-
Optimal Demodulation Domain for Microwave SQUID Multiplexers in Presence of Readout System Noise
Authors:
M. E. García Redondo,
N. A. Müller,
J. M. Salum,
L. P. Ferreyro,
J. D. Bonilla-Neira,
J. M. Geria,
J. J. Bonaparte,
T. Muscheid,
R. Gartmann,
A. Almela,
M. R. Hampel,
A. E. Fuster,
L. E. Ardila-Perez,
M. Wegner,
M. Platino,
O. Sander,
S. Kempf,
M. Weber
Abstract:
The Microwave SQUID Multiplexer (μMUX) is the device of choice for the readout of a large number of Low-Temperature Detectors in a wide variety of experiments within the fields of astronomy and particle physics. While it offers large multiplexing factors, the system noise performance is highly dependent on the cold and warm-readout electronic systems used to read it out, as well as the demodulatio…
▽ More
The Microwave SQUID Multiplexer (μMUX) is the device of choice for the readout of a large number of Low-Temperature Detectors in a wide variety of experiments within the fields of astronomy and particle physics. While it offers large multiplexing factors, the system noise performance is highly dependent on the cold and warm-readout electronic systems used to read it out, as well as the demodulation domain and parameters chosen. In order to understand the impact of the readout systems in the overall noise performance, first we extended the available μMUX simulation frameworks including additive and multiplicative noise sources in the probing tones (i.e. phase and amplitude noise), along with the capability of demodulating the scientific data, either in resonator's phase or amplitude. Then, considering the additive noise as a dominant noise source, the optimum readout parameters to achieve minimum system noise were found for both open-loop and flux-ramp demodulation schemes in the aforementioned domains. Later, we evaluated the system noise sensitivity to multiplicative noise sources under the optimum readout parameters. Finally, as a case study, we evaluated the optimal demodulation domain and expected system noise level for a typical Software-Defined Radio (SDR) readout system. This work leads to an improved system performance prediction and noise engineering based on the available readout electronics and selected demodulation domain.
△ Less
Submitted 10 June, 2024;
originally announced June 2024.
-
RFSoC Gen3-Based Software-Defined Radio Characterization for the Readout System of Low-Temperature Bolometers
Authors:
M. E. García Redondo,
T. Muscheid,
R. Gartmann,
J. M. Salum,
L. P. Ferreyro,
N. A. Müller,
J. D. Bonilla-Neira,
J. M. Geria,
J. J. Bonaparte,
A. Almela,
L. E. Ardila-Perez,
M. R. Hampel,
A. E. Fuster,
M. Platino,
O. Sander,
M. Weber,
A. Etchegoyen
Abstract:
This work reports the performance evaluation of an SDR readout system based on the latest generation (Gen3) of the AMD's Radio Frequency System-on-Chip (RFSoC) processing platform, which integrates a full-stack processing system and a powerful FPGA with up to 32 high-speed and high-resolution 14-bit Digital-to-Analog Converters (DACs) and Analog-to-Digital Converters (ADCs). The proposed readout s…
▽ More
This work reports the performance evaluation of an SDR readout system based on the latest generation (Gen3) of the AMD's Radio Frequency System-on-Chip (RFSoC) processing platform, which integrates a full-stack processing system and a powerful FPGA with up to 32 high-speed and high-resolution 14-bit Digital-to-Analog Converters (DACs) and Analog-to-Digital Converters (ADCs). The proposed readout system uses a previously developed multi-band, double-conversion IQ RF-mixing board targeting a multiplexing factor of approximately 1,000 bolometers in a bandwidth between 4 and 8 GHz, in line with state-of-the-art microwave SQUID multiplexers ($μ$MUX). The characterization of the system was performed in two stages, under the conditions typically imposed by the multiplexer and the cold readout circuit. First, in transmission, showing that noise and spurious levels of the generated tones are close to the values imposed by the cold readout. Second, in RF loopback, presenting noise values better than -100 dBc/Hz totally in agreement with the state-of-the-art readout systems. It was demonstrated that the RFSoC Gen3 device is a suitable enabling technology for the next generation of superconducting detector readout systems, reducing system complexity, increasing system integration, and achieving these goals without performance degradation.
△ Less
Submitted 8 May, 2024; v1 submitted 6 November, 2023;
originally announced November 2023.
-
Suitability of Magnetic Microbolometers based on Paramagnetic Temperature Sensors for CMB Polarization Measurements
Authors:
Juan Manuel Geria,
Matias Rolf Hampel,
Sebastian Kempf,
Juan Jose Bonaparte,
Luciano Pablo Ferreyro,
Manuel Elías García Redondo,
Daniel Alejandro Almela,
Juan Manuel Salum,
Nahuel Müller,
Jesus David Bonilla-Neira,
Alan Ezequiel Fuster,
Manuel Platino,
Alberto Etchegoyen
Abstract:
High resolution maps of polarization anisotropies of the Cosmic Microwave Background (CMB) are in high demand, since the discovery of primordial B-Modes in the polarization patterns would confirm the inflationary phase of the Universe that would have taken place before the last scattering of the CMB at the recombination epoch. Transition Edge Sensors (TES) and Microwave Kinetic Inductance Detector…
▽ More
High resolution maps of polarization anisotropies of the Cosmic Microwave Background (CMB) are in high demand, since the discovery of primordial B-Modes in the polarization patterns would confirm the inflationary phase of the Universe that would have taken place before the last scattering of the CMB at the recombination epoch. Transition Edge Sensors (TES) and Microwave Kinetic Inductance Detectors (MKID) are the predominant detector technologies of cryogenic detector array based CMB instruments that search for primordial B-Modes. In this paper we propose another type of cryogenic detector to be used for CMB survey: A magnetic microbolometer (MMB) that is based on a paramagnetic temperature sensor. It is an adaption of state-of-the-art metallic magnetic calorimeters (MMCs) that are meanwhile a key technology for high resolution $α$, $β$, $γ$ and X-ray spectroscopy as well as the study of neutrino mass. The effort to adapt MMCs for CMB surveys is triggered by their lack of Johnson noise associated with the detector readout, the possibility of straightforward calibration and higher dynamic range given it possesses a broad and smooth responsivity dependence with temperature and the absence of Joule dissipation which simplifies the thermal design. A brief proof of concept case study is analyzed, taking into account typical constraints in CMB measurements and reliable microfabrication processes. The results show that MMBs provide a promising technology for CMB polarization survey as their sensitivity can be tuned for background limited detection of the sky while simultaneously maintaining a low time response to avoid distortion of the point-source response of the telescope. As the sensor technology and its fabrication techniques are compatible with TES based bolometric detector arrays, a change of detector technology would even come with very low cost.
△ Less
Submitted 10 June, 2024; v1 submitted 13 September, 2022;
originally announced September 2022.
-
QUBIC VII: The feedhorn-switch system of the technological demonstrator
Authors:
F. Cavaliere,
A. Mennella,
M. Zannoni,
P. Battaglia,
E. S. Battistelli,
D. Burke,
G. D'Alessandro,
P. de Bernardis,
M. De Petris,
C. Franceschet,
L. Grandsire,
J. -Ch. Hamilton,
B. Maffei,
E. Manzan,
S. Marnieros,
S. Masi,
C. O'Sullivan,
A. Passerini,
F. Pezzotta,
M. Piat,
A. Tartari,
S. A. Torchinsky,
D. Viganò,
F. Voisin,
P. Ade
, et al. (106 additional authors not shown)
Abstract:
We present the design, manufacturing and performance of the horn-switch system developed for the technological demonstrator of QUBIC (the $Q$\&$U$ Bolometric Interferometer for Cosmology). This system is constituted of 64 back-to-back dual-band (150\,GHz and 220\,GHz) corrugated feed-horns interspersed with mechanical switches used to select desired baselines during the instrument self-calibration…
▽ More
We present the design, manufacturing and performance of the horn-switch system developed for the technological demonstrator of QUBIC (the $Q$\&$U$ Bolometric Interferometer for Cosmology). This system is constituted of 64 back-to-back dual-band (150\,GHz and 220\,GHz) corrugated feed-horns interspersed with mechanical switches used to select desired baselines during the instrument self-calibration. We manufactured the horns in aluminum platelets milled by photo-chemical etching and mechanically tightened with screws. The switches are based on steel blades that open and close the wave-guide between the back-to-back horns and are operated by miniaturized electromagnets. We also show the current development status of the feedhorn-switch system for the QUBIC full instrument, based on an array of 400 horn-switch assemblies.
△ Less
Submitted 1 April, 2022; v1 submitted 28 August, 2020;
originally announced August 2020.
-
QUBIC V: Cryogenic system design and performance
Authors:
S. Masi,
E. S. Battistelli,
P. de Bernardis,
C. Chapron,
F. Columbro,
G. D'Alessandro,
M. De Petris,
L. Grandsire,
J. -Ch. Hamilton,
S. Marnieros,
L. Mele,
A. May,
A. Mennella,
C. O'Sullivan,
A. Paiella,
F. Piacentini,
M. Piat,
L. Piccirillo,
G. Presta,
A. Schillaci,
A. Tartari,
J. -P. Thermeau,
S. A. Torchinsky,
F. Voisin,
M. Zannoni
, et al. (104 additional authors not shown)
Abstract:
Current experiments aimed at measuring the polarization of the Cosmic Microwave Background (CMB) use cryogenic detector arrays and cold optical systems to boost the map** speed of the sky survey. For these reasons, large volume cryogenic systems, with large optical windows, working continuously for years, are needed. Here we report on the cryogenic system of the QUBIC (Q and U Bolometric Interfe…
▽ More
Current experiments aimed at measuring the polarization of the Cosmic Microwave Background (CMB) use cryogenic detector arrays and cold optical systems to boost the map** speed of the sky survey. For these reasons, large volume cryogenic systems, with large optical windows, working continuously for years, are needed. Here we report on the cryogenic system of the QUBIC (Q and U Bolometric Interferometer for Cosmology) experiment: we describe its design, fabrication, experimental optimization and validation in the Technological Demonstrator configuration. The QUBIC cryogenic system is based on a large volume cryostat, using two pulse-tube refrigerators to cool at ~3K a large (~1 m^3) volume, heavy (~165kg) instrument, including the cryogenic polarization modulator, the corrugated feedhorns array, and the lower temperature stages; a 4He evaporator cooling at ~1K the interferometer beam combiner; a 3He evaporator cooling at ~0.3K the focal-plane detector arrays. The cryogenic system has been tested and validated for more than 6 months of continuous operation. The detector arrays have reached a stable operating temperature of 0.33K, while the polarization modulator has been operated from a ~10K base temperature. The system has been tilted to cover the boresight elevation range 20 deg -90 deg without significant temperature variations. The instrument is now ready for deployment to the high Argentinean Andes.
△ Less
Submitted 25 August, 2021; v1 submitted 24 August, 2020;
originally announced August 2020.