P. M. Bloomfield,
D. Brasse,
V. Breton,
P. Bruyndonckx,
I. Buvat,
A. F. Chatziioannou,
Y. Choi,
Y. H. Chung,
C. Comtat,
D. Donnarieix,
L. Ferrer,
S. J. Glick,
C. J. Groiselle,
D. Guez,
P. -F. Honore,
S. Kerhoas-Cavata
, et al. (28 additional authors not shown)
Abstract:
Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols, and the development or assessment of image reconstruction algorithms and correction techniques. GATE, the Geant4 Application for Tomographic Emission, encapsulates the Geant4 libraries to achieve a modular, versatile, scripted…
▽ More
Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols, and the development or assessment of image reconstruction algorithms and correction techniques. GATE, the Geant4 Application for Tomographic Emission, encapsulates the Geant4 libraries to achieve a modular, versatile, scripted simulation toolkit adapted to the field of nuclear medicine. In particular, GATE allows the description of time-dependent phenomena such as source or detector movement, and source decay kinetics. This feature makes it possible to simulate time curves under realistic acquisition conditions and to test dynamic reconstruction algorithms. A public release of GATE licensed under the GNU Lesser General Public License can be downloaded at the address http://www-lphe.epfl.ch/GATE/.
△ Less
Submitted 24 August, 2004;
originally announced August 2004.