Active Magnetoplasmonics with Transparent Conductive Oxide Nanocrystals
Authors:
Alessio Gabbani,
Claudio Sangregorio,
Bharat Tandon,
Angshuman Nag,
Massimo Gurioli,
Francesco Pineider
Abstract:
Magnetoplasmonics is highly promising to devise active optical elements: modulating the plasmon resonance condition with magnetic field can boost the performance of refractometric sensors and nanophotonic optical devices. Nevertheless, real life applications are hampered by the magnetoplasmonic trilemma: 1) a good plasmonic metal has sharp optical resonances but low magneto-optical response; 2) a…
▽ More
Magnetoplasmonics is highly promising to devise active optical elements: modulating the plasmon resonance condition with magnetic field can boost the performance of refractometric sensors and nanophotonic optical devices. Nevertheless, real life applications are hampered by the magnetoplasmonic trilemma: 1) a good plasmonic metal has sharp optical resonances but low magneto-optical response; 2) a magnetic metal has strong magneto-optical response but a very broad plasmonic resonance; 3) mixing the two components degrades the quality of both features. To overcome the trilemma, we use a different class of materials, transparent conductive oxide nanocrystals (NCs) with plasmonic response in the near infrared. Although non-magnetic, they combine a large cyclotron frequency (due to small electron effective mass) with sharp plasmonic resonances. We benchmark the concept with F- and In- doped CdO (FICO) and Sn-doped In2O3 (ITO) NCs to boost the magneto-optical Faraday rotation and ellipticity, reaching the highest magneto-optical response for a non-magnetic plasmonic material, and exceeding the performance of state-of-the-art ferromagnetic nanostructures. The magnetoplasmonic response of these NCs was rationalized with analytical model based on the excitation of circular magnetoplasmonic modes. Finally, proof of concept experiments demonstrated the superior performance of FICO NCs with respect to current state of the art in magnetoplasmonic refractometric sensing, approaching the sensitivity of leading localized plasmon refractometric methods with the advantage of not requiring complex curve fitting.
△ Less
Submitted 15 April, 2021;
originally announced April 2021.
Experimental determination of the frequency and field dependence of Specific Loss Power in Magnetic Fluid Hyperthermia
Authors:
M. Cobianchi,
A. Guerrini,
M. Avolio,
C. Innocenti,
M. Corti,
P. Arosio,
F. Orsini,
C. Sangregorio,
A. Lascialfari
Abstract:
Magnetic nanoparticles are promising systems for biomedical applications and in particular for Magnetic Fluid Hyperthermia, a promising therapy that utilizes the heat released by such systems to damage tumor cells. We present an experimental study of the physical properties that influences the capability of heat release, i.e. the Specific Loss Power, SLP, of three biocompatible ferrofluid samples…
▽ More
Magnetic nanoparticles are promising systems for biomedical applications and in particular for Magnetic Fluid Hyperthermia, a promising therapy that utilizes the heat released by such systems to damage tumor cells. We present an experimental study of the physical properties that influences the capability of heat release, i.e. the Specific Loss Power, SLP, of three biocompatible ferrofluid samples having a magnetic core of maghemite with different core diameter d= 10.2, 14.6 and 19.7 nm. The SLP was measured as a function of frequency f and intensity of the applied alternating magnetic field H, and it turned out to depend on the core diameter, as expected. The results allowed us to highlight experimentally that the physical mechanism responsible for the heating is size-dependent and to establish, at applied constant frequency, the phenomenological functional relationship SLP=cH^x, with 2<x<3 for all samples. The x-value depends on sample size and field frequency/ intensity, here chosen in the typical range of operating magnetic hyperthermia devices. For the smallest sample, the effective relaxation time Teff=19.5 ns obtained from SLP data is in agreement with the value estimated from magnetization data, thus confirming the validity of the Linear Response Theory model for this system at properly chosen field intensity and frequency.
△ Less
Submitted 10 April, 2017;
originally announced April 2017.