-
On the origin of the type-III radiation observed near the Sun
Authors:
Forrest Mozer,
Oleksiy Agapitos,
Stuart Bale,
Keith Goetz,
Vladimir Krasnoselskikh,
Marc Pulupa,
Konrad Sauer,
Andrii Voshchepinets
Abstract:
$\textit{AIMS.}$ (1) To use Parker Solar Probe (PSP) data to test the accepted theory that type-III radiation is produced by counter-streaming Langmuir waves that coalesce to produce the electromagnetic wave at twice the Langmuir frequency. (2) To use the new data obtained from the PSP to improve or modify the model of type-III wave generation.
$\textit{METHODS.}…
▽ More
$\textit{AIMS.}$ (1) To use Parker Solar Probe (PSP) data to test the accepted theory that type-III radiation is produced by counter-streaming Langmuir waves that coalesce to produce the electromagnetic wave at twice the Langmuir frequency. (2) To use the new data obtained from the PSP to improve or modify the model of type-III wave generation.
$\textit{METHODS.}$ To obtain new properties of the Langmuir wave and its harmonics, their phase velocities and density fluctuations were measured. If the harmonic wave was electromagnetic, as in the accepted theory, these quantities would not be measurable. However, in an electrostatic wave, they would be measurable by the PSP instruments.
$\textit{RESULTS.}$ The Langmuir wave and its harmonics at frequencies of $nω_p$, where $ω_p = 2π\times125$ kHz is the Langmuir frequency and $n \in \{ 2, 3, 4, 5, 6, 7\}$, were measured in an active type-III event. The lowest harmonics contained density fluctuations, so they were electrostatic waves and not type-III emissions. This result was bolstered by measuring their very slow phase velocities ($< 20,000$ km/sec) which are not those of a type-III wave. Thus, the harmonic waves were not a result of the three-wave interaction (as required by the accepted theory) but they were electrostatic antenna waves produced by radiation of the Langmuir wave. As at least the first harmonic wave evolved through density irregularities, its wave number decreased and it became the electromagnetic wave that was the type-III radiation. It is also found that there is no evidence for or against the conventional model for generation of the type-III emissions.
△ Less
Submitted 14 June, 2024; v1 submitted 9 March, 2024;
originally announced March 2024.
-
Large-scale, Multi-pass, Two-chamber RF Atomic Magnetometer
Authors:
D. J. Heilman,
K. L. Sauer,
D. W. Prescott,
C. Z. Motamedi,
N. Dural,
M. V. Romalis,
T. W. Kornack
Abstract:
We describe one of the largest radio-frequency RF atomic magnetometers presently operating. A total atomic volume of 128 $\mathrm{cm^3}$, with correspondingly large number of $^{87}$Rb atoms, can reduce atom noise. A total of 44 passes of the probe beam reduces photon-shot noise. The atomic vapor is divided between two chambers allowing for pum** of the cells individually; doing so with opposite…
▽ More
We describe one of the largest radio-frequency RF atomic magnetometers presently operating. A total atomic volume of 128 $\mathrm{cm^3}$, with correspondingly large number of $^{87}$Rb atoms, can reduce atom noise. A total of 44 passes of the probe beam reduces photon-shot noise. The atomic vapor is divided between two chambers allowing for pum** of the cells individually; doing so with opposite-helicity light enables use as an intrinsic gradiometer. In this configuration, common-mode noise sources including light-shift noise can be reduced. Magnetic tuning fields can also be applied to the chambers individually, allowing simultaneous measurement of two frequencies. An application of this is in the search for contraband materials using Nuclear Quadrupole Resonance (NQR), for which simultaneous measurement can significantly reduce search times. We demonstrate dual-frequency measurement on an effective range of 423-531 kHz, corresponding to the NQR frequencies of ammonium nitrate NH$_4$NO$_3$ at the lowest value and potassium chlorate KClO$_3$ at the highest. We explore fundamental, as well as instrumental, noise contributions to the sensitivity in this system.
△ Less
Submitted 15 December, 2023;
originally announced December 2023.
-
Statistically Adaptive Filtering for Low Signal Correction in X-ray Computed Tomography
Authors:
Obaidullah Rahman,
Ken D. Sauer,
Charles A. Bouman,
Roman Melnyk,
Brian Nett
Abstract:
Low x-ray dose is desirable in x-ray computed tomographic (CT) imaging due to health concerns. But low dose comes with a cost of low signal artifacts such as streaks and low frequency bias in the reconstruction. As a result, low signal correction is needed to help reduce artifacts while retaining relevant anatomical structures.
Low signal can be encountered in cases where sufficient number of ph…
▽ More
Low x-ray dose is desirable in x-ray computed tomographic (CT) imaging due to health concerns. But low dose comes with a cost of low signal artifacts such as streaks and low frequency bias in the reconstruction. As a result, low signal correction is needed to help reduce artifacts while retaining relevant anatomical structures.
Low signal can be encountered in cases where sufficient number of photons do not reach the detector to have confidence in the recorded data. % NOTE: SNR is ratio of powers, not std. dev. X-ray photons, assumed to have Poisson distribution, have signal to noise ratio proportional to the dose, with poorer SNR in low signal areas. Electronic noise added by the data acquisition system further reduces the signal quality.
In this paper we will demonstrate a technique to combat low signal artifacts through adaptive filtration. It entails statistics-based filtering on the uncorrected data, correcting the lower signal areas more aggressively than the high signal ones. We look at local averages to decide how aggressive the filtering should be, and local standard deviation to decide how much detail preservation to apply. Implementation consists of a pre-correction step i.e. local linear minimum mean-squared error correction, followed by a variance stabilizing transform, and finally adaptive bilateral filtering. The coefficients of the bilateral filter are computed using local statistics. Results show that improvements were made in terms of low frequency bias, streaks, local average and standard deviation, modulation transfer function and noise power spectrum.
△ Less
Submitted 23 September, 2023;
originally announced September 2023.
-
Magnetic Jones Vector Detection with RF Atomic Magnetometers
Authors:
Cicely Motamedi,
Karen Sauer
Abstract:
We show, theoretically and experimentally, how the absolute orientation and polarization state of radio-frequency (RF) magnetic fields in a transverse 2D plane can be uniquely determined using two optically pumped atomic magnetometers. In addition, the output signals from these quantum sensors can be readily expressed as a magnetic Jones vector. This composite device can complement electric field…
▽ More
We show, theoretically and experimentally, how the absolute orientation and polarization state of radio-frequency (RF) magnetic fields in a transverse 2D plane can be uniquely determined using two optically pumped atomic magnetometers. In addition, the output signals from these quantum sensors can be readily expressed as a magnetic Jones vector. This composite device can complement electric field detection in finding RF directions, or it can be used in applications where the electric field is negligible. The latter is found in a myriad of applications where the source can be modeled as radiating magnetic dipoles in the near-field limit. This new tool could be used to characterize a material's response to RF excitation or to distinguish signal from noise.
△ Less
Submitted 6 June, 2023; v1 submitted 30 March, 2023;
originally announced March 2023.
-
Density Enhancement Streams in The Solar Wind
Authors:
F. S. Mozer,
O. Agapitov,
S. D. Bale,
R. Livi,
O. Romeo,
K. Sauer,
I. Y. Vasko,
J. Verniero
Abstract:
This letter describes a new phenomenon on the Parker Solar Probe of recurring plasma density enhancements that have $Δ$n/n ~10% and that occur at a repetition rate of ~5 Hz. They were observed sporadically for about five hours between 14 and 15 solar radii on Parker Solar Probe orbit 12 and they were also seen in the same radial range on both the inbound and outbound orbits 11. Their apparently st…
▽ More
This letter describes a new phenomenon on the Parker Solar Probe of recurring plasma density enhancements that have $Δ$n/n ~10% and that occur at a repetition rate of ~5 Hz. They were observed sporadically for about five hours between 14 and 15 solar radii on Parker Solar Probe orbit 12 and they were also seen in the same radial range on both the inbound and outbound orbits 11. Their apparently steady-state existence suggests that their pressure gradient was balanced by the electric field. The EX electric field component produced from this requirement is in good agreement with that measured. This provides strong evidence for the measurement accuracy of the density fluctuations and the X- and Y-components of the electric field (the Z-component was not measured). The electrostatic density waves were accompanied by an electromagnetic low frequency wave which occurred with the electrostatic harmonics. The amplitudes of these electrostatic and electromagnetic waves at $\ge$ 1 Hz were greater than the amplitude of the Alfvenic turbulence in their vicinity so they can be important for the heating, scattering, and acceleration of the plasma. The existence of this pair of waves is consistent with the observed plasma distributions and is explained by a magneto-acoustic wave theory that produces a low frequency electromagnetic wave and electrostatic harmonics.
△ Less
Submitted 29 July, 2023; v1 submitted 17 February, 2023;
originally announced February 2023.
-
Model Based Iterative Reconstruction With Spatially Adaptive Sinogram Weights for Wide-Cone Cardiac CT
Authors:
Amirkoushyar Ziabari,
Dong Hye Ye,
Lin Fu,
Somesh Srivastava,
Ken D. Sauer,
Jean-Baptist Thibault,
Charles A. Bouman
Abstract:
With the recent introduction of CT scanners with large cone angles, wide coverage detectors now provide a desirable scanning platform for cardiac CT that allows whole heart imaging in a single rotation. On these scanners, while half-scan data is strictly sufficient to produce images with the best temporal resolution, acquiring a full 360 degree rotation worth of data is beneficial for wide-cone im…
▽ More
With the recent introduction of CT scanners with large cone angles, wide coverage detectors now provide a desirable scanning platform for cardiac CT that allows whole heart imaging in a single rotation. On these scanners, while half-scan data is strictly sufficient to produce images with the best temporal resolution, acquiring a full 360 degree rotation worth of data is beneficial for wide-cone image reconstruction at negligible additional radiation dose. Applying Model-Based Iterative Reconstruction (MBIR) algorithm to the heart has shown to yield significant enhancement in image quality for cardiac CT. But imaging the heart in large cone angle geometry leads to apparently conflicting data usage considerations. On the one hand, in addition to using the fastest available scanner rotation speed, a minimal complete data set of 180 degrees plus the fan angle is typically used to minimize both cardiac and respiratory motion. On the other hand, a full 360 degree acquisition helps better handle the challenges of missing frequencies and incomplete projections associated with wide-cone half-scan data acquisition. In this paper, we develop a Spatially Adaptive sinogram Weights MBIR algorithm (SAW-MBIR) that is designed to achieve the benefits of both half and full-scan reconstructions in order to maximize temporal resolution over the heart region while providing stable results over the whole volume covered with the wide-area detector. Spatially-adaptive sinogram weights applied to each projection measurement in SAW-MBIR are designed to selectively perform backprojection from the full and half-scan portion of the sinogram based on both projection angle and reconstructed voxel location. We demonstrate with experimental results of SAW-MBIR applied to whole-heart cardiac CT clinical data that overall temporal resolution matches half-scan while full volume image quality is on par with full-scan MBIR.
△ Less
Submitted 20 December, 2018;
originally announced December 2018.
-
A Gaussian Mixture MRF for Model-Based Iterative Reconstruction with Applications to Low-Dose X-ray CT
Authors:
Ruoqiao Zhang,
Dong Hye Ye,
Debashish Pal,
Jean-Baptiste Thibault,
Ken D. Sauer,
Charles A. Bouman
Abstract:
Markov random fields (MRFs) have been widely used as prior models in various inverse problems such as tomographic reconstruction. While MRFs provide a simple and often effective way to model the spatial dependencies in images, they suffer from the fact that parameter estimation is difficult. In practice, this means that MRFs typically have very simple structure that cannot completely capture the s…
▽ More
Markov random fields (MRFs) have been widely used as prior models in various inverse problems such as tomographic reconstruction. While MRFs provide a simple and often effective way to model the spatial dependencies in images, they suffer from the fact that parameter estimation is difficult. In practice, this means that MRFs typically have very simple structure that cannot completely capture the subtle characteristics of complex images.
In this paper, we present a novel Gaussian mixture Markov random field model (GM-MRF) that can be used as a very expressive prior model for inverse problems such as denoising and reconstruction. The GM-MRF forms a global image model by merging together individual Gaussian-mixture models (GMMs) for image patches. In addition, we present a novel analytical framework for computing MAP estimates using the GM-MRF prior model through the construction of surrogate functions that result in a sequence of quadratic optimizations. We also introduce a simple but effective method to adjust the GM-MRF so as to control the sharpness in low- and high-contrast regions of the reconstruction separately. We demonstrate the value of the model with experiments including image denoising and low-dose CT reconstruction.
△ Less
Submitted 13 June, 2016; v1 submitted 12 May, 2016;
originally announced May 2016.
-
Spin Dam** in an RF Atomic Magnetometer
Authors:
Orang Alem,
Karen L. Sauer,
Mike V. Romalis
Abstract:
Under negative feedback, the quality factor Q of a radio-frequency magnetometer can be decreased by more than two orders of magnitude, so that any initial perturbation of the polarized spin system can be rapidly damped, preparing the magnetometer for detection of the desired signal. We find that noise is also suppressed under such spin-dam**, with a characteristic spectral response corresponding…
▽ More
Under negative feedback, the quality factor Q of a radio-frequency magnetometer can be decreased by more than two orders of magnitude, so that any initial perturbation of the polarized spin system can be rapidly damped, preparing the magnetometer for detection of the desired signal. We find that noise is also suppressed under such spin-dam**, with a characteristic spectral response corresponding to the type of noise; therefore magnetic, photon-shot, and spin-projection noise can be measured distinctly. While the suppression of resonant photon-shot noise implies the closed-loop production of polarization-squeezed light, the suppression of resonant spin-projection noise does not imply spin-squeezing, rather simply the broadening of the noise spectrum with Q. Furthermore, the application of spin-dam** during phase-sensitive detection suppresses both signal and noise in such a way as to increase the sensitivity bandwidth. We demonstrate a three-fold increase in the magnetometer's bandwidth while maintaining 0.3 fT/\surdHz sensitivity.
△ Less
Submitted 12 July, 2012;
originally announced July 2012.
-
Shape reconstruction in X-ray tomography from a small number of projections using deformable models
Authors:
A. Mohammad-Djafari,
Ken Sauer
Abstract:
X-ray tomographic image reconstruction consists of determining an object function from its projections. In many applications such as non-destructive testing, we look for a fault region (air) in a homogeneous, known background (metal). The image reconstruction problem then becomes the determination of the shape of the default region. Two approaches can be used: modeling the image as a binary Mark…
▽ More
X-ray tomographic image reconstruction consists of determining an object function from its projections. In many applications such as non-destructive testing, we look for a fault region (air) in a homogeneous, known background (metal). The image reconstruction problem then becomes the determination of the shape of the default region. Two approaches can be used: modeling the image as a binary Markov random field and estimating the pixels of the image, or modeling the shape of the fault and estimating it directly from the projections. In this work we model the fault shape by a deformable polygonal disc or a deformable polyhedral volume and propose a new method for directly estimating the coordinates of its vertices from a very limited number of its projections. The basic idea is not new, but in other competing methods, in general, the fault shape is modeled by a small number of parameters (polygonal shapes with very small number of vertices, snakes and deformable templates) and these parameters are estimated either by least squares or by maximum likelihood methods. We propose modeling the shape of the fault region by a polygon with a large number of vertices, allowing modeling of nearly any shape and estimation of its vertices' coordinates directly from the projections by defining the solution as the minimizer of an appropriate regularized criterion. This formulation can also be interpreted as a maximum a posteriori (MAP) estimate in a Bayesian estimation framework. To optimize this criterion we use either a simulated annealing or a special purpose deterministic algorithm based on iterated conditional modes (ICM). The simulated results are very encouraging, especially when the number and the angles of projections are very limited.
△ Less
Submitted 14 November, 2001;
originally announced November 2001.