3D Ultrafast Shear Wave Absolute Vibro-Elastography using a Matrix Array Transducer
Authors:
Hoda S. Hashemi,
Shahed K. Mohammed,
Qi Zeng,
Reza Zahiri Azar,
Robert N. Rohling,
Septimiu E. Salcudean
Abstract:
3D ultrasound imaging provides more spatial information compared to conventional 2D frames by considering the volumes of data. One of the main bottlenecks of 3D imaging is the long data acquisition time which reduces practicality and can introduce artifacts from unwanted patient or sonographer motion. This paper introduces the first shear wave absolute vibro-elastography (S-WAVE) method with real-…
▽ More
3D ultrasound imaging provides more spatial information compared to conventional 2D frames by considering the volumes of data. One of the main bottlenecks of 3D imaging is the long data acquisition time which reduces practicality and can introduce artifacts from unwanted patient or sonographer motion. This paper introduces the first shear wave absolute vibro-elastography (S-WAVE) method with real-time volumetric acquisition using a matrix array transducer. In SWAVE, an external vibration source generates mechanical vibrations inside the tissue. The tissue motion is then estimated and used in solving a wave equation inverse problem to provide the tissue elasticity. A matrix array transducer is used with a Verasonics ultrasound machine and frame rate of 2000 volumes/s to acquire 100 radio frequency (RF) volumes in 0.05 s. Using plane wave (PW) and compounded diverging wave (CDW) imaging methods, we estimate axial, lateral and elevational displacements over 3D volumes. The curl of the displacements is used with local frequency estimation to estimate elasticity in the acquired volumes. Ultrafast acquisition extends substantially the possible S-WAVE excitation frequency range, now up to 800 Hz, enabling new tissue modeling and characterization. The method was validated on three homogeneous liver fibrosis phantoms and on four different inclusions within a heterogeneous phantom. The homogeneous phantom results show less than 8% (PW) and 5% (CDW) difference between the manufacturer values and the corresponding estimated values over a frequency range of 80 Hz to 800 Hz. The estimated elasticity values for the heterogeneous phantom at 400 Hz excitation frequency show average errors of 9% (PW) and 6% (CDW) compared to the provided average values by MRE. Furthermore, both imaging methods were able to detect the inclusions within the elasticity volumes.
△ Less
Submitted 22 May, 2023;
originally announced September 2023.
-
Quasi-Real Time Multi-Frequency 3D Shear Wave Absolute Vibro-Elastography (S-WAVE) System for Prostate
Authors:
Tajwar Abrar Aleef,
Julio Lobo,
Ali Baghani,
Hani Eskandari,
Hamid Moradi,
Robert Rohling,
S. Larry Goldenberg,
William James Morris,
S. Sara Mahdavi,
Septimiu E. Salcudean
Abstract:
This article describes a novel quasi-real time system for quantitative and volumetric measurement of tissue elasticity in the prostate. Tissue elasticity is computed by using a local frequency estimator to measure the three dimensional local wavelengths of a steady-state shear wave within the prostate gland. The shear wave is created using a mechanical voice coil shaker which transmits multi-frequ…
▽ More
This article describes a novel quasi-real time system for quantitative and volumetric measurement of tissue elasticity in the prostate. Tissue elasticity is computed by using a local frequency estimator to measure the three dimensional local wavelengths of a steady-state shear wave within the prostate gland. The shear wave is created using a mechanical voice coil shaker which transmits multi-frequency vibrations transperineally. Radio frequency data is streamed directly from a BK Medical 8848 trans-rectal ultrasound transducer to an external computer where tissue displacement due to the excitation is measured using a speckle tracking algorithm. Bandpass sampling is used that eliminates the need for an ultra fast frame rate to track the tissue motion and allows for accurate reconstruction at a sampling frequency that is below the Nyquist rate. A roll motor with computer control is used to rotate the sagittal array of the transducer and obtain the 3D data. Two CIRS phantoms were used to validate both the accuracy of the elasticity measurement as well as the functional feasibility of using the system for in vivo prostate imaging. The system has been used in two separate clinical studies as a method for cancer identification. The results, presented here, show numerical and visual correlations between our stiffness measurements and cancer likelihood as determined from pathology results. Initial published results using this system include an area under the receiver operating characteristic curve of 0.82+/-0.01 with regards to prostate cancer identification in the peripheral zone.
△ Less
Submitted 9 May, 2022;
originally announced May 2022.
-
Ultrafast Ultrasound Imaging for 3D Shear Wave Absolute Vibro-Elastography
Authors:
Hoda S. Hashemi,
Reza Zahiri Azar,
Septimiu E. Salcudean,
Robert N. Rohling
Abstract:
Shear wave absolute vibro-elastography (S-WAVE) is an imaging technique that generates steady-state shear waves inside the tissue using multi-frequency excitation from an external vibration source. In this work, plane wave imaging is introduced to reduce total acquisition time while retaining the benefit of 3D formulation. Plane wave imaging with a frame rate of 3000 frames/s is followed by 3D abs…
▽ More
Shear wave absolute vibro-elastography (S-WAVE) is an imaging technique that generates steady-state shear waves inside the tissue using multi-frequency excitation from an external vibration source. In this work, plane wave imaging is introduced to reduce total acquisition time while retaining the benefit of 3D formulation. Plane wave imaging with a frame rate of 3000 frames/s is followed by 3D absolute elasticity estimation. We design two imaging sequences of ultrafast S-WAVE for two sets of excitation frequencies using a Verasonics system and a motorized swept ultrasound transducer to synchronize ultrasound acquisition with the external mechanical excitation. The overall data collection time is improved by 83-88% compared to the original 3D S-WAVE because of the per-channel acquisition offered by the Verasonics system. Tests are performed on liver fibrosis tissue-mimicking phantoms and on ex vivo bovine liver. The curl operator was previously used in magnetic resonance elastography (MRE) to cancel out the effect of the compressional waves. In this work, we apply the curl operator to the full 3D displacement field followed by 3D elasticity reconstruction. The results of phantom experiment show more accurate elasticity estimation as well as 18% less standard deviation (STD) compared to reconstruction using the curl of a 2D displacement field and 45% less STD than without the curl. We also compare our experimental results with a previous method based on acoustic radiation force impulse (ARFI) and achieve closer results to phantom manufacturer provided values with ultrafast S-WAVE. Furthermore, the dependency of the bovine liver elasticity on the frequency of excitation was also shown with our system.
△ Less
Submitted 25 July, 2023; v1 submitted 25 March, 2022;
originally announced March 2022.
-
A Multiparametric Volumetric Quantitative Ultrasound Imaging Technique for Soft Tissue Characterization
Authors:
Farah Deeba,
Caitlin Schneider,
Shahed Mohammed,
Mohammad Honarvar,
Julio Lobo,
Edward Tam,
Septimiu Salcudean,
Robert Rohling
Abstract:
Quantitative ultrasound (QUS) offers a non-invasive and objective way to quantify tissue health. We recently presented a spatially adaptive regularization method for reconstruction of a single QUS parameter, limited to a two dimensional region. That proof-of-concept study showed that regularization using homogeneity prior improves the fundamental precision-resolution trade-off in QUS estimation. B…
▽ More
Quantitative ultrasound (QUS) offers a non-invasive and objective way to quantify tissue health. We recently presented a spatially adaptive regularization method for reconstruction of a single QUS parameter, limited to a two dimensional region. That proof-of-concept study showed that regularization using homogeneity prior improves the fundamental precision-resolution trade-off in QUS estimation. Based on the weighted regularization scheme, we now present a multiparametric 3D weighted QUS (3D QUS)imaging system, involving the reconstruction of three QUS parameters: attenuation coefficient estimate (ACE), integrated backscatter coefficient (IBC) and effective scatterer diameter (ESD). With the phantom studies, we demonstrate that our proposed method accurately reconstructs QUS parameters, resulting in high reconstruction contrast and therefore improved diagnostic utility. Additionally, the proposed method offers the ability to analyze the spatial distribution of QUS parameters in 3D, which allows for superior tissue characterization. We apply a three-dimensional total variation regularization method for the volumetric QUS reconstruction. The 3D regularization involving N planes results in a high QUS estimation precision, with an improvement of standard deviation over the theoretical rate achievable by compounding N independent realizations. In the in vivo liver study, we demonstrate the advantage of adopting a multiparametric approach over the single parametric counterpart, where a simple quadratic discriminant classifier using feature combination of three QUS parameters was able to attain a perfect classification performance to distinguish between normal and fatty liver cases.
△ Less
Submitted 1 April, 2021;
originally announced April 2021.
-
Rapid treatment planning for low-dose-rate prostate brachytherapy with TP-GAN
Authors:
Tajwar Abrar Aleef,
Ingrid T. Spadinger,
Michael D. Peacock,
Septimiu E. Salcudean,
S. Sara Mahdavi
Abstract:
Treatment planning in low-dose-rate prostate brachytherapy (LDR-PB) aims to produce arrangement of implantable radioactive seeds that deliver a minimum prescribed dose to the prostate whilst minimizing toxicity to healthy tissues. There can be multiple seed arrangements that satisfy this dosimetric criterion, not all deemed 'acceptable' for implant from a physician's perspective. This leads to pla…
▽ More
Treatment planning in low-dose-rate prostate brachytherapy (LDR-PB) aims to produce arrangement of implantable radioactive seeds that deliver a minimum prescribed dose to the prostate whilst minimizing toxicity to healthy tissues. There can be multiple seed arrangements that satisfy this dosimetric criterion, not all deemed 'acceptable' for implant from a physician's perspective. This leads to plans that are subjective to the physician's/centre's preference, planning style, and expertise. We propose a method that aims to reduce this variability by training a model to learn from a large pool of successful retrospective LDR-PB data (961 patients) and create consistent plans that mimic the high-quality manual plans. Our model is based on conditional generative adversarial networks that use a novel loss function for penalizing the model on spatial constraints of the seeds. An optional optimizer based on a simulated annealing (SA) algorithm can be used to further fine-tune the plans if necessary (determined by the treating physician). Performance analysis was conducted on 150 test cases demonstrating comparable results to that of the manual prehistorical plans. On average, the clinical target volume covering 100% of the prescribed dose was 98.9% for our method compared to 99.4% for manual plans. Moreover, using our model, the planning time was significantly reduced to an average of 2.5 mins/plan with SA, and less than 3 seconds without SA. Compared to this, manual planning at our centre takes around 20 mins/plan.
△ Less
Submitted 17 March, 2021;
originally announced March 2021.