Multi-scale analysis of lung computed tomography images
Authors:
I. Gori,
F. Bagagli,
M. E. Fantacci,
A. Preite Martinez,
A. Retico,
I. De Mitri,
S. Donadio,
C. Fulcheri,
G. Gargano,
R. Magro,
M. Santoro,
S. Stumbo
Abstract:
A computer-aided detection (CAD) system for the identification of lung internal nodules in low-dose multi-detector helical Computed Tomography (CT) images was developed in the framework of the MAGIC-5 project. The three modules of our lung CAD system, a segmentation algorithm for lung internal region identification, a multi-scale dot-enhancement filter for nodule candidate selection and a multi-…
▽ More
A computer-aided detection (CAD) system for the identification of lung internal nodules in low-dose multi-detector helical Computed Tomography (CT) images was developed in the framework of the MAGIC-5 project. The three modules of our lung CAD system, a segmentation algorithm for lung internal region identification, a multi-scale dot-enhancement filter for nodule candidate selection and a multi-scale neural technique for false positive finding reduction, are described. The results obtained on a dataset of low-dose and thin-slice CT scans are shown in terms of free response receiver operating characteristic (FROC) curves and discussed.
△ Less
Submitted 16 April, 2009;
originally announced April 2009.
Automated detection of lung nodules in low-dose computed tomography
Authors:
D. Cascio,
S. C. Cheran,
A. Chincarini,
G. De Nunzio,
P. Delogu,
M. E. Fantacci,
G. Gargano,
I. Gori,
G. L. Masala,
A. Preite Martinez,
A. Retico,
M. Santoro,
C. Spinelli,
T. Tarantino
Abstract:
A computer-aided detection (CAD) system for the identification of pulmonary nodules in low-dose multi-detector computed-tomography (CT) images has been developed in the framework of the MAGIC-5 Italian project. One of the main goals of this project is to build a distributed database of lung CT scans in order to enable automated image analysis through a data and cpu GRID infrastructure. The basic…
▽ More
A computer-aided detection (CAD) system for the identification of pulmonary nodules in low-dose multi-detector computed-tomography (CT) images has been developed in the framework of the MAGIC-5 Italian project. One of the main goals of this project is to build a distributed database of lung CT scans in order to enable automated image analysis through a data and cpu GRID infrastructure. The basic modules of our lung-CAD system, consisting in a 3D dot-enhancement filter for nodule detection and a neural classifier for false-positive finding reduction, are described. The system was designed and tested for both internal and sub-pleural nodules. The database used in this study consists of 17 low-dose CT scans reconstructed with thin slice thickness (~300 slices/scan). The preliminary results are shown in terms of the FROC analysis reporting a good sensitivity (85% range) for both internal and sub-pleural nodules at an acceptable level of false positive findings (1-9 FP/scan); the sensitivity value remains very high (75% range) even at 1-6 FP/scan
△ Less
Submitted 18 July, 2007;
originally announced July 2007.